• 제목/요약/키워드: degree of conversion

검색결과 351건 처리시간 0.019초

Research on the Basic Rodrigues Rotation in the Conversion of Point Clouds Coordinate System

  • Xu, Maolin;Wei, Jiaxing;Xiu, Hongling
    • Journal of Information Processing Systems
    • /
    • 제16권1호
    • /
    • pp.120-131
    • /
    • 2020
  • In order to solve the problem of point clouds coordinate conversion of non-directional scanners, this paper proposes a basic Rodrigues rotation method. Specifically, we convert the 6 degree-of-freedom (6-DOF) rotation and translation matrix into the uniaxial rotation matrix, and establish the equation of objective vector conversion based on the basic Rodrigues rotation scheme. We demonstrate the applicability of the new method by using a bar-shaped emboss point clouds as experimental input, the three-axis error and three-term error as validate indicators. The results suggest that the new method does not need linearization and is suitable for optional rotation angle. Meanwhile, the new method achieves the seamless splicing of point clouds. Furthermore, the coordinate conversion scheme proposed in this paper performs superiority by comparing with the iterative closest point (ICP) conversion method. Therefore, the basic Rodrigues rotation method is not only regarded as a suitable tool to achieve the conversion of point clouds, but also provides certain reference and guidance for similar projects.

NURBS의 차수 감소 방법을 이용한 근사변환 (Approximate conversion using the degree reduction of NURBS)

  • 김혁진
    • 한국컴퓨터정보학회논문지
    • /
    • 제8권1호
    • /
    • pp.7-12
    • /
    • 2003
  • 시스템이 지원하는 곡선 및 곡면의 최대 차수에 제한이 있을 때, 낮은 차수로의 차수 감소가 필요하다. 본 논문에서는 근사 변환의 한 방법으로써 NURBS 곡선의 차수 감소 방법을 소개한다. 이 방법은 기존 Eck의 B$\'{e}$zier 차수 감소 방법과 자료 감소를 위해 knot 제거 알고리즘이 적용된다. 제시하는 방법은 안정적일 뿐만 아니라 수학적으로도 단순하므로 이해와 구현이 용이하다.

  • PDF

The effect of 4,4'-bis(N,N-diethylamino)benzophenone on the degree of conversion in liquid photopolymer for dental 3D printing

  • Lee, Du-Hyeong;Mai, Hang Nga;Yang, Jin-Chul;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.386-391
    • /
    • 2015
  • PURPOSE. The purpose of this preliminary study was to investigate the effects of adding 4,4'-bis(N,N-diethylamino) benzophenone (DEABP) as a co-initiator to a binary photoinitiating system (camphorquinone-amine) to analyze on the degree of conversion (DC) of a light-cured resin for dental 3D printing. MATERIALS AND METHODS. Cylindrical specimens (N=60, n=30 per group, ${\phi}5mm{\times}1mm$) were fabricated using bisphenol A glycerolate dimethacrylate (BisGMA) both with and without DEABP. The freshly mixed resins were exposed to light in a custom-made closed chamber with nine light-emitting diode lamps (wavelength: 405 nm; power: $840mW/cm^2$) for polymerization at each incidence of light-irradiation at 10, 30, 60, 180, and 300 seconds, while five specimens at a time were evaluated at each given irradiation point. Fourier-transform infrared (FTIR) spectroscopy was used to measure the DC values of the resins. Two-way analysis of variance and the Duncan post hoc test were used to analyze statistically significant differences between the groups and given times (${\alpha}$=.05). RESULTS. In the DEABP-containing resin, the DC values were significantly higher at all points in time (P<.001), and also the initial polymerization velocity was faster than in the DEABP-free resin. CONCLUSION. The addition of DEABP significantly enhanced the DC values and, thus, could potentially become an efficient photoinitiator when combined with a camphorquinone-amine system and may be utilized as a more advanced photopolymerization system for dental 3D printing.

Degree of conversion of two dual-cured resin cements light-irradiated through zirconia ceramic disks

  • Kim, Min-Jeong;Kim, Kyo-Han;Kim, Young-Kyung;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권4호
    • /
    • pp.464-470
    • /
    • 2013
  • PURPOSE. The aim of this Fourier transform infrared (FTIR) spectroscopic study was to measure the degree of conversion (DC) of dual-cured resin cements light-irradiated through zirconia ceramic disks with different thicknesses using various light-curing methods. MATERIALS AND METHODS. Zirconia ceramic disks (KT12) with three different thicknesses (1.0, 2.0, and 4.0 mm) were prepared. The light transmittance of the disks was measured using ultraviolet visible near-infrared spectroscopy. Four different light-curing protocols were used by combining two curing light modes (Elipar TriLight (standard mode) and bluephase G2 (high power mode)) with light-exposure times of 40 and 120 seconds. The DCs of the two dual-cured resin cements (Duo-Link and Panavia F2.0) light-irradiated through the disks was analyzed at three time intervals (3, 7, and 10 minutes) by FTIR spectroscopy. The data was analyzed using repeated measures ANOVA (${\alpha}$=.05).Two-way ANOVA and Tukey post hoc test were used to analyze the 10 minute DC results. RESULTS. The 1.0 mm thick disk exhibited low light transmittance (<25%), and the transmittance decreased considerably with increasing disk thickness. All groups exhibited significantly higher 10 minute DC values than the 3 or 7 minute values (P<.05), but some exceptions were observed in Duo-Link. Two-way ANOVA revealed that the influence of the zirconia disk thickness on the 10 minute DC was dependent on the light-curing methods (P<.001). This finding was still valid even at 4.0 mm thickness, where substantial light attenuation took place. CONCLUSION. The curing of the dual-cured resin cements was affected significantly by the light-curing technique, even though the additional chemical polymerization mechanism worked effectively.

상아질 접착제의 용매 증발이 접착 효율에 미치는 영향 (The effect of solvent evaporation of dentin adhesive on bonding efficacy)

  • 조민우;김지연;김덕수;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.321-334
    • /
    • 2010
  • 연구목적: 본 연구는 상아질 접착제의 잔류 용매가 접착 효율에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 본 연구에서는 5세대 2단계 산부식형 접착제와 7세대 단일과정 자가부식형 접착제를 사용하였다. 상아질 접착제의 증발률과 전환률, 적용 후 용매의 공기건조 방법에 따른 미세인장결합강도를 측정하였으며 접착 계면을 FE-SEM을 이용하여 관찰하였다. 결과: 1. 시간에 따라 접착제의 증발률은 증가하나 접착제의 종류에 따라 증가 양상이 서로 달랐다. 2. 대부분 전환률은 증발률에 비례하는 경향을 나타내었다. 3. 공기건조 방법에 따라 결합강도는 대부분 under군, control군, over군 순으로 증가하는 양상을 나타내었다. 4. FE-SEM에서 아세톤을 용매로 사용하는 접착제는 공기건조 방법에 따라 droplet이나 gap이 관찰되었다. 결론: 상아질 접착제의 잔류 용매는 접착 효율에 부정적인 영향을 미치기 때문에, 상아질 접착제의 선택과 사용 시 용매의 종류와 특징에 대한 적절한 이해가 필요할 것이다.

아르곤 레이저에 의한 복합레진의 중합시 물성 변화에 관한 연구 (A STUDY OF PHYSICAL PROPERTIES OF COMPOSITE RESIN POLYMERIZATION WITH ARGON LASER)

  • 김덕;민병순;최호영;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.1-19
    • /
    • 1998
  • After polymerizing composite resin with argon laser and visible light, four test, to be concretely, measurement of compressive strength using Instron testing machine, surface microhardness using Rockwell hardness tester, quantitative analysis of residual monomer using HPLC and analysis of degree of conversion using FTIR, were accomplished. Test groups were a sort of specimen with 3mm diameter, 4mm thickness for measuring compressive strength, two sort of specimen with 7mm diameter, 2mm and 3mm thickness for measuring surface microhardness, quantitative analysing of residual monomer after curing and measuring the degree of conversion, each were divided by six groups according to the condition of light exposure. In case of argon laser, in 1.0W and 0.5W output, the exposure time for specimen were 5 sec, 10 sec respectiyely. In case of visible light, the exposure time for specimen were 20 sec, 40 sec respectively. The test were accomplished and following results were obtained. 1. Compressive strength of composite resin was the highest in the group of 1 W output, exposing for 10 sec with argon laser, followed by the group of 0.5W, exposing for 10 sec with argon laser, the group of exposing for 40 sec with visible light. But there were statistically no significant difference between these three groups(p>0.05). 2. Surface microhardness of composite resin wasn't significantly affected by light curing conditions. 3. BIS-GMA within residual monomer was least detected in the group of exposing for 40 sec. TEGDMA was least detected in the group of 1 W output, exposing for 10 sec with argon laseboth 2mm and 3mm thickness specimen. 4. The degree of conversion of all groups in the 2mm thickness specimen were more than 50%, similar to each other but in the group of 1W, exposing 10 sec with argon laser the degree of conversion was highest in the 3mm thickness specimen. 5. Argon laser could make composite resin to has similar properties with 25% lesser exposure time than visible light.

  • PDF

4종의 간접법용 복합 레진의 기계적 특성 비교 (COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN)

  • 김길수;윤태호;송광엽;안승근
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.

FTIR을 이용한 복합레진의 중합도 비교 (THE COMPARISON OF LIGHT-CURED COMPOSITE RESIN POLYMERIZATION BY FTIR)

  • 이주현;박호원
    • 대한소아치과학회지
    • /
    • 제30권2호
    • /
    • pp.245-253
    • /
    • 2003
  • 치과용 복합레진의 중합률은 레진 기질내의 이중결합의 전환도를 나타내는 것으로 이는 재료의 물리적 성질과 기계적 성질 및 생체 친화성에 영향을 미친다. 레진의 중합도가 증가하면 취성과 수축이 증가하고 중합도가 낮으면 기계적 물리적 성질이 감소한다. 따라서 본 연구에서는 광중합형 복합레진을 사용하여 플라즈마 아크 중합기 2종, 할로겐 중합기 2종, LED 중합기 2종, pulse-delay curing의 서로 다른 중합방법의 경우를 FTIR 분석법으로 복합레진의 물리적 기계적 성질 및 생체친화성에 영향을 미치는 중합률을 분석하여 다음과 같은 결과를 얻었다. 1. 광중합 복합레진의 중합률은 FTIR로 측정하였을 때 34.52-49.31%사이로 나타났으며 플라즈마 아크 중합의 경우 Flipo는 $39.96{\pm}1.22%$, CrediII는 $45.64{\pm}1.34%$로, 할로겐 중합시 XL3000은 $43.48{\pm}1.34%$, VIP의 mode 4 사용시는 $44.31{\pm}0.72%$, LED의 LUXOMAX는 $49.31{\pm}2.37%$, Elipar Freelight는 $44.51{\pm}0.62%$, pulse-delay curing시에는 $34.52{\pm}0.85%$로 나타났다. 2. 각 중합 방법별로 중합률은 LED 중합 방법을 이용한 LUXOMAX가 다른 실험군에 비하여 가장 높은 중합률을 나타냈으며 pulse-delay curing 방법이 가장 낮은 중합률을 보였다. 3. Flipo 중합기, LUXOMAX 중합기, pulse-delay curing 방법이 다른 중합기와 비교하여 통계적으로 유의한 차이를 보였다(p<0.05). 4. 각 중합방법이 동일한 군 내의 중합기기별 차이에서는 할로겐에서는 광중합기 사이에 중합률의 차이를 보이지 않았으나 플라즈마 아크에서는 CrediII가, LED에서는 LUXOMAX가 중합률이 높았다(p<0.05).

  • PDF

중합 전 열처리가 복합레진의 일부 물성에 미치는 영향 (EFFECT OF PRE-HEATING ON SOME PHYSICAL PROPERTIES OF COMPOSITE RESIN)

  • 진명욱;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제34권1호
    • /
    • pp.30-37
    • /
    • 2009
  • 본 연구의 목적은 복합레진의 광중합 전 열처리가 복합레진의 일부 물성에 미치는 영향을 평가하는 것이다. 우식이 없는 여든 개의 발거된 치아를 사용하였다. 네 가지 온도의 복합레진, 즉, 냉장 보관되어 있던 $4^{\circ}C$ 복합레진, 상온 $17^{\circ}C$의 복합레진, $Calset^{TM}$를 이용하여 $48^{\circ}C$까지 전열처리한 복합레진, 그리고 $56^{\circ}C$까지 전열처리한 복합레진을 사용하였다. 복합레진의 물성으로서 치질과의 전단결합강도, 미세경도, 그리고 이중결합 전환율을 측정하였다. 법랑질과 상아질에서 공히 $4^{\circ}C$, $17^{\circ}C$, $48^{\circ}C$, 그리고 $56^{\circ}C$의 온도 중에서 $56^{\circ}C$까지 전열처리한 복합레진이 가장 높은 전단결합강도를 보였으며, 복합레진의 온도가 높을수록 더 높은 전단결합강도를 나타내었다. 복합레진의 온도가 높을수록 더 높은 미세경도를 나타내었다. 복합레진의 온도가 높을수록 이중결합의 전환율이 더 높게 나타났다. 제한된 여건에서 행해진 본 연구의 결과를 통하여 볼 때, 냉장고 또는 실온에 보관되어 있던 복합레진을 미리 열처리하면 치질과의 전단결합강도, 복합레진의 미세경도 및 이중결합 전환율이 증가할 것으로 보인다. 따라서 임상에서 복합레진을 사용 시 복합레진의 물성을 향상시키기 위하여 레진을 미리 열처리하는 것을 추천할 수 있겠다.

B-spline에 대한 근사변환의 실험적 분석 (An Experimental Analysis of Approximate Conversions for B-splines)

  • 김혁진
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권1호
    • /
    • pp.35-44
    • /
    • 2005
  • 서로 다른 기하학적 모델링 시스템을 사용하는 곡선 및 곡면의 자료 교환에서, 시스템이 지원하는 B-spline 곡선 및 곡면의 최대 차수에 제한이 있을 때, 주어진 허용 오차 범위 내에서 낮은 차수로의 차수 감소가 필요하다 본 논문에서는 근사 변환의 한 방법인 B-spline 곡선의 차수 감소 방법을 적용한 실험적 결과를 제공한다. B-spline 곡선의 근사변환에서 기존의 $B\acute{e}zier$ 곡선의 차수감소 방법들을 차수 감소 과정에 적용하고. 그 방법들을 비교 분석한다 knot 제거 알고리즘도 자료 감소를 위하여 차수 감소과정에 적용한다

  • PDF