• 제목/요약/키워드: dental materials

검색결과 3,544건 처리시간 0.027초

Comparative analysis of the in vivo kinetic properties of various bone substitutes filled into a peri-implant canine defect model

  • Jingyang Kang;Masaki Shibasaki;Masahiko Terauchi;Narumi Oshibe;Katsuya Hyodo;Eriko Marukawa
    • Journal of Periodontal and Implant Science
    • /
    • 제54권2호
    • /
    • pp.96-107
    • /
    • 2024
  • Purpose: Deproteinized bovine bone or synthetic hydroxyapatite are 2 prevalent bone grafting materials used in the clinical treatment of peri-implant bone defects. However, the differences in bone formation among these materials remain unclear. This study evaluated osteogenesis kinetics in peri-implant defects using 2 types of deproteinized bovine bone (Bio-Oss® and Bio-Oss/Collagen®) and 2 types of synthetic hydroxyapatite (Apaceram-AX® and Refit®). We considered factors including newly generated bone volume; bone, osteoid, and material occupancy; and bone-to-implant contact. Methods: A beagle model with a mandibular defect was created by extracting the bilateral mandibular third and fourth premolars. Simultaneously, an implant was inserted into the defect, and the space between the implant and the surrounding bone walls was filled with Bio-Oss, Bio-Oss/Collagen, Apaceram-AX, Refit, or autologous bone. Micro-computed tomography and histological analyses were conducted at 3 and 6 months postoperatively (Refit and autologous bone were not included at the 6-month time point due to their rapid absorption). Results: All materials demonstrated excellent biocompatibility and osteoconductivity. At 3 months, Bio-Oss and Apaceram-AX exhibited significantly greater volumes of formation than the other materials, with Bio-Oss having a marginally higher amount. However, this outcome was reversed at 6 months, with no significant difference between the 2 materials at either time point. Apaceram-AX displayed notably slower bioresorption and the largest quantity of residual material at both time points. In contrast, Refit had significantly greater bioresorption, with complete resorption and rapid maturation involving cortical bone formation at the crest at 3 months, Refit demonstrated the highest mineralized tissue and osteoid occupancy after 3 months, albeit without statistical significance. Conclusions: Overall, the materials demonstrated varying post-implantation behaviors in vivo. Thus, in a clinical setting, both the properties of these materials and the specific conditions of the defects needing reinforcement should be considered to identify the most suitable material.

임상가를 위한 특집 3 - 기능별 뼈이식재의 임프란트 적용방법 (Clinical application of bone graft materials in dental implant)

  • 안강민
    • 대한치과의사협회지
    • /
    • 제48권4호
    • /
    • pp.275-279
    • /
    • 2010
  • Dental implant restoration in partial or full edentulous state has become the standard treatment in recent years. Bone graft with guided bone regeneration technique has been regarded as one of the most reliable methods to restore the bone defect area due to periodontal disease or dental trauma. Bone graft materials and membrane are the essential component of guided bone regeneration; however, a variety of bone graft materials confuse us in implant dentistry. Autogenous bone is the recognized standards in implant dentistry owing to its osteogenesis potential. Despite of its disadvantages, grafting autogenous bone is the most reliable methods. Even though the development of new bone grafts materials, autogenous bone is useful in exposed implant thread and total lack of buccal or lingual bone. Allogenic, xenogenic and synthetic bone have the osteoconductive and osteoinductive potential. These materials could be used successfully in self-contained cavity such as sinus cavity and three-wall defects. In this article, application of bone graft material is suggested according to the function of bone graft materials.

Color stability of provisional restorative materials with different fabrication methods

  • Song, So-Yeon;Shin, Yo-Han;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.259-264
    • /
    • 2020
  • PURPOSE. The aim of this study was to investigate and compare the color stability of provisional restorative materials fabricated by 3D printing, dental milling, and conventional materials. MATERIALS AND METHODS. For the experimental groups, two commercially available 3D-printing provisional resins (E-Dent 100; EnvisionTEC GmbH, Germany & VeroGlaze™; Stratasys®, USA), two dental milling blocks (PMMA Disk; Yamahachi Dental Co., Japan & Telio®CAD; Ivoclar Vivadent AG, Liechtenstein), and two conventional materials (Alike™; GC Co., Japan & Luxatemp automix plus; DMG, Germany) were used. The water sorption and solubility test were (n=10, respectively) carried out according to ISO4049:2000 (International Standards Organization, Geneva, Switzerland). For the color stability test (n=10), coffee and black tea were used as staining solutions, and the specimens were stored for 12 weeks. Data were analyzed by one-way ANOVA and Tukey's HSD using SPSS version 22.0 (SPSS Inc. Chicago, IL, USA) (P<.05). RESULTS. Alike and Veroglaze showed the highest values and Luxatemp showed the lowest water sorption. In the color stability test, the ΔE of conventional materials varied depending on the staining solution. PMMA milling blocks showed a relatively low ΔE up to 4 weeks, and then significantly increased after 8 weeks (P<.05). 3D-printed materials exhibited a high ΔE or a significant increase over time (P<.05). CONCLUSION. The degree of discoloration increased with time, and a visually perceptible color difference value (ΔE) was shown regardless of the materials and solutions. PMMA milled and 3D-printed materials showed more rapid change in discoloration after 8 weeks.

Comparative analysis of transmittance for different types of commercially available zirconia and lithium disilicate materials

  • Harianawala, Husain Hatim;Kheur, Mohit Gurunath;Apte, Sanjay Krishnaji;Kale, Bharat Bhanudas;Sethi, Tania Sanjeev;Kheur, Supriya Mohit
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.456-461
    • /
    • 2014
  • PURPOSE. Translucency and colour stability are two most important aspects for an aesthetic dental restoration. Glass ceramic restorations are popular amongst clinicians because of their superior aesthetic properties. In the last decade, zirconia has generated tremendous interest due to its favorable mechanical and biological properties. However, zirconia lacks the translucency that lithium disilicate materials possess and therefore has limitations in its use, especially in esthetically demanding situations. There has been a great thrust in research towards developing translucent zirconia materials for dental restorations. The objective of the study was to evaluate and compare the transmittance of a translucent variant of zirconia to lithium disilicate. MATERIALS AND METHODS. Two commercially available zirconia materials (conventional and high translucency) and 2 lithium disilicate materials (conventional and high translucency) with standardized dimensions were fabricated. Transmittance values were measured for all samples followed by a microstructural analysis using a finite element scanning electron microscope. One way analysis of variance combined with a Tukey-post hoc test was used to analyze the data obtained (P=.05). RESULTS. High translucency lithium disilicate showed highest transmittance of all materials studied, followed by conventional lithium disilicate, high translucency zirconia and conventional zirconia. The difference between all groups of materials was statistically significant. The transmittance of the different materials correlated to their microstructure analysis. CONCLUSION. Despite manufacturers' efforts to make zirconia significantly more translucent, the transmittance values of these materials still do not match conventional lithium disilicate. More research is required on zirconia towards making the material more translucent for its potential use as esthetic monolithic restoration.

수종 치과용 석고의 마모저항도 및 표면조도에 관한 비교 연구 (A STUDY ON THE ABRASION RESISTANCE AND SURFACE ROUGHNESS OF THE DENTAL STONES)

  • 심혜원;이양진;조리라;정경호;김경남
    • 대한치과보철학회지
    • /
    • 제40권2호
    • /
    • pp.184-192
    • /
    • 2002
  • The purpose of this study was to investigate the abrasion resistance and surface roughness of conventional dental stones and improved dental stones and newly developed dental stones. Materials included in this study were several dental stones and newly developed dental stone; 2 type III. 6 type IV (including newly developed dental stone). 1 type V Ten specimens for each material, total ninety specimens were made. Each specimen was subjected to 50 complete cycle abrasion under constant load 0.42N at speed or 6mm per sec. The depth after abrasion test was measured for each specimen. Surface roughness before and after abrasion test was compared. The results were as follows ; 1. The resin containing die materials such as Tuff Rock and Resin Rock had superior abrasion resistance. 2. Type IV, V dental stone exhibited greater abrasion resistance than Type III dental stone. 3. The results or the surface roughness showed similar pattern with the abrasion resistance.

실리콘 폴리머의 비닐그룹에 대한 가교제의 Si-H 비율이 폴리비닐실록산 치과용 인상재의 물성에 미치는 영향 (Effects of the Variation of Silyl Hydride-to-Vinyl Ratios in Dental Polyvinylsiloxane Impression Materials)

  • 주동현;정영화;송호준;최창남;박영준
    • Elastomers and Composites
    • /
    • 제44권2호
    • /
    • pp.150-155
    • /
    • 2009
  • 본 연구는 폴리비닐실록산 치과용 고무인상재의 조성에서 실리콘 프리폴리머 내 비닐그룹에 대한 가교제내 Si-H 그룹의 함량비 차이가 물성에 미치는 영향을 평가하였다. SiH/Vinyl 비가 1.6으로 가교제 함량이 낮은 $\underline{C6}$군(Cross-linker $\underline{6}$ parts 함유)은 인장강도가 실험군 중 가장 높았으나 경화속도가 너무 느렸고, SiH/Vinyl 비가 3.2인 C12군은 기계적 성질은 좋았으나 경화가 너무 빠르게 진행되어 조작이 용이하지 않은 단점을 보였다. 그러나 C14군은 가교제 함량이 더 낮은 실험군들에 비해 낮은 인장강도를 보였으며, C16군은 경화반응이 오히려 더 지연됨을 보여 과다한 가교제 첨가는 기계적 성질과 조작성에 불리한 영향을 미침을 알 수 있었다.

실리콘폴리머의 혼합사용이 폴리비닐실록산 치과용 인상재의 물성에 미치는 영향 (Effects of Silicone Polymer Blends on Physical Properties of Dental Polyvinylsiloxane Impression Materials)

  • 임창하;김민강;김영철;박남국;송호준;박영준
    • Elastomers and Composites
    • /
    • 제44권1호
    • /
    • pp.76-83
    • /
    • 2009
  • 본 연구는 비닐작용기의 위치가 다른 실리콘 프리폴리머와 수소작용기의 위치가 다른 가교제, 그리고 이들의 혼합사용이 제조된 치과용 폴리비닐실록산 고무인상재의 물성에 미치는 영향을 연구하였다. 한 종류의 중점도 프리폴리머를 사용한 실험군은 인장강도, 파단신율, 압축시 변형률이 다른 특성의 프리폴리머들을 혼합사용한 경우보다 낮은 값을 보였다. 측부와 말단에 수소작용기가 있는 CR210 가교제를 사용한 실험군은 측부에만 수소작용기가 있는 CR101 가교제를 사용한 실험군에 비해 압축시 변형률과 파단신율이 더 높았다. 측쇄에도 비닐기를 갖는 높은 비닐함량의 프리폴리머를 사용한 경우는 더 높은 인장강도를 보였지만, 경화 속도가 늦어서 임상 사용에 적합한 작업성을 갖는 치과용 인상재를 만들기 위해서는 이 성분이 경화시간에 미치는 영향과 이를 조절할 수 있는 방안에 대한 지속적인 연구가 필요하다고 생각한다.

치과용 모형재 색상에 따른 디지털 모형의 체적 안정성 연구 (The study on the dimensional stability of digitized dental stone replicas according to difference color of gypsum materials)

  • 최석순;김기백;이경탁;전진훈;김재홍
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.369-377
    • /
    • 2012
  • Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three-dimensional software. Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type IV stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non-contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}$=0.05). Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001. Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

AuCu-Zn합금의 시효경화거동 (Age-Hardening Behavior of AuCu-Zn Alloys)

  • 최석규;;김형일
    • 한국재료학회지
    • /
    • 제6권2호
    • /
    • pp.235-241
    • /
    • 1996
  • 등온자비 AuCu에 2.4, 4.3, 6.1at% Zn이 첨가된 합금의 시효경화거동과 상변태를 조사하였다. AuCu l형이 단독으로 존재하는 경우는 경도가 시효초기에 급격히 상승한 후 저하하였고, Zn 첨가량의 증가에 따라 규칙-불규칙 전이온도(Tc)가 약간 하강하였지만, AuCu l형+AuCu ll형의 공존영역의 온도는 훨씬 낮아졌다.

  • PDF