• Title/Summary/Keyword: dental acrylic resin

Search Result 183, Processing Time 0.032 seconds

BILATERAL BONY ANKYLOSIS OF THE TEMPOROMANDIBULAR JOINT (양측성 악관절 골성강직의 외과적 처치의 치험예)

  • Seo, Jin-Gwan;Lee, Yong-O;Im, Gil-Ung;Kim, Seon-Yong;Byeon, Sang-Gil;Park, Jeong-Dong
    • The Journal of the Korean dental association
    • /
    • v.14 no.3
    • /
    • pp.239-243
    • /
    • 1976
  • Bilateral true bony ankylosis of temporomandibular joint is extremely rare. Treatment in all cases should be surgical. Considerable difficulty has been encountered by surgeons in the judgment of the planning of the treatment for ankylosis : either by gap arthroplasty treatment because of no recurrence and the excelent results obtained. I performed an osteoarthrotomy and interposition arthroplasty bilaterally, using combined materials consisting of acrylic resin and gold plate. My experience with alloplasty in ankylosed temporomandibular joints is pressented.

  • PDF

Comparative accuracy of implant impression techniques with different splinting materials (임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교)

  • Ki-Yoon Hong;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • Purpose: We investigated the effect of open tray impression using pick-up impression coping and close tray impression using transfer impression coping on the accuracy of impression in edentulous patients on their mandibular parts. the effect of material types of pick-up type impression copings for splinting in open tray impression on the accuracy of impression was also evaluated. Materials and Methods: Two implant fixtures were implanted in parallel in the left molar of the mandibular in the shape of a mandibular partial edentulous model. The 40 individual trays were fabricated using 3D printer. The prepared individual trays were classified into 4 groups (i.e., PN, PG, PH, and TN groups), and a total of 40 impression-takings were conducted. A master cast was connected to a Scan Body. The converted STL file was super-imposed on the scan images of the various groups. Results: The order of standard deviation values decreased as follows: PN (0.2343 ± 0.0844 mm), TN (0.2192 ± 0.0840 mm), indicating that the high accuracy of impression for TN group. In addition, for the comparison results between the material types used in splinting the open tray impression, the PH group showed a relatively lower standard deviation (0.1910 ± 0.1176 mm) than that of the PN group (0.2343 ± 0.0844 mm), PG group (0.2556 ± 0.1082 mm). Conclusion: The acrylic resin synthesized by light-induced polymerization exhibited a higher accuracy of impression taking than that of autopolymerizing acrylic resin. Meanwhile, the accuracy of impression taking was not dependent on the implant impression taking method or the presence of connection/fixation of impression copings.

COMPARISON ON TENSILE BOND STRENGTH OF PERMANENT SOFT DENTURE LINERS BONDED TO THE DENTURE BASE RESIN (수종의 영구 탄성 이장재와 의치상용 레진간의 인장 결합 강도)

  • Kim, Lae-Gyu;Chung, Moon-Kyu;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.200-211
    • /
    • 1999
  • For many years permanent soft denture liners has been widely used in dental practice directly or indirectly because of its function in absorbing and distributing the impact force. However, it reveals problems such as lack of permanency and decreased bond strength in long term use. The purpose of this study is to measure the bond strength and failure between denture base resin and several permanent liners. Lucitone 199 was used as denture base resin with soft acrylic liners (Triad, Tokuso Rebase) and silicone elastomers (Tokuyama, Ufi Gel C) bonded to measure the tensile strength before and after thermocycling. The thermocycling was done in 2000 cycles at $5^{\circ}C,\;26^{\circ}C\;and\;55^{\circ}C$ and the measured tensile strength values before and after thermocycling were compared. The mode of failure was investigated in the separated specimens. The results are as follows. 1. As to tensile strength, the strongest material is Tokuso Rebase followed by Triad, Tokuyama, Ufi Gel C in before thermocycling and the order of Triad, Tokuso Rebase, Tokuyama, Ufi Gel C in after thermocycling state. There was significant difference between the values of Triad, Tokuso Rebase and Tokuyama, Ufi Gel C(p<0.05). 2. As to degree of displacement, Ufi Gel C showed most displacement with or without thermo-cycling treatment and also the difference was significant with the other materials(p<0.05). 3. As to comparisons before and after thermocycling, Tokuso Rebase and Tokuyama showed significant difference in bond strength, whereas Triad and Tokuso Rebase showed significant difference in the degree of displacement(p<0.05). 4. In debonded specimens, Triad and Ufi Gel C showed adhesion failure and Tokuyama showed cohesion failure. Both failures were observed in Tokuso Rebase with adhesion failure up to 70%. The results of this study showed that degree of bond strength between permanent soft denture liner and denture base resin were variable. There was a significant difference between soft acrylics and silicone elastomers with regard to bond strength. Further research in improving bond strength of widely used silicone elastomers and in developing the method of measuring bond strength between denture base resin and the lining materials is needed.

  • PDF

The effect of bonded resin surface area on the detachment force of lingual bonded fixed retainers: An in vitro study

  • Lee, Il-Hong;Lee, Jung-Hwan;Park, In-Young;Kim, Ji-Hyun;Ahn, Jang-Hoon
    • The korean journal of orthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • Objective: The aims of this study were to evaluate the relationship between the detachment force and bonding resin surface are and to determine the resin bonding surface area that would provide adequate bonding strength with minimum resin volume. Methods: One hundred and sixty human premolars were randomly divided into 4 groups of 40 teeth each. The diameter of the resin surface area in each group was as follows: group 1, 1.5 mm; group 2, 2.5 mm; group 3, 3.5 mm; and group 4, 4.5 mm. Respond Dead Soft straight (length 0.0175 inch) was used to fabricate the retainers, and $Transbond^{TM}$ XT was used to fix the retainers to the tooth surfaces. A pair of teeth was embedded in acrylic blocks for each specimen. Thus, each group comprised 20 samples. Fixed retainers were bonded to the teeth, and vertical force was applied at the middle of wire. The force was measured using a universal testing machine. Results: The mean value of detachment force was the highest for group 4 ($102.38{\pm}2.92N$), followed by group 3 ($63.54{\pm}2.21N$), group 2 ($51.95{\pm}1.61N$), and group 1 ($24.14{\pm}1.38N$). Conclusions: The detachment force of lingual fixed retainers was significantly affected as the area of the resin bonding surface increased. Considering the minimum bonding strength of brackets, a resin bonding surface area with a diameter of 3.5 mm would provide adequate bonding strength.

Resin bonding of metal brackets to glazed zirconia with a porcelain primer

  • Lee, Jung-Hwan;Lee, Milim;Kim, Kyoung-Nam;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.299-307
    • /
    • 2015
  • Objective: The aims of this study were to compare the shear bond strength between orthodontic metal brackets and glazed zirconia using different types of primer before applying resin cement and to determine which primer was more effective. Methods: Zirconia blocks were milled and embedded in acrylic resin and randomly assigned to one of four groups: nonglazed zirconia with sandblasting and zirconia primer (NZ); glazed zirconia with sandblasting, etching, and zirconia primer (GZ); glazed zirconia with sandblasting, etching, and porcelain primer (GP); and glazed zirconia with sandblasting, etching, zirconia primer, and porcelain primer (GZP). A stainless steel metal bracket was bonded to each target surface with resin cement, and all specimens underwent thermal cycling. The shear bond strength of the specimens was measured by a universal testing machine. A scanning electron microscope, three-dimensional optical surface-profiler, and stereoscopic microscope were used to image the zirconia surfaces. The data were analyzed with one-way analyses of variance and the Fisher exact test. Results: Group GZ showed significantly lower shear bond strength than did the other groups. No statistically significant differences were found among groups NZ, GP, and GZP. All specimens in group GZ showed adhesive failure between the zirconia and resin cement. In groups NZ and GP, bonding failed at the interface between the resin cement and bracket base or showed complex adhesive and cohesive failure. Conclusions: Porcelain primer is the more appropriate choice for bonding a metal bracket to the surface of a full-contour glazed zirconia crown with resin cement.

Clinical application of neutral zone and stereographic record in complete denture (Neutral Zone 개념과 Stereographic Record를 이용한 총의치 제작)

  • Lee, Joung-Min;Yi, Yang-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.2
    • /
    • pp.113-123
    • /
    • 2001
  • The success of complete denture prosthesis is to satisfy three basic requirements for the edentulous patient : maximum comfort, efficiency, and esthetic appearance. This can be achieved only if the dentures are both stable and retentive. When the residual alveolar ridge has resorbed significantly, stability and retention are more dependent on the correct position of the teeth and external surfaces of the denture. The stability and retention of the denture can be improved by locating the denture in the neutral zone and reproducing exact mandibular border movement for balanced occlusion. The neutral zone philosophy is based upon the concept that there exists a specific area where the musculature function will not unseat the denture in the mouth. In here, forces generated by the tongue are neutralized by the forces generated by the lips and cheeks. One of the simplest methods for recording border movements in three dimensions is to make stereographic record of condylar movement. Stereographs are made in the mouth during mandibular movement with intraoral clutches and central bearing point, and used in dictating the condylar movement on the articulator later by generating the condylar paths in doughy acrylic resin. Its procedure is simpler and more convenient than that of Pantograph. In this clinical report, we introduce the concept of neutral zone and stereograph in complete denture fabrication.

  • PDF

Metal artifact production and reduction in CBCT with different numbers of basis images

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Groppo, Francisco Carlos;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.41-44
    • /
    • 2018
  • Purpose: To evaluate the effect of different numbers of basis images and the use of metal artifact reduction (MAR) on the production and reduction of artifacts in cone-beam computed tomography images. Materials and Methods: An acrylic resin phantom with a metal alloy sample was scanned, with 450 or 720 basis images and with or without MAR. Standard deviation values for the test areas (around the metal object) were obtained as a way of measuring artifact production. Two-way analysis of variance was used with a 5% significance level. Results: There was no significant difference in artifact production among the images obtained with different numbers of basis images without MAR (P=.985). MAR significantly reduced artifact production in the test areas only in the protocol using 720 basis images (P=.017). The protocol using 450 basis images with MAR showed no significant difference in artifact production when compared to the protocol using 720 basis images with MAR (P=.579). Conclusion: Protocols with a smaller number of basis images and with MAR activated are preferable for minimizing artifact production in tomographic images without exposing the patient to a greater radiation dose.

Reactive oxygen species-mediated cytotoxicity of indirect restorative cement on periodontal stem cells (간접수용복 시멘트 처리로 유발된 활성산소종에 의한 치주줄기세포 독성)

  • Park, So-Yeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.5
    • /
    • pp.545-553
    • /
    • 2021
  • Objectives: This study aimed to investigate the cytotoxicity of Nexus RMGIC, an indirect restorative cement, on cell survival rate and reactive oxygen species (ROS) production in periodontal stem cells (PDSCs). Methods: PDSCs were incubated with serially diluted Nexus RMGIC eluates with and without the addition of N-acetyl-cysteine (NAC). Cell survival was determined using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. The ROS generation was determined by measuring the fluorescence intensity for 2',7'-dichlorofluorescin diacetate. Results: Nexus RMGIC exposure decreased cell proliferation and cell survival rate in a dose-dependent manner (1:8, 1:4, 1:2, 1:1) in PDSCs. The cytotoxicity of Nexus RMGIC was inhibited by treatment with 10-mM NAC. In addition, the production of ROS was detected by immunofluorescence after PDSCs were exposed to Nexus RMGIC. However, ROS generation was significantly suppressed in the NAC pretreatment compared with the Nexus RMGIC group. Conclusions: Nexus RMGIC increased the cytotoxicity and ROS generation. ROS was involved in Nexus RMGIC-induced cell toxicity.

The Effect of Water Immersion on the Surface Strength and the Flexural Strength of the Acrylic Resin for Occlusal Appliances (교합장치용 아크릴레진의 표면경도와 굴곡강도에 대한 침수의 영향)

  • Lee, Hoy-Youn;Im, Yeong-Gwan;Kim, Byung-Gook;Lim, Hoi-Soon;Kim, Jae-Hyung
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.1
    • /
    • pp.75-81
    • /
    • 2010
  • By repeating nocturnal bruxism occlusal appliance's wearing condition that is used to cure temporomandibular disorders into the vitro experiment, research aims to find out how moisture infiltrated and drying cycle process affects on the surface microhardness of the resin for occlusal appliance and flexural strength. By utilizing resin for occlusal appliance which is the main component of poly methyl methacrylate, bar shaped sample was produced. For the resin sample utilized as the controlled group 1, the sample was infiltrated in the moisture for 7 days in the temperature of 37C. Then, the resin sample of the controlled group 2 was maintained in a dry condition for 7 days in the normal temperature. After that, each sample's surface microhardness and flexural strength were measured. For the resin sample that is utilized as the experimental sample, the sample was infiltrated in the moisture for 7 days in the temperature of 37C. Then, it was inundated for 8 hours a day and dried in the normal temperature for 16 hours with the continuous process of moisture infiltration and dry cycle process for 30 days. During this cycle process, sample's surface and flexural strength were measured in the 1st day, 7th day, and 30th day. Then, it was statistically analyzed to find out the difference of controlled and experiment group's surface microhardness and flexural strength. Results are 1. For the experimental and controlled group's surface microhardness of the resin for the occlusal appliance, it did not show any significant differences after moisture infiltration and dry cycle process repetition. 2. In case of the flexural strength for resin for the occlusal appliance, experimental group with moisture infiltration and dry cycle for 30 day process had greater effect than the experimental group at the 1st day and controlled group These results can be considered to be utilized from the patients of the temporomandibular disorders towards occlusal appliance used and maintained method.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF