• Title/Summary/Keyword: dental impression material

Search Result 97, Processing Time 0.022 seconds

The Property Change of Silicone Impression Materials with Change of Storage Temperature (실리콘 인상재의 보관온도에 따른 특성변화)

  • Oh, Sang-Hwan;Moon, Seung-Kyun;Kim, Kyoung-Nam
    • Journal of dental hygiene science
    • /
    • v.10 no.6
    • /
    • pp.459-464
    • /
    • 2010
  • The purpose of this study was to evaluate the physical properties of hydrophilic polyvinyl siloxane impression materials as change of material's storage temperatures. Working time, strain-in-compression, elastic recovery and consistency were tested according to ISO Standard NO. 1563. The results are as followed. 1. Working time decreased in cold storage. 2. Strain-in-compression was different in storage temperatures. Material's strain-in compression in cold temperatures were higher than in room temperature and in incubator. 3. A coefficient of elastic recovery varied by storage temperatures. The rate in cold temperature was the lowest and in incubator was the highest. 4. Consistency of impression substance different in storage temperatures. The extent in cold temperature is the highest and in incubator was the lowest. Statistical analysis(SPSS 14.0k, p>0.05) showed that storage temperature affect to material's physical properties. We recognized that the physical properties of polyvinyl siloxane impression materials were changed according to storage temperature.

Fundamental Study for Developing Silicone Rubber Impression Material (실리콘 고무인상재 개발을 위한 기초연구)

  • Oh, Young-Il;Han, Kyung-A;Kim, Kyung-Nam;Cho, Lee-Ra;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • v.35 no.1
    • /
    • pp.19-28
    • /
    • 2000
  • The fundamental study of additional silicone impression material has been performed by comparing the other import products. In order to estimate the possibility of usage of the impression material developed in this study, the several techniques such as IR, EDX, DSC, TGA, rubber rheometer, and contact angle measurement were used. According to the results, there were not any product satisfying all properties required in the impression material. The impression material developed in this study showed best mechanical properties among the all impression materials. However. the wetting property should be studied more by an introduction of a hydrophilic surfactant or modification of a base polymer.

  • PDF

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

A STUDY ON DIMENSIONAL STABILITY OF IMPRESSION MATERIALS FOLLOWING IMMERSION DISINFECTION (수종 인상재의 침지 소독이 경석고 모형의 크기 안정성에 미치는 영향에 관한 연구)

  • Song, Ki-Yong;Yang, Jae-Ho;Lee, Sun-Hyung;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.506-515
    • /
    • 1999
  • Dental practice can produce and spread some infectious diseases from patients to dentist, dental assistant, and dental labors. One possible method for preventing these cross-contamination is to immerse dental impression in chemical disinfectants. So for many investigators studied on the dimensional changes of dental impressions and on the surface qualities of stone casts made from impression following immersion in disinfectants. This study was proposed to evaluate some popular impression disinfectant combination from the point of dimensional stability. Impression was taken from dental arch-shaped metal model. Irreversible hydrocolloid and 3 elastomers(polyvinyl siloxane, polysulfide, polyether) were immersed in 3 disinfectants (2% glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite) for 10 minutes and measured both cross-arch and anterior-posterior distance under stereo microscope to evaluate dimensional change. The results obtained were as follows: 1. Dimensional changes of irreversible hydrocolloid impression was statistically different in cross-arch and anterior-posterior distance when immersed in 2% glutaraldehyde solution and in anterior-posterior distance when immersed in 0.5% sodium hypochlorite solution from control group (p<0.05). 2. Dimensional changes of polyvinyl siloxane and polysulfide impression were not statistically different from control group (p>0.05). 3. Dimensional changes of polyether impression was statistically different in cross-arch distance when immersed in 0.5% sodium hypochlorite solution and in anterior-posterior distance when immersed in 1% povidone-iodine solution from control group (p<0.05). 4. In all cases, dimensional changes were less than 0.1% from the original dimension and concluded clinically acceptable.

  • PDF

Effect of latex gloves on polymerization inhibition of addition silicone impression materials (라텍스 글러브가 시판되는 3종류 부가중합형 실리콘 인상재의 중합에 미치는 영향)

  • Kim, Soo-Hwa
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.3
    • /
    • pp.369-379
    • /
    • 2009
  • This study investigated the polymerization inhibition effect of latex gloves on addition silicone impression material. Three different kinds of addition silicone impression materials and a natural latex gloves were used in this study. The results were as follows. 1. Compared to the control group, all of those three kinds of impression materials took longer curing time in order of unwashed, alcohol and washed group, on the other hand, degloving group had shorter curing time than control group(p<0.05). 2. By the type of impression materials, there was no significant difference observed between Exafine and Twinz in ungloved group, Exafine and Imprint II in unwashed group, and Exafine and Twinz in degloving group(p>0.05). 3. The degree of polymerization at 6 minutes after mixing impression materials was evaluated by dividing its range into score 1 to 5. All of the impression materials got score 5 in control group and degloving group, which implies perfect polymerization. In unwashed group, most of them appeared to be score 2 while score 3 were most frequently observed in alcohol group and score 4 in washed group. Thus each group showed differences in the degree of polymerization(p<0.05).

  • PDF

Cytotoxicity Evaluation of Elastomeric Impression Materials Using Different Fibroblasts Cell Lines

  • Kwon, Jae-Sung;Kim, Kyoung-Nam
    • Journal of Korean Dental Science
    • /
    • v.7 no.2
    • /
    • pp.80-86
    • /
    • 2014
  • Purpose: Current common method of cytotoxicity evaluation for elastomeric impression materials use animal based cell lines, which the clinical relevance has been often questioned. Hence, the purpose of this study was to examine the difference in results with both human based and animal based fibroblast cell line. Materials and Methods: Three types of fibroblast cells were used in this study; conventional mouse fibroblasts of L929, human gingival fibroblasts (HGF-1), and immortalized human oral fibrobalsts (hTERT-hNOF). Test on extract and test by direct contact using different commercially available elastomeric impression materials were carried out according to the international standards. Result: There was significant difference in cell viability between types of fibroblasts cell used, where HGF-1 showed highest cell viability and L929 the lowest. Conclusion: Within the limitation of this study, careful consideration must be given when selecting the cells and interpreting the results for cytotoxicity evaluation of elastomeric impression materials, where use of human based cell lines such as hTERT-hNOF would be appropriate for both ease of cytotoxicity test and clinical relevance.

Comparison of the accuracy of digital models made from white light scanner by scanning method (스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지털 모형의 정확성 비교)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Jae-Hong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.6
    • /
    • pp.1082-1089
    • /
    • 2012
  • Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix$^{(R)}$, GC Industrial Corp, Japan) of master model were taken and type IV stone(aesthetic-base gold$^{(R)}$, Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.

Investigation of factors influenced on accuracy of polyvinylsiloxane (일부 시판 폴리비닐실록산 인상재의 정밀도에 영향을 미치는 요인분석)

  • Kim, Soo-Hwa;Lee, Sun-Mi;Hwang, Ji-Min
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.4
    • /
    • pp.89-99
    • /
    • 2008
  • In this study, polyvinylsiloxane impression materials were investigated to examine the characteristics of the impression materials that affect the accuracy of the final restoration. The flow property of impression materials which can reproduce the detail in the oral cavity and accurately duplicate it, and the tear strength and strain-in-compression which can cause problems when it is being removed from the oral cavity were studied. The results are as follows. 1. As for the flow properties of impression materials, Imprint II was 18.24${\pm}$0.30, which was the highest: and Twinz was 8.9${\pm}$0.62, which was the lowest. There was no significant difference among Imprint II, Examixfine, and Genie(p<0.05). 2. As for the tear strength of impression materials, Imprint II had the highest level, while Genie had the lowest value. There was no significant difference between Twinz and Genie(p<0.05). 3. As for the strain-in-compression, there were significant differences by impression material groups(p<0.05); the strain-in-compression of Examixfine was shown to be the highest at 5.56${\pm}$0.56, Twinz and Imprint II followed respectively, and Genie has the lowest at 3.19${\pm}$0.23. 4. Flow showed the correlation with tear strength but no significant connection to strain-in-compression. Also, there was no significant correlation between the tear strength and strain-in-compression (p<0.05). Making impression to reproduce oral tissue and tooth is an important part of making final restoration. The accuracy of impressions is influenced by the methods of taking impression or other condition. However the property itself of impression materials is the most essential and the materials with proper qualities should be selected.

  • PDF

EFFECT ON IMMERSI0N DISINFECTION OF HYDROPHIILIC RUBBER IMPRESSI0N MATERIAL ON DIMENSIONAL STABILITY AND SURFACE HARDNESS OF IMPROVED STONE CAST (친수성 고무인상재의 침적 소독이 경석모형의 크기의 안정성과 표면경도에 미치는 영향)

  • Nam, Mee-Hyun;Kang, Woo-Jin;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.569-583
    • /
    • 1995
  • Disinfection of dental impressions are necessary due to contamination with patient’s saliva and blood, which is a potential for cross-infection. The purpose of this study was to evaluate the effects of disinfection of four hydrophilic rubber impression materials with three disinfecting solutions, on the dimensional stability and surface hardness of improved stone casts. Three hydrophilic vinyl polysiloxane impression materials(Express, Reprosil, Exafine) and one polyether impression material(Impregum-F) were mixed according to the manufacturer’s directions and impressions were made on a ADA specification No. 19 stainless-steeldie. On removal of the impressions, each impression was immersed in one of the disinfectants(Banicide, Potadine, Clorox) for 10 minutes. After disinfection, type IV improved stone. casts were poured. On this cast, the linear dimension and surface hardness were measuredusing a Measurescope(Nikon, Japan) and a Barcol hardness tester(Barber, Colman Co U. S. A). The results were as follows : 1. The improved stone casts from disinfected Reprosil and Impregum-F impression material did not show dimensional changes(P>0.01). Those from disinfected Express and Exafine impression material showed dimensional changes(P<0.01). The amount of shrinkage was not clinically significant. 2. The improved stone casts from disinfected Express impression material did not exhibit changes in surface hardness(P>0.01), but those from disinfected Reprosil, Exafine, Imp regnum-F impression material showed changes in surface hardness(P<0.01). 3. The dimensinal stability and surface hardness of the improved stone casts were satisfactory using Banicide on Express, all disinfectants used in this study on Reprosil, Potadin and Clorox on Exafine, Banicide and Clorox on Impregum-F. According to these results, immersion disinfection of hydrophilic rubber impression mate rials did not adversely affect the resultant casts. Nevertheless compatibility tests of impression materials and disinfectants should be done when disinfecting impressions.

  • PDF

몇 치과인상재료의 Flow에 대한 실험적 연구 Flow Studies of Certain Dental Impression materials

  • Kim, In-Cheol;SeonU, Yang-Guk
    • The Journal of the Korean dental association
    • /
    • v.4 no.1
    • /
    • pp.5-7
    • /
    • 1963
  • The purpose of this investigation was to study the preperty of flow for seven different impression materials presently available in KOREA. In this study ,200 grams of a load was applied at regular intervals. As the result of this study, following points were revealed in terms of flow property of respective materials. 1)Impression plaster and irreversible hydrocolloid impression materials were found to have insufficient working time due to their tendency to set rapidly after mixing. 2)Regarding to impresssion pastes, it was found that it has manifested an ideal flow property until 2 minutes after mixing. Clinically, this material seems to allow sufficient working time for its manipulation.

  • PDF