• Title/Summary/Keyword: deep donor

Search Result 105, Processing Time 0.032 seconds

Effect of the Deep Donor Level on the Interface Electron Density ($Al_xGa_{1-x}As$-GaAs 이종접합에서 deep donor level 이 interface electron density에 미치는 영향)

  • Nam, Seaung-Hyun;Jung, Hak-Kee;Lee, Moon-Key;Kim, Bong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.465-468
    • /
    • 1987
  • This paper describes a model to calculate the equilibrium electron density of MODFET at the interface that takes into account the simultaneous shallow and deep level in the Al-GaAs layer. In the present study we have made an investigation of the interface electron density with different values of the AlGaAs doping density and spacer layer thickness, considering simultaneously two doner levels. In this case, the ratio of the shallow to the deep donor concentraction is considered. From the comparison with early experimental results we could find the deep level and that the deep donor concentration is about 50% with the Al mole fraction X ${\sim}0.3$, activation energy Edx=65meV, temperature $77^{\circ}K$ and spacer thickness range $50A{\sim}100A$. Also we have investigated the effect of the temperature. As temperature increase, at critical mole fraction X the nature of the donor concentration changes from $\Gamma$ to L and X.

  • PDF

Properties of Deep Eutectic Solvents (DESs) and Their Applications (깊은 공융 용매 (DESs) 물성과 응용)

  • Seo, Ho Seong;Park, Byung Heung
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.2
    • /
    • pp.43-48
    • /
    • 2015
  • Deep eutectic solvents (DESs) are now broadly understood as a new kind of ionic liquid (IL) because they exhibit many characteristics and properties similar with ILs. The DESs made of quaternary ammonium salt blended with one of hydrogen bonding donor (HBD) compounds behave as ILs even at very low temperature. In this study, properties such as density, viscosity, surface tension, conductivity, and electrochemical behavior of DESs were reported and their applications were reviewed. Study on DESs has been drawn attention on application in metal finishing, but these solvents can be used in a variety of synthesis, and their potentials have been demonstrated in various areas. DESs are expected to offer applicability by extending the types of salts and hydrogen bond donor mixtures.

The critical Mg doping on the blue light emission in p-type GaN thin films grown by metal-organic chemical vapor deposition

  • Kim, Keun-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.52-59
    • /
    • 2001
  • The photoluminescence and the photo-current from p-type GaN films were investigated on both room- and low-temperatures for various Mg doping concentrations. At a low Mg doping level, there exists a photoluminescence center of the donor and the acceptor pair transition of the 3.28-eV band. This center is correlated with the defects for a shallow donor of the VGa and for an acceptor of MgGa. The acceptor level shows the binding energy of 0.2-0.25 eV, which was observed by the photon energy of the photo-current signal of 3.02-3.31 eV. At a high Mg doping level, there is a photoluminescence center of a deep donor and an acceptor pair transition of the 2.76-eV blue band. This center is attributed to the defect structures of MgGa-VN for the deep donor and MgGa for the acceptor. For low. doped samples, thermal annealing provides an additional photo-current signal for an unoccupied deep acceptor levels of 0.87-1.35 eV above valence band, indicating the p-type activation.

  • PDF

Comparing Seroma Formation at the Deep Inferior Epigastric Perforator, Transverse Musculocutaneous Gracilis, and Superior Gluteal Artery Perforator Flap Donor Sites after Microsurgical Breast Reconstruction

  • Merchant, Alisha;Speck, Nicole E.;Michalak, Michal;Schaefer, Dirk J.;Farhadi, Jian
    • Archives of Plastic Surgery
    • /
    • v.49 no.4
    • /
    • pp.494-500
    • /
    • 2022
  • Background Seroma formation is the most common donor site complication following autologous breast reconstruction, along with hematoma. Seroma may lead to patient discomfort and may prolong hospital stay or delay adjuvant treatment. The aim of this study was to compare seroma rates between the deep inferior epigastric perforator (DIEP), transverse musculocutaneous gracilis (TMG), and superior gluteal artery perforator (SGAP) donor sites. Methods The authors conducted a retrospective single-center cohort study consisting of chart review of all patients who underwent microsurgical breast reconstruction from April 2018 to June 2020. The primary outcome studied was frequency of seroma formation at the different donor sites. The secondary outcome evaluated potential prognostic properties associated with seroma formation. Third, the number of donor site seroma evacuations was compared between the three donor sites. Results Overall, 242 breast reconstructions were performed in 189 patients. Demographic data were found statistically comparable between the three flap cohorts, except for body mass index (BMI). Frequency of seroma formation was highest at the SGAP donor site (75.0%), followed by the TMG (65.0%), and DIEP (28.6%) donor sites. No association was found between seroma formation and BMI, age at surgery, smoking status, diabetes mellitus, neoadjuvant chemotherapy, or DIEP laterality. The mean number of seroma evacuations was significantly higher in the SGAP and the TMG group compared with the DIEP group. Conclusion This study provides a single center's experience regarding seroma formation at the donor site after microsurgical breast reconstruction. The observed rate of donor site seroma formation was comparably high, especially in the TMG and SGAP group, necessitating an adaption of the surgical protocol.

ESTHETIC RECONSTRUCTION OF ILIAC CREST DONOR DEFECT WITH TWO TITANIUM PLATES AFTER HARVESTING A DCIA COMPOSITE FREE FLAP (장골의 복합유리피판 이식 후 두 개의 타이타늄 금속판을 이용한 공여부의 심미적 재건)

  • Kim, Soung-Min;In, Yeon-Soo;Kim, Ji-Hyuck;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.586-589
    • /
    • 2006
  • Deep circumflex iliac artery (DCIA) flap can be harvested as a composite free flap and is often used to adequately reconstruct wide mandibular defects. However, the harvesting of this DCIA flap can result in severe osseous defect of the donor site causing a morphologic defect in the iliac crest. To reconstruct this defect of the iliac donor site, several innovative techniques using bioactive ceramic spacers, autogenous rib bone, polylactic acid mesh, or titanium plates have been introduced. Nonetheless, these methods have not been widely used due to high cost, secondary donor site morbidity, difficulty of use, and postoperative dissatisfaction. We used two titanium plates to reconstruct the donor iliac site defect at the harvesting time of primary DCIA flap surgery in the 30-year old female with an ameloblastoma in the left mandible. Postoperatively, both iliac sites were relatively balanced and there were few complications. At the 2 years follow-up, there were no specific abnormal radiographic findings and the patient was very satisfied with her esthetic iliac contouring. In our report, we evaluate the effect of two titanium plates on the reconstruction of the iliac donor site in the aspects of esthetics and usefulness. This technique has many advantages, such as reduced cost, simplicity, decreased postoperative pain or discomfort, and improved bilateral balance of both anterior iliac crest contours, especially in young female patients.

Dielectric Properties and a Equivalent Circuit of ZnO-Based Varistor (ZnO 바리스터의 유전특성과 등기회로)

  • Rho, Il-Soo;Kang, Dae-Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2166-2172
    • /
    • 2007
  • In this study a low-signal equivalent circuit based on the Double Schottky Barrier model is proposed for ZnO-based varistor. Since pin-lead inductance and stray capacitance are considered in pin-lead type ZnO varistor these inductance and capacitance could be removed from the experimental dielectric data of the varistor. According to the equivalent circuit simulation results the higher the varistor-voltage of varistor sample the capacitance of dielectric layer is larger, and the capacitances of semiconducting layer and depletion layer are smaller, while the parallel resistances of semiconducting layer and depletion layer are more larger values. Spectra of the dielectric loss factor $tan{\delta}$ show 2 peaks in low frequency and high frequency regions respectively. The low-frequency peak is due to the relaxation by deep donors and the high-frequency peak is due to the relaxation by shallow donors. Above results are well consistent with the theoretical mechanism of ZnO varistor.

Synthesis and Characterization of 1,2,4-Oxadiazole-Based Deep-Blue and Blue Color Emitting Polymers

  • Agneeswari, Rajalingam;Tamilavan, Vellaiappillai;Hyun, Myung Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.513-517
    • /
    • 2014
  • Two donor-acceptor-donor monomers such as 3,5-bis(4-bromophenyl)-1,2,4-oxadiazole (BOB) and 3,5-bis(5-bromothiophen-2-yl)-1,2,4-oxadiazole (TOT) incorporating electron transporting and hole blocking 1,2,4-oxadiazloe moiety were copolymerized with light emitting fluorene derivative via Suzuki polycondensation to afford two new polymers, PFBOB and PFTOT, respectively. The optical studies for polymers PFBOB and PFTOT revealed that the band gaps are 3.10 eV and 2.72 eV, respectively, and polymer PFBOB exhibited a deep-blue emission while polymer PFTOT showed blue emission in chloroform and as thin film. The photoluminescence quantum efficiencies (${\Phi}_f$) of polymers PFBOB and PFTOT in chloroform calculated against highly blue emitting 9,10-diphenylanthracene (DPA, ${\Phi}_f=0.90$) were 1.00 and 0.44, respectively.

Immediate Breast Reconstruction with Deep Inferior Epigastric Perforator Free Flap (심부하복벽천공지 유리피판을 이용한 즉시 유방 재건술)

  • Ryu, Min Hee;Kim, Hyo Heon;Jeong, Jae Ho
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.229-236
    • /
    • 2007
  • Purpose: Breast reconstruction with deep inferior epigastric perforator(DIEP) free flap is known to be the most advanced method of utilizing autologous tissue. The DIEP free flap method saves most of the rectus abdominis muscle as well as anterior rectus sheath. Therefore, the morbidity of the donor site is minimized and the risk of hernia is markedly decreased. Methods: We chose the internal mammary artery and its venae comitantes as recipient vessels, and deep inferior epigastric vessels as donor vessels. The number and location of the perforators derived from medial or lateral branch of deep inferior epigastric artery(DIEA) in 23 DIEP flaps were identified. Ten patients underwent evaluation of their abdominal wall function preoperatively and 6 months postoperatively by using Lacote's muscle grading system. Results: Of the 23 patients, a patient with one perforator from lateral branch of DIEA experienced partial necrosis of flap. Total flap loss occurred in one patient. Mild abdominal bulging was reported in one patient 4 months postoperatively probably because of early vigorous rehabilitational therapy for her frozen shoulder. Postoperative abdominal wall function tests in 10 patients showed almost complete recovery of muscle function upto their preoperative level of upper and lower rectus abdominis and external oblique muscle function at 6 months postoperatively. All patients have been able to resume their daily activities. Conclusion: The breast reconstruction with DIEP free flap is reliable and valuable method which provide ample soft tissue from abdomen without compromising the integrity of abdominal wall. Selection of reliable perforators is important and including more than two perforators may decrease fat necrosis and partial necrosis of flap.

Topography of Deep Inferior Epigastric Perforator Flap (심부하복벽천공지의 국소해부학적 고찰)

  • Kim, Chang-Yeon;Oh, Jung-Keun;Hwang, Weon-Jung;Kim, Jeong-Tae;Ahn, Hee-Chang
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.2
    • /
    • pp.141-145
    • /
    • 2002
  • Rectus abdominis muscle free flap is widely used for breast reconstruction and soft tissue defect in lower leg but donor-site morbidities such as abdominal wall weakness, hernia, bulging are troublesome. Recently, to minimize donor-site morbidity, there has been a surge in interest in deep inferior epigastric perforator(DIEP) free flap preserving the anatomy of rectus abdominis muscle, fascia, and motor nerve. Between August of 1995 and September of 2002, topographic investigation of DIEP was performed during the elevation of 97 cases of TRAM free flap and 5 cases of DIEP free flap. There were 84 cases of breast reconstructions, 12 cases of lower leg reconstructions, and 6 cases of head and neck reconstruction. We could observe total 10 to 12 perforators on each rectus abdominis muscle below umbilicus. Among these, the numbers of large perforators(>1.5mm of diameter) were mean 2.1 in lateral half of rectus abdominis muscle, mean 1.2 in medial half, and mean 0.5 in linea alba and paramedian. DIEP free flap provides ample amount of well vascularized soft tissue without inclusion of any rectus abdominis muscle and fascia and minimizes donor-site morbidity. One perforator with significant flow can perfuse the whole flap. For large flap, a perforator of the medial row provides better perfusion to zone-4 than one of lateral row and, if diameter of perforator is small, $2{\sim}3$ perforators can be used. According to the condition of recipient-site, thin flap can be harvested. As DIEP free flap has many advantage, perforator topography will be useful in increasing clinical usage of DIEP free flap.

  • PDF

Factors Affecting Nucleation and Growth of Chromium Electrodeposited from Cr3+ Electrolytes Based on Deep Eutectic Solvents

  • El-Hallag, Ibrahim S.;Moharram, Youssef I.;Darweesh, Mona A.;Tartour, Ahmed R.
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.291-309
    • /
    • 2020
  • Chromium was electrodeposited from deep eutectic solvents-based Cr3+ electrolytes on HB-pencil graphite electrode. Factors influencing the electrochemical behavior and the processes of Cr nucleation and growth were explored using cyclic voltammetry and chronoamperometry techniques, respectively. Cr3+ reduction was found to occur through an irreversible diffusion-controlled step followed by another irreversible one of impure diffusional behaviour. The reduction behavior was found to be greatly affected by Cr3+ concentration, temperature, and type of hydrogen bond donor used in deep eutectic solvents (DESs) preparation. A more comprehensive model was suggested and successfully applied to extract a consistent data relevant to Cr nucleation kinetics from the experimental current density transients. The potential, the temperature, and the hydrogen bond donor type were estimated to be critical factors controlling Cr nucleation. The nucleation and growth processes of Cr from either choline chloride/ethylene glycol (EG-DES) or choline chloride/urea (U-DES) deep eutectic solvents were evaluated at 70℃ to be three-dimensional (3D) instantaneous and diffusion-controlled, respectively. However, the kinetics of Cr nucleation from EG-DES was found to be faster than that from U-DES. Cr nucleation was tending to be instantaneous at higher temperature, potential, and Cr3+ concentration. Cr nuclei electrodeposited from EG-DES were characterized at different conditions using scanning electron microscope (SEM). SEM images show that high number density of fine spherical nuclei of almost same sizes was nearly obtained at higher temperature and more negative potential. Energy dispersive spectroscopy (EDS) analysis confirms that Cr deposits were obtained.