DOI QR코드

DOI QR Code

Bending Properties of Parallel Chord Truss with Steel-Web Members

  • Hyung Woo LEE (Department of Biobased Materials, College of Agriculture & Life Science, Chungnam National University) ;
  • Sang Sik JANG (Department of Biobased Materials, College of Agriculture & Life Science, Chungnam National University)
  • Received : 2022.11.11
  • Accepted : 2023.04.09
  • Published : 2023.05.25

Abstract

A truss is a structure in which the members are connected and arranged such that they are primarily subjected to axial loading. A truss has the advantage that it can be used for a longer span because the structure distributes the applied force to its members well, and the load is transmitted only in the axial direction of the members. Trusses manufactured using timber have more advantages than those made of other materials. In this study, the properties of parallel chord trusses composed of timber chord and steel-web members were evaluated. We constructed truss specimens with various lengths by using upper and lower chords of 2 × 4 inch spruce-pine-fir lumber and steel-web members manufactured by S and P companies. The specimens were tested in accordance with KS F 2150. The test results showed that the load at the deflection limit and the deflection limit itself increased from L/180 to L/360 regardless of the length of the specimens. For specimens of the same length, the load at the deflection limit increased as the height of the parallel timber chord truss specimens increased from 200 to 300 mm. Successive installations of the steel-web members (SST) showed almost 2 times the load at each deflection limit compared to that of SAT specimens (alternate installation of the steel-web members). When comparing the three load-deflection limits in terms of the manufacturer of the steel-web members, the load at each deflection limit for SST specimens was higher than that for PST specimens.

Keywords

References

  1. Afolayan, J.O. 1998. Economic efficiency of glued joints in timber truss systems. Building and Environment 34(2): 101-107. https://doi.org/10.1016/S0360-1323(98)00003-1
  2. Cha, J.K. 1992. Study on metal plate connections and plywood gusset plate connections for light-frame wood truss tension joint. Journal of the Korean Wood Science and Technology 20(1): 46-50.
  3. Choi, G.W., Yang, S.M., Lee, H.J., Kim, J.H., Choi, K.H., Kang, S.G. 2020. A study on the block shear strength according to the layer composition of and adhesive type of ply-lam CLT. Journal of the Korean Wood Science and Technology 48(6): 791-806. https://doi.org/10.5658/WOOD.2020.48.6.791
  4. Choi, G.W., Yang, S.M., Lee, H.J., Kim, J.H., Choi, K.H., Kang, S.G. 2021. Evaluation of flexural performance according to the plywood bonding method of ply-lam CLT. Journal of the Korean Wood Science and Technology 49(2): 107-121. https://doi.org/10.5658/WOOD.2021.49.2.107
  5. Fujimoto, Y., Tanaka, H., Morita, H., Kang, S.G. 2021. Development of ply-lam composed of Japanese cypress laminate and Korean larch plywood. Journal of the Korean Wood Science and Technology 49(1): 57-66. https://doi.org/10.5658/WOOD.2021.49.1.57
  6. Galih, N.M., Yang, S.M., Yu, S.M., Kang, S.G. 2020. Study on the mechanical properties of tropical hybrid cross laminated timber using bamboo laminated board as core layer. Journal of the Korean Wood Science and Technology 48(2): 245-252. https://doi.org/10.5658/WOOD.2020.48.2.245
  7. Hwang, S.W., Chung, H., Lee, T., Ahn, K.S., Pang, S.J., Bang, J., Kwak, H.W., Oh, J.K., Yeo, H. 2022. Monitoring of moisture and dimensional behaviors of nail-laminated timber (NLT)-concrete slab exposed to outdoor air. Journal of the Korean Wood Science and Technology 50(5): 301-314. https://doi.org/10.5658/WOOD.2022.50.5.301
  8. Isopescu, D., Gavriloaia, C. 2015. Determination of modal damping ratio for a hybrid floor system. Journal of Vibroengineering 17(4): 1961-1970.
  9. Jung, H., Song, Y., Hong, S. 2020. Effect of glass fiber-reinforced connection on the horizontal shear strength of CLT walls. Journal of the Korean Wood Science and Technology 48(5): 685-695. https://doi.org/10.5658/WOOD.2020.48.5.685
  10. Kim, T.W., Ha, B., Jang, S.S. 2014. The strength and applications of OSB gusset trusses for field assembly. Journal of the Korean Wood Science and Technology 42(6): 708-713. https://doi.org/10.5658/WOOD.2014.42.6.708
  11. Komatsu, K., Teng, Q., Li, Z., Zhang, X., Cai, W., Que, Z. 2018. Experimental and numerical analyses on nonlinear behaviour of wooden parallel chord trusses composed of self-tapping screws. Journal of Wood Science 64(6): 776-793. https://doi.org/10.1007/s10086-018-1774-0
  12. Korea Standard Association. 2020. Method of Static Bending Test for Full Sized Structural Lumber. KS F 2150. Korea Standard Association, Seoul, Korea.
  13. Lee, H.W., Jang, S.S. 2023. Lateral resistance of reinforced light-frame wood shear walls. Journal of the Korean Wood Science and Technology 51(1): 58-66. https://doi.org/10.5658/WOOD.2023.51.1.58
  14. Lennon, T., Hopkin, D., EI-Rimawi, J., Silberschmidt, V. 2010. Large scale natural fire tests on protected engineered timber floor systems. Fire Safety Journal 45(3): 168-182. https://doi.org/10.1016/j.firesaf.2010.02.006
  15. Ministry of Land, Infrastructure and Transport. 2022a. Standard Wood Structure for Member Design. KDS 41 50 20. Ministry of Land, Infrastructure and Transport, Sejong, Korea.
  16. Ministry of Land, Infrastructure and Transport. 2022b. Standard Wood Structure for Light Frame Timber Structure. KDS 41 50 70. Ministry of Land, Infrastructure and Transport, Sejong, Korea.
  17. Park, H.M., Gong, D.M., Shin, M.G., Byeon, H.S. 2020a. Bending creep properties of cross-laminated wood panels made with tropical hardwood and domestic temperate wood. Journal of the Korean Wood Science and Technology 48(5): 608-617. https://doi.org/10.5658/WOOD.2020.48.5.608
  18. Park, J., Song, Y., Hong, S. 2020b. Bending creep of glulam and bolted glulam under changing relative humidity. Journal of the Korean Wood Science and Technology 48(5): 676-684. https://doi.org/10.5658/WOOD.2020.48.5.676
  19. Silih, S., Premrov, M., Kravanja, S. 2005. Optimum design of plane timber trusses considering joint flexibility. Engineering Structures 27(1): 145-154. https://doi.org/10.1016/j.engstruct.2004.10.001
  20. Yang, S.M., Lee. H.H., Kang. S.G. 2021. Research trends in hybrid cross-laminated timber (CLT) to enhance the rolling shear strength of CLT. Journal of the Korean Wood Science and Technology 49(4): 336-359. https://doi.org/10.5658/WOOD.2021.49.4.336