• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.027 seconds

Three-dimensional measurement of periodontal surface area for quantifying inflammatory burden

  • Park, Sa-Beom;An, So-Youn;Han, Won-Jeong;Park, Jong-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.3
    • /
    • pp.154-164
    • /
    • 2017
  • Purpose: Measurement of the root surface area (RSA) is important in periodontal treatment and for the evaluation of periodontal disease as a risk factor for systemic disease. The aim of this study was to measure the RSA at 6 mm below the cementoenamel junction (CEJ) using the Mimics software (Materialise, Leuven, Belgium). Methods: We obtained cone-beam computed tomography (CBCT) data from 33 patients who had visited the Department of Oral and Maxillofacial Radiology of Dankook University Dental Hospital. The patients comprised 17 men and 16 women aged from 20 to 35 years, with a mean age of 24.4 years. Only morphologically intact teeth were included in our data. Because the third molars of the maxilla and mandible have a high deformation rate and were absent in some participants, they were not included in our research material. Results: The CBCT data were reconstructed into 3-dimensional (3D) teeth models using the Mimics software, and the RSA at 6 mm below the CEJ was separated and measured using 3-Matic (Materialise). In total, 924 3D teeth models were created, and the area at 6 mm below the CEJ could be isolated in all the models. The area at 6 mm below the CEJ was measured in all teeth from the 33 patients and compared based on sex and position (maxilla vs. mandible). Conclusions: In this study, we demonstrated that it was feasible to generate 3D data and to evaluate RSA values using CBCT and the Mimics software. These results provide deeper insights into the relationship between periodontal inflammatory burden and systemic diseases.

An experimental study on hydrothermal degradation of cubic-containing translucent zirconia

  • Kengtanyakich, Santiphab;Peampring, Chaimongkon
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.265-272
    • /
    • 2020
  • PURPOSE. The aims of this study were to investigate mechanical properties and hydrothermal degradation behaviour of the cubic-containing translucent yttrium oxide stabilized tetragonal zirconia polycrystal (Y-TZP). MATERIALS AND METHODS. Four groups of Y-TZP (T, ST, XT, and P), containing different amount of cubic crystal, were examined. Specimens were aged by autoclaving at 122℃ under 2 bar pressure for 8 h. Phase transformation was analyzed using X-ray diffraction (XRD) to measure phase transformation (t→m). Kruskal-Wallis test was used to determine the difference. Surface hardness, biaxial flexural strength, and fracture toughness in values among the experimental groups and verified with Wilcoxon matched pairs test for hardness values and Mann Whitney U for flexural strength and fracture toughness. RESULTS. XRD analysis showed no monoclinic phase in XT and P after aging. Only Group T showed statistically significant decreases in hardness after aging. Hydrothermal aging showed a significant decrease in flexural strength and fracture toughness in group T and ST, while group XT and P showed no effect of aging on fractural strength and fracture toughness with P<.05. CONCLUSION. Hydrothermal aging caused reduction in mechanical properties such as surface hardness, biaxial flexural strength, and fracture toughness of Y-TZP zirconia. However, cubic-containing zirconia (more than 30% by volume of cubic crystal) was assumed to have high resistance to hydrothermal degradation. Clinical significance: Cubic-containing zirconia could withstand the intraoral aging condition. It could be suggested to use as a material for fabrication of esthetic dental restoration.

Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.

NaF-induced Autophagy on SCC25 Human Tongue Squamous Cell Carcinoma Cells

  • Kang, Jin-Mo;Lee, Bo-Young;Kim, In-Ryoung;Kim, Yong-Ho;Yu, Su-Bin;Park, Hae-Ryoun;Park, Bong-Soo
    • International Journal of Oral Biology
    • /
    • v.39 no.4
    • /
    • pp.193-199
    • /
    • 2014
  • Fluoride has been accepted as an important material for oral health and is widely used to prevent dental caries in dentistry. However, its safety is still questioned by some. Autophagy has been implicated in cancer cell survival and death, and may play an important role in oral cancer. This study was undertaken to examine whether sodium fluoride (NaF) modulates autophagy in SCC25 human tongue squamous cell carcinoma cells. NaF demonstrated anticancer activity via autophagic and apoptotic cell death. Autophagic vacuoles were detectable using observed to form by monodansylcadaverine (MDC) and acridine orange (AO). Analysis of NaF-treated SCC25 cells for the presence of biochemical markers revealed direct effects on the conversion of LC-3II, degradation of p62/SQSTM1, cleavage formation of ATG5 and Beclin-1, and caspase activation. NaF-induced cell death was suppressed by the autophagy inhibitor 3-methyladenine (3-MA). NaF-induced autophagy was confirmed as a pro-death signal in SCC25 cells. These results implicate NaF as a novel anticancer compound for oral cancer therapy.

Use of spherical coordinates to evaluate three-dimensional facial changes after orthognathic surgery

  • Yoon, Suk-Ja;Wang, Rui-Feng;Ryu, Sun-Youl;Hwang, Hyeon-Shik;Kang, Byung-Cheol;Lee, Jae-Seo;Palomo, Juan M.
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • Purpose: This study aimed to assess the three-dimensional (3D) facial changes after orthognathic surgery by evaluating the spherical coordinates of facial lines using 3D computed tomography (CT). Materials and Methods: A 19-year-old girl was diagnosed with class III malocclusion and facial asymmetry. Orthognathic surgery was performed after orthodontic treatment. Facial CT scans were taken before and after orthognathic surgery. The patient had a menton deviation of 12.72 mm before surgery and 0.83 mm after surgery. The spherical coordinates of four bilateral facial lines (ramal height, ramal lateral, ramal posterior and mandibular body) were estimated from CT scans before and after surgery on the deviated and opposite side. Results: The spherical coordinates of all facial lines changed after orthognathic surgery. Moreover, the bilateral differences of all facial lines changed after surgery, and no bilateral differences were zero. Conclusion: The spherical coordinate system was useful to compare differences between the presurgical and postsurgical changes to facial lines.

EFFECT OF GOLD ELECTRODEPOSIT OF PD-AG, NI-CR ALLOYS ON THE COLOR OF VENERRED RESIN (Pd-Ag 및 Ni-Cr 합금의 금 전착이 전장 레진의 색채에 미치는 영향)

  • Yang, Hong-So;Park, Yeong-Joon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.645-661
    • /
    • 1995
  • As the mechanical property of composite resin improved, composite resin has been widely used esthetic dentistry. In the field of esthetic dentistry, the color of prosthetic material is very important. The purpose of this study was to evaluate the color difference of specimens, by the types of alloys and gold electrodeposit. Experimental groups were as follows : Group Prec : Au-Pt alloy with no gold coating and no resin veneer. Group Semi : Pd-Ag alloy with no gold coating and no resin veneer. Group BAse : Ni-Cr alloy with no gold coating and no resin veneer. Group Gsem : Pd-Ag alloy with no gold coating and no resin veneer. Group Gbas : Ni-Cr alloy with no gold coating and no resin veneer. Group PreR : Resin veneer on the Pd-Ag alloy without gold coating. Group SemR : Resin veneer on the Pd-Ag alloy without gold coating. Group GbsR : Resin veneer on the Ni-Cr alloy with gold coating Group BasR : Resin veneer on the Ni-Cr alloy without gold coating. In this study, colors of metal surfaces and veneered resins were evaluated by the CIE $L^{*}a^{*}b$ system. The results obtained were as follows : 1. different alloy types and gold coating make the $L^{*}a^{*}b$ system. 2. The ${\Delta}E^*$ab value between groups semi and Base was less than 1.5 and there was no $a^*$ and $b^*$ value difference between groups Gsem and Gbas 3. The values of $L^*$ and $a^*$ ain groups GsemR and GbasR were so similar that the ${\Delta}E^*$ab value was as small as 0.58. 4. In resin specimens with gold coated semiprecious or base alloys showed yellower and redder deviation than the resin specimens with precious alloy. 5. The ${\Delta}E^*$ab values between goups PreR-GsemR and groups PreR-GbasR were as small as 2.68 and 2.22 respectively.

  • PDF

TME EFFECT OF MAGNETISM(NEODYMIUM MAGNET) ON BONE FORMATION AROUND TITANIUM IMPLANTS INSERTED INTO THE TIBIA OF RABBIT (Rabbit의 tibia에 매식된 titanium시편 내부에 설치한 희토류 자석의 자성이 주위의 골형성에 미치는 영향에 관한 연구)

  • Park Myung-Won;Lee Sung-Bok;Kwon Kung-Rock;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.519-527
    • /
    • 2005
  • Statement of problem : There are many articles that showed that the magnetism affected the bone formation around titanium implant. It means that a proper magnetism made the osseointegration improved around the implant. So after additional research on the other effect of magnetism on bone formation in implant therapy, we can conclude its possibility of clinical application on implant treatment. Purpose: The purposes of this study were to find out the intensity of magnetic field where magnetism in the titanium implant specimen inserted into the bone could affect the bone formation, and to discover the possibility of clinical application in the areas of dental implants and bone grafts. Material and method: Ten adult male rabbits(mean BW 2Kg) were used in this study. Titanium implant specimens were surgically implanted on the mesial side of the tibia of rabbits. Neodymium magnets(Magnedisc 500, Aichi Steel Corp. Japan) were placed into the implants of experimental group except control group, just after placement of the titanium implants. At 2, 4 and 8 weeks after the surgery, the animals were sacrificed, specimens were obtained and stained with Hematoxylin-Eosin for light microscopic evaluation and histomorphometric analysis. Conclusion : The results were as follows: 1. In radiographic findings, increased radiopacity downward from crestal bone was observed along the titanium implant specimen at experimental period passed by 2, 4, and 8 weeks in both control and experimental group. 2. In histoiogic findings, increased new bone formation was shown in both control and experimental group through the experiment performed for 2, 4, and 8 weeks. More new bone formation and bone remodeling were shown in experimental group. 3. In histomorphometric analysis, the bone contact ratios were 11.9% for control group and 38.5% for experimental group (p<0.05).

A COMPARATIVE ANALYSIS WITH RESONANCE FREQUENCY ACCORDING TO VARIOUS SIMULATED BONE DEFECTS (다양한 가상 골 결함에 따른 공진 주파수의 비교 분석)

  • Kim Sang-Mi;Park Chan-Jin;Yi Yang-Jin;Chang Beom-Seok;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.487-497
    • /
    • 2005
  • Purpose: Resonance frequency analysis (RFA) , a non-invasive technique for the clinical measurement of implant stability, was investigated. Peri-implant bony defect may contribute to implant failure. This in vitro study evaluated the resonance frequencies according to various bony defects and determined whether the directional bone defect can affect the value of frequency analysis. Material and Method: Fifteen 3.75 mm in diameter and 10 mm in length, machined self-tapping implant future were used. Twelve types of bone defects that have different horizontal and vertical dimensions were simulated. Embedded implants were attached to the dental surveyor. Then, the transducer was connected with the implant fixture and the ISQ value was measured at four different directions. Two-way analysis of variance and post hoc $Sch\`{e}ffe'$ test were performed at the 95% significance level. Results: The control group showed the highest ISQ value and 5 thread-$360^{\circ}$ group had the lowest one. As the vertical exposure of implants in each angle was increased, the ISQ value was decreased. Although the horizontal exposure in each thread was increased, the ISQ value was not significantly decreased. Conclusion : Although the simulated defect type was different from each other, the ISQ value was similar among groups.

CYTOTOXICITY OF RETROGRADE FILLING MATERIALS TESTED BY 51Cr RELEASE, MIT AND LD ACTIVITY (51Cr방출과 MTT 및 LD활성도를 이용한 역충전재의 세포독성에 관한 연구)

  • Choi, La-Young;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.409-428
    • /
    • 1994
  • Endodontic surgery is performed when conventional endodontic therapy fails or is contraindicated. In such cases, retrograde filling materials including amalgam, composite resin, and various cements have been used. Biocompatibilty and margin sealing ability of retrograde filling materials are important for the long term success of endodontic surgery. In vitro cell culture is frequently used as the method of measuring the biocompatibilty of dental materials. The purpose of this study was to evaluate the cytotoxicity of six kinds of retrograde filling materials including newly developed light curing glass ionomer cements. Each material was mixed according to. the manufacture's instruction and evaluated as : freshly mixed, 24-hour after mixing, and 168-hour after mixing respectively. The elution solution was extracted after 24-hour contact with materials using media. Cytotoxicity was evaluated by direct contact, or elution contact. Test results of radiochromium($^{51}Cr$) release, cell viability using tetrazolium dye (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl dimethyltetrazolium bromide(MTT) test and lactate dehydrogenase(LD) of damaged L929 cells were analyzed. In the $^{51}Cr$ release of direct contact, all experimental retrograde filling materials except amalgam and glass ionomer cement showed increased cytotoxicity compared to control. In the $^{51}Cr$ release of elution solution, the released $^{51}Cr$ was so minimal that it was impossible. to evlauate the cytotoxicity exactly. The elution solutions of glass ionomer cement and IRM showed marked cytotoxicity in MTT test. LD enzyme activity was highest in tests of direct contact with composite, light curing composite, and light curing glass ionomer cement and IRM. Amalgam revealed least cytotoxicity while IRM showed cytotoxicity using all three methods. Composite, light curing composite and light curing glass iomomer cement were cytotoxic in the tests of $^{51}Cr$ release and LD activity. Glass ionomer cement showed cytotoxic effect only in the MTT method. From these results it is suggested that the standardization and optimization of cytotoxicity testing, especially using elution solutions, should be strongly advised.

  • PDF

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).