Experimental Study on Deflection Evaluation of KCI specification and Eurocode 2 (콘크리트 구조 설계기준과 Eurocode 2의 처짐 산정에 관한 실험적 고찰)

  • Lee, In-Ju;Kim, Tae-Wan;Oh, Seok-Mim;Kim, Jun-Won;Park, Sun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.141-144
    • /
    • 2008
  • Deflection in terms of serviceability of reinforced concrete structures is considered as one of significant factor. Domestic concrete specification offers a procedure to evaluate deflection using effective moment of inertia at cracked section, which has been known as Branson's equation in ACI. Branson's equation was derived from statistical analysis of maximum deflection of flexural members, but is somewhat weak in no reflection of bond characteristics between reinforced bars and concrete, such as tension stiffening effect. Therefore, present code creates difference from actual deflection. In this study, experiments about deflection of RC beams was completed to compare domestic standard and Eurocode 2, which calculates deflection considering tension stiffening effect. Four RC beams were built and tested, and initial modulus of elasticity and tensile strength of concrete used in the test was calculated by each design standard.

  • PDF

Bending Properties of Parallel Chord Truss with Steel-Web Members

  • Hyung Woo LEE;Sang Sik JANG
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.3
    • /
    • pp.197-206
    • /
    • 2023
  • A truss is a structure in which the members are connected and arranged such that they are primarily subjected to axial loading. A truss has the advantage that it can be used for a longer span because the structure distributes the applied force to its members well, and the load is transmitted only in the axial direction of the members. Trusses manufactured using timber have more advantages than those made of other materials. In this study, the properties of parallel chord trusses composed of timber chord and steel-web members were evaluated. We constructed truss specimens with various lengths by using upper and lower chords of 2 × 4 inch spruce-pine-fir lumber and steel-web members manufactured by S and P companies. The specimens were tested in accordance with KS F 2150. The test results showed that the load at the deflection limit and the deflection limit itself increased from L/180 to L/360 regardless of the length of the specimens. For specimens of the same length, the load at the deflection limit increased as the height of the parallel timber chord truss specimens increased from 200 to 300 mm. Successive installations of the steel-web members (SST) showed almost 2 times the load at each deflection limit compared to that of SAT specimens (alternate installation of the steel-web members). When comparing the three load-deflection limits in terms of the manufacturer of the steel-web members, the load at each deflection limit for SST specimens was higher than that for PST specimens.

An Experimental Study for the Development of Epoxy Adhesives for Optical Top (광학정반용 에폭시 접착제 개발을 위한 실험적 연구)

  • Gil, Hyeong-Gyeun;Youn, Seok-Weon;Kim, Kwang-San
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.8
    • /
    • pp.727-733
    • /
    • 2010
  • Optical tables provide a platform for the establishment and test of measurement systems which use Laser. Therefore, not only static characteristics such as surface flatness, static stiffness and etc. but dynamic response characteristics is very important design parameter. The dynamic stiffness is generally estimated through the modal test, and compliance is used as a representative performance standard. Recently there is an example of defining the dynamic deflection coefficient and using it as a new performance standard of the dynamic stiffness, but it is not generalized yet in industry. In this study, we verify the validity of existing DDC calculus by making an experiment on granite. And for improvement in damping performance of optical tables, we are going to evaluate the effect of fillers on the compliance, then develop an epoxy adhesive based on the result of this experiment.

Flexural behavior of concrete beams reinforced with aramid fiber reinforced polymer (AFRP) bars

  • Kim, Min Sook;Lee, Young Hak;Kim, Heecheul;Scanlon, Andrew;Lee, Junbok
    • Structural Engineering and Mechanics
    • /
    • v.38 no.4
    • /
    • pp.459-477
    • /
    • 2011
  • Due to the low elastic modulus of FRP, concrete members reinforced with FRP rebars show greater deflections than members reinforced with steel rebars. Deflection is one of the important factors to consider the serviceability of horizontal members. In this study flexural test of AFRP reinforced concrete beams was performed considering reinforcement ratio and compressive strength as parameters. The test results indicated that flexural capacity and stiffness increase in proportion to the reinforcement ratio. The test results were compared with existing proposed equations for the effective moment of inertia including ACI 440. The most of the proposed equations were found to over-estimate the effective moment of inertia while the equation proposed by Bischoff and Scanlon (2007) most accurately predicted the values obtained through actual testing.

Flexure Toughness of Fiber Reinforced Concrete with Ring Type Steel Fiber (원형 강섬유 보강 콘크리트의 인성)

  • Hur, Jun;Jeong, Eui-Jeong;Choi, Oan-Chul;An, Jung-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.313-318
    • /
    • 1999
  • This study is aim to evaluate of the flexure toughness of fiber reinforced concrete with ring type steel fiber. The experiment proceeding ASTM C 78 is performed to make a comparision between the ring type flber and the double-hook type fiber which is recently come in to use. The size of the test specimen is 10$\times$10$\times$35mm and the flexture test is proceeded by third-point loading method. The test lasts until 2mm deflection and the loading speed is 0.01mm/min by deflection control. From the experimental results, the specimens with ring type fiber of 30kg/㎥ and 30mm diameter of ring circle show much higher toughness indices than those of the double-hook type fiber of 30kg/㎥ and 30mm long.

  • PDF

Model Test for the Damage Assessment of Adjacent Frame Structures in Urban Excavation (지반 굴착에 따른 인접 프레임구조물의 손상평가에 관한 모형실험 연구)

  • Kim, Seong-Cheol;Hwang, Eui-Seok;Kim, Zu-Cheol;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1490-1495
    • /
    • 2005
  • In this study, Model test of concrete frame structures with various shapes and locations are carried out by means of applying Peck's(1969) settlement method. The results of the model test indicated that important correlations existed between the behavior of frame structure and ground movement. Also, the damage level of frame structure closely influenced by the phase of excavation. Therefore, prediction of damage level at early phase of construction should be very precise. The damage level graph by Cording et al.(2001), the angular distortion provided gradually more serious damage to frame structures for the all cases. But the damage level graph by Burland(1997), was difficult to confirm because of very small amount of deflection ratio.

  • PDF

Wind Tunnel Test of Smart Un-manned Aerial Vehicle(SUAV) for TR-E2 Configuration (스마트 무인기 TR-E2 형상 풍동시험 결과)

  • Yoon, Sung-Jun;Cho, Ta-Hwan;Chung, Jin-Deog
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.35-45
    • /
    • 2005
  • TR-E2 configuration designed by Bell Textron was tested in KARI 1-m wind tunnel. To explore aerodynamic characteristics for the given configuration, a $12\%$ scaled model was fabricated and tested. Wind tunnel test for TR-E2 had been performed by changing the incidence angles of wing and deflection angles of control surfaces. Test result showed that the lower wing incidence angle has more favorable lift to drag ratio compared with original design. Longitudinal and directional characteristics of TR-E2 were found to be stable for the pitch and yaw motions. However, the lateral stability of TR-E2 is not stable for certain control surface deflection.

Wind Tunnel Test of Smart Un-manned Aerial Vehicle(SUAV) for TR-E2S1 Configuration (스마트 무인기 TR-E2S1 형상 풍동시험 결과)

  • Yoon SunEiun;Cho Tahwan;Chung Jindeog
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.295-305
    • /
    • 2005
  • To improve the aerodynamic effciency of TR-E2, a new configuration so called TR-E2Sl was introduced. TR-2251 is composed of different wing airfoil section and T-tail shape compared with TR-E2. Wind tunnel test for TR-EBS1 had been performed by changing the incidence angles of wing and deflection angles of control surfaces such as elevator and rudder. Also the on/off effect of ventral fin attached underneath of AFT fuselage was tested. Test result showed that variations of wing incidence angle did not cause any severe differences in aerodynamic characteristics. Longitudinal and directional characteristics of TR-E2S1 show stable for the pitch and yaw motions. However, the lateral stability of TR-E2S1 is not stable for a certain control surface deflection.

Integer Programming Approach to the Convergence Adjustment on Color Display Tube

  • Park, Sungsoo;Kang, Donghan;Lee, Hyohyung;Hong, Cheol-Kee
    • Industrial Engineering and Management Systems
    • /
    • v.3 no.1
    • /
    • pp.63-70
    • /
    • 2004
  • In this paper, we consider the adjustment of convergence on Color Display Tube (CDT). Convergence is a measure of how well the red, green and blue beams are physically aligned with each other to strike the same area on the screen. When misconvergence (convergence error) occurs, one way of compensating it is to attach several ferrite sheets on the inner part of Deflection Yoke (DY). We suggest an optimization model of misconvergence compensation process and report test results for 81 DY samples. As a result, more than 90% of the samples could be made to satisfy the required convergence criteria.

A Study on Load Transfer Efficiency of Skewed Transverse Joint of Concrete Pavement by the Fatigue Test (피로실험에 의한 콘크리트 포장체 경사가로줄눈부의 하중전달율에 관한 연구)

  • Hwang, Seung-Eui;Bae, Ju-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.3
    • /
    • pp.203-211
    • /
    • 2001
  • This paper presents load transfer efficiency of skewed transverse joint of jointed concrete pavement with the fatigue model test. A 1/12 scale model was used to satisfy the geometry, loading, material similitude, which are variables to the skew angel of transverse joint. As the test results by fatigue load 700kgf applied, the deflection and stress of transverse joint were decreased as to increasing of skew angle of transverse joint. In addition, load transfer efficiency of transverse joint with skew angle is better than the load transfer efficiency of transverse joint without skew angle.

  • PDF