• Title/Summary/Keyword: dental Implantation

Search Result 266, Processing Time 0.024 seconds

PRELIMINARY STUDY ON "RIDGE SPLITTING TECHNIQUE" IN HORIZONTALLY DEFICIENT ALVEOLAR RIDGE (위축된 치조골에서 치조골 수평 확장술을 이용한 임플란트 이식술에 관한 임상연구)

  • Park, Young-Ju;Nam, Jeong-Hun;Song, Jun-Ho;Yeon, Byung-Moo;Noh, Kyung-Lok;Pang, Eun-O;Chung, Jae-An;Shin, Jin-Eob;Kang, Eung-Seon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.4
    • /
    • pp.314-318
    • /
    • 2009
  • The aim of this study was to evaluate the clinical applicability of a ridge splitting technique for reconstruction of narrowed edentulous alveolar ridges for dental implantation. 41 patients with 47 edentulous areas were included in this study. After corticotomy of a rectangular buccal segment and about 3-4 weeks healing period, the alveolar ridge was splitted, implant was placed. The initial ridge width varied between 2.5 and 7.0mm, average was 3.99mm. 68 dental implants were placed, and the gap between the implants and the bone is filled with various bone graft material, or none. All splitted sites showed sufficient bone volume for insertion of the implants at the moment of implantation. Over 1 year of follow-up period, five implants(7.3%) had mobility in two patients, among them, 2 implants(2.9%) sustained infection and removed. And any other complications were not noted. Our conclussion is that ridge splitting of the narrow edentulous area is a reliable and safe procedure in horizontally deficient ridges.

AUGMENTED BONY CHANGE FOLLOWING PLATELET RICH PLASMA(PRP) APPLICATION ON MAXILLARY DEFECT (악골결손부에 PRP적용후 획득된 골의 변화량)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.219-225
    • /
    • 2003
  • Purpose: Platelet Rich Plasma(PRP) application is increasing with sinus inlay bone graft, but there is few research with radiographic ananlysis on effect of PRP in maxillary sinus. The author investigated the amount of bony changes of maxillary sinus for dental implantation among the patients with maxillary inlay graft. Materials and Methods: With 10 patients who were treated with sinus inlay autologous bone grafting combined with PRP technique, and with 5 patients who were treated with sinus inlay grafting only without PRP, the panoramic radiographys which were taken at preoperation, immediate postoperation, 3months postoperation, and 4 months postoperation(a month after dental implantation)periods were analysed. The films had been scanned, and then proceeded throughout image analysis system. The bone density of maxillary grafted sites was compared with adjacent tooth enamel density and remeasured according to density luminosity of each film. The density changes on PRP group and bone graft only group were analysed with non-parameteric statistics method. Results: In PRP combined patients group, bone density on postoperation periods was increased totally. The remarkable enhanced change of bone density was observed on 3 months postoperation period, thereafter the increasing rate was slightly reduced. In only bone graft patients group, bone density on postoperation periods was also increased compared with preoperation period, but the bone density of 4 months postoperation period was decreased compared with 3 months postoperation period. The amount of bone density on PRP group was significantly changed according to periods in contrast to bone graft only group. Conclusion: The bone density on PRP group was remarkably increased at 3 months postoperation compared to bone graft only group and it was seemed to be associated with more new bone formation, less grafted bone resorption at bone grafted sites with PRP.

Retrospective study on marginal bone loss around maxillary anterior implants with or without bone graft (상악 전치부에서 골 이식 유무에 따른 임플란트 변연골 소실에 관한 후향적 연구)

  • Hwang, Hee-Sun;Jung, Ji-Hye;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: This study is to evaluate the clinical significance of implantation with simultaneous bone graft by comparing the marginal bone loss around maxillary anterior implants with or without bone graft. Materials and methods: Patients treated with implant-retained restorations on maxillary anterior region at Implant Center, Dental Hospital, Wonkwang University between June 2011 and May 2014 were included in this study. Date of implant placement, implant diameter, implant length, implant-abutment connection type and whether the bone graft was done were investigated. The patient's periapical radiographs taken immediately after implantation and at the most recent visit were compared. Marginal bone loss was measured using Emago advanced v5.6 program (Oral diagnostic systems, Amsterdam, Netherlands). Statistical analysis was done in independent t-test by using SPSS 22.0 program. Results: As a result of observing on 83 implants (without bone graft: 44, with bone graft: 39) of 52 patients for 6 - 45 months (average: 18.4 months), implants without bone graft showed $1.42{\pm}0.42mm$, implants with bone graft showed $1.28{\pm}0.45mm$ of marginal bone loss. Conclusion: In limitations of this study, implants with simultaneous bone graft had significantly less marginal bone loss than implants without bone graft.

Distribution of the lingual foramina in mandibular cortical bone in Koreans

  • Kim, Dae Hyun;Kim, Moon Yong;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.6
    • /
    • pp.263-268
    • /
    • 2013
  • Objectives: The interforminal region, between the mandibular foramen, is known as a relatively safe area that is free of anatomic structures, such as inferior alveolar nerve, submandibular fossa, and lingual side of the mandible is occasionally neglected for its low clinical importance. Even in the case of a severely constricted alveolus, perforation of the lingual cortical bone had been intended. However, anterior extension of the inferior alveolar canal, important anatomic structure, such as concavity of lingual bone, lingual foramina, and lingual canal, has recently been reported through various studies, and untypical bleeding by perforation of the lingual plate on implantation has also been reported. Therefore, in this study, we performed radiographic and statistical analysis on distribution and appearance frequencies of the lingual foramina that causes perforation of the mandibular lingual cortical bone to prevent complications, such as untypical bleeding, during surgical procedure. Materials and Methods: We measured the horizontal length from a midline of the mandible to the lingual foramina, as well as the horizontal length from the alveolar crest to the lingual foramina and from the lingual foramina to the mandibular border by multi-detector computed tomography of 187 patients, who visited Dankook University Dental Hospital for various reasons from January 1, 2008 to August 31, 2012. Results: From a total of 187 human mandibles, 110 (58.8%) mandibles had lingual foramina; 39 (20.9%) had bilateral lingual foramen; 34 (18.2%) had the only left lingual foramen; and 37 (19.8%) had the only right lingual foramen. Conclusion: When there is consistent bleeding during a surgical procedure, clinicians must consider damages on the branches of the sublingual artery, which penetrate the lingual foramina. Also, when there is a lingual foramina larger than 1 mm in diameter on a pre-implantation computed tomography, clinicians must beware of vessel damage. In order to prevent these complications and progress with a safe surgical procedure, a thorough radiographic examination before the surgery is indispensable. Further, clinicians should retract lingual flap definitely to confirm the shape of the lingual bone and existence of the lingual foramina.

EFFECT OF DIFFERENT SURFACE TREATMENTS TO INCREASE BIOCOMPATIBILITY OF DENTAL IMPLANT (임플랜트 표면처리가 생체활성에 미치는 영향)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Yoon, Tae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.594-605
    • /
    • 2006
  • Statement of problem: Modification of titanium implant surface has potential to ensure clinically favorable performance that several surface modification technologies have been introduced. Among the methods. anodizing method and sol-gel hydroxyapatite coating method have gained much interest due to its roughness and chemical composition of the coating layer, but more of its biocompatibility result is required. Purpose : The purpose of this study was to compare bone-implant interface shear strength of four different surface treated implants as time elapsed. Resonance frequency analysis(RFA) and removal torque measurement methods were employed to measure implant stability at one week and six week after implantation. Material and method: A total of 80 screw-shaped implant [20 machined, 20 resorbable media blasted(RBM), 20 anodized, and 20 anodized+hydroxyapatite sol-gel coated] were prepared, and one of each group was implanted in the tibia of a New Zealand white rabbit that total 20 of them were used. In order to test the implant stability and implant-tissue interface contact changing in the bone bed, each 10 rabbit were sacrificed 1 week and 6 week later while resonance frequency and removal torque were measured. One-way analysis of variance and the Tukey test were used for statistical analysis. Results : The results were as follows. 1. There was no statistically significant difference of implant stability quotients(ISQ) value in RFA between individual groups after 1 week of implantation and 6 weeks(p>0.05). But, there was statistically significant increase of ISQ value in 6 weeks group compared to 1 week group(p<0.05). 2. There was no statistically significant difference in removal torque analysis between individual groups after 1 week of implantation and 6 weeks(p>0.05). but there was statistically significant increase in all 4 groups after 6 weeks compared to 1 week later(p<0.05). 3. There was no statistically significant difference in removal torque analysis between anodized group and HA coating after anodic oxidation 6 weeks later(p>0.05), but significant difference was appeared in both groups compared to RBM group and smooth-machined group(p<0.05). Conclusions : It can be suggested that changes in surface characteristics affect bone reactions. Anodized and anodized+hydroxyapatite sol-gel coating showed significantly improved bone tissue response to implants, but further study on the effect of hydroxyapatite dissolution is needed.

THE EFFECT OF DIFFERENT SURFACE TREATMENT ON THE OSSEOINTEGRATION AND STABILITY OF IMPLANTS (처리 방법이 다른 표면이 임플랜트의 골유착 및 안정성에 미치는 영향)

  • Yang, Seoung-Wook;Lim, Heon-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.606-616
    • /
    • 2006
  • Purpose: This experiment examined the effect of different surface treatment on the osseointegration and stability of implants. Material and methods: In this study, 40 each of machined, SLA and RBM implants, which are the most commonly used implants, were implanted into the tibia of 20 normal rabbits using $OsseoCare^{TM}$. The rabbits were sacrificed after 1 week, 4 weeks, 8 weeks and 12 weeks for implant stability analysis, removal torque analysis, histologic and histomorphometric analysis. Result : ISQ showed significant difference between Machined and RBM at first week and at 4 weeks. There was significant difference between Machined and both SLA and RBM(p<0.05) but after 8 weeks there were no significant difference between each group. In the removal torque, RBM showd significantly higher values than SLA and Machined surface at 1st week. At 4th and 12th week, there was significant difference between Machined and SLA, RBM(p<0.05). In the bone to implant contact variable, there was no significant difference between each surface treatment method. In the Machined surface group, there was no significant difference between each time interval. but in SLA group, there were significant differences between the 1st week and 12th week and in RBM group, there were significant differences between the 1st week and 8th, 12th week and between 4th and 12th week(p<0.05). The bone area showed significantly higher values in SLA and RBM compared to Machined surface 1st and 8th week and significantly higher values in SLA than Machined surface at the 4th week(p<0.05). Conclusion: The roughened surface of implants showed positive effect in the early stages of implantation and assisted in bone formation After the bone formation stage, there was no statistical difference between Machined and roughened surface groups. In dental implantation, where initial stability is critical to the success of implants, the use of roughened surface implants should assist in reducing the healing period after implantation.

Effect of low intensity pulsed ultrasound (LIPUS) on bone healing around a titanium implant in the tibia of osteoporosis-induced rats (골다공증 유도 백서경골에 티타늄 임플란트 매식 시 저출력 초음파 적용이 골 치유에 미치는 영향)

  • Hwang, Young-Seob;Jeon, Hyun-Jun;Shin, Sang-Hun;Chung, In-Kyo;Kim, Gyoo-Cheon;Kim, Chul-Hoon;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.386-395
    • /
    • 2011
  • Introduction: Osteoporosis is a major health problem in the elderly that involves changes in the properties of bone as well as impaired bone healing around a titanium implant in both humans and animals. This study examined effect of low intensity pulsed ultrasound (LIPUS) on the bone healing process around a titanium implant in osteoporosis-induced rats. Materials and Methods: Sixteen rats were divided into two groups. A control group with osteoporosis induced by removing both ovaries and an experimental group of rats that were applied with LIPUS after osteoporosis had been induced. A screw type titanium implant (diameter, 2.0 mm: length, 3.5 mm, Cowell-Medi, KOREA) was placed into the tibias of 16 rats. The control and experimental group contained 8 rats each. The rats were sacrificed at 1, 2, 4, and 8 weeks after implantation to examine the histopathology and immunochemistry. Results: The histopathology examination revealed earlier new bone formation in the experimental group than the control group. In particular, at 1 week after implantation, more new bone matrix and collagen were observed around the implant of the experimental group compared to the control group. Immunochemistry analysis showed that the level of OPG expression of the experimental group was higher in the early stages than in the control group. After 8 weeks, the levels of OPG expression were similar in both groups. The expression level of receptor activator of nuclear factor kB ligand (RANKL) was stronger in the experimental group than the control group. After 4 weeks, the level of RANKL expression was similar in both groups. Conclusion: These results suggest that the application of LIPUS to implantation can promote bone healing around titanium in osteoporosis animals.

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

The Factors Influencing to the Implant Patients Discomfort (임플란트 식립 후 불편감에 영향을 주는 요인)

  • Yoon, Hyun-Seo;Heo, Soo-Hee;Chun, Jin-Ho
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.325-332
    • /
    • 2011
  • To get the evidences for decreasing the discomfort, dissatisfaction, and for improving management of the implant prothesis through assessment implant patients' awareness and discomforts about care of the prostheses. The subjects were 300 implant patients who treated in the 20 dental clinics in Pusan, Ulsan and Daegu. The general characteristics, recognition, maintenance, discomfort and dissatisfaction, and oral hygiene status were collected. Level of the discomfort and dissatisfaction was measured by a 5 Likert scale, and analyzed by the equivalent of 100. The life-span of the implants was overestimated, however, periodic recall check and scaling were underwent. The level of discomfort and dissatisfaction was generally good, but many of them (65.3%) complained the food impaction. As a result of the multiple regression analysis, level of the discomfort and dissatisfaction increased in case of more number of the prosthesis ($\beta$=0.864), however decreased in case of more frequent teeth brushing ($\beta$=0.737), more frequent periodic check ($\beta$=-0.737), longer duration from the implantation ($\beta$=-0.090). It is very important for the implant patients to be recognized that the lack of care may shorten the life-span of the implant prosthesis. Therefore, efforts of the continuous oral hygiene care such as, periodic recall check, scaling, teeth brushing, the correct using of additional oral hygiene product, and education would be more emphasized.

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.