• Title/Summary/Keyword: dental research

Search Result 4,635, Processing Time 0.03 seconds

Removable Partial Denture Using Anterior Implant-Supported Fixed Prostheses for Edentulous Patients: A Case Report

  • Lee, You-Jin;Bae, Eun-Bin;Jeong, Chang-Mo;Lee, Jin-Ju;Kim, Ji-Young;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • This case study was to report the possible increase in the denture retention and psychological relief using the implant-supported fixed prostheses in a completely edentulous patient. The implants were placed in the anterior portion of the mandible in a patient who had completely edentulous state following the extraction of residual abutment teeth, and consequently a distal extension removable partial denture was fabricated. The patient's adaptation and satisfaction to the new prosthesis was monitored and confirmed in terms of masticatory function and esthetics, by restoring the oral condition similar to initial status before the residual teeth extraction. After 6 months, radiographic examination confirmed that both the abutment teeth and the implants were stable and well maintained. Considering the relatively short clinical follow-up period, however, continuous long-term monitoring was required.

Current trends in intravenous sedative drugs for dental procedures

  • Yoon, Ji-Young;Kim, Eun-Jung
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • Anxiety and phobia in dental procedures are common deterrents for patients visiting the dental care unit. For these individuals, procedural sedation may aid in completion of dental treatments. In most cases, the patients are conscious during sedation, thereby allowing spontaneous ventilation. Intravenous sedation (IVS) is widely used during dental treatment to relieve patient anxiety. IVS is the most effective route of administration to achieve this goal, but it requires advanced training, more than that provided during undergraduate education. During IVS, rapid onset, repetitive drug administration, easy titration, and rapid recovery from sedation can be achieved. However, conscious sedation during IVS can result in deep sedation that can cause respiratory and cardiovascular depression. Therefore, the characteristics of intravenous sedatives should be known. The purpose of this review is to discuss the characteristics and usage of intravenous sedatives currently used for dental procedures.

Expression of osteoclastogenesis related factors in dental implant patients (치과 임플란트에서 골개조 관련인자의 발현에 관한 연구)

  • Ryu, Seong-Hee;Kim, Bang-Sin;Jung, Seung-Gon;Han, Man-Seung;Kook, Min-Suk;Ohk, Seung-Ho;Oh, Hee-Kyun;Park, Hong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.386-391
    • /
    • 2010
  • Introduction: Bone resorption is a unique function of osteoclasts. Osteoclasts are a specialized macrophage polykaryon whose differentiation is regulated principally by macrophage colony-stimulating factors, receptor activator of nuclear factor ${\kappa}B$ ligand (RANK) ligand, osteoprotegerin (OPG), and interleukins (IL). Reflecting the integrin-mediated signals, osteoclasts develop a specialized cytoskeleton that allows it to establish an isolated micro-environment between itself and the bone, wherein matrix degradation occurs by a process involving proton transport. The levels of IL-1, IL-6, OPG, and prostaglandin $E_2$ ($PGE_2$) expression were evaluated to study the correlations between dental implant teeth and the adjacent teeth. Materials and Methods: The exudate of the gingival crevice acquired from dental implants, adjacent teeth, opposite teeth and contralateral teeth of 24 patients. Results: 1. The levels of IL-1, IL-6, OPG and $PGE_2$ expression in dental implant teeth were higher than those of the contralateral teeth. 2. IL-1 revealed a higher expression level in the adjacent teeth than in dental implant teeth. 3. The dental implant teeth and adjacent teeth did not show a remarkable difference in the level of IL-1 expression. 4. All the other cytokines were strongly expressed in the dental implant compared to the adjacent teeth. Conclusion: These results suggest that there might be close correlation between dental implant teeth and adjacent teeth in terms of the expressions of cytokines that affect the development and regulation of osteoclasts.

The development of a learning management system for dental radiology education: A technical report

  • Chang, Hee-Jin;Symkhampha, Khanthaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.51-55
    • /
    • 2017
  • Purpose: This study was conducted to suggest the development of a learning management system for dental radiology education using the Modular Object-Oriented Dynamic Learning Environment(Moodle). Materials and Methods: Moodle is a well-known and verified open-source software-learning management system (OSS-LMS). The Moodle software was installed on a server computer and customized for dental radiology education. The system was implemented for teaching undergraduate students to diagnose dental caries in panoramic images. Questions were chosen that could assess students' diagnosis ability. Students were given several questions corresponding to each of 100 panoramic images. Results: The installation and customization of Moodle was feasible, cost-effective, and time-saving. By having students answer questions repeatedly, it was possible to train them to examine panoramic images sequentially and thoroughly. Conclusion: Based on its educational efficiency and efficacy, the adaptation of an OSS-LMS in dental school may be highly recommended. The system could be extended to continuing education for dentists. Further studies on the objective evaluation of knowledge acquisition and retention are needed.

Immediate effects of mandibular posterior displacement on the pharyngeal airway space: A preliminary study

  • Choi, Yeonju;Kim, Yong-Il;Kim, Seong-Sik;Park, Soo-Byung;Son, Woo-Sung;Kim, Sung-Hun
    • The korean journal of orthodontics
    • /
    • v.50 no.2
    • /
    • pp.129-135
    • /
    • 2020
  • Objective: This study aimed to evaluate the immediate effects of mandibular posterior displacement on the pharyngeal airway space (PAS) by using cephalometric evaluations and to investigate how the surrounding structures are schematically involved. Methods: In this retrospective study, 38 subjects with functional Class III malocclusion and two lateral cephalograms were selected. The first lateral cephalogram was taken with the mandible in the habitual occlusal position, and the second in anterior edge-to-edge bite. Paired t-test was used to analyze changes in the PAS, hyoid bone, tongue, and soft palate, followed by mandibular posterior displacement. Pearson's correlation analysis was used to determine the relationship between the amount of mandibular posterior displacement and other variables. Results: A statistically significant decrease was observed in the PAS following mandibular posterior displacement. Along with mandibular posterior displacement, the tongue decreased in length (p < 0.001) and increased in height (p < 0.05), while the soft palate increased in length, decreased in thickness, and was posteriorly displaced (p < 0.001). The hyoid bone was also posteriorly displaced (p < 0.05). There was no correlation between the amount of mandibular posterior displacement and the measured variables. Conclusions: The PAS showed a statistically significant decrease following mandibular posterior displacement, which was a consequence of retraction of the surrounding structures. However, there were individual variances between the amount of mandibular posterior displacement and the measured variables.

Color distribution of maxillary primary incisors using a dental spectrophotometer in Korean children (치과용 분광광도계를 이용한 상악 유전치의 색조 분포에 관한 연구)

  • Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon
    • The Journal of the Korean dental association
    • /
    • v.58 no.8
    • /
    • pp.476-485
    • /
    • 2020
  • The purpose of this study was to analyze the color distribution of the maxillary primary central and lateral incisors using a dental spectrophotometer. Color measurements of maxillary primary central and lateral incisors of 32 pediatric patients aged 2 to 6 years were performed using SpectroShade Handy Dental Type 713000 (Serial No. HDL2678, MHT, Verona, Italy) by one researcher in the same clinic. CIE L*, a*, b* values of total surfaces and cervical, middle, incisal region were recorded. L* values were higher and a* values were lower in the primary central incisors than those in primary lateral incisors, but b* values didn't show statistical difference. L* values of the middle region were the highest, and a* and b* values decreased from the cervical region to the incisal region. There were significant color differences between each region, and ΔE*ab between each region were greater than ΔE*ab between the primary central and lateral incisors. For esthetic restorations of primary incisors, it is necessary to consider the color differences between each region rather than those between the primary central and lateral incisors.

  • PDF

Considerations for the Survival of Complete Arch Implant-Supported Zirconia Restorations; Status of Antagonistic Arches and Stress Distribution on Frameworks: A Case Report

  • Choi, Jung-Yoo;Sim, Jae-Hyuk;Yeo, In-Sung Luke
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • This report describes two cases of complete arch implant-supported restorations. The first patient had seven dental implants in each arch with monolithic zirconia frameworks. At four weeks' follow-up, the one-piece maxillary framework was fractured, which was re-designed and re-fabricated using laser-sintered cobalt-chrome alloy. The second patient had four implants in the mandible only. A mandibular monolithic zirconia framework and a maxillary conventional complete denture were fabricated and delivered. At five years' follow-up, the patient reported no significant discomfort. Careful consideration and monitoring of the status of antagonistic arches and stress distribution on zirconia frameworks were suggested for complete arch implant-supported fixed restorations.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

A clinical study of alveolar bone quality using the fractal dimension and the implant stability quotient

  • Lee, Dae-Hyun;Ku, Young;Rhyu, In-Chul;Hong, Jeong-Ug;Lee, Cheol-Woo;Heo, Min-Suk;Huh, Kyung-Hoe
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • Purpose: It has been suggested that primary implant stability plays an essential role in successful osseointegration. Resonance frequency analysis (RFA) is widely used to measure the initial stability of implants because it provides superior reproducibility and non-invasiveness. The purpose of this study is to investigate whether the fractal dimension from the panoramic radiograph is related to the primary stability of the implant as represented by RFA. Methods: This study included 22 patients who underwent dental implant installation at the Department of Periodontology of Seoul National University Dental Hospital. Morphometric analysis and fractal analysis of the bone trabecular pattern were performed using panoramic radiographs, and the implant stability quotient (ISQ) values were measured after implant installation using RFA. The radiographs of 52 implant sites were analyzed, and the ISQ values were compared with the results from the morphometric analysis and fractal analysis. Results: The Pearson correlation showed a linear correlation between the ISQ values of RFA and the parameters of morphometric analysis but not of statistical significance. The fractal dimension had a linear correlation that was statistically significant. The correlation was more pronounced in the mandible. Conclusions: In conclusion, we suggest that the fractal dimension acquired from the panoramic radiograph may be a useful predictor of the initial stability of dental implants.

DEVELOPMENT OF MICROPOROUS CALCIUM PHOSPHATE COATED NERVE CONDUIT FOR PERIPHERAL NERVE REPAIR (말초신경 재건을 위한 인회석 박막 코팅 미세공성 신경재생관(nerve conduit)의 개발)

  • Lee, Jong-Ho;Hwang, Soon-Jeong;Choi, Won-Jae;Kim, Soung-Min;Kim, Nam-Yeol;Lee, Eun-Jin;Ahn, Kang-Min;Myung, Hoon;Seo, Byoung-Moo;Choi, Jin-Young;Choung, Pill-Hoon;Kim, Myung-Jin;Kim, Hyun-Man
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.151-156
    • /
    • 2003
  • This study was performed to develop a useful nerve conduit which provides favorable environment for Schwann cell viability and proliferation. Milipore membrane of $0.45{\mu}m$ pore size was selected because it permits nutritional inflow from the outside of the conduit and prevents from invading the fibrotic tissue into the conduit. The membrane was rolled and sealed to form a conduit of 2mm diameter and 20mm length. To improve the axonal regeneration and to render better environment for endogenous and exogenous Schwann cell behaviour, the microgeometry and surface of conduit was modified by coating with thin film of calcium phosphate. Cellular viability within the conduit and attachment to its wall were assessed with MTT assay and SEM study. Milipore filter conduit showed significantly higher rate of Schwann cell attachment and viability than the culture dish. However, the reverse was true in case of fibroblast. Coating with thin film of low crystalline calcium phosphate made more favorable environment for both cells with minimal change of pore size. These findings means the porous calcium phosphate coated milipore nerve conduit can provide much favorable environment for endogenous Schwann cell proliferation and exogenous ones, which are filled within the conduit for the more advanced strategy of peripheral nerve regeneration, with potential of reducing fibrotic tissue production.