• Title/Summary/Keyword: dental Implants

Search Result 1,479, Processing Time 0.03 seconds

The effect of the thread depth on the mechanical properties of the dental implant

  • Lee, Sun-Young;Kim, Sung-Jun;An, Hyun-Wook;Kim, Hyun-Seung;Ha, Dong-Guk;Ryo, Kyung-Ho;Park, Kwang-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.115-121
    • /
    • 2015
  • PURPOSE. This study aimed to evaluate the effect of implant thread depth on primary stability in low density bone. MATERIALS AND METHODS. The insertion torque was measured by inserting Ti implants with different thread depths into solid rigid polyurethane blocks (Sawbones) with three different bone densities ($0.16g/cm^3$, $0.24g/cm^3$, and $0.32g/cm^3$). The insertion torque value was evaluated with a surgical engine. The static compressive strength was measured with a universal testing machine (UTM) and the Ti implants were aligned at $30^{\circ}$ against the loading direction of the UTM. After the static compressive strength test, the Ti implants were analyzed with a Measurescope. RESULTS. The Ti implants with deeper thread depth showed statistically higher mean insertion torque values (P<.001). Groups A and group B had similar maximum static compressive strengths, as did groups C and D (P>.05). After the static compressive strength, the thread shape of the Ti implants with deeper thread depth did not show any breakage but did show deformation of the implant body and abutment. CONCLUSION. The implants with deeper thread depth had higher mean insertion torque values but not lower compressive strength. The deep threads had a mechanical stability. Implants with deeper thread depth may increase the primary stability in areas of poor quality bone without decreasing mechanical strength.

A study on treatment satisfaction and oral health-related quality of life (OHIP-14) among implant patients (임플란트 환자의 치료 만족도 및 구강건강관련 삶의 질(OHIP-14)에 관한 연구)

  • Kim, Soo-Kyung;Park, Min-Young;Byeon, Eun-Hee;Yang, Shin-Hee;Choi, Sun-Ju;Jung, Eun-Seo
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.5
    • /
    • pp.741-750
    • /
    • 2018
  • Objectives: This study aimed to investigate factors affecting treatment satisfaction of patients with dental implants and quality of life. Methods: A questionnaire survey was conducted for adults who underwent dental implant treatment. at dental departments of general hospitals or dental clinics in Seoul and Gyeonggi-do. Data was analyzed to get descriptive statistics of variables, and was under independent t-test, one way ANOVA, and multiple regression analysis. Results: The mean of total satisfaction with implants was $3.73{\pm}0.41$ in the 5-point scale, and that of general satisfaction was $3.97{\pm}0.53$, followed by mean values of psychological satisfaction of $3.68{\pm}0.51$, aesthetic satisfaction of $3.67{\pm}0.49$, and masticatory function of $3.65{\pm}0.53$. Factors that affect implant treatment satisfaction among patients were monthly income (more than 4 million won), hesitation of the procedure (treatment period), regular checkup (yes) and concerns during treatment (work). Factors that affect the quality of life of patients who underwent implant treatments were satisfaction of aesthetic function and overall satisfaction. Conclusions: The above results showed that the higher the aesthetic satisfaction and overall satisfaction with the implant are, the higher the quality of life of patients get. Therefore, it is necessary for dental specialists to perform dental implants well to improve quality of life of patients.

A retrospective statistical analysis of dental implants (치과 임플란트 환자의 통계 분석에 관한 후향적 연구)

  • Zhao, Chun-Ri;Cho, In-Ho;Moon, Eun-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.266-272
    • /
    • 2009
  • Statement of problem: The number of edentulous patients is increasing due to an aging society, which leads to increased demands and interests on implant restorations. Implant restorations are an effective treatment method for both complete and partially edentulous patients, and the success rate has been reported to be high. But because of the increased use of implants in various situations have resulted in frequent reports of failures on implant restorations. Various efforts to overcome these failures have been made. Purpose: The aim of this study was to investigate the statistic survival rate of dental implants on patients who were treated at Dankook University Dental Hospital during the past 10 years based on their charts. Materials and methods :The research was made for two different periods of time; The first investigation was for patients from August, 1998 to August, 2003 and the second was for patients from September, 2003 to April, 2007. Information on the number of implants placed, the location and distribution of implants, the duration between the first and second surgery, and the survival rate of implants were investigated from the patients'charts. Results: 1. According to the first investigation, 1680 implants were placed on 612 patients and the second investigation showed 2438 implants placed on 933 patients. Thus a total of 4118 implants on 1545 patients. 2. Among the 1545 patients, 884 patients were male (57.2 %) and 661 patients were female (42.8%). Out of 4118 implants, 1739 implants (42.2%) were placed on the maxilla, and 2379 implants (57.8%) on the mandible. Implants were placed most frequently in the posterior region of the mandible. A total of 2043 implants (53.2%) were placed in this region. 3. According to the first investigation, 57 out of 1680, implants failed, while from the second investigation, 17 out of 2438 implants were reported as failure. In total, 74 implants failed, which results in a 98.2% survival rate. 4. The average duration between the first and the second surgeries in maxillas decreased from 7.4 months to 6.8 months. The duration also decreased from 5.6 months to 5.0 months in mandibles. Conclusion: As shown in the results, the number of placed implants and the survival rate of implants were higher in the second investigation than that of the first investigation. And the time spent after the first surgery to the second surgery was less in the second investigation. Consequently, it can be presumed that the demand and consumption of dental implants as well as the survival rate will increase in the future.

Cumulative survival rate of Astra Tech implants: a retrospective analysis

  • Kim, Jung-Soo;Sohn, Joo-Yeon;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Lee, Jae-Hoon;Shim, June-Sung;Lee, Keun-Woo;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.2
    • /
    • pp.86-91
    • /
    • 2011
  • Purpose: The aim of this study was to analyze the short-term predictability and reliability of Astra Tech implants according to the demographical distribution of patients and condition of implant sites and location of implants. Methods: Among patients treated with Astra Tech implant (Astra Tech AB) in the Department of Periodontology at the Dental Hospital of Yonsei University of College of Dentisry and K Dental Clinic from May 2004 to March 2009, 195 implants in 98 patients which had been restored more than 6 months ago were reviewed in this study. Following data were reviewed from patient charts and implants success rate was examined: 1) patient type and implant location, 2) bone status at the implant site, 3) diameter and length of the placed implants, 4) presence or absence of bone augmentation and types of the augmentation. Results: The results from this study are as follows: 1) most implants were placed in the molar area, especially 1st molar area of maxilla, 2) most implants were placed at $D_2$ and $D_3$ bone type, 3) most implants were placed in areas of B and C bone quantity, 4) autogenous and alloplastic bone graft and artificial membrane were used for placement of 74 implants. Conclusions: Short-term survival rate of Astra Tech implants was 100%.

A Study on Ultrasonic Image Diagnosis Methods of Tooth Defect with Phased-Array Techniques (위상배열기법을 이용한 치아결함 초음파이미지 진단기술개발)

  • Oh, Yun-Jung;Hwang, In-Nam;Park, Su-Jung;Im, Kwang-Hee;Cho, Hyun-Joon;Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.604-613
    • /
    • 2009
  • Recently, researches to develop phased array ultrasonic examination techniques are proceeded to diagnose dental caries and the status of surgical operation of dental implant. Sound field analysis of phased array ultrasonic transducers were carried out in order to characterizing the ultrasonic phased array beams. The sound field of ultrasonic radiation was calculated for the sample called "gypsum-improved stone" with the similar characteristics of dental materials. Industrial phased array ultrasonic devices were utilized for the insptriion of the artificial flaws machined in the gypsum-improved stone. Dental implants were made at the pig jaw bone and defect images were confirmed for the dental implants.

  • PDF

Biomechanical Property of Dental Implants due to Chewing Force and Bone Properties. (저작력과 골질에 따른 치과용 임프란트의 생체 역학적 특성)

  • 손준희;채수원;권종진;한석환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1316-1319
    • /
    • 2003
  • The micromovements and stress distributions of cancellous bone in dental implant system play important roles in evaluating chewing function of an implant system. The micromovements and stress distributions in dental implant system generally depend on the chewing force and bone properties. Three dimensional nonlinear finite element analysis has been employed to investigate this issue quantitatively. Chewing forces and bone properties are classified into several groups and three types of implants involving one classical cylindrical type and two expandable implants are investigated in this paper.

  • PDF

Photoelastic Study on Stress Distribution of the Fixed Partial Dentures with Various Designed Endosseous Implants (수종 골내 임플란트의 보철 수복물에 가해진 응력 분산에 관한 광탄성학적 연구)

  • Lee, Nung-Soo
    • The Journal of the Korean dental association
    • /
    • v.25 no.12 s.223
    • /
    • pp.1145-1156
    • /
    • 1987
  • The purpose of this experimental study was to analyze the stress distribution from fixed partial dentures to the surrounding structures. This study was carried out on the experimental bridges with K-L blade, F.D.B.I.-11 type, F.D.B.I.-21 type, shape-memory metal blade and two-Apacerams as posterior abutment. The stress patterns and fringes were observed through the circular transmission polariscope. The results of this study were obtained as follows: 1. The stress was more concentrated to the roots apex than the implants. 2. In all blade implants, the stress was more concentrated to the distal side than the mesial side. 3. F.D.B.I.-11 type was more stress concentrated than the 21 type. 4. Shape-memory metal blade was the most effective for stress distribution. 5. Apacerams were more stress concentrated than the blde types and in the model of Apaceram with rubber-ring, anterior root was tipped distally.

  • PDF

Conventional loading, is the concept still useful? (임상가를 위한 특집 3 - Conventional loading, 여전히 임상적으로 유용한가?)

  • Yeo, In-Sung
    • The Journal of the Korean dental association
    • /
    • v.51 no.4
    • /
    • pp.204-209
    • /
    • 2013
  • Implant-supported restorations were connected to commercially pure titanium endosteal implants 3 months in mandible and 6 months in maxilla after the implants were inserted into patient jaws. Modifications of titanium implant surfaces have reduced the waiting time for osseointegration, resulting in the development of the early loading concept, which is defined at present as a restoration in contact with the opposing dentition and placed at least 1 week after implant placement, but no later than 2 months afterward. Nowadays, immediate loading protocols have also been introduced, using the implants that are designed to enhance initial stability. Immediate loading eliminates the edentulous period of a patient. Although dentists widely accept these concepts of early and immediate loading, they agree the conventional loading concept is still necessary, which describes loading protocols later than 2 months after implant insertion. The timing of loading is determined mainly by the factors of a patient. This paper considers for what dental clinicians should be careful in implant-supported restoration procedures, considering the implant late failure.

Rehabilitation using short implants in the mandibular fully edentulous patient with severe alveolar bone loss: a case report (치조골 흡수가 심한 하악 완전 무치악 환자에서 짧은 임플란트를 이용한 고정성 보철 수복 증례)

  • Hwang, Hee-Sun;Lee, Ki-Young;Kim, Yu-Lee
    • The Journal of the Korean dental association
    • /
    • v.54 no.9
    • /
    • pp.692-702
    • /
    • 2016
  • A short dental implant is considered as possible solution in difficult clinical situations for the placement of a regular length implant. Using a short implant avoiding more invasive surgical procedures simplifies the treatment plan and shortenes the duration of treatment. In this case, 71-year-old female came up with discomfort from her old mandibular denture. As she had fully edentulous mandible and got a negative feedback from removable denture, implant-supported fixed prosthesis was planned. Six short implants were placed on her mandible with severe alveolar bone loss. After 1 year follow up period, implants were well retained with any other abnormal findings. The patient was satisfied with her prostheses and satisfactory outcomes were attained in terms of both esthetic and functional clinical results.

  • PDF

Factors Associated with the Stability of Two-part Mini-implants for Intermaxillary Fixation

  • Kim, Seong-Hun;Seo, Woon-Kyung;Lee, Won;Kim, In-Soo;Chung, Kyu-Rhim;Kook, Yoon-Ah
    • Journal of Korean Dental Science
    • /
    • v.2 no.2
    • /
    • pp.24-30
    • /
    • 2009
  • Two component orthodontic C-implants have been introduced as intermaxillary fixation (IMF) screws in cases of periodontal problems with bone loss, severely damaged teeth, or short roots. This retrospective research sought to investigate the complications and risk factors associated with the failure of two-part C-implants for IMF cases and to show the possible indications compared to one-component mini-implants. The study sample consisted of 46 randomly selected patients who had a total of 203 implants. Pearson chi-square tests of independence were used to test for associations among categorical variables. At least 19 of the total 203 implants failed (9.3%). There was no significant difference in implant failure due to gender, oral hygiene, and placement, although a significant difference due to soft tissue characteristics and root contact was observed. The two-component design of the mini-implant is reliable for difficult IMF cases. Note, however, that the factors influencing implant failure were found to be age, root damage, and condition of soft tissues.

  • PDF