• Title/Summary/Keyword: dental prosthetic

Search Result 484, Processing Time 0.029 seconds

The Effect of Head Posture Change on Initial Occlusal Contacts (두부의 자세 변화가 초기 교합접촉에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.195-204
    • /
    • 1995
  • The purpose of this study was to evaluate effect of head posture change on initial occlusal contacts through measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture. Two special devices were designed and constructed. Mandibular movement replicator was used to assess reliability of the K6 diagnostic system(MKG; Myo-tronic Inc, Seatle, USA) and head posture calibrator was used to maintain the constant head posture during experiment. We measured difference of distance between initial occlusal contact and maximum intercuspal position with MKG in upright, supine, 45 degrees extension, 30 degrees flexion, 30 degrees right and left bending postion of the head. The Frankfurt horizontal plane was used as a reference plane. 21 adults aged from 23 to 25 were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. The obtained results were as follows : The mean absolute distances between initial occlusal contact and maximum intercuspal postion were 0.39(0.18mm in the upright position, 0.65(0.37mm in the supine position, 0.59(0.33mm in the 45 degree extension, 0.70(0.53mm in the 30 degrees flexion, 1.12(1.10mm in the 30 degrees right bending and 1.94(0.67mm in the 30 degrees left bending of the head. The positions of the initial occlusal contacts have a tendency to locate anterior, left and inferior to maximal intercuspal position in upright position, posterior and inferior in supine position and 45 degrees extension, anterior and inferior in 30 degrees flexion, right and inferior in 30 degrees right bending, and left and inferior in 30 degrees left bending of the head. There were significant differences among the initial occlusal contacts in each head postures(P<0.0001). Therefore, we need to check initial occlusal contacts in the altered head posture during occlusal analysis and adjustment of occlusal appliance and dental occlusion for diagnosis and treatment of temporomandibular disorder.

  • PDF

Fixed Prosthetic Restoration in an Edentulous Patient with NobelGuideTM System (양악 무치악 환자에서 NobelGuideTM 시스템을 이용한 고정성 임플란트 보철수복)

  • Shin, Hyoung-Joo;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.243-253
    • /
    • 2009
  • This report described a technique utilizing a computer-aided design (CAD) /computer-aided machining (CAM) - guided surgical implant placement and prefabricated fixed complete denture for an immediately loaded restoration. A patient with an edentulous maxilla and mandible received 6 implants in maxilla and 6 implants in the mandible using CAD/CAM surgical templates. Prefabricated provisional maxillary and mandibular implant supported fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics, function during 6 months. Definitive prostheses were fabricated.

Consideration on the esthetic problems from implant cases (임플란트 증례에서 발생하는 심미적 문제점들에 관한 고찰)

  • Lee, Dong-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.39-48
    • /
    • 2015
  • The critical factors affecting the esthetics of anterior implants can be summarized as following: 1) Correct positioning of implant fixture, 2) Enough amount of alveolar bone, 3) Optimum volume of soft tissue. The position of implant is probably the most important factor in obtaining esthetic treatment outcome. The 3-dimensional orientation of implant is determined by the position on the alveolar ridge and its direction. Clinicians often try to mimic natural teeth when fabricating restorations. During the course of esthetic diagnosis and treatment, however, one should not forget to consider the correlation between facial pattern, lips, gingiva, alveolar ridge, as well as remaining dentition. Since anterior region is biologically unfavorable when compared with posterior region, one minor discrepancy in positioning of implant can cause esthetically undesirable treatment outcome. If one understands the biological and prosthetic meaning of implant' s 3-dimensional position, he or she can achieve superior esthetic outcome in anterior region.

Comparison of the Oral Health Behavior and the Oral Health Status According to Residential Areas in Korean Adults: based on 2012 KNHANES data (거주 지역 간 성인의 구강건강행태 및 구강건강상태 비교)

  • Hwang, Chan-Hui;Park, Jong;Ryu, So-Yeon;Choi, Seong-Woo
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.33-43
    • /
    • 2015
  • Purpose: This study aimed to evaluate and compare the oral health behavior in adults and their oral health status according to their residential area. Methods: The date of 'The fifth Korea National Health and Nutrition Examination Survey 2012' was analyzed for this study. This study were adults over the age of 18 who participated in interviews with the use of a questionnaire and oral examinations. Of those, 4,273 who met all the variables necessary were selected for the final analysis. The residential areas were categorized into 'metropolitan city', 'city', and 'rural area' based on Dong, Eup and Myon as administrative districts. Results: Adjusted odds ratio of oral health behavior according to residential area, self-recognition of oral health status for subjects in rural areas was 0.75(0.59-0.96), using oral hygiene devices for those in rural areas was 0.75(0.63-0.88). Adjusted odds ratio of oral health status according to residential area, periodontal disease in rural areas was 1.97(1.62-2.41), the necessity of prosthetic treatment in subjects in rural areas was 1.27(1.01-1.60). Conclusion: It was discovered that there was a difference between the oral health behavior and oral health status of adults according to residential area. Therefore, to enhance oral health status, programs for which the characteristics of areas with such differences were considered should be developed and consistent research on strategies to reduce the gaps in the oral health status should be made.

Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws

  • Carlsson, Gunnar E.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.245-252
    • /
    • 2014
  • PURPOSE. To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. MATERIALS AND METHODS. Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. RESULTS. Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. CONCLUSION. In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.

A CASE REPORT ABOUT CORRECTION OF IMPLANT POSITION AT HORIZONTAL PLANE AFTER CORTICOTOMY (피질골 절단술을 이용한 수평면에서의 임플란트의 위치 교정에 대한 치험례)

  • Choi, Bin;Oh, Hae-Soo;Kim, Jin-Chul;Kil, Yong-Gab;Kim, Kyoung-Soo;Kim, Jwa-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • Preface: Dental implant is important method that may solve the mastication, occlusion, esthetic, temporomandibular joint, and psychologic problem in oral and maxillofacial surgery. It is ideal that all of the implant are well positioned by adequate technique. By the way it‘s not always possible because of some anatomic, physiologic factor. In this case, If the implant can be moved to adequate position, it may be possible more esthetically and implanted patients more satisfied, but the majority of Implantists and orthodontists have thought that it is not possible. However, Implant, in fact, can be moved. and thus we can overcome the limit of implantation more. The aim of the present study was to evaluate the possibility of implant movement after corticotomy. Case report: Patient missed the upper right first molar. and implantation was done after completion of socket healing. We wait six months for osseointegration. Then, corticotomy was done under local anesthesia and close coil was used for orthodontic force. After traction during 3 weeks, we find the change of implant position at horizontal plane. we can not see the degenerative change on adjacent structure and tracted implant. there is a clinical mobility on upper right second premolar that used for anchorage but it subside spontaneously at the timing of prosthetic restoration without additional treatment. Discussion: As we could have some knowledge with this experiment, we report the case of implant movement after corticotomy and suggest a method about more esthetic implant treatment with a review of literature.

A case report about the reconstruction procedures of the previously failed cylinderical implants site using distraction osteogenesis

  • Lee, Jung-Tae;Park, Shin-Young;Yi, Yang-Jin;Kim, Young-Kyun;Lee, Hyo-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.2
    • /
    • pp.84-89
    • /
    • 2015
  • We report the eventually successful treatment of a huge bone defect and peri-implantitis following reconstruction of a previously failed intra-mobile cylinder implant system (IMZ) implant site using distraction osteogenesis (DO). In the anterior mandible, two IMZ implants failed and surgical debridement was performed in accordance to the patient's needs. Thereafter, mobility and suppuration were decreased and the patient visited the dental clinic on a regular basis for oral health maintenance. However, the inflammation did not resolve, and the bone destruction around the implants progressed for 4 years. Finally, the implants failed and a severe bone defect remained after implant removal. To reconstruct the bone defects, we attempted bone graft procedures. Titanium mesh was unsuccessfully used to obtain bone volume regeneration. However, DO subsequently was used to obtain sufficient bone volume for implant placement. The new implants were then installed, followed by prosthetic procedures. In conclusion, progression of peri-implantitis could not be arrested despite surgical intervention and repeated maintenance care for 3 years. Reconstruction of the peri-implantitis site was complicated due to its horizontal and vertical bone defects. Lesions caused by implant failure require an aggressive regenerative strategy, such as DO. DO was successful in reconstruction of a peri-implantitis site that was complicated due to horizontal and vertical bone defects.

EFFECT OF GOLD ELECTRODEPOSIT OF PD-AG, NI-CR ALLOYS ON THE COLOR OF VENERRED RESIN (Pd-Ag 및 Ni-Cr 합금의 금 전착이 전장 레진의 색채에 미치는 영향)

  • Yang, Hong-So;Park, Yeong-Joon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.645-661
    • /
    • 1995
  • As the mechanical property of composite resin improved, composite resin has been widely used esthetic dentistry. In the field of esthetic dentistry, the color of prosthetic material is very important. The purpose of this study was to evaluate the color difference of specimens, by the types of alloys and gold electrodeposit. Experimental groups were as follows : Group Prec : Au-Pt alloy with no gold coating and no resin veneer. Group Semi : Pd-Ag alloy with no gold coating and no resin veneer. Group BAse : Ni-Cr alloy with no gold coating and no resin veneer. Group Gsem : Pd-Ag alloy with no gold coating and no resin veneer. Group Gbas : Ni-Cr alloy with no gold coating and no resin veneer. Group PreR : Resin veneer on the Pd-Ag alloy without gold coating. Group SemR : Resin veneer on the Pd-Ag alloy without gold coating. Group GbsR : Resin veneer on the Ni-Cr alloy with gold coating Group BasR : Resin veneer on the Ni-Cr alloy without gold coating. In this study, colors of metal surfaces and veneered resins were evaluated by the CIE $L^{*}a^{*}b$ system. The results obtained were as follows : 1. different alloy types and gold coating make the $L^{*}a^{*}b$ system. 2. The ${\Delta}E^*$ab value between groups semi and Base was less than 1.5 and there was no $a^*$ and $b^*$ value difference between groups Gsem and Gbas 3. The values of $L^*$ and $a^*$ ain groups GsemR and GbasR were so similar that the ${\Delta}E^*$ab value was as small as 0.58. 4. In resin specimens with gold coated semiprecious or base alloys showed yellower and redder deviation than the resin specimens with precious alloy. 5. The ${\Delta}E^*$ab values between goups PreR-GsemR and groups PreR-GbasR were as small as 2.68 and 2.22 respectively.

  • PDF

THE CLINICAL STUDY OF THE EFFECT OF OCCLUSAL PLANES ON THE STOMATOGNATHIC SYSTEM I. THE CONSIDERATION OF OCCLUSAL PLANES USING PANORAMIC VIEWS (교합평면이 악구강계에 미치는 영향에 대한 임상적 연구 I. Panoramic View를 이용한 교합평면의 검토)

  • Jo, Byung-Woan;Ahn, Sang-Hun;Kim, Jong-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.705-717
    • /
    • 1995
  • In clinical prosthetic dentistry the occlusal planes were represented to the dental arch form sagittally and composed of the occlusion morphologically. From now on the determinations of the occlusal planes were done through the facebow transfer and the cephalometric radiography, but they were not exact method for the diagnosis of the stomagnathic function. The purpose of this study is to examine the sagittal characteristics of occlusal planes using panoramic view between the normal subjects and the subjects with stomatognathic dysfunction. 60 normal subjects and 16 subjects with stomatognathic dysfunction were slectec for this investigation. We measured the inclination of occlusal planes to Frankfurt Horizontal plane. The occlusal planes were divided into 4 groups : 1) The plane between the midpoint of upper central incisor and the mesiobuccal cusp of upper 1st molar, 2) The plane between the midpoint of upper central incisor and the mesiobuccal cusp of upper 2nd molar, 3) The plane between the midpoint of upper central incisor and the distobuccal cusp of upper 2nd molar, 4) The plane between the mesiobuccal cusp of 1st molar and the distobuccal cusp of 2nd molar. The results were as follows : 1) The occlusal planes could be determined very easy by using panoramic view, 2) Among the angles between the occlusal planes and the FH plane, the angles related with the 2nd molar were more steep than those of the 1st molar. The angle between the 1st molar and the 2nd molar is the most steep in the other angles. 3) In the angles between occlusal planes and FH plane, the subjects with stomatognathic dysfunction were more significant steep(p<0.05) than the normal subjects.

  • PDF

Faculty-supervised measurements of the face and of mandibular movements on young adults

  • Woelfel, Julian B.;Igarashi, Takayoshi;Dong, Jin-Keun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.483-490
    • /
    • 2014
  • PURPOSE. The purpose of this study was to determine the average facial proportions and mandibular movement capacity of 316 first-year dental students who carefully recorded them on each other. MATERIALS AND METHODS. This early exacting clinical experience was closely supervised by the authors in Columbus, Ohio during 1969-70. Five vertical and six horizontal distances were measured on each subject's face. An ala-tragus line and an occlusal line were drawn on the left side of the face to determine if these two lines were parallel. Measurements of mandibular movements involved maximum normal and hinge opening at the incisors and maximum amounts of right, left lateral and protrusive excursions of the mandible. RESULTS. The ala width and distance between the tips of upper right and left canine cusps averaged (35.2 mm and 34.8 mm) but with very large individual variations. The distance between ala to occlusal plane lines was 29.9 mm at the tragus and 31.3 mm near the ala. The angle between orbitale and ala-tragus averaged 13.6 degrees. CONCLUSION. The upper lip length was the most variable and the distance between the pupils was the most stable of the eleven facial measurements. The ala-tragus line and the occlusal plane lines were for all practical purposes parallel. Maximum jaw opening averaged 51.2 mm which was 3.0 times larger than maximal hinge opening of 17.2 mm. The maximum right plus left side jaw excursions (9.2 and 9.4 mm) totaled 18.6 mm, 2.3 times more than the 8.0 mm mean maximum forward protrusion.