• Title/Summary/Keyword: dental arch

Search Result 564, Processing Time 0.03 seconds

The Tooth Size RelaTionship Between Crowding Patients and Normal Subjects in Korean (총생치열을 갖는 교정환자와 정상인의 치아크기 비교)

  • Han, Man-Deuk;Jeon, Eun-Sook
    • Journal of dental hygiene science
    • /
    • v.6 no.1
    • /
    • pp.29-34
    • /
    • 2006
  • This study was undertaken to compare the tooth and arch size between crowding patient and normal subjects. Two group of dental casts were selected on the basis of crowding patients and normal subjects. One group, consisting of 40 pair of dental casts(20 male and 20 female), exhibited noncrowded dentitions. A second group, consisting of 40 pairs of dental cast(21 male and 21 female), exhibited remarkably crowding need for orthodontic treatment. Tooth width measurements were made with a sliding digital caliper with Vernier scale neared 0.01 mm. Mean, standard deviation, T-test of the following parameters were used to compare two group : individual mesiodistal crown widths, arch width and arch length. The following result were obtained. In the mesiodistal crown widths, normal subjects had generalized larger teeth than Wheeler's results(human tooth size index), except for maxillary central incisor, maxillary 2nd premolar, mandibular canine, and mandibular 1st molar. In the orthodontic patients with crowded dentitions, the mesiodistal tooth crown widths were generalized larger teeth than noncrowded normal subjects. In the arch width and arch length, the crowded dentition group had smaller arch width and arch length than the normal group.

  • PDF

THE STUDIES ON DENTAL ARCH GROWTH IN KOREAN CHILDREN (Arch Circumference) (한국인 아동의 치궁발육에 관한 고찰 (치궁주위경))

  • Sohn, Dong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.7 no.1
    • /
    • pp.13-16
    • /
    • 1980
  • The purpose of this study is to analyze the changes of arch circumferences during the deciduous dentition period. 600 stone models of maxillary and mandibular arches obtained from the children aged 3,4, or 5 years were under measurement. 1. Arch circumferences increase with age both in males and in females. 2. Arch circumferences of males are longer than females at the age of 4 and 5, but no notable differences at the age of 3. 3. Arch circumferences of upper arches are longer than those of lower arches.

  • PDF

변형된 설측호선 장치를 이용한 매복 대구치의 인위적 맹출

  • Park, Sang-Jin;Mun, Cheol-Hyeon
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.123-132
    • /
    • 2006
  • Patients who have impacted tooth are found commonly in orthodontic treatment. Although it is difficult to find the cause of impacted teeth, the most common, causes are prolonged retention of the deciduous teeth, trauma, aberrant sequence of eruption, lack of space and deficiency of Vitamin D. Impacted teeth may lead to esthetic and functional problems and root resorption of adjacent teeth, so we should treat it as soon as possible. Commonly used treatment method is the following: After surgically uncovering of the impacted teeth, a bond of orthodontic appliance is established, and orthodontic traction is started with a removable or fixed appliance. We used the modified lingual arch with a soldered auxiliary appliance in lingual arch for traction of lower impacted teeth. The modified lingual arch could control the magnitude and direction of the applied force with one-arch treatment, and also could give continuous force to impacted tooth without patient patient cooperation. We achieved good results with the modified lingual arch.

  • PDF

ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY (가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구)

  • Eom Sang-Ho;Oh Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization (광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.

MANAGEMENT OF CROWDED DENTITIONS IN YOUNG CHILDREN (어린이 총생의 조기치료)

  • Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.169-178
    • /
    • 2007
  • Dental crowding is one of the most common type of malocclusions in the mixed dentition. During the period of transition from the primary to the permanent dentition, minor incisor crowding is often present in the normally developing dentitions, but severe crowding can be caused by arch length/tooth size discrepancy. To determine the need for and appropriate timing of treatment for arch-length discrepancies, clinicians must be knowledgeable about normal development. This paper reviewed the literature on normal dental arch development and proper management of dental crowding according to its severity. Due to variations in the timing and the sequence of permanent tooth eruption, management of dental crowding should be specific to the individual patient.

  • PDF

Development of a new ball-type phantom for evaluation of the image layer of panoramic radiography

  • Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.255-259
    • /
    • 2018
  • Purpose: This study proposes a new ball-type phantom for evaluation of the image layer of panoramic radiography. Materials and Methods: The arch shape of an acrylic resin phantom was derived from average data on the lower dental arch in Korean adult males. Metal balls with a 2-mm diameter were placed along the center line of the phantom at a 4-mm mesiodistal interval. Additional metal balls were placed along the 22 arch-shaped lines that ran parallel to the center line at 2-mm buccolingual intervals. The height of each ball in the horizontal plane was spaced by 2.5 mm, and consequently, the balls appeared oblique when viewed from the side. The resulting phantom was named the Panorama phantom. The distortion rate of the balls in the acquired image was measured by automatically calculating the difference between the vertical and horizontal length using $MATLAB^{(R)}$. Image layer boundaries were obtained by applying various distortion rate thresholds. Results: Most areas containing metal balls (91.5%) were included in the image layer with a 50% distortion rate threshold. When a 5% distortion rate threshold was applied, the image layer was formed with a small buccolingual width along the arch-shaped center line. However, it was medially located in the temporomandibular joint region. Conclusion: The Panorama phantom could be used to evaluate the image layer of panoramic radiography, including all mesiodistal areas with large buccolingual width.

Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial

  • Aydin, Burcu;Senisik, Neslihan Ebru;Koskan, Ozgur
    • The korean journal of orthodontics
    • /
    • v.48 no.3
    • /
    • pp.153-162
    • /
    • 2018
  • Objective: The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. Methods: The initial alignment phase of fixed orthodontic treatment with NiTi or CuNiTi round archwires was studied in a randomly allocated sample of 66 patients. The NiTi group comprised 26 women, 10 men, and the CuNiTi ($27^{\circ}C$) group comprised 20 women, 10 men. The eligibility criteria were as follows: anterior mandibular crowding of minimum 6 mm according to Little's Irregularity Index (LII), treatment requiring no extraction of premolars, 12 to 18 years of age, permanent dentition, skeletal and dental Class I malocclusion. The main outcome measure was the alignment of the mandibular anterior dentition; the secondary outcome measure was the change in mandibular dental arch dimensions during 12 weeks. Simple randomization (allocation ratio 1:1) was used in this single-blind study. LII and mandibular arch dimensions were measured on three-dimensional digital dental models at 2-week intervals. Results: No statistically significant difference was observed between NiTi and CuNiTi according to LII (p > 0.05). Intercanine and intermolar arch perimeters increased in the CuNiTi group (p < 0.001). Inter-first premolar width showed a statistically significant interaction in week ${\times}$ diameter ${\times}$ application (p < 0.05). Conclusions: The effects of NiTi and CuNiTi round archwires were similar in terms of their alignment efficiency. However, the intercanine and intermolar arch perimeters, and the inter-first premolar width changes differed between groups.

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.