• 제목/요약/키워드: degree of cementation

검색결과 27건 처리시간 0.025초

유한요소법을 이용한 대퇴 골두내 무혈성 괴사증의 다양한 수술적 기법에 대한 생체역학적 분석 (A Biomechanical Analysis of Various Surgical Procedures for Osteonecrosis of the Femoral Head using a Finite Element Method)

  • 김정성;이성재;신정욱;김용식;최재봉;김양수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.374-378
    • /
    • 1997
  • Operative procedures such as core drilling with and without fibular bone grafting have been recognized as the treatment methods for osteonecrosis of femoral head(ONFH) by delaying or preventing the collapse of the femoral head. In addition, core drilling with cementation using polymethylmethacrylate (PMMA) has been proposed recently as another surgical method. However, no definite treatment modality has been found yet while operative procedures remain controversial to many clinicians In this study, a finite element method(FEM) was employed to analyze and compare various surgical procedures of ONFH to provide a biomechanical insight. This study was based upon biomechanical findings which suggest stress concentration within the femoral head may facilitate the progression of the necrosis and eventual collapse. For this purpose, five anatomically relevant hip models were constructed in three dimensions : they were (1) intact(Type I), (2) necrotic(Type II), (3) core drilled only(Type III), (4) core drilled with fibular bone graft(Type IV), and (5) core drilled with cementation(Type V). Physiologically relevant loading were simulated. Resulting stresses were calculated. Our results showed that the volumetric percentage subjected to high stress in the necrotic cancellous region was greatest in the core drilled only model(Type III), followed by the necrotic(Type II), the bone graft (Type IV), and the cemented(Type V) models. Von Mises stresses at the tip of the graft(Type IV) was found to be twice more than those of cemented core(Type V) indicating the likelihood of the implant failure. In addition, stresses within the cemented core(Type V) were more evenly distributed and relatively lower than within the fibular bone graft(Type IV). In conclusion, our biomechanical analyses have demonstrated that the bone graft method(Type IV) and the cementation method(Type V) are both superior to the core decompression method(Type III) by reducing the high stress regions within the necrotic cancellous bone. Also it was found that the core region filled with PMMA(Type V) provides far smoother transfer of physiological load without causing the concentration of malignant stresses which may lead to the failure than with the fibular bone graft(Type IV). Therefore, considering the above results along with the degree of difficulties and risk of infection involved with preparation of the fibular bone graft, the cementation method appears to be a promising surgical treatment for the early stage of osteonecrosis of the femoral head.

  • PDF

임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향 (The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses)

  • 신황규;송영균;신수연
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.125-140
    • /
    • 2011
  • 보철물을 기능적으로 평가하기 위해 임시 시멘트로 임시 합착을 한 경우 보철물 내면의 잔여 임시 시멘트는 레진 시멘트를 이용한 최종 합착에 있어서 부정적인 영향을 미칠 수 있다. 이에 본 연구는 다양한 임시 시멘트 제거 방법과 임시 시멘트의 잔여 성분이 임플란트 전용 레진 시멘트와 보철물의 유지력에 어떠한 영향을 미치는지를 알아보고자 하였다. 임플란트 지대주는 일반적인 시멘트 유지형 보철물 제작에 사용되는 높이 5.5 mm, 직경 4.5mm, 6도의 축면 경사도와 chamfer 변연을 갖는 기성품(Solid abutment, GSRAS4621, Osstem Implant Co., Busan, Korea)을 사용하였다. 40개의 주조시편을 제작하여 합착 전 70 psi하에 공기입자 분사법을 시행하였고, 10개의 시편을 임시 시멘트의 합착과정 없이 바로 최종 시멘트로 합착하여 대조군으로 설정하였으며 나머지 시편을 각 10개씩 임시 시멘트 제거를 위하여 오렌지 솔벤트를 이용한 군, 초음파 세척을 이용한 군, 공기입자 분사법을 이용한 군으로 나누었다. 임시 시멘트의 합착과 분리 후 제거과정을 거쳐 최종 시멘트로 임플란트 전용 시멘트($Premier^{(R)}$ Implant $Cement^{TM}$, Premier Co., PA, U.S.A.)를 사용하여 최종 합착을 실시하였다. 각 시편은 10분간 5 kg의 하중 하에 합착하였으며 열순환을 거쳐 만능시험기에서 분당 0.5 mm의 속도로 인장접착강도를 측정하였다. 측정이 끝난 뒤 모든 시편을 초음파 세척과 공기입자 분사법, 증기 세척의 과정을 통해 내면의 잔여 성분을 제거하였다. 완전 건조 후 비유지놀계 임시 시멘트를 사용하여 다시 임시 합착, 분리를 거친 후 동일한 실험 과정을 반복하였고 인장접착강도를 측정하여 다음의 결과를 얻었다. 오렌지 솔벤트를 사용한 군이 가장 작은 유지력을 나타냈으며 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군과 비교시 통계적으로 유의한 차이가 있었다(p<0.05). 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군 간의 비교시 통계적으로 유의한 차이가 없었다. 오렌지 솔벤트를 사용한 군은 대조군과 비교시 통계적으로 유의한 차이가 있었으며(p<0.05), 초음파 세척법을 사용한 군과 공기 입자 분사법을 사용한 군은 대조군과 비교시 통계적으로 유의한 차이가 없었다. 임시 시멘트의 유지놀 성분의 유무에 따른 비교시 통계적으로 유의한 차이가 없었다. 이상의 결과로부터 임시 시멘트 제거를 위해 오렌지 솔벤트만을 사용하는 것은 임플란트 전용 시멘트를 사용한 최종 합착시 유지력 감소의 원인이 될 수 있음을 알 수 있었으며, 임플란트 보철물 내면의 임시 시멘트를 효과적으로 제거하기 위한 방법으로 초음파 세척법, 공기 입자 분사법, 또는 이들의 복합적인 사용이 필요함을 알 수 있었다.

포스트코어의 종류와 접착방법이 미세누출에 미치는 영향 (EFFECT OF TYPE AND CEMENTATION METHOD OF POST-CORE ON MICROLEAKAGE)

  • 윤명재;이선형;양재호
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.225-233
    • /
    • 1994
  • The restorations of the severely damaged teeth by post core have been increased with the developement of endodontic procedures. But high failure rates of these procedures being reported, various restorative modifications were induced for successful treatments. Cast post-core and prefabricated post with core buildups are choice of treatment. The main causes of failure of the restorations are the fracture of post and core, root fracture, and recurrent caries due to microleakage. Recently, the acid etching technique and the use of dentin bonding agent at tooth surface to reduce the possible microleakage at the tooth-restoration interfaces were introduced. The object of this study was to measure and compare the microleakage by the types and cementation methods of post-core. For this study, forty extracted human anterior teeth were selected for specimen. After cleansing and routine endodontic procedures, anatomic crowns of each specimen were removed at the level of 2mm above the cementoenamel junction. Canals were preparated for post insertion and specimens were divided into four groups randomly. Post-cores were fabricated according to method for each group. Microleakage was measured by length of dye penetration at the tooth-restoration interfaces with measuring microscope at 50 magnification. Oneway ANOVA and t-test were performed for statistical analysis of resulting data. The following results were obtained from this study. 1. There wert significant statistical differences in degree of microleakage between each group (p<0.01). 2. Cast post-core cemented with ZPC (Group I) showed the most severe microleakage pattern$(1.5547{\pm}0.0872mm)$, and cast post-core cemented with adhesive resin cement after tooth surface treatment with dentin bonding agent (Group II) showed the least microleakage $(0.1497{\pm}0.0872mm)$. 3. Group IV revealed less dye penetrations than group III, but no statistical significance was seen between two groups.

  • PDF

Influence of modification in core building procedure on fracture strength and failure patterns of premolars restored with fiber post and composite core

  • Kim, Young-Hoi;Lee, Jong-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.37-42
    • /
    • 2012
  • PURPOSE. The influence of the modified process in the fiber-reinforced post and resin core foundation treatment on the fracture resistance and failure pattern of premolar was tested in this study. MATERIALS AND METHODS. Thirty-six human mandibular premolars were divided into 4 groups (n = 9). In group DCT, the quartz fibre post (D.T. Light-post) was cemented with resin cement (DUO-LINK) and a core foundation was formed with composite resin (LIGHT-CORE). In group DMO and DMT, resin cement (DUO-LINK) was used for post (D.T. Lightpost) cementation and core foundation; in group DMO, these procedures were performed simultaneously in one step, while DMT group was accomplished in separated two steps. In group LCT, the glass fiber post (LuxaPost) cementation and core foundation was accomplished with composite resin (LuxaCore-Dual) in separated procedures. Tooth were prepared with 2 mm ferrule and restored with nickel-chromium crowns. A static loading test was carried out and loads were applied to the buccal surface of the buccal cusp at a 45 degree inclination to the long axis of the tooth until failure occurred. The data were analyzed with MANOVA (${\alpha}$= .05). The failure pattern was observed and classified as either favorable (allowing repair) or unfavorable (not allowing repair). RESULTS. The mean fracture strength was highest in group DCT followed in descending order by groups DMO, DMT, and LCT. However, there were no significant differences in fracture strength between the groups. A higher prevalence of favorable fractures was detected in group DMT but there were no significant differences between the groups. CONCLUSION. The change of post or core foundation method does not appear to influence the fracture strength and failure patterns.

Machine learning-based regression analysis for estimating Cerchar abrasivity index

  • Kwak, No-Sang;Ko, Tae Young
    • Geomechanics and Engineering
    • /
    • 제29권3호
    • /
    • pp.219-228
    • /
    • 2022
  • The most widely used parameter to represent rock abrasiveness is the Cerchar abrasivity index (CAI). The CAI value can be applied to predict wear in TBM cutters. It has been extensively demonstrated that the CAI is affected significantly by cementation degree, strength, and amount of abrasive minerals, i.e., the quartz content or equivalent quartz content in rocks. The relationship between the properties of rocks and the CAI is investigated in this study. A database comprising 223 observations that includes rock types, uniaxial compressive strengths, Brazilian tensile strengths, equivalent quartz contents, quartz contents, brittleness indices, and CAIs is constructed. A linear model is developed by selecting independent variables while considering multicollinearity after performing multiple regression analyses. Machine learning-based regression methods including support vector regression, regression tree regression, k-nearest neighbors regression, random forest regression, and artificial neural network regression are used in addition to multiple linear regression. The results of the random forest regression model show that it yields the best prediction performance.

시멘트 유지형 임플란트 보철물의 유지력에 시멘트의 종류와 열순환이 미치는 영향에 관한 연구 (EFFECTS OF VARIOUS CEMENTS AND THERMOCYCLING ON RETENTIVE STRENGTHS OF CEMENTED IMPLANT-SUPPORTED PROSTHESES)

  • 조재호;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.466-475
    • /
    • 2003
  • Statement of problem : In cemented implant-supported porstheses, it is still controversy what kind of cement to use. However, the effect of thermocycling on retentive strength of cemented implant-supported prostheses has not been well investigated. Purpose : This study was tested to evaluate the effects of various cements and thermocycling on retentive strengths of cemented implant-supported prostheses. Material and methods : Prefabricated implant abutments, height 5mm, diameter 6mm, 3-degree taper per side, with light chamfer margins were used. Ten specimens of two-unit fred partial denture were fabricated. The luting agents used for this study were three provisional luting agents which were Temp bond, Temp bond NE, IRM and four permanent luting agents which were Panavia F, Fuji-cem, Hy-bond Zinc cement, Hy-bond Polycarboxylate cement. 24 hours after cementation. the retentive strengths were measured by the universal testing machine with a cross-head speed of 0.5mm/min. Then cementation procedures were repeated and specimens were thermocycled 1000 times at temperature of $5^{\circ}C$ and $55^{\circ}C$. After thermocycling, the retentive strengths were measured. Results : Before thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem. Hy-bond Zinc cement. Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were significant differences among each groups(p<0.05). After thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem, Hybond Zinc cement, Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were no significant differences among Panavia F, Fuji-cem and Temp bond NE, Temp bond(p>0.05). The retentive strengths before and after thermocycling showed significant differences in Hy-bond Zinc cement. IRM, Temp bond NE and Temp bond(p<0.05). Conclusion : Within the limitation of this study, thermocycling do not affect the retentive strengths of permanent luting agents but the retentive strengths of temporary cements were reduced significantly after thermocyling.

도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교 (Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR)

  • 유지성;김지환;김선재;이용근;심준성
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.416-423
    • /
    • 2009
  • 연구목적: 이번 연구의 목적은 PLV 수복물의 접착 시 사용되는 광중합형 레진 시멘트의 중합도를 Fronrier transform infrared spectroscope로 측정하여 도재의 두께, 광원 및 광조사 시간에 따른 중합도의 차이를 비교하기 위함이다. 연구재료 및 방법: 대조군으로는 1.0 mm의 투명한 slide glass를 사용하였고, 도재 시편은 IPS Empress Esthetic shade ETC1을 선택하여 0.5, 1.0, 1.5 mm의 두께로 제작하였다. 레진 시멘트는 광중합형 레진 시멘트인 Rely $X^{TM}$ Veneer Shade A3를 사용하였다. 광원으로는 Quartz Tungsten Halogen (QTH), Light Emitting Diode (LED), Plasma arc curing (PAC) 광중합기를 사용하였다. 레진 시멘트의 중합도는 FT-IR과 OMNIC 프로그램을 이용하여 측정하였다. 통계분석은 one-way ANOVA와 Tukey HSD를 이용하였다 ($\alpha$=0.05). 결과: 대조군에서 QTH와 LED로 광중합을 시행하였을 때 PAC로 광조사를 시행한 경우보다 중합도가 높았다. QTH와 LED로 광조사를 시행한 경우, 대조군과 0.5 mm, 1.0 mm, 1.5 mm의 도재 두께에서 유의차를 보이지 않았다. 반면, PAC로 광조사를 시행한 결과, 도재의 두께가 1.5 mm인 실험군의 중합도가 대조군과 0.5 mm에서 보다 통계적으로 유의하게 낮은 결과를 보인다 (P<.05). 두께가 1.0 mm의 도재와 LED 광중합기로 광조사하여 중합도를 비교한 결과, 20초간 광조사를 시행하였을 때와 비교하여 80초와 160초간 광조사를 시행한 경우 통계적으로 유의하게 중합도의 평균값이 높았다 (P<.05). 결론: 이번 연구의 한계 내에서, 도재의 두께가 0.5-1.5 mm 이내의 PLV 접착 시, PAC 중합기의 사용은 고려되지 않으며, QTH나 LED로 40초 이상 중합한다면 광중합형 레진 시멘트를 사용할 수 있다. 또한, 광중합형 레진 시멘트를 LED로 중합시킬 경우, 광조사 시간의 증가가 중합도의 증가와 비례하지 않으며, 일정시간 이상의 광조사가 중합도에 큰 영향을 끼치지 않는다.

Collarless 도재용착주조관의 치경부 도재 변연부의 적합도 및 rounding의 비교 (A STUDY ON LABIOCERVICAL MARGINAL FITNESS AND MARGINAL ROUNDING OF COLLARLESS METAL CERAMIC RESTORATION)

  • 신석훈;이호용
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.198-209
    • /
    • 1995
  • In order to evaluate the fitness and the degree of rounding of porcelain margins in collarless metal cermic restorations, collarless metal ceramic restorations were fabricated with shoulder margins of 90 and 120 degress, each consisting of ten specimens, on master dies through the direct lift technique. And ten metal ceramic restorations with a shoulder 90 degrees were fabricated. All specimens were embedded in resin and sectioned longitudinally. The sections were observed under a stereomicroscope and photographed(${\times}$200). The labial marginal gap between the die and the porcelain margin were measured with a scale. The space between the porcelain margin and the die, that is formed from marginal rounding and cementation were calculated with a computer coordinating area curvimeter. The following results were obtained. 1. There was no statistical difference between the fitness of porcelain margin of collarless metal ceramic restorations and marginal fitness of metal ceramic restoration. 2. There was no statistical difference between a shoulder of 90 and 120 degrees in the fitness of porcelain margin of collarless metal ceramic resorations. 3. Collarless metal ceramic restorations with a shoulder of 90 degrees and 120 degrees showed significantly more labial marginal rounding than metal ceramic restorations. 4. There was no statistical difference between a shoulder of 90 and 120 degrees in rounding of porcelain margin of collarless metal ceramic restorations. According to the results, rounding of porcelain margins can be observed in collarless metal ceramic restorations. Thus, there is a need for improvement in dental materials and techniques to minimize this problem, Furthermore, care should be exercised during the clinical procedure.

  • PDF

Study on mechanical properties of phosphate tailings modified clay as subgrade filler

  • Xiaoqing Zhao;Tianfeng Yang;Zhongling Zong;Teng Liang;Zeyu Shen;Jiawei Li;Gui Zhao
    • Geomechanics and Engineering
    • /
    • 제36권6호
    • /
    • pp.619-629
    • /
    • 2024
  • To improve the utilization rate of phosphate tailings (PTs) and widen the sources of subgrade filler, the PTs is employed to modify clay, forming a PTs modified clay, applied in the subgrade. Accordingly, the environmental friendliness of PTs was investigated. Subsequently, an optimal proportion was determined through compaction and California Bearing Ratio (CBR) experiments. Afterward, the stability of mixture with the optimal proportion was further evaluated through the water stability and dry-wet stability experiments. Finally, via the gradation and microstructure experiments, the strength mechanism of PTs modified clay was analyzed. The results show that the PTs were classified in the non-hazardous solid wastes, belonging to Class A building materials. With the increase of PTs content and the decrease of clay content, the optimum water content and the swelling degree gradually decrease, while the maximum dry density and CBR first increase and then decrease, reaching their peak value at 50% PTs content, which is the optimal proportion. The resilient modulus of PTs modified clay at the optimal proportion reaches 110.2 MPa. The water stability coefficient becomes stable after soaking for 4 days, while the dry-wet stability coefficient decreases with the increase of cycles and tends to be stable after 8 cycles. Under the long-term action, the dry-wet change has a greater adverse impact than continuous soaking. The analysis demonstrates that the better strength mainly comes from the skeleton role of PTs and the cementation of clay. The systematic laboratory test results and economic analysis collectively provide data evidence for the advantages of PTs modified clay as a subgrade filler.

Comparison of effect of desensitizing agents on the retention of crowns cemented with luting agents: an in vitro study

  • Jalandar, Sonune Shital;Pandharinath, Dange Shankar;Arun, Khalikar;Smita, Vaidya
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.127-133
    • /
    • 2012
  • PURPOSE. Many dentists use desensitizing agents to prevent hypersensitivity. This study compared and evaluated the effect of two desensitizing agents on the retention of cast crowns when cemented with various luting agents. MATERIALS AND METHODS. Ninety freshly extracted human molars were prepared with flat occlusal surface, 6 degree taper and approximately 4 mm axial length. The prepared specimens were divided into 3 groups and each group is further divided into 3 subgroups. Desensitizing agents used were GC Tooth Mousse and $GLUMA^{(R)}$ desensitizer. Cementing agents used were zinc phosphate, glass ionomer and resin modified glass ionomer cement. Individual crowns with loop were made from base metal alloy. Desensitizing agents were applied before cementation of crowns except for control group. Under tensional force the crowns were removed using an automated universal testing machine. Statistical analysis included one-way ANOVA followed by Turkey-Kramer post hoc test at a preset alpha of 0.05. RESULTS. Resin modified glass ionomer cement exhibited the highest retentive strength and all dentin treatments resulted in significantly different retentive values (In Kg.): GLUMA ($49.02{\pm}3.32$) > Control ($48.61{\pm}3.54$) > Tooth mousse ($48.34{\pm}2.94$). Retentive strength for glass ionomer cement were GLUMA ($41.14{\pm}2.42$) > Tooth mousse ($40.32{\pm}3.89$) > Control ($39.09{\pm}2.80$). For zinc phosphate cement the retentive strength were lowest GLUMA ($27.92{\pm}3.20$) > Control ($27.69{\pm}3.39$) > Tooth mousse ($25.27{\pm}4.60$). CONCLUSION. The use of $GLUMA^{(R)}$ desensitizer has no effect on crown retention. GC Tooth Mousse does not affect the retentive ability of glass ionomer and resin modified glass ionomer cement, but it decreases the retentive ability of zinc phosphate cement.