Comparative study of color reproducibility of zirconia using a dipping method and coating method

도포법 및 침전법을 이용한 지르코니아의 색조 재현성 비교 연구

  • Lee, Hee-Jung (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Kim, Jae-Hong (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Kim, Woong-Chul (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Kim, Ji-Hwan (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University) ;
  • Kim, Hae-Young (Department of Health Science Specialized in Dental Lab. Science & Engineering, Graduate School, Korea University)
  • 이희정 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김재홍 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김웅철 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김지환 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김혜영 (고려대학교 대학원 보건과학과 치의기공전공)
  • Received : 2013.07.24
  • Accepted : 2013.09.13
  • Published : 2013.09.30

Abstract

Purpose: The aim of this study was to compare with color reproducibility of the coating method and dipping method using a colour liquid. Methods: Two groups of square-shaped specimens ($10mm{\times}10mm$ in diameter, 1.5mm thickness) were prepared for analysis(n=15/group). The CM(Coating Method) group was fabricated as full zirconia specimens with the coating coloring method and Group DM(Dipping Method) was prepared as specimens of 0.7 mm-thick zirconia plate using the dipping coloring method and veneered with 0.8mm-thick porcelain. Color parameters were measured with ShadeEye $NCC^{(R)}$ spectrophotometer and color differences were calculated using the equation ${\Delta}E^*= \{({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2\}^{1/2}$. Non-parametric statistical methods, the Mann-Whitney test, and the Kruskal-Wallis test were used to analyze the data. Type one error rate was set at 0.05. Results: Color difference values larger than 7 were observed between specimens with the coating method and the dipping method, which were detectable difference in a clinical setting. Conclusion: Cautious application of the coating coloring method in a clinical setting and further researches to standardize the coating method are needed.

Keywords

References

  1. Baek KH, Woo YH, Kwon KR, Kim HS: Spectrophotometric analysis of the influence to shade of zirconia core on the color of ceramic. The Journal of the Korean academy of prosthodontic society, 46(4), 409-419, 2008
  2. Belles DM, Cronin RJ, Duke ES. Effect of metal design and technique on the marginal characteristics of the collarless metal ceramic restoration. The Journal of Prosthetic Dentistry, 65(5), 611-619, 1991. https://doi.org/10.1016/0022-3913(91)90193-Z
  3. Beuer F, Stimmelmayr M, Gueth JF, Edelhoff D, Naumann M. In vitro performance of fullcontour zirconia single crowns. Dental Materials, 28(4), 449-456, 2012. https://doi.org/10.1016/j.dental.2011.11.024
  4. Bindl A, Mormann WH. Clinical and SEM evaluation of all-ceramic chair-side CAD/ CAM-generated partial crowns. Eur J Oral Sci, 111(2), 163-169, 2003. https://doi.org/10.1034/j.1600-0722.2003.00022.x
  5. Bindl A, Luthy H, Mormann WH. Strength and fracture pattern of monolithic CAD/CAM generated posterior crowns. Dent Mate, 22(1), 29-36, 2006. https://doi.org/10.1016/j.dental.2005.02.007
  6. Choi SM, Nam SY. Evaluation of color change according to coloring time of dental zirconia block. The Korean Academy Of Dental Technology, 33(3), 219-224, 2011
  7. Crispin BJ, Hewlett E, Seghi R. Relative color stability of ceramic stains subjected to glazing temperatures. J Prosthet Dent, 66(1), 20-23, 1991. https://doi.org/10.1016/0022-3913(91)90345-W
  8. Douglas RD, Przybylska M. Predicting porcelain thickness required for dental shade matches. J Prosthet Dent, 82(3), 143-149, 1999. https://doi.org/10.1016/S0022-3913(99)70147-2
  9. Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. Dental Materials, 20(5), 449-456, 2004. https://doi.org/10.1016/j.dental.2003.05.002
  10. Huh SY, Son HJ, Kim HY, Kim JH. The effect of veneering techniques on the color parameters of Y-TZP based all ceramic restoration of varying ceramic core thickness. Journal of Dental Hygiene Science, 12(2), 123-129, 2012. https://doi.org/10.13065/jksdh.2012.12.1.123
  11. Jeong HC. fracture strength of zirconia monolithic crowns. The Journal of the Korean academy of prosthodontic society, 44(2), 157-164, 2006.
  12. Johnston WM, Kao EC. Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res, 68(5), 819-822, 1989. https://doi.org/10.1177/00220345890680051301
  13. Kim IJ, Lee YK, Lim BS, Kim CW. Effect of surface topography on the color of dental porcelain. Journal of Materials Science: Materials in Medicine, 14(5), 405-409, 2003. https://doi.org/10.1023/A:1023206716774
  14. Lee YK, Cha HS, Ahn JS. Layered color of allceramic core and veneer ceramics. J Prosthet Dent, 97(5), 279-286, 2007. https://doi.org/10.1016/j.prosdent.2007.03.010
  15. McLean JW. Dental ceramics. Proceedings of the First International Symposium on Ceramics. Chicago: Quintessence Publishing Co, 27, 1983.
  16. McMauch DR. A comparative analysis of the colour matching ability of dentists dental students and ceramic technicians. Aust Dent J, 22(3), 165-167, 1977. https://doi.org/10.1111/j.1834-7819.1977.tb04482.x
  17. O'Brien WJ, Groh CL, Boenke KM. A new, smallcolor difference equation for dental shades. J Dent Res, 69(11), 1762-1764, 1990. https://doi.org/10.1177/00220345900690111001
  18. Ocana M, Gonzalez-Elipea AR, Andres-Vergesb M, Tartaj P, Serna CJ, Orerad VM. Preparation by hydrolysis of aerosols and colour properties of Cr-doped and Co-doped zircon powder. J Eur Ceram Soc, 18(7), 821-830, 1998. https://doi.org/10.1016/S0955-2219(97)00208-2
  19. Peris V, Behr M, Hahnel S, Handel G, Rosentritt M. In vitro failure and fracture resistance of veneered and full-contour zirconia restorations. Journal of Dentistry, 40(11), 921-928, 2012. https://doi.org/10.1016/j.jdent.2012.07.010
  20. Preston JD. Current status of shade selection and color matching. Quintessence Int, 16(1), 47- 58, 1985.
  21. Rosenblum MA, Schulman A. A review of allceramic restoration. J Am Dent Assoc, 128(3), 297-307, 1997. https://doi.org/10.14219/jada.archive.1997.0193
  22. Sceeram KJ, Srinivasan R, Devi JM, Nair BU, Ramasami T. Cerium molybdenum oxides for environmentally benign pigments. Dyes and pigment, 75(3), 687-692, 2007. https://doi.org/10.1016/j.dyepig.2006.07.021
  23. Shah K, Nolloway JA, Denry IL. Effect of coloring with various metal oxides on the microstructure, color and flexural strength of 3Y-TZP. J Biomed Mater Res B Appl Biometer, 87(2), 329-337, 2008.
  24. Suarez MJ, Lozano JF, Paz Salido M, Marti nez F. Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs. J Prosthodont, 17(1), 38-38, 2004.
  25. Xiao Ping Luo, Lei Zhang. Effect of veneering techniques on color and translucency of YTZP. J Prosthodont, 19(6), 465-470, 2010. https://doi.org/10.1111/j.1532-849X.2010.00610.x
  26. Yeom MO, Lee JH, Shin SY, Sin SC, Cho JW. The study on the shade color change that depends on the kind of zirconia core and the porcelain thickness. The Korean Academy Of Dental Technology, 32(4), 349-358, 2010.

Cited by

  1. Effects of Children's Drinks on the Color Stability of Strip and Zirconia crown vol.44, pp.3, 2017, https://doi.org/10.5933/JKAPD.2017.44.3.306
  2. 치과용 지르코니아 착색제의 건조정도가 지르코니아 색조에 미치는 영향 vol.19, pp.8, 2013, https://doi.org/10.5762/kais.2018.19.8.176
  3. 치과 CAD/CAM 시스템 보유 현황 및 사용 만족도 조사 연구 vol.42, pp.1, 2020, https://doi.org/10.14347/kadt.2020.42.1.45