• Title/Summary/Keyword: dctA

Search Result 846, Processing Time 0.022 seconds

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Image Steganography and Its Discrimination (영상 스테가노그래피의 개념과 판별)

  • Lee, Jae Hoon;Kim, Chanran;Lee, Sang Hwa;Park, Jong-Il
    • Journal of Broadcast Engineering
    • /
    • v.23 no.4
    • /
    • pp.462-473
    • /
    • 2018
  • Steganography is to hide information in a media data so naturally that the other users can not notice the existence of hidden information. Data encryption focuses on the complex encoding methods of information data in order to make it difficult to decode the information even though the other users notice the existence of information. On the other hand, steganography methods concentrate on natural hiding information into other media. Since the other users do not recognize the existence of hidden information, the information can be better protected. This paper introduces the concept of image steganography that an image information is concealed into another image (cover image), and proposes a new discrimination method of steganography. This paper explains the spatial methods with LSB manipulation and frequency methods using DCT coefficients. Finally, this paper proposes a new discrimination method of image steganography by inspecting that an image information is correctly decoded.

Enhanced Coding Method by Remapping of Integral Images (집적 영상 재배치를 통한 부호화효율 향상 방법)

  • Kim, Su-Bin;Kang, Hyun-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.2
    • /
    • pp.1-10
    • /
    • 2015
  • In this paper, we propose an integral image compression method to improve the coding efficiency. As the characteristics of integral images are various according to the distance between a camera and objects, complexity of the objects and background, etc, the coding efficiency can be improved by applying a coding method adaptive to the characteristics. In addition, as the integral images are compressed by the unit of elemental images, the coding efficiency can be improved. by employing a coding method optimized to the coding direction of elemental images. Therefore, the proposed method remaps an integral image with six kinds of mapping rules, and then the conventional 3D-DCT based compression method is applied to the remapped images. Finally, we perform the rate-distortion optimization to choose the best of the mapping rules. Experimental results show that the proposed method yields high gains in image quality and bit-rate.

DCT-based Digital Dropout Detection using SVM (SVM을 이용한 DCT 기반의 디지털 드롭아웃 검출)

  • Song, Gihun;Ryu, Byungyong;Kim, Jaemyun;Ahn, Kiok;Chae, Oksam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.190-200
    • /
    • 2014
  • The video-based system of the broadcasters and the video-related institutions have shifted from analogical to digital in worldwide. This migration process can generate a defect, digital dropout, in the quality of the contents. Moreover, there are limited researches focused on these kind of defects and those related have limitations. For that reason, we are proposing a new method for feature extraction emphasizing in the peculiar block pattern of digital dropout based on discrete cosine transform (DCT). For classification of error block, we utilize support vector machine (SVM) which can manage feature vectors efficiently. Further, the proposed method overcome the limitation of the previous one using continuity of frame by frame. It is using only the information of a single frame and works better even in the presence of fast moving objects, without the necessity of specific model or parameter estimation. Therefore, this approach is capable of detecting digital dropout only with minimal complexity.

Error-Resilience Enhancement based on Polyphase Down Sampling for the H.264 Video Coding Technology (에러 강인성 향상을 위한 다상 다운 샘플링 적용 H.264 동영상 부호화 기술)

  • Jung, Eun Ku;Jia, Jie;Kim, Hae Kwang;Choi, Hae Chul;Kim, Jae Gon
    • Journal of Broadcast Engineering
    • /
    • v.10 no.3
    • /
    • pp.340-347
    • /
    • 2005
  • This paper presents a polyphase down sampling based multiple description coding applied to H.264 video coding standard. For a given macroblock, a residual macroblock is calculated by motion estimation, and before applying DCT, quantization and entrophy coding of the H.264 coding process, the polyphase down sampling is applied to the residual macroblock to code in four separate descriptions. Experiments were performed for all the 9 test sequences of JVT SVC standardization in various packet loss patterns. Experimental results show that the proposed one gives 0.5 to 5 dB enhancement over an error-concealment based on the slice group map technolgoy.

A Rotation Resistant Logo Embedding Watermark on Frequency Domain (회전 변환에 강인한 주파수 영역 로고 삽입 워터마크 방법)

  • Lee, In-Jung;Lee, Hyoung;Min, Joon-Young
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2006.06a
    • /
    • pp.730-736
    • /
    • 2006
  • In this paper, we propose a rotation resistant robust logo embedding watermarking technique. Geometric manipulations make the detection process very complex and difficult. Watermark embedding ill the normalized image directly suffers from smoothing effect due to the interpolation during the image normalization. This can be avoided by estimating the transform parameters using image normalization technique, instead of embedding in the normalized image. Conventional rotation resistant schemes that use full frame transform. In this paper, we adopt $8{\times}8$ block DCT and calculate masking using a spatio-frequency localization of the $8{\times}8$ block DCT coefficients. Experimental results show that the proposed algorithm is robust against rotation process.

  • PDF

Video Indexing and Retrieval of MPEG Video using Motion and DCT Coefficients in Compressed Domain (움직임과 DCT 계수를 이용한 압축영역에서 MPEG 비디오의 인덱싱과 검색)

  • 박한엽;최연성;김무영;강진석;장경훈;송왕철;김장형
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.2
    • /
    • pp.121-132
    • /
    • 2000
  • Most of video indexing applications depend on fast and efficient archiving, browsing, retrieval techniques. A number of techniques have been approached about only pixel domain analysis until now. Those approaches brought about the costly overhead of decompressing because the most of multimedia data is typically stored in compressed format. But with a compressed video data, if we can analyze the compressed data directly. then we avoid the costly overhead such as in pixel domain. In this paper, we analyze the information of compressed video stream directly, and then extract the available features for video indexing. We have derived the technique for cut detection using these features, and the stream is divided into shots. Also we propose a new brief key frame selection technique and an efficient video indexing method using the spatial informations(DT coefficients) and also the temporal informations(motion vectors).

  • PDF

A Steganalysis using Blockiness in JPEG images (블록 왜곡도를 이용한 JPEG 기반의 심층암호분석)

  • 장정아;유정재;이상진
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.14 no.4
    • /
    • pp.39-47
    • /
    • 2004
  • In general, the steganographic algorithm for embedding message in JPEG images, such as Jsteg$^{(1)}$ , JP Hide & Seek$^{(2)}$ , F5$^{(3)}$ , outGuess$^{(4)}$ replaces the LSB of DCT coefficients by the message bits. Both Jsteg and n Hide & seek are detected by $\chi$$^2$- test, steganalytic technique$^{(4)}$ , the rate of detection is very low, though. In this Paper, we Propose a new steganalysis method that determine not only the existence of hidden messages in JPEG images exactly, but also the steganographic algorithm used. This method is advanced from the technique Blockiness$^{(5)}$ . It has many advantages that include a computational efficiency, correctness and that can detect without bowing steganographic algorithm. Experiment results show the superiority of our approach over Blockiness$^{(5)}$ .