• Title/Summary/Keyword: dental Lab.

Search Result 303, Processing Time 0.019 seconds

Comparison of internal porosity of dental titanium castings with different casting machines (주조방식에 따른 티타늄 주조체의 내부결함 비교)

  • Lee, Kyung-Eun;Kim, Bu-Sob;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.129-140
    • /
    • 2007
  • The purpose of this study was to evaluate the titanium castability (internal porosity) between pressure type casting machine & centrifugal casting machine with air-vent or not. Internal porosity is a well-known problem in dental titanium casting, resulting in inferior mechanical properties of dental restorations. To evaluate the castability, the square plate was chosen. 40 plate patterns($20{\times}20{\times}1.8mm$)were attached to funnel-shaped sprue. Then 20 plate patterns were attached air-vent. They were invested in titanium investment material and cast in a pressure type casting machine(20castings) and centrifugal casting machine(20castings). Each group were divided with air-vent(10castings) or not(10castings). The titanium castings were evaluated by radiographic photograph for the location of the internal porosities. The percentage porosity of each specimen was determined using standardized digital radiographs. The results were analyzed with analysis of variance and t-test for paired comparison between two groups.

  • PDF

A Study on SEM Observations of Low Temperature Degradation in Zirconia Dental Ceramics (저온열화에 따른 치과용 지르코니아의 전자현미경 관찰 연구)

  • Lee, Jung-Hwan;Joo, Kyu-Ji;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.15-23
    • /
    • 2011
  • Purpose: Thy yttria tetragonal zirconia polycrystalline(Y-TZP) is a good structural ceramic for dental restoration. But it have a problem that delamination of veneering ceramic from the Y-TZP core materials. The problem generally occur at the interface, thus this study was conducted to evaluate the interface of Y-TZP using scanning electron microscopy(SEM). Methods: To investigate this aspect, high-resolution SEM observations were made of polished and etched (HF content gel) cross-sections of the interface area. Dry and moist veneering porcelain powders were built up on the zirconia base. Results: The extent of this surface faceting is dependent upon the moisture content of the porcelain powder and the firing temperature. More moisture and higher final heating temperature accelerates the observed faceting of the Y-TZP grains at the interface to the veneering ceramic. Conclusion: These changes of the Y-TZP grains indicate that destabilization of the tetragonal phase of zirconia occurs at the interface during veneering with ceramic. It may result in a reduction of the stability of the zirconia and interface.

Comparative study of color reproducibility of zirconia using a dipping method and coating method (도포법 및 침전법을 이용한 지르코니아의 색조 재현성 비교 연구)

  • Lee, Hee-Jung;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of Technologic Dentistry
    • /
    • v.35 no.3
    • /
    • pp.185-192
    • /
    • 2013
  • Purpose: The aim of this study was to compare with color reproducibility of the coating method and dipping method using a colour liquid. Methods: Two groups of square-shaped specimens ($10mm{\times}10mm$ in diameter, 1.5mm thickness) were prepared for analysis(n=15/group). The CM(Coating Method) group was fabricated as full zirconia specimens with the coating coloring method and Group DM(Dipping Method) was prepared as specimens of 0.7 mm-thick zirconia plate using the dipping coloring method and veneered with 0.8mm-thick porcelain. Color parameters were measured with ShadeEye $NCC^{(R)}$ spectrophotometer and color differences were calculated using the equation ${\Delta}E^*= \{({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2\}^{1/2}$. Non-parametric statistical methods, the Mann-Whitney test, and the Kruskal-Wallis test were used to analyze the data. Type one error rate was set at 0.05. Results: Color difference values larger than 7 were observed between specimens with the coating method and the dipping method, which were detectable difference in a clinical setting. Conclusion: Cautious application of the coating coloring method in a clinical setting and further researches to standardize the coating method are needed.

The Study on the improvement of dental technician practical examination I (치과기공사 실기시험 개선에 관한 조사 연구 I)

  • Bae, Eun-Jeong;Kim, Woong-Chul;Chung, In-Sung;Nam, Sang-Yong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.413-421
    • /
    • 2012
  • Purpose: The purpose of this study is to investigate the improvement measure of dental technician practical examination. Methods: A survey was performed on 111 dental technicians who were self-written questionnaire. The results were analyzed by SPSS 12.0. The collected data was analyzed by frequency and chi-square test. Results: Questions most necessary work tools with the articulator was the highest with 55.9%, Electric wax carver(16.2%), heating clear(14.4%), CAD/CAM program(9.0%) was in the order. The need for additional practical test in response to actions included maxillary and mandibular comments occlusal work that you have to wax up the highest rate of 63.8%. Items most in need of improvement was strengthen of clinically oriented(48.0%), separation of written and practical(14.6%), control the degree of difficulty(11.4%) were the next order. Conclusion: Based on the results of this study, the current dental technician did not show major problems in the practical test. However, clinicians should be strengthened mainly. To do this, the use of the articulator is essential.

Research recognition and image about dental technician (치과기공사에 대한 인식정도와 이미지 조사 - 대구지역을 중심으로 -)

  • Jung, Hyo-Kyung;Kim, Jeong-Sook;Lee, Seung-Hee
    • Journal of Technologic Dentistry
    • /
    • v.32 no.2
    • /
    • pp.91-102
    • /
    • 2010
  • Purpose : The purpose of study was 500 people who are not related to dentistry in order to survey image about dental technicians. Methods : The subjects were composed of 500 people who are not related in Daegu Metropolitan city. This study was done using the Statistical Package for Social Sciences 17.0 for Windows. As for the analysis methods, the study used the frequency analysis, percentage, mean, t-test, analysis of variance. Results : The score on the image of dental technicians declined in the order of occupational image(2.98), work image(3.14), personal image(3.26), social image(2.87). 'It is hard and stressful' in the occupational image had the highest score with 3.69, 'Dentist and companionship are strong' in the occupational image had the lowest score with 2.21. 'It need expert knowledge and a skilled technology' in the work image had the highest score with 3.69, 'Health medical treatment side of health technique is occupation.' in the work image had the lowest score with 3.69. 'It always work busily' in the personal image had the highest score with 3.69, 'It is value and is effect work.' in the personal image had the lowest score with 3.69. 'An employment is easy after license acquisition.' in the social image had the highest score with 3.69, 'It admit independence' in the social image had the lowest score with 3.69. Conclusion : Dental technition research in order to image improvement and recognition, as the medical professional must construct the desirable dental technition image and recognition.

A study on Common Errors in Digital Impressions: (An Example of CEREC$^{(R)}$ AC) (디지털 인상 채득 시 흔히 발생하는 오류에 관한 연구 - CEREC$^{(R)}$ AC의 사례 중심으로 -)

  • Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: The purpose of the study was a quantitative evaluation of common errors in digital impression procedure using CEREC$^{(R)}$ AC system. Methods: Two-hundreds digital impression data comprising 174 inlays, 26 onlays by CEREC$^{(R)}$ AC in-office CAD/CAM system were obtained from a dental clinic. One evaluator assessed errors of the digital impression data and divided into five categories of errors: inappropriate scanner positioning (ISP), improper handling with a scanner (IHS), irregular powder arrangement (IPA), improper cavity preparation (ICP), and insufficient scanned data (ISD). Results: The most common errors were IPA(21%), and ISP and ISD were followed by 17% respectively. IHS was found in 14.5% of all digital impression data. ICP comprising only 6.5% was the rarest. Conclusion: Most errors were due to inaccurate manipulation with an intraoral scanner or improper cavity preparation for scanning. A deliberate manipulation to prevent common errors mentioned may deliver an optimal result in the digital impression procedure.

Microstructures and Mechanical Properties of Beryllium(Be)-free Ni-Cr-Mo based Alloys for Metal-Ceramic Crown (베릴륨(Be)이 미 첨가된 치과도재소부용 Ni-Cr-Mo계 합금의 미세조직 및 기계적 성질 특성)

  • Song, Kyung-Woo;Go, Eun-Kyoung;Lee, Jung-Hwan;Jung, Jong-Hyun;Noh, Hak;Han, Jae-Ick
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.321-329
    • /
    • 2006
  • The popularity of Ni-Cr-Mo based metal alloys for metal-ceramic crown have increased recently because of low price, superior yield strength and rigidity. the use of these alloys give them the potential advantage of thinner copping with the required rigidity for long span bridges. The purpose of this study was to assess the microstructures and mechanical properties of Ni-Cr-Mo-(Si,Al,Nb,Zr,Ti.Cu,Mm) based Alloys not containing beryllium(Be) related toxic effects. The abtained results indicated that as-cast these specimen alloys showed compositional and microstructural differences, and mechanical properties values of Ni69Cr20Mo5Si2Al4 alloy among these specimen alloys was found to be superior to those of commercial Ni-Cr based alloy using in market place today.

  • PDF

Influential factors for recognition and use of oral care supplies by oral prophylaxis practice lab visitors (치면세마실습실 방문자의 구강관리용품 인지 및 사용에 영향을 미치는 요인)

  • Park, In-Suk;Jeong, Eun-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.133-144
    • /
    • 2017
  • Objectives: The purpose of this study was to examine the oral health care of oral prophylaxis practice lab visitors, their recognition of oral care supplies, their use of oral care supplies by type, and influential factors for their recognition and use of oral care supplies. Methods: The subjects in this study were 275 people who visited an oral prophylaxis practice lab at a university located in an urban community. The visitors were respectively interviewed from March to June, 2016, and the data from 260 respondents who properly responded were analyzed, and data from 15 visitors who provided incomplete responsees were excluded. Statistical analysis was performed using the nonparametric tests, mann-whitney test and kruskal-wallis test, and multiple regression analysis using SPSS. Results: The mean score of oral care products was 2.25, the average degree of use was 0.09, and dental floss (0.29) was the most used oral care product. There was a significant difference between the groups according to gender (p<0.001), age (p<0.001) and marital status (p<0.001). Factors influencing the perception of oral care products were experience in brushing education and experience in oral care products education. Conclusions: The recognition of the oral prophylaxis practice lab visitors about oral care supplies and their use of the supplies were under the influence of oral health education. Therefore, sustained efforts should be directed into the development of efficient oral health care education programs that can inform people about the importance of oral health care, publicize oral care supplies, and encourage the use of these supplies.

A study on the dental technology and fabrication cost analysis of implant prosthesis for National Health Insurance (건강보험 급여화 관련 임플란트보철물의 기공원가 분석 연구)

  • Cho, Mi-Hyang;Lee, Gwang-Young;Lee, Hee-kyung;Nam, Shin-Eun;Ryu, Jae-Kyung;Kwon, Hyok-Mun;Kim, Kyung-Rok;Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.149-162
    • /
    • 2020
  • Purpose: The purpose of this study was to conduct a cost accounting of implant prosthesis according to the fabrication activities. Methods: In this study, the cost price of implant prosthesis fabrication activities was calculated by the bottom-up costing approach for material and labor cost and the top-down costing approach for expenses and other. Results: The total cost price was estimated to 220,000 ~ 310,000 won per one implant prosthesis. By product, the screw type was estimated to 220,000 ~ 230,000 won, and when the stent and tray were included, it was 260,000 ~ 270,000 won, which increased about 40,000 won. And, the cement type with more material and labor time was estimated to 250,000 ~ 260,000 won, and when the stent and tray were included, it was about 300,000 won. Conclusion: In terms of the fabrication cost ratio by items, it was shown that material cost and labor cost accounted for about 40% and 30% of the total cost structure for resin case, respectively, which was the opposite for porcelain. It was shown that expenses and general administrative expenses accounted for about 15%, and profits were about 11% ~ 14% in both cases.

Development of Dental Image Management System based on Mobile Computing (모바일환경에서의 치과환자 구강영상 관리체계 개발)

  • Oh, Seon-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.1
    • /
    • pp.379-385
    • /
    • 2012
  • The purpose of this study is to propose that co-working plan with patient information service system for dental clinic and dental lab using smart phone system which is recently spread to. For this purpose, we introduced latest mobile S/W development environment. And design key features of patient information service system based on mobile platform(Android) by user interface design. In fact, we have applied this system(mobile system) to dental clinic and dental lab, we have following results: 1.There were significant possibility in dental utilization of smart phone based on latest ICT(Information & Communication Technology) technology. 2. Improve conventional method of image upload by connecting digital camera to the server computer using USB port. 3. Reduce error of image management by direct upload to server computer from smart phone. 4. Improve process of making prosthetic appliance by displaying dental image on smart phone in dental lab.