• Title/Summary/Keyword: dental prosthetic

Search Result 483, Processing Time 0.025 seconds

The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

  • Sagsoz, Omer;Demirci, Tevfik;Demirci, Gamze;Sagsoz, Nurdan Polat;Yildiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.417-422
    • /
    • 2016
  • PURPOSE. The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS. Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples ($8{\times}8{\times}1mm$) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (${\alpha}=.05$). RESULTS. The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION. Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics.

Full-mouth rehabilitation of skeletal anterior open bite with severely decayed dentition: A case report (심한 우식을 동반한 골격성 전치부 개방 교합 환자의 전악 수복 증례)

  • Kim, Seong-A;Noh, Kwantae;Pae, Ahran;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.79-87
    • /
    • 2017
  • The open bite malocclusion is a common clinical entity and has multifactorial causes. Development of effective treatment plan and management is dependent on proper diagnosis. The skeletal open bite patient requires a coordinated orthodontic and orthognathic surgical approach to achieve stable occlusion, acceptable esthetics, and improved function. But in case of open bite with severely decayed dentition, restoration in the entire dentition is necessary. Using the facial analysis and diagnostic wax-up, the most effective treatment was prosthetic rehabilitation. The provisional restorations were fabricated to satisfy esthetic and functional requirements, which result in the uniformly distributed occlusal force, anterior and canine guidance. The inter-arch relationship, labio-dental harmony, and the soft tissue aspect, which is important to estimate the longevity were evaluated. Definitive restorations of monolithic zirconia were made by replicating provisional restorations by using the latest CAD/CAM technology. They were delivered to the patient and clinical follow-up observation was satisfactory.

Various factors influencing on the satisfaction of complete denture wearers (총의치 환자의 만족도에 영향을 미치는 다양한 요인)

  • Byun, Jin-Soo;Cho, Lee-Ra;Kim, Dae-Gon;Huh, Yoon-Hyuk;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.53-63
    • /
    • 2014
  • Growing of number of elderly populations, which may be caused by improved quality of life and decreased the percentage of mortality. Although there is a declining rate of the edentulous patients, more patients are advancing into older age groups, and the substantial number of edentulous patients are increasing. For these edentulous patients, complete denture cannot substitute natural teeth, but it is a staple prosthetic treatment. Generally, the success of dentures has been evaluated on the basis of whether or not patients comfortable and were able to masticate with their dentures. Acceptance of complete denture is complex for patients and related to psychological factors of patients, physical state, and the technical quality of dentures. In addition to that, many factors influence to satisfaction of patients to the complete dentures. In this review article, evaluate various factors related on satisfaction of denture wearers and methods of evaluate satisfaction.

Reconstruction of upper anterior by implant using customized zirconia abutment and all ceramics: a clinical report (맞춤형 지르코니아 지대주와 완전도재관을 이용한 상악 전치부 임플란트 보철 수복)

  • Kim, Ja-Yeong;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.81-92
    • /
    • 2014
  • It is so hard to obtain optimal anterior esthetics in the implant prosthesis. This is not only because of hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also because of prosthetic limitation related to marginal exposure of metal abutment and metal ceramics and low transillumination. In this case, guided soft tissue healing is obtained using a long term provisional restoration with soft and hard tissue augmentation or immediate implantation. Then, this healed tissue is transferred to final master model using a customized impression coping and the implant is restored with a customized zirconia abutment and a all ceramics. This case presents satisfying result esthetically and functionally.

Prosthetic treatment with correcting edentulous maxillomandibular relation (무치악치조제의 개선을 통한 보철치료)

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuck;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.339-349
    • /
    • 2014
  • If the maxillomandibular relationship is unstable or requires treatment for improved function and esthetics, the first treatment objective is to provide stable occlusal contacts. The patient has moderate mental retardation. Due to inadequate vertical overjet, horizontal arch malrelation and excessive tooth loss, full mouth rehabilitation was required. The purpose of treatment planning is to establish physiologic maxillomandibular relation. Using cephalometrics for occlusal analysis is an aid to make a decision. The amount of horizontal bone reduction was calculated with evaluating soft tissue profile. After provisional denture placement, healing of the surgical site and newly adapted arch relationship was evaluated. The patient satisfied with esthetics and showed stable holding contacts. Periodic examination is needed to exclude occlusal disharmony.

Treatment Protocol for Cleft Lip and/or Palate Children in Kyushu University Hospital

  • Suzuki, Akira
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.15 no.2
    • /
    • pp.69-82
    • /
    • 2012
  • Our Team Approach consists of following five stages; (1) Peri-natal care until lip repair After ultrasound diagnosis, some obstetricians recommend the mother with CL/P fetus to undergo prenatal counseling in our CLP clinic. On the day the CL/P baby was born, our oral surgeon, nurse, and pedodontist visit the maternity clinic, and take counseling and take impression for a feeding plate. The cheiloplasty is performed in three months old. (2) From lip repair to palatal repair At one year of age, Otorhinolaryngologist checks middle-ear disease. Palatoplasty is carried out at 1.5 - 2 years old. (3) In deciduous and early mixed dentitions Speech is the most important issue in social life for the CL/P subjects, therefore the training of velopharyngeal function is essential. Orthodontist monitors dentofacial development from 5 years of age. In the case of severe maxillary under-growth or severe collapse, maxillary protractor or lateral expansion is indicative, respectively. In early mixed dentition, upper central incisor on the cleft area erupts with some torsion, and then the traumatic occlusion with tooth torsion must be corrected. (4) In mixed dentition Right before the eruption of upper canines, secondary bone grafting is performed. One year prior to the operation, maxillary fan-type expansion is carried out to correct the collapse of maxillary segments. Following the surgical operation, the erupted canine will be moved into the transplanted bone to avoid alveolar resorption. (5) In permanent dentition Final tooth alignment is carried out after eruption of second molars. Some cases may require orthognathic surgery after physical maturation. Prosthetic oral rehabilitation including the dental-implant is carried out after age eighteen.

  • PDF

A COMPARATIVE STUDY ON THE SEVERAL FACIAL MEASUREMENT METHOD FOR VERTICAL DIMENSION (수직고경 설정을 위한 안면 계측방법에 관한 비교 연구)

  • Park, Jong-Hwan;Oh, Sang-Chun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.75-84
    • /
    • 1995
  • This study was designed as a reference of vertical dimension in prosthetic treatment. The author analyzed six facial measurements, namely, (1) the height of lower face at maximum intercuspal position, (2) the height of lower face at resting position, (3) midface, (4) external ear and lateral wall of orbit, (5) interpupillary distance, (6) distance between pupil and mouth in the 100 Won-kwang Univ. Dental collage students(50 : male, 50 : female), who have normal occlusion, no posterior prosthesis, no experience of orthodontic treatment, and no deformity of facial soft tissue and no temporomandibular dysfunction. The results of this study were as follows : 1. The length of midface was shortest and the inter-pupillary distance was longest in both male and female. 2. The length difference with the length of midface and lower face at maximum intercuspal position was 5.64mm in male and 2.23mm in female, so the lower face was longer, 3. The facial measuring component, similar to lower face at maximum intercuspation, was the length of between medial wall of external ear and lateral wall of orbit. It's difference was 1.3mm in male, 1.77mm in female, and the lower face was shorter. 4. The difference of lower facial length in resting position and maximum intercuspation was 2.48mm in male, 2.24mm in female, the length of resting position was therefore longer. 5. The most clost correlation with the height of maximum intercuspal positioning lower face was resting lower face in both groups.

  • PDF

THE INFLUENCE OF THE INITIAL STABILITY AFTER DENTAL IMPLANT INSTALLATION ON THE OSSEOINTEGRATION (임프란트 식립시 초기 안정성이 골유착에 미치는 영향)

  • Lee, Young-Hoon;Kim, Yeo-Gab;Choi, Byung-Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.518-528
    • /
    • 2008
  • Purpose: The long-term experience of using osseointegrated implants for prosthetic rehabilitation of the edentulous patients shows that high success rates can be predictably achieved. Primary implant stability has been identified to be a prerequisite to achieve osseointegration. In this study, we set up the amount of removed bone so that it differed on implant installation site for each group. The influence of each initial stability on secondary stability and osseointegration was compared with time lapse using resonance frequency analysis and histomorphometric analysis. Materials and methods: A total 27 US $II^{(R)}$ (Osstem, Korea) implants were placed in the mandibular edentulous area of 3 beagle dogs. The implant site was prepared by the conventional technique with drills, and three experimental groups were divided into under-drilling group, normal-drilling group and over-drilling group. The Implant Stability Quotient (ISQ) was measured at intervals of immediately, 4, 8, 12 weeks after placement using $Osstell^{(R)}$ mentor RFA. After the animals were sacrificed, histomorphometric evaluation was executed for measuring BIC and BD. Results: 1) The under-drilled group showed most high ISQ value for whole experiment period. 2) Bone-to-implant-contact(BIC) showed the tendency to be increased gradually as the experiment period passed except the 8 weeks of the normal group. 3) The under-drilled group showed most high bone density(BD) level for whole experiment period, and it was expressed the aspect to be increased gradually according to an experiment period passage in the average of all group. 4) Resonance frequency analysis and histomorphometric analysis are presumed by generally proportional. Conclusions: As this research result, it seems that there are some correlation between resonance frequency analysis and histomorphometric analysis. As are accomplished osseointegration stably so that more superior at the region which the overpressure comes to add, it will be applicable method in clinical field.

A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods (다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구)

  • Kim, Doo-Yeol;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND PRELOAD OF DIFFERENT CONNECTION TYPES IMPLANT WITH INITIAL CLAMPING (임플랜트의 체결방식에 따른 초기조임력에 의한 응력분포 및 전하중에 관한 연구)

  • Lee Bum-Hyun;Chun Heoung-Jae;Lee Soo-Hong;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • Statement of problem: One of common problems associated with single teeth dental implant prosthetic is the loosening of screws that retain the implants. Purpose: The maintenance of screw joint stability is considered a function of the preload achieved in the screw when the suggested initial tightening torque is applied. The purpose of this study was to investigate acquired preload after initial clamping torque for estimating screw joint stability. Material and methods: A comparative study on the effect of initial clamping of two types of implant systems with different connections was conducted Three dimensional non-linear finite element analysis is adopted to compare the characteristics of screw preloads and stress distributions between two different types of implant systems composed with abutment, screw, and fixture under the same loading and boundary conditions. Results: 1. When the initial clamping torque of 32Ncm was applied to the implant systems, all types of implants generated the maximum effective stress at the first helix region of screw. 2. Morse taper connection types of implants generate lower stress distributions compared to those by butt joint connection types or implants due to large contact surface between abutment and fixture. 3. The internal types of implant systems with friction grip type implant systems have higher resistance to screw loosening than that of the external types of implant systems since the internal types of implant systems generated larger preload than that generated by the external types for the same tightening moments.