우리나라 상수도시설의 첨두부하 영향요소 분석 (Analysis of the Affecting Factors to the Peak Factor in Water Supply Facilities)

  • 현인환;이제인
    • 상하수도학회지
    • /
    • 제18권1호
    • /
    • pp.49-58
    • /
    • 2004
  • This study is to analyze the affecting factors to the peak factor in the drinking water supply Facilities. The peak factor is a very important element to determine the capacity of the water supply facllities. Several factors such as Population served, average day water demand, ratio of domestic water use, ratio of affairs & business water use and water use per capital per day were selected as the affecting factors in this study. In this study, peak factor characteristics for Korean facilities were compared with those for Japanese ones. As a result, non-exceedance probability was suggested as the designing method for the peak factor. Also, the 50% non-exceedance probability values and the 90% values based on the 1998-1999 data were suggested in this study.

OFDMA 셀룰러 다중홉 네트워크에서 셀 용량을 증가시키는 효율적인 주파수 재활용 방법 (Effective Frequency Reuse Scheme for OFDMA Cellular Multihop Networks for Improving Cell Throughput with Low Outage Ratio)

  • 임성국;전한얼;이재용
    • 한국통신학회논문지
    • /
    • 제35권12A호
    • /
    • pp.1198-1206
    • /
    • 2010
  • 최근 스마트폰 및 타블릿 PC가 차세대 통신단말롤 급부상함에 따라 멀티미디어 서비스에 대한 사용자의 요구 또한 급격히 증가하였다. 기존의 통신네트워크사업자는 셀 용량의 증설을 위해 값이 저렴한 중계기의 도입을 적극 검토하고 있다. 그러나 중계기의 도입은 셀 내의 간섭을 심화시키고 이는 사용자 서비스 품질에 악영향을 미치며 서비스 불능(outage) 비율을 증가시키게 된다. 본 논문에서는 중계기를 사용하는 다중흡 셀룰러 네트워크에서 OFDMA에 적합한 효율적인 주파수 재활용 방법을 제안하여 서비스 불능 확률을 감소시키면서 동시에 데이터 수율을 증가시키고자 한다. 또한 동적 전력제어를 통해 추가적인 성능향상을 보장하며, 셀 전체의 데이터 수율과 서비스 불능 비율의 비교를 통해 성능을 검증한다.

RPSMDSM: Residential Power Scheduling and Modelling for Demand Side Management

  • Ahmed, Sheeraz;Raza, Ali;Shafique, Shahryar;Ahmad, Mukhtar;Khan, Muhammad Yousaf Ali;Nawaz, Asif;Tariq, Rohi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권6호
    • /
    • pp.2398-2421
    • /
    • 2020
  • In third world countries like Pakistan, the production of electricity has been quickly reduced in past years due to rely on the fossil fuel. According to a survey conducted in 2017, the overall electrical energy capacity was 22,797MW, since the electrical grids have gone too old, therefore the efficiency of grids, goes down to nearly 17000MW. Significant addition of fossil fuel, hydro and nuclear is 64.2%, 29% and 5.8% respectively in the total electricity production in Pakistan. In 2018, the demand crossed 20,223MW, compared to peak generation of 15,400 to 15,700MW as by the Ministry of Water and Power. Country faces a deficit of almost 4000MW to 5000MW for the duration of 2019 hot summer term. Focus on one aspect considering Demand Side Management (DSM) cannot oversea the reduction of gap between power demand and customer supply, which eventually leads to the issue of load shedding. Hence, a scheduling scheme is proposed in this paper called RPSMDSM that is based on selection of those appliances that need to be only Turned-On, on priority during peak hours consuming minimum energy. The Home Energy Management (HEM) system is integrated between consumer and utility and bidirectional flow is presented in the scheme. During peak hours of electricity, the RPSMDSM is capable to persuade less power consumption and accomplish productivity in load management. Simulations show that RPSMDSM scheme helps in scheduling the electricity loads from peak price to off-peak price hours. As a result, minimization in electricity cost as well as (Peak-to-Average Ratio) PAR are accomplished with sensible waiting time.

무선 전송환경의 링크품질을 고려한 개선된 AODV 라우팅프로토콜 (Improved AODV Routing Protocol Considering the Link Quality of Wireless Transmission Environments)

  • 이태훈;전승우;김영호
    • 한국정보통신학회논문지
    • /
    • 제20권10호
    • /
    • pp.1903-1911
    • /
    • 2016
  • 오늘날 MANET에 대한 관심의 증대와 더불어 효율적인 MANET 라우팅프로토콜에 대한 연구가 활발히 진행중에 있다. 본 논문은 전술적 MANET 환경에서 Topology의 빈번한 변화와 제한적 무선환경에 적응된 라우팅 프로토콜을 개선하기 위해, 기존의 AODV라우팅 경로설정과정에서 Hop-Count만을 참조하던 방식에서 각 구간의 채널용량을 참조하는 LQA-AODV를 제안하였다. 제안된 LQA-AODV는 기존의 AODV라우팅프로토콜의 경로탐색과정에서 발생하는 RREQ메시지 포맷에 채널용량에 대한 Cost값을 추가하고 경로설정 시 구간별 누적 Cost값을 비교하여 경로를 설정하도록 하였다. 성능검증을 위해 NS2.35를 사용하였으며, 전술무선환경이 반영하기 위해 Link-Qualty모델을 적용하였다. 시뮬레이션은 LQA-AODV와 기존의 AODV를 비교분석하였으며, 그 결과 Packet Delivery Ratio와 End-to-End Delay 측면에서 성능이 일부 개선된 것을 확인할 수 있었다.

구조물-비구조요소 2자유도 결합시스템 해석을 통한 비구조요소 내진설계변수 평가 (Evaluation of Seismic Design Parameters for Nonstructural Components Based on Coupled Structure-Nonstructural 2-DOF System Analysis)

  • 배창준;이철호;전수찬
    • 한국지진공학회논문집
    • /
    • 제26권3호
    • /
    • pp.105-116
    • /
    • 2022
  • Seismic demand on nonstructural components (NSCs) is highly dependent on the coupled behavior of a combined supporting structure-NSC system. Because of the inherent complexities of the problem, many of the affecting factors are inevitably neglected or simplified based on engineering judgments in current seismic design codes. However, a systematic analysis of the key affecting factors should establish reasonable seismic design provisions for NSCs. In this study, an idealized 2-DOF model simulating the coupled structure-NSC system was constructed to analyze the parameters that affect the response of NSCs comprehensively. The analyses were conducted to evaluate the effects of structure-NSC mass ratio, structure, and NSC nonlinearities on the peak component acceleration. Also, the appropriateness of component ductility factor (Rp) given by current codes was discussed based on the required ductility capacity of NSCs. It was observed that the responses of NSCs on the coupled system were significantly affected by the mass ratio, resulting in lower accelerations than the floor spectrum-based response, which neglected the interaction effects. Also, the component amplification factor (ap) in current provisions tended to underestimate the dynamic amplification of NSCs with a mass ratio of less than 15%. The nonlinearity of NSCs decreased the component responses. In some cases, the code-specified Rp caused nonlinear deformation far beyond the ductility capacity of NSCs, and a practically unacceptable level of ductility was required for short-period NSCs to achieve the assigned amount of response reduction.

한일간 Ro-Ro 부두 수요 및 적정 규모 추정 (Estimation of Demand for and Proper Capacity of Ro-Ro Berths in Korea-Japan Trade)

  • 김율성;이경남;강달원
    • 한국항만경제학회지
    • /
    • 제31권3호
    • /
    • pp.107-120
    • /
    • 2015
  • 기업들의 국제물류체계는 물류비용과 시간의 절감뿐만 아니라 물류의 부가가치 창출 기능을 극대화하기 위해 급속히 발전할 전망이다. 글로벌 공급체인 운영방식인 Ro-Ro 운송은 운송시간의 정확성, 비용절감, 신속성, 안전성 향상 등에서 경쟁력이 높아 이를 활용하기 위한 전략이 급증할 것으로 전망된다. 이에 본 연구에서는 한일간 교류 물동량 분석을 통해 Ro-Ro 부두 조성의 적정 수요와 규모를 추정해 보고자 하였다. 이를 위해 한일간 Ro-Ro선의 운항속도에 근거한 운항거리를 바탕으로 1권역과 2권역으로 구분하여 부산항과의 물동량(컨테이너와 일반화물)을 분석하였다. 분석된 물동량을 바탕으로 Ro-Ro선 이용 가능성이 높은 품목의 비중을 추정한 후 한일간 Ro-Ro 부두의 이용가능 물동량을 추정하였다. 추정된 물동량을 처리하기 위해서는 2만톤급 2개 선석과 장치장 10만$m^2$ 정도가 필요한 것으로 판단된다. 부산항에 Ro-Ro 전용 부두 조성을 통해 컨테이너 일변도의 항만정책을 탈피하고, 글로벌 기업들의 수요에도 대응할 수 있을 것이다.

상수도(上水道)의 1일(日) 급수량(給水量) 및 배수지(配水池) 용량(容量) 변화(變化)에 관한 연구(硏究) (The Variation of the Urban Water Use and the Distribution Reservior Capacity with Time for a Day)

  • 이경훈;박성천;문병석
    • 상하수도학회지
    • /
    • 제9권2호
    • /
    • pp.118-126
    • /
    • 1995
  • The variation of the urban water demand and the amount of water in the distribution reservoir was studied with time for a day. The city of Kwangju in Korea was selected as a study area. The population of Kwangju in the end of 1993 was more than one million and two hundred thousand peoples. The average of daily water use in 1993 was about three hundred and fifty thousand tons a day. One day was devided into 12 divisions with a 2 hour increment. The water use demand related to the amount of water in the distribution reservoir was observed for the given time interval of a day. The water use index was defind in percentage that indicates the ratio of the amount of water use for a time interval to the amount of water use for a day. The water use index with consideration of the water stored in the reservoir was found to be useful to manage and to operate the water supply systems in real time.

  • PDF

존 체계 구축이 교통수요 추정에 미치는 영향에 관한 연구 (Effects of Zoning Structure on Travel Demand Forecasts)

  • 한명주;성홍모;백승한;임용택;이영인
    • 대한교통학회지
    • /
    • 제29권1호
    • /
    • pp.17-27
    • /
    • 2011
  • 본 연구에서는 교통수요분석의 중요한 오차요인 가운데 하나인 존 체계 구축에 따른 교통수요 추정 결과의 영향을 국가교통DB 전국 지역 간 자료를 이용하여 실증적으로 살펴보고 이를 통하여 현재 배포되는 Network 수준 및 해당사업(고속도로, 국도, 국지도 및 지방도 / 차로수)에 따른 적정 존 체계 수준, 내부 통행비율 수준 등에 대한 결과를 비교분석하였다. 더불어, 존 체계 수준에 따라 교통수요 추정 결과의 정확도가 도로위계, 도로용량별로 어떻게 달라지는지를 검토하였다. 마지막으로, 국가교통DB의 전국 지역 간 자료의 적정한 존 체계 수준을 제시해 보았다. 본 연구에서는 사회경제변수를 고려한 적정 Centroid의 위치와 Connector 연결지점 및 개수 등 존 체계를 구축하였으며, 존 체계 구축이 교통수요 추정에 어떤 영향을 미치는지를 살펴보기 위해 F-test와 상관계수 분석, 평균통행거리 및 통행시간분석, 오차율 분석, 총 주행거리 분석 등을 수행하였다. 분석 결과, 도로위계, 도로용량에 따라 적정 존체계 수준이 다양하게 나타났다. 즉, 현재의 시군구 단위 존 수준에서 추가적인 존 세분화를 수행할수록 국도, 국지도 및 지방도 / 편도 1차로 도로의 교통수요 추정 결과 신뢰성이 전반적으로 개선됨을 확인할 수 있었다. 특히, 신뢰성 높은 교통수요 추정 결과를 확보하기 위해서는 되도록 읍면동 단위의 존 수준까지 존 세분화를 수행할 필요가 있음을 확인할 수 있었다.

아파트 단지를 대상으로 한 소형 열병합 발전 시스템 검토 (Study on the Small Scale CGS for APT. Complex)

  • 박화춘;박병식;정우용
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2000년도 추계 학술발표회 논문집
    • /
    • pp.221-227
    • /
    • 2000
  • 본 연구에서 대상아파트에 적용할 열병합발전 시스템의 적정 용량은 투자회수기간 및 이익발생량 등을 고려할 때 약 300kW(전기출력)급으로 나타났으며, 열병합발전 시스템의 운전 모드는 전기부하추종을 바탕으로 하여 아파트 단지의 전기수요의 기저부하를 담당하도록 하며, 아파트 단지의 전기부하가 발전기 정격용량(300kW) 이상의 범위에서는 한전전기와 계통 연계되어 운전토록 하고, 전기부하가 발전기 정격용량의 50% 부하 이상의 범위에서는 발전기만 운전하고, 전기부하가 발전기 정격용량의 50% 부하 이하에서는 발전기를 정지하고 한전전기만으로 운전하는 것이 바람직한 것으로 나타났다.

  • PDF

Rational analysis model and seismic behaviour of tall bridge piers

  • Li, Jianzhong;Guan, Zhongguo;Liang, Zhiyao
    • Structural Engineering and Mechanics
    • /
    • 제51권1호
    • /
    • pp.131-140
    • /
    • 2014
  • This study focuses on seismic behaviour of tall piers characterized by high slender ratio. Two analysis models were developed based on elastic-plastic hinged beam element and elastic-plastic fiber beam element, respectively. The effect of the division density of elastic-plastic hinged beam element on seismic demand was discussed firstly to seek a rational analysis model for tall piers. Then structural seismic behaviour such as the formation of plastic hinges, the development of plastic zone, and the displacement at the top of the tall piers were investigated through incremental dynamic analysis. It showed that the seismic behaviour of a tall pier was quite different from that of a lower pier due to higher modes contributions. In a tall pier, an additional plastic zone may occur at the middle height of the pier with the increase of seismic excitation. Moreover, the maximum curvature reaction at the bottom section and maximum lateral displacement at the top turned out to be seriously out of phase for a tall pier due to the higher modes effect, and thus pushover analysis can not appropriately predict the local displacement capacity.