• 제목/요약/키워드: dental resin composite

검색결과 521건 처리시간 0.024초

표면처리에 따른 상아질과 콤포짓드 레진간의 전단결합강도에 관한 연구 (A STUDY ON SHEAR BOND STRENGTH OF COMPOSITE RESIN TO DENTIN FOLLOWING SURFACE TREATMENTS)

  • 노은희;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.200-208
    • /
    • 1991
  • The purpose of this study was to observe shear bond strength of composite resin to dentin following surface treatment. Freshly extracted forty-eight sound human molars were used in this study. They were stored at $4^{\circ}C$ physiologic saline solution before experiment. The teeth was then mounted with self curing acrylic resin in brass mold. The buccal surfaces of the teeth were grinding approximately 1.5mm by means of water-irrigated grinding wheel to expose the flattened fresh dentin surfaces. The specimens were divided into 6 groups according to preparation and treatment procedures on dentin surfaces; Group 1: Untreated after preparation with No.301 diamond point Group 2: Treated with primer for 60 seconds after preparation with No.301 diamond point Group 3: Untreated after preparation with No.700 fissure carbide bur Group 4: Treated with primer for 60 seconds after preparation with No.700 fissure carbide bur Group 5: Untreated after grinding with 600 grit silicon carbide paper Group 6: Treated with primer for 60 seconds after grinding with 600 grit silicon carbide paper Light cure dental adhesive was applicated to each specimen. Silux plus(3M) was inserted then into polyethylene tube of 3mm diameter and 3mm height, and polymerized to dentin surface. All of the specimens were stored in distilled water at $35.6^{\circ}C$ for 24 hours prior to testing. The shear bond strength was measured using an Instron Universal Testing Machine. The results obtained from this study were as follows: 1. The shear bond strength to dentin was the highest in group II. 2. The shear bond strength to dentin was the lowest in group III. 3. There was no significant difference in shear bond strength to dentin according to preparation instrument. 4. The primer treatment group showed significantly greater shear bond strength than untreated group.

  • PDF

산 표면처리 후 상아질 표면의 습윤이 하이브리드층 형성에 관한 전자현미경적 연구 (ELECTRON MICROSCOPIC STUDY OF RESIN-DENTIN HYBRID ZONE PRODUCED BY THE MOISTENING OF ACID CONDITIONED DENTIN SURFACE)

  • 이광원;이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.463-486
    • /
    • 1995
  • The effect of moistening and air-drying of acid-conditioned dentin before priming on the formation of resin-dentin hybrid zone was investigated, Freshly extracted human molars were used and divided at random into 5 groups, Groups 1 - 3 consisted of specimens conditioned with 10 % phosphoric acid for 20 seconds; Group 1 served as a control in which the conditioned dentin was simply blot-dried with a damp facial tissue; Group 2 was air dried for 30 seconds ; Group 3 was air dried for 30 seconds and immediately remoistened for 10 seconds with air-water syringe. and then the specimen was blot-dried with a damp facial tissue. Groups 4-5 were not acid conditioned ; In group 4, the smear layer on the dentin was blot dried before primer placement; Group 5 was air dried only for 30 seconds, The acetone-based primer and bonding agent of All Bond 2 (Bisco. Inc., USA) and composite resin (Z-100, 3M Dental products, USA) were applied for acid conditioned dentin and non-conditioned dentin. The morphologic ultrastructure of resin-dentin hybrid zone was examined by the use of SEM and TEM. and the existence of inorganic material and analysis of Ca/P weight-percent ratio in the resin-dentin hybrid zone were revealed by the EDAX, The results were as follows : 1. In the moistened specimens from acid-conditioned groups, the resin penetrated about 3-$4{\mu}m$ into dentin and the denatured collagen smear layer was not present at the surface. The resin tag was formed to a thickeness of 3-$4{\mu}m$ at the upper part of dentinal tubule and compactively connected to each other by means of many lateral branching. 2. In the air-dried specimens from acid-conditioned groups, the resin penetrated about 2.0-$2.5\;{\mu}m$ into dentin and an upper thin black layer to a thickness of 30-35nm was identified between adhesive resin and demineralized collagen layer. The resin tag to have a diameter of $2.5{\mu}m$ was formed at the upper part of dentinal tubule. However the funnel shape of the tag was not notable compared to the moistened specimens. 3. In the remoistened specimens from acid conditioned groups, the resin penetrated about 2.0-$2.5{\mu}m$ into dentin and an upper black layer was not present. The resin tag at the upper part of dentinal tubule was formed less than $2{\mu}m$ and was weakly connected to each other by means of few lateral branching. 4. In the non-conditioned groups, the smear layer was formed to a thickness of $0.5{\mu}m$ at dentin surface. However, the resin-dentin hybrid zone was not identified by TEM. The evidence of resin penetration into intertubular and intratubular dentin did not show. 5. All the acid-conditioned groups showed that the detected calcium and phosphorus weight percent ratios at the $2{\mu}m$ upper portion from the resin-dentin interface into the resin were much higher than that at the $2{\mu}m$ lower portion from the resin-dentin interface to dentin. (P<0.01).

  • PDF

표면 상태와 용액에 따른 치과용 수복재료의 색안정도 평가 (Evaluation of Surface Condition and Food Solution on the Color Stability of Dental Restoration Materials)

  • 우희선;김효진;전수경
    • 한국콘텐츠학회논문지
    • /
    • 제19권4호
    • /
    • pp.359-367
    • /
    • 2019
  • 본 연구는 치과용 수복재료의 연마유무에 따라 여러 가지 착색용액에서 색의 안정성을 보기 위해 유동성 레진, 하이브리드 레진, 컴포머, 레진강화형 글라스 아이오노머를 이용하여 평가하였다. 치과용 수복재료인 컴포짓트 레진을 테플론 몰드로 직경10 mm, 두께 2 mm 시편을 제작하였으며, 두 군으로 나누어 한 군은 연마지를 이용하여 20초간 연마하였고, 다른 한 군은 연마하지 않고 평가하였다. 실험 결과 기간과 재료별 착색시료 간에는 통계학적으로 유의한 차이가 있었다(p<0.05). 간장과 고추장에서는 레진 강화형 글라스 아이오노머 Fuji II LC와 하이브리드 레진 중 Prodigy에서 2일째 수용도 역치 이상의 색 변화가 나타났으며, 연마지를 사용한 군에서는 간장용액에서는 레진 강화형 글라스 아이오노머 Fuji II LC가 2일째에 색변화가 있었으며, 고추장용액에서는 유동성레진과 하이브리드 레진 중 Prodigy에서 7일째 색변화가 나타났다. 와인용액에서는 컴포머와 하이브리드 레진 중 Prodigy에서 2일째 색 변화가 나타났으며, 연마지를 사용한 군에서는 컴포머에서 2일째 수용도 역치 이상의 색 변화를 볼 수 있었다. 향후 레진 표면의 활택도에 따라 착색에 영향을 줄 수 있으므로 향후 다양한 연마방법을 통한 연구가 진행되어야 할 것으로 사료된다.

뇌성마비 환자에서 함입된 상악 중절치의 외과적 재위치: 증례보고 (SURGICAL REPOSITIONING OF AN INTRUDED PERMANENT MAXILLARY INCISOR IN A CEREBRAL PALSY PATIENT: A CASE REPORT)

  • 이고은;이명연;이제호
    • 대한장애인치과학회지
    • /
    • 제13권1호
    • /
    • pp.43-46
    • /
    • 2017
  • 본 증례는 함입 주소로 내원한 9세 4개월 뇌성마비 남환을 미다졸람 근주를 이용한 의식하 진정법으로 해당치아의 수술 적 재위치 및 근관치료를 시행하였다. 5년이 지난 현재 유착 소견 및 부분적인 치근흡수가 보이나 양호한 상태로 유지되고 있다. 뇌성마비 환자의 경우 치아 및 주위조직에 취약하며, 치료 시 적절한 행동조절 및 치료 방법을 선택하는 임상의의 노력이 필요하다.

Effect of chlorhexidine application on the bond strength of resin core to axial dentin in endodontic cavity

  • Kim, Yun-Hee;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.207-214
    • /
    • 2012
  • Objectives: This study evaluated the influence of chlorhexidine (CHX) on the microtensile bonds strength (${\mu}TBS$) of resin core with two adhesive systems to dentin in endodontic cavities. Materials and Methods: Flat dentinal surfaces in 40 molar endodontic cavities were treated with self-etch adhesive system, Contax (DMG) and total-etch adhesive system, Adper Single Bond 2 (3M ESPE) after the following surface treatments: (1) Priming only (Contax), (2) CHX for 15 sec + rinsing + priming (Contax), (3) Etching with priming (Adper Single Bond 2), (4) Etching + CHX for 15 sec + rinsing + priming (Adper Single Bond 2). Resin composite build-ups were made with LuxaCore (DMG) using a bulk method and polymerized for 40 sec. For each condition, half of specimens were submitted to ${\mu}TBS$ after 24 hr storage and half of them were submitted to thermocycling of 10,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ before testing. The data were analyzed using ANOVA and independent t-test at a significance level of 95%. Results: CHX pre-treatment did not affect the bond strength of specimens tested at the immediate testing period, regardless of dentin surface treatments. However, after 10,000 thermocycling, all groups showed reduced bond strength. The amount of reduction was greater in groups without CHX treatments than groups with CHX treatment. These characteristics were the same in both self-etch adhesive system and total-etch adhesive system. Conclusions: 2% CHX application for 15 sec proved to alleviate the decrease of bond strength of dentin bonding systems. No significant difference was shown in ${\mu}TBS$ between total-etching system and self-etching system.

광중합 복합레진의 화학적 분해 평가 (AN EVALUATION OF CHEMICAL DEGRADATION OF LIGHT-CURED RESTORATIVE COMPOSITES)

  • 양규호;김훈주;최남기
    • 대한소아치과학회지
    • /
    • 제30권3호
    • /
    • pp.530-539
    • /
    • 2003
  • 본 연구에서는 4종의 복합레진(Palpique Estelite, Filtek P 60, Spectrum, Charisma)을 선택하였다. 각 제품당 5개의 시편을 제작하여 무게 측정을 한 후, NaOH 용액에 2주 동안 보관하였고 1.23% HCl로 중화하고 세척, 건조시켜 무게 측정을 하였다. 주사전자현미경과 공초점 레이저 주사현미경으로 복합레진의 분해층 표면과 분해깊이를 관찰하였고, 분해 저항성은 용액내로 용출된 Si, Al, Ba의 농도를 근거로 평가하여 다음과 같은 결과를 얻었다. 1. 각 제품의 무게손실량은 Palpique Estelite가 가장 많았고, Filtek P 60, Charisma, Spectrum 순이었다. 2. 각 제품의 표면하 분해층 깊이는 Filtek P 60이 가장 깊었고, Charisma, Palpique Estelite, Spectrum 순이었다. 3. Si 용출량은 Charisma가 가장 많았고, Spectrum, Palpique Estelite, Filtek P 60 순이었다. 4. 무게손실과 분해층 깊이 사이에는 높은 상관관계를 보였다(r=0.704, p<0.05). 5. 주사전자현미경 관찰시 NaOH용액에 보관한 후 레진 기질과 충전제 사이의 결합의 파괴 양상인 분해층 표면을 관찰할 수 있었고 공초점 레이저 현미경 관찰시 레진의 분해층 깊이를 관찰할 수 있었다.

  • PDF

Biological Effects of Light-Emitting Diodes Curing Unit on MDPC-23 Cells and Lipopolysaccharide Stimulated MDPC-23 Cells

  • Jeong, Moon-Jin;Jeong, Soon-Jeong
    • 치위생과학회지
    • /
    • 제19권1호
    • /
    • pp.39-47
    • /
    • 2019
  • Background: Light-emitting diodes curing unit (LCU), which emit blue light, is used for polymerization of composite resins in many dentistry. Although the use of LCU for light-cured composite resin polymerization is considered safe, it is still controversial whether it can directly or indirectly have harmful biological influences on oral tissues. The aim of this study was to elucidate the biological effects of LCU in wavelengths ranging from 440 to 490 nm, on the cell viability and secretion of inflammatory cytokines in MDPC-23 odontoblastic cells and inflammatory-induced MDPC-23 cells by lipopolysaccharide (LPS). Methods: The MTT assay and observation using microscope were performed on MDPC-23 cells to investigate the cell viability and cytotoxic effects on LCU irradiation. Results: MDPC-23 cells and LPS stimulated MDPC-23 cells were found to have no effects on cell viability and cell morphology in the LCU irradiation. Nitric oxide (NO) and prostaglandin $E_2$ which are the pro-inflammatory mediators, and interleukin-$1{\beta}$ and tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) which are the proinflammatory cytokines were significantly increased in MCPD-23 cells after LCU irradiation as time increased in comparison with the control. LCU irradiation has the potential to induce inflammation or biological damages in normal dental tissues, including MDPC-23 cells. Conclusion: Therefore, it is necessary to limit the use of LCU except for the appropriate dose and irradiation time. In addition, LCU irradiation of inflammatory-induced MDPC-23 cells by LPS was reduced the secretion of NO compared to the LPS alone treatment group and was significantly reduced the secretion of TNF-${\alpha}$ in all the time groups. Therefore, LCU application in LPS stimulated MDPC-23 odontoblastic cells has a photodynamic therapy like effect as well as inflammation relief.

다양한 치은 연하 수복물에 대한 치은 섬유아 세포 부착 연구 (Attachment of Human Gingival Fibroblast to Various Subgingival Restorations;A Comparative Study in Vitro)

  • 이은숙;송인택;임정수;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제29권3호
    • /
    • pp.621-636
    • /
    • 1999
  • When mucoperiosteal flaps are positioned and sutured to desirable position, the wound contains several interface between tissues which differ fundamentally in composition & biological reaction. Thus the C-T surface of the flap will, on one hand, oppose another vascularized surface, and on the other, the avascular dental material for example, when root resoptions, fractured root, endodontic perforation, deep root carious lesions were filled with amalgam, glass ionomer, resin etc. Recently, a number of case report described the successful treatment of a subgingival root lesion with restorative material & free gingival graft, open flap surgery, but more objective research was needed . Most of study on restorative materials were concerned for cytotoxicity not for actual healing event on that materials and its influencing factors such as biocompatibility, surface wettability, surface topography . The aim of this in vitro study was to evaluate the effect of amalgam, resin modified glass ionomer, composite resin per se, and their surface roughness on the growth of human gingival fibroblast. The cells were obtained and placed on culture flask and incubated for 3 days with the prepared test materials. Then count the attached cell number with hemocytometer,(n=12) and 2 samples were examined with SEM about attachment cell morphology . Another 4 samples were evaluated on their surface roughness with Talysurf and average surface roughness value(Ra) were obtained. Statistical difference in attached cell number, roughness value were analyzed using ANOVA. The number of attached cell was as follows, for root dentin specimen 16.7${\pm}$4.41, resin modified glass ionomer 14.0${\pm}$4.15, resin 8.13${\pm}$3.63, amalgam 0.72${\pm}$3.33(${\times}10^3$). Between root dentin and resin-modified glass ionomer, no significant difference was observed, but resin, amalgam showed a significant less cell numbers than for root dentin, resin modified glass ionomer cement. SEM examination expressed many cell surface attachment apparatus in root dentin and resin modified glass ionomer specimens. For resin specimen, cell attachment was observed but exposed less appratus. The average surface roughness value are following results. Dentin specimen 0.6972${\pm}$ 0.104, resin modified glass ionomer 0.0822${\pm}$0.009, resin 0.0875${\pm}$0.005, amalgam 4.2145${\pm}$0.985(${\mu}m$). Between root dentin, resin-modified glass ionomer, and resin, no significant difference was observed, but amalgam showed a significant more rough surface than other groups. When evlauated the interrelationship between cell attachment and surface roughness, therefore, there was weak reverse correlation.(pearson correlation : - 0.593) These results suggest that resin modified glass ionomer have the favorable healing potential when used for subgingival restoration. And for relationship between cell attachment and surface characteristics, further investigations were needed.

  • PDF

Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials

  • Lee, Ki-Sun;Shin, Myoung-Sik;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.350-357
    • /
    • 2017
  • PURPOSE. The object of the present study was to evaluate the shear bonding strength of composite to PEKK by applying several methods of surface treatment associated with various bonding materials. MATERIALS AND METHODS. One hundred and fifty PEKK specimens were assigned randomly to fifteen groups (n = 10) with the combination of three different surface treatments (95% sulfuric acid etching, airborne abrasion with $50{\mu}m$ alumina, and airborne abrasion with $110{\mu}m$ silica-coating alumina) and five different bonding materials (Luxatemp Glaze & Bond, Visio.link, All-Bond Universal, Single Bond Universal, and Monobond Plus with Heliobond). After surface treatment, surface roughness and contact angles were examined. Topography modifications after surface treatment were assessed with scanning electron microscopy. Resin composite was mounted on each specimen and then subjected to shear bond strength (SBS) test. SBS data were analyzed statistically using two-way ANOVA, and post-hoc Tukey's test (P<.05). RESULTS. Regardless of bonding materials, mechanical surface treatment groups yielded significantly higher shear bonding strength values than chemical surface treatment groups. Unlike other adhesives, MDP and silane containing self-etching universal adhesive (Single Bond Universal) showed an effective shear bonding strength regardless of surface treatment method. CONCLUSION. Mechanical surface treatment behaves better in terms of PEKK bonding. In addition, self-etching universal adhesive (Single Bond Universal) can be an alternative bonding material to PEKK irrespective of surface treatment method.

광조사 방식이 복합레진의 중합과 누출에 미치는 영향 (THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN)

  • 박종진;박정원;박성호;박주명;권태경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.158-174
    • /
    • 2002
  • Filtek$^{TM}$ Z-250(3M Dental Products, St. Paul., MN. USA) 광중합형 복합레진을 대상으로 다양한 광조사 방식이 중합수축, 중합도 및 미세누출에 미치는 영향을 알아보고자 하였다. VIP$^{TM}$(Bisco Dental Products, Schaumburg, IL, USA)를 이용하여 200, 400 및 600mW/$\textrm{cm}^2$의 일정한 광도로 중합시킨 세 군(V2, V4 및 V6군)과 200mW/$\textrm{cm}^2$의 광도로 3초간 중합시키고 5분간 방치 한 후 다시 600mW/$\textrm{cm}^2$의 광도로 중합시키는 pulse-delay 방식을 이용한 군(VPD군) 그리고 Optilux 501$^{TM}$(Demetron/Kerr, Danbury, CT, USA)을 이용하여 C-mode와 R-mode로 중합시킨 두 군(OC군, OR군) 등 모두 6개의 군으로 나누어 실험하였으며, 복합레진의 중합과 누출을 다음의 네 가지 방법으로 측정하였다. 첫째, V2, V4, V6, OC군은 60초간, OR군은 20초간 그리고 VPD군은 두번째 광조사를 60초간 시행하면서 시간에 따른 선형 중합수축을 Linometer(R&B, Daejeon, Korea)로 측정하였다. 둘째, V2, V4, V6, OC군은 각각 5, 10, 20, 40, 60초간 그리고 OR군과 VPD군은 정해진 조건에 따라 중합시킨 2mm 두께 시편의 바닥면에서 시료를 채취한 후 KBr method로 시편을 제작하고, FTIR spectrometer(IFS 120 HR, Broker, Karlsruhe, Germany)로 미반응 잔류단량체의 양을 계측하여 중합도를 측정하였다. 셋째, 두번째 실험과 같은 조건으로 중합시킨 2mm 두께 시편의 광조사면과 바닥면에서 중합 10분 후 미세경도 측정기(FM7, Future-Tech Co., Tokyo, Japan)로 500g의 하중을 10초간 가하여 Knoop Hardness Number(KHN) 값을 측정하였다. 끝으로, 90개의 발거치 치경부에 제5급 와동을 형성하고 V2군은 60초간, V4군은 40초간, V6군은 30초간 그리고 OC, OR, VPD군은 정해진 조건에 따라 중합시킨 후, methylene blue 용액에 침적시키고 종절단하여 법랑질과 상아질 변연의 미세누출 정도를 측정하였다. 중합수축. 중합도 및 미세경도 측정치는 one-way ANO-VA와 Duncan's multiple range test를, 변연누출 정도는 chi-square test를 이용, 통계처리하여 다음의 결과를 얻었다. . 중합수축의 정도는 VIP$^{TM}$(Bisco) 사용군에서 전체 조사광도가 높을수록 큰 경향을 보여 600mW/$\textrm{cm}^2$군에서 가장 크게 나타났고, 그 다음으로 Pulse-delay군, 400mW/$\textrm{cm}^2$군, 200 mW/$\textrm{cm}^2$군 순이었고, Optilux 501$^{TM}$(Demetron/Kerr) 사용군에서는 Continuous 방식이 Ramp 방식 보다 크게 나타났다. . 중합도와 미세경도 값은 공히, 전체 조사광도가 높을수록 높게 나타났으며 , 최종 중합도는 44.77~54.98%의 범위를, 미세경도 값은 34.10~56.30의 범위를 보였다. . 미세누출은 전반적으로 상아질 변연이 법랑질 변연에 비해 많았고, VIP$^{TM}$(Bisco) 사용 군에서는 광도가 높을수록 상아질 변연에서 미세누출이 증가하는 양상을 보였으며, 법랑질 변연에서는 Optilux 501$^{TM}$(Demetron/Kerr)의 Continuous 방식이, 상아질 변연에서는 Ramp 방식이 가장 적은 미세누출을 보였다.