• Title/Summary/Keyword: dental Implants

Search Result 1,477, Processing Time 0.027 seconds

Influence of dental implantation on bone mineral density distribution: a pilot study

  • Lee, Damian Jae-whan;Moon, Eun-sang;Stephen, Kenneth;Liu, Jie;Kim, Do-Gyoon
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.143-149
    • /
    • 2022
  • PURPOSE. Masticatory loading triggers active bone remodeling, altering alveolar bone mineral density (BMD). While dental implants are placed to bear masticatory loading, their influence on changing bone properties has not been fully investigated. Objective of this pilot study was to examine whether the dental implantation has an effect on BMD distribution of bone by comparing dentate, edentulous, and edentulous patients with implants. MATERIALS AND METHODS. Cone beam computed tomography (CBCT) images of 19 partially edentulous patients (Dent), 19 edentulous patients (Edent), and 16 edentulous patients who received implants in the mandible (Edent+Im), were obtained. CBCT images were also obtained from 5 patients within Edent+Im group, before implant placement and after implant loading. Basal cortical bone region of the mandible was digitally isolated. A histogram of gray levels proportional to BMD was obtained to assess mean, histogram standard deviation (HSD), fifth percentile of low and high values (Low5 and High5) of the BMD distribution. Multivariate analysis of variance and paired t-test were used to compare the BMD parameters among the 3 dental status groups and between pre- and post-implantation, respectively. RESULTS. Edentulous patients with implants had significantly greater HSD and High5 values compared to edentulous patients (P < .013). All other comparisons were not significant (P > .097). Mean, HSD, and High5 values significantly increased after receiving implants (P < .022). CONCLUSION. The current findings suggested that receiving dental implants promoted oral bone mineralization for edentulous patients. The longitudinal investigation could provide valuable information on understanding the effects of implantation on the behavior of oral bone quality.

A 10-year follow-up study on clinical outcomes of dental implant rehabilitation using surgical guide

  • Haoyun Li;Mi Young Eo;Kezia Rachellea Mustakim;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.2
    • /
    • pp.70-79
    • /
    • 2024
  • Objectives: The surgical guide is a static computer-assisted device used for implant surgery planning and guidance. By taking an impression and referring to the patients' three-dimensional computed tomography scan of the desired implant site, a surgical guide can be created. During surgery, the surgical guide aids in achieving the designed implant placement position and direction. We examined and evaluated the long-term clinical outcomes of implant surgery using surgical guides. Materials and Methods: This study investigated a total of 15 patients with 32 implants that were placed using surgical guides from 2009 to 2011 with a mean follow-up period extended beyond 10 years. Patient demographics and implant survival rates were recorded. We analyzed marginal bone loss (MBL) by assessing the radiographs acquired at installation, three months after installation, and one month, one, two, and five years after prosthesis delivery. Results: The mean patient age was 57.33 years at implant placement. Of the 32 implants, five implants were placed in the anterior region and 27 implants were in the posterior region. Six implants failed and three of them were replaced, resulting in an 81.25% survival rate. The mean follow-up period was 10 years and nine months. Mean MBL compared to post-installation was significantly higher than at three months after installation, and one month, one, two, and five years after prosthesis delivery. Mean MBL at three months after installation, and one month, one year, and two years were significantly higher compared to the previous visit (P<0.05). However, MBL at five years after prosthesis delivery did not differ significantly compared to at two years. Conclusion: In this study, implant rehabilitation assisted by surgical guides exhibited favorable survival rates. With the limitation of the sample amount in this study, further research and more samples are required to evaluate the long-term clinical effectiveness of surgical guides.

An Overview of Research Trends in Antibacterial Coatings on Titanium Implants (임상가를 위한 특집 3 - 티타늄 임플란트의 항균코팅 동향)

  • Kim, Woo-Hyun;Kim, Kyoung-Nam
    • The Journal of the Korean dental association
    • /
    • v.48 no.2
    • /
    • pp.113-118
    • /
    • 2010
  • Titanium and titanium alloys are the most common materials used for dental and biomedical implants, owing to their biocompatibility and favourable mechanical properties. However infection of the region surrounding a dental implant by pathogenic microorganisms is a significant factor in implant failure. Prevention and control of microbial colonization of implant surfaces is considerable interest to the biomedical community. One important strategy is to render the implant surface antibacterial by impeding the formation of biofilm. A number of approaches have been proposed for this purpose. Therefore, we reviewed the researches of antibacterial coatings on titanium implants in this articles.

A 5-year prospective clinical study of Neobiotech implants for partially edentulous patients (부분 무치악환자에서 Neobiotech 임플란트의 5년 전향적 임상연구)

  • Labriaga, Wilmart;Hong, Ju-Hee;Park, Jin-Hong;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.272-278
    • /
    • 2017
  • Purpose: The aim of the present prospective clinical study was to assess the cumulative survival rate (CSR) of Neobiotech implants restored with fixed partial prosthesis in relation to its potential risk factors. Materials and methods: Thirty six partially edentulous patients received Neobiotech implants and implant supported fixed partial prosthesis at Korea University Guro Hospital Dental Center from November 2009 until November 2011. The observation period was set from the implant placement and the last clinical visit until December 2015. Implant survival rate was determined using the Kaplan-Meier method. The relationship between implant survival rate and the potential risk factors were analysed using the multi Cox proportional analysis (P<.05). Results: A total of 69 implants were placed in 36 patients after a mean observation period of 45.9 months. Two out of 69 implants failed before loading, yielding a 5-year cumulative survival rate of 97.1%. The maxillary implants have a lesser CSR than the mandibular implants based on log rank test analysis (maxilla=91.3%; mandible=100% P<.05). However, the multi Cox proportional analysis showed that implant location has no significant correlation with implant failure (P>.05). Conclusion: Neobiotech implants showed predictable results with a 5 year cumulative survival rate of 97.1%.

Unusual malignant neoplasms occurring around dental implants: A report of 2 cases

  • Oh, Song Hee;Kang, Ju Hee;Seo, Yu-Kyeong;Lee, Sae Rom;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.59-65
    • /
    • 2018
  • Osseointegrated implants are now commonplace in contemporary dentistry. However, a number of complications can occur around dental implants, including peri-implantitis, maxillary sinusitis, osteomyelitis, and neoplasms. There have been several reports of a malignant neoplasm occurring adjacent to a dental implant. In this report, we describe 2 such cases. One case was that of a 75-year-old man with no previous history of malignant disease who developed a solitary plasmacytoma around a dental implant in the left posterior mandible, and the other was that of a 43-year-old man who was diagnosed with squamous cell carcinoma adjacent to a dental implant in the right posterior mandible. Our experiences with these 2 cases suggest the possibility of a relationship between implant treatment and an inflammatory cofactor that might increase the risk of development of a malignant neoplasm.

Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae

  • Choi, Jung-Yoo;Sim, Jae-Hyuk;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.3
    • /
    • pp.182-192
    • /
    • 2017
  • Purpose: Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. Methods: Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. Results: The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. Conclusions: This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2.

Long-term Retrospective Clinical Study Comparing Submerged Type with External Hex Connection and Non-submerged Type with Internal Morse Taper Connection Implants

  • Kwoen, Min-Jeong;Kim, Sang-Yun;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • v.12 no.1
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose: This study was aimed to compare the survival and success rates, and long-term crestal bone loss according to the use of 2 connection types of dental implants (submerged-USII and non-submerged-SSII; Osstem $Implant^{(R)}$) by analyzing the change in alveolar bone height after 1 year under load and during final follow-up period. Materials and Methods: Between December 2004 and August 2008, patients with two types of Osstem implants (USII and SSII) were retrieved retrospectively. A total of 92 patients with 284 implants (USII=60, SSII=224) was finally selected. Their mean follow-up period was 7.5 years. The mesial and distal alveolar crestal bone changes were measured using radiographic images and the average was calculated at 1 year after loading and during final follow-up period. Result: Among the 284 implants, 4 USII and 7 SSII implants were removed, indicating 93.3% and 96.9% survival rates. Of the survived implants, mean crestal bone loss 1 year after loading was 0.39 mm for USII and 0.19 mm for SSII (P=0.018). During the final follow-up, mean crestal bone loss was 0.63 mm and 0.35 mm for USII and SSII, respectively, without statistical significance (P=0.092). According to the criteria for the success and failure of the implant by Albreksson and colleagues, final success rate was estimated as 86.7% for USII and 91.5% for SSII, respectively. Conclusion At 1 year after loading, the average crestal bone loss was significantly different between USII and SSII; however, both types met the criteria for implant success. During the final follow-up, both groups showed insignificant bone resorption patterns and did not show any pathological clinical symptoms. Therefore, both implants exhibited high long-term stability.

COMPARATIVE STUDY OF OSSEOINTEGRATION OF 4 DIFFERENT SURFACED IMPLANTS IN THE TIBIA OF DOGS (성견 경골에서 표면처리방법이 다른 4종의 임프란트 골유착에 관한 비교연구)

  • Hong, Who-Suk;Kim, Tae-Hee;Ryu, Seong-Hee;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.46-54
    • /
    • 2005
  • Purpose: This study was performed in order to compare the osseointegration of 4 different surfaced implants in the dog's tibia which has thick dense cortical bone and loose marrow space. Materials & methods: Four mongrel dogs and four different surface types of implants, smooth surfaced AVANA implants, RBM surfaced AVANA implants, HA-coated Steri-Oss implants and SLA Bicon implants, were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics: Control group, RBM group, HA group, and SLA group. Three implants of each group were installed into the metaphysis of tibia of adult dogs. The animals were sacrificed at 8 weeks after implantation. The undecalcified specimens were prepared for histological examination and histomorphometric analysis of implant-bone contact ratios. Results: Radiographically and histologically good osseointegration of implant was observed in the dense cortical bone, but poor osseointegration was observed in the marrow space. Histologically more bone apposition to implant surface was found in rough surfaced groups than the smooth surfaced, Control group. In histomorphometric findings of cortical bone the average bone-implant contact ratios of HA group (95.4%, p<0.01), RBM group (87.1%, p<0.05), and SLA group (86.0%, p<0.05) were significantly higher than that of Control group (75.9%). In marrow space the average bone-implant contact ratios of HA group (76.1%, p<0.01) and SLA group (45.4%, p<0.05) were significantly higher than that of Control group (29.6%). The ratio of RBM group was higher than that of Control group but there was no significantly difference between RBM group and Control group. Conclusion: These results suggest that the rough surfaced implants can obtain the better osseointegration than the smooth surfaced implant in the cortical and marrow space and that HA-coated implants can obtain the best osseointegration in the marrow space among them.

Effectiveness of dental implantation with the partial split-flap technique on vertical guided bone regeneration: a retrospective study

  • Cho, Young-Dan;Kim, Sungtae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.6
    • /
    • pp.433-443
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effectiveness of the partial split-flap technique with a K-incision on vertical guided bone regeneration (vGBR) and to retrospectively analyze the clinical and radiographic outcomes of dental implantation using this approach. Methods: In total, 78 patients who received 104 dental implants with vGBR, categorized as (1) pre-GBR and post-implantation and (2) simultaneous GBR and implantation, were enrolled. Data analysis was based on periapical radiographs, clinical photos, and dental records. The 2-sample t-test was used to compare the 2 surgical procedures. Results: The baseline vertical bone level, augmented bone height (ABH), and treatment duration were significantly higher in the pre-GBR procedure group. The survival rates of the implants were 96.1% and 94.8% in implant- and patient-based analyses, respectively. In Cox regression analysis, high rates of implant failure were found in the presence of ABH of ≥4 mm, smoking, and diabetes. Conclusions: Within the limitations of this retrospective study, the partial split-flap technique using a K-incision for vGBR showed stable clinical outcomes and favorable dental implant survival.

Assessment of trabecular bone changes around endosseous implants using image analysis techniques: A preliminary study

  • Zuki, Mervet El;Omami, Galal;Horner, Keith
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.129-135
    • /
    • 2014
  • Purpose: The objective of this study was to assess the trabecular bone changes that occurred around functional endosseous dental implants by means of radiographic image analysis techniques. Materials and Methods: Immediate preoperative and postoperative periapical radiographs of de-identified implant patients at the University Dental Hospital of Manchester were retrieved, screened for specific inclusion criteria, digitized, and quantified for structural elements of the trabecular bone around the endosseous implants, by using image analysis techniques. Data were analyzed using SPSS version 11.5. P values of less than 0.05 were considered statistically significant. Results: A total of 12 implants from 11 patients were selected for the study, and 26 regions of interest were obtained. There was a significant increase in the bone area in terms of the mean distance between nodes (p=0.006) and a significant decrease in the marrow area in terms of the bone area (p=0.006) and the length of marrow spaces (p=0.032). Conclusion: It appeared that the bone around the implant underwent remodeling that resulted in a net increase in bone after implant placement.