• 제목/요약/키워드: density calibration

검색결과 208건 처리시간 0.025초

Humidity Calibration for a Pressure Gauge Using a Temperature-Stable Quartz Oscillator

  • Suzuki, Atsushi
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.124-127
    • /
    • 2016
  • Humidity calibration for a temperature-stable quartz oscillator (TSQO) was investigated to exclude the influences of relative humidity on the TSQO output in order to use the corresponding devices outdoors. The TSQO output is a voltage that is inversely proportional to the electric impedance of the quartz oscillator, which depends on the viscosity and density of the measured gas. The TSQO output was humidity calibrated using its humidity dependence, which was obtained by varying the relative humidity (RH) from 0 to 100 RH% while other conditions were kept constant. The humidity dependencies of the TSQO output were fit by a linear function. Subtracting the change in the TSQO output induced by the change in humidity, calculated with the function from the experimentally measured TSQO output for a range of 0-100RH%, eliminated the influence of humidity on the TSQO output. The humidity calibration succeeded in reducing the fluctuations of the TSQO output from 0.4-3% to 0.1-0.3% of the average values for a range of 0-100RH%, at constant temperatures. The necessary stability of the TSQO output for application in hydrogen sensors was below one-third of the change observed for a hydrogen leakage of 1 vol.% hydrogen concentration, corresponding to 0.33% of the change in each background. Therefore, the results in this study indicate that the present humidity calibration effectively suppresses the influence of humidity, for the TSQO output for use as an outdoor hydrogen sensor.

국산 이중에너지 방사선흡수 골밀도 장치와 GE Lunar Prodigy의 교차분석 식 도출에 관한 연구 (Cross-Calibration of Domestic Devices and GE Lunar Prodigy Advance Dual-Energy X-Ray Densitometer Devices for Bone Mineral Measurements)

  • 김정수;노영훈;이인주;김경아;이인자;김정민
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.27-31
    • /
    • 2017
  • Reliable follow-up of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA) is essential in clinical practice. When there is a difference in the BMD values from DXA systems in the same patient, cross calibration equation is required for the reliable follow-up. Unfortunately, no equation is existed in BMD measure between GE Lunar Prodigy Advance (US, GE Healthcare; LPA) and Osteosys Dexxum T (Korea, Osteosys; ODT) DXA systems. In this study, we evaluate the agreement of BMD values between LPA and ODT and suggest the cross calibration equation using European spine phantom (ESP) with two systems. We performed BMD measurements using ten scans with ESP in each DXA systems. We compared BMD values and calculated cross calibration equation by linear regression analysis. The comparison between the LPA and ODT bone densitometers used the ESP. Compared to the ESP BMD values, ODT underestimated 14.36% and LPA overestimated 12.96%. The average of total BMD measurement values acquired with ODT were 21.44% lower than those from LPA. Cross-calibration equation for LPA and ODT was derived from ESP. We calculated simple cross calibration equation for LPA and ODT DXA systems. Cross-calibration equation is necessary for the reliable follow-up of BMD values in two different systems.

정전용량을 이용한 미분탄 유량계의 개발 (The Development of Pulverized Coal(PC) Flow-Meter using Capacitance)

  • 김재현;이용식;황건호;정성원;여준호;소지영
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.61-67
    • /
    • 2008
  • 본 논문은 발전소 보일러 및 제철소 고로의 미분탄 연소방식에 적용이 가능한 유량계 개발에 관한 연구로, 정전 용량을 이용한 미분탄 유량계를 개발하였다. 먼저 관에 흐르는 미분탄의 밀도 측정이 가능한 센서 및 회로를 설계하였고, 측정된 데이터를 분석하고 밀도를 계산하는 알고리즘을 구현하였다. 압송시스템에 설치된 로드셀의 출력 데이터와 측정된 데이터를 비교하여 개발된 유량계의 신뢰성을 확인하였다.

고압 밀도계의 보정에 대한 연구 (Calibration of High Pressure Vibrating Tube Densimeter)

  • 김화용;오경실;배원
    • 한국가스학회지
    • /
    • 제9권3호
    • /
    • pp.49-54
    • /
    • 2005
  • 본 연구에서는 넓은 범위의 온도(420 K), 압력(70 MPa)에서 밀도를 측정할 수 있는 Anton Paar DMA 512P vibrating tube densimeter를 보정하고, 장치의 건전성을 확인하였다. 보정을 위해서 기준물질로 물과 질소 그리고 물과 진공의 period를 측정하여 각각을 비교해보았다. 온도는 313.15부터 353.15 K까지 10 K 간격으로 5 isotherms를 측정하였고, 압력은 5부터 30 MPa까지 대략 5 MPa 간격으로 측정하였다. 또한 이산화탄소의 밀도를 측정하여 NIST에 보고된 밀도값과 비교해 보았다. 기준물질로 물과 진공보다 물과 질소를 사용하였을 때 더 좋은 결과를 보였고, 이산화탄소의 경우 측정범위 내에서는 오차가 대략 $0.3\%$로 비교적 낮은 결과를 보였으며 이로써 장치의 건전성을 확인하였다.

  • PDF

MCNP4A 전산코드를 이용한 중성자 수분함량 측정기의 교정식 및 교정상수 도출방법 연구 (A Study on Calibration of Neutron Moisture Gauge Using MCNP4A)

  • 황주호;임천일;송정호
    • Journal of Radiation Protection and Research
    • /
    • 제22권4호
    • /
    • pp.289-298
    • /
    • 1997
  • 중성자 수분함량 측정기의 개발에 있어서 중성자 계측값과 흙속의 수분함량에 대한 관계식을 유도하기 위해서는 공시체 제작 등의 많은 실험을 통해 유도한 교정식이 필요하다. 또한 공시체 제작 및 측정실험의 통계적 오차를 줄이기 위해서는 많은 시간과 노력이 필요하다. 하지만 몬테카를로방법을 사용한 전산코드를 이용하여 수행할 경우 시간과 노력을 줄일 수 있을 뿐만 아니라, 보다 일반적인 흙에 대한 교정식을 얻을 수 있다. 본 연구에서는 중성자의 수송문제를 계산하는데 유용한 MCNP4A 전산코드를 이용하여 실제 실험을 모사하였다. 또한 모사결과를 공시체를 제작하여 실험한 결과와 비교하였다. 비교결과 실제실험의 결과와 모사 범위 내에서 일치함을 알 수 있었다. 중성자 수분함량 측정기의 교정식 도출 및 교정상수를 결정하기 위해 적용할 수 있음을 알 수 있었다. 또한 수분함량 측정기의 계측값에 영향을 미치는 인자중의 하나인 흙의 건조밀도 변화에 대한 영향을 살펴보았다.

  • PDF

Uniform large scale cohesionless soil sample preparation using mobile pluviator

  • Jamil, Irfan;Ahmad, Irshad;Ullah, Wali;Junaid, Muhammad;Khan, Shahid Ali
    • Geomechanics and Engineering
    • /
    • 제28권5호
    • /
    • pp.521-529
    • /
    • 2022
  • This research work deals with the development of air pluviation method for preparing uniform sand specimens for conducting large scale laboratory testing. Simulating real field conditions and to get reliable results, air pluviation method is highly desirable. This paper presents a special technique called air pluviation or sand raining technique for achieving uniform relative density. The apparatus is accompanied by a hopper, shutters with different orifice sizes and numbers and set of sieves. Before using this apparatus, calibration curves are drawn for relative density against different height of fall (H) and shutter sizes. From these calibration curves, corresponding to the desired relative density of 60%, the shutter size of 13mm and height of fall of 457.2 mm, are selected and maintained throughout the pluviation process. The density obtained from the mobile pluviator is then verified using the Dynamic Cone Penetrometer (DCP) test where the soil is poured in the box using defined shutter size and fall height. The results obtained from the DCP test are averaged as 60±0.5 which was desirable. The mobile pluviator used in this research is also capable of obtaining relative densities up to 90%. The instrument is validated using experimental and numerical approach. In numerical study, Plaxis 3D software is used in which the soil mass is defined by 10-Node tetrahedral elements and 6-Node plate is used to simulate plate behavior in the validation phase. The results obtained from numerical approach were compared with that of experimental one which showed very close correlation.

공기중의 라돈 농도 측정을 위한 CR-39의 교정 (Calibration of CR-39 for Measurement of Radon in Air)

  • 박영웅;장시영;하정우;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.18-22
    • /
    • 1989
  • CR-39 고체비적검출기를 교정하기 위하여 밀봉 순환 방식의 고체비적검출기 교정 장치와 밀리포어필터가 부착된 라돈컵을 제작한 후 기지의 라돈농도에 대한 비적 수를 측정하였다. 그 결과 CR-39 고체비적검출기의 단위 면적당 생성된 비적 수에 대한 시간 적분 라돈 농도는 $0.24{\pm}0.09(pCi/l){\cdot}day/(Tr/cm^2)$ 였다.

  • PDF

Dual Energy X-ray 흡수 영상의 분해를 통한 뼈 영역 추출 (Bone Region Extraction by Dual Energy X-ray Absorbtion Image Decomposition)

  • 권주원;조선일;안영복;노용만
    • 한국멀티미디어학회논문지
    • /
    • 제12권9호
    • /
    • pp.1233-1241
    • /
    • 2009
  • 골다공증은 45세 이상의 여성 50% 이상이 갖고 있는 질환이다. 더욱이 질병의 증상을 환자가 느끼지 못하여 병을 심화시키기 때문에 조기 진단으로 골다공증을 예방하는 것이 중요하다. 이를 위해 골밀도(Bone Mineral Density)의 효과적인 측정을 위한 다양한 연구가 국내외적으로 수행되고 있다. 골밀도 측정을 위해서는 X-선 영상이 활용되고 있으며, 이 중에서 이중 에너지 X 선 흡수법(DEXA)을 이용하여 골밀도를 측정하는 방법은 많은 관심을 받고 있는 분야이다. DEXA 영상은 서로 다른 두 에너지준위의 X선으로부터 영상을 획득함으로써 생체조직의 중첩에 의한 잡음을 효과적으로 줄여 진단효과를 높이는데 유용하다. 하지만, DEXA 영상에서 골영역을 추출하기 위해서는 실험적으로 계수를 결정해야 하는 문제점이 있다. 본 논문에서는 두 에너지 흡수 영상에서 골영역을 추출하기 위해 실험적으로 결정하는 변수를 X-선 영상의 물리적 의미와 각 에너지에 반응하는 생체조직들의 감쇠상수 특성을 기반으로 분석하여 골영역을 효과적으로 검출하는 방법을 제안한다. 더불어 다양한 영상을 적용한 실험으로 제안한 알고리즘의 효율성을 확인하였다.

  • PDF

A Method for Absolute Determination of the Surface Areal Density of Functional Groups in Organic Thin Films

  • Min, Hyegeun;Son, Jin Gyeong;Kim, Jeong Won;Yu, Hyunung;Lee, Tae Geol;Moon, Dae Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.793-797
    • /
    • 2014
  • To develop a methodology for absolute determination of the surface areal density of functional groups on organic and bio thin films, medium energy ion scattering (MEIS) spectroscopy was utilized to provide references for calibration of X-ray photoelectron spectroscopy (XPS) or Fourier transformation-infrared (FT-IR) intensities. By using the MEIS, XPS, and FT-IR techniques, we were able to analyze the organic thin film of a Ru dye compound ($C_{58}H_{86}O_8N_8S_2Ru$), which consists of one Ru atom and various stoichiometric functional groups. From the MEIS analysis, the absolute surface areal density of Ru atoms (or Ru dye molecules) was determined. The surface areal densities of stoichiometric functional groups in the Ru dye compound were used as references for the calibration of XPS and FT-IR intensities for each functional group. The complementary use of MEIS, XPS, and FT-IR to determine the absolute surface areal density of functional groups on organic and bio thin films will be useful for more reliable development of applications based on organic thin films in areas such as flexible displays, solar cells, organic sensors, biomaterials, and biochips.

소규모 플랜트 기자재의 고장밀도함수가 가용도에 미치는 영향 평가 (A Study on the Availability Evaluation with Failure Density Function of Equipment of Small-scale Plant)

  • 이홍철;황인주
    • 한국유체기계학회 논문집
    • /
    • 제19권3호
    • /
    • pp.33-36
    • /
    • 2016
  • The investigation on the verification of availability simulation for small-scale plant has been carried out. This study focuses on the availability variation induced by number of equipment and iteration with failure density function. The equipment classification of small-scale plant and failure type and the methodologies on Monte-Carlo simulation are established. The availability deviation with programs showed under Max. 1.7% for the case of normal function. This method could be used to availability evaluation of small-scale plant, but calibration of the failure density function is necessary for general application.