• Title/Summary/Keyword: daylight conditions

Search Result 110, Processing Time 0.026 seconds

An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program (베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로)

  • Lim, Tae Sub;Park, Jong Myung;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

Astronomical Phenomenon Records from Sukjong's Chunbang-Ilgi

  • Ki-Won Lee
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.1
    • /
    • pp.75-89
    • /
    • 2023
  • We investigate the astronomical phenomenon records of Sukjong's Chunbang-Ilgi made by Sigangwon (Royal Educational Office of the Crown Prince) at which King Sukjong was the crown prince (i.e., 1667 January 24-1674 September 22). From the daily records of 2,799 days, we extract the astronomical records of 1,443 days and classify them into 14 categories. Then, we group the records of each category into five phenomena (Atmosphere, Eclipse, Daylight Appearance, Apparition, and Appulse) and compare them with the results of modern astronomical computations wherever possible. Except for Atmosphere group comprising records of meteorological events, such as solar halo, lunar halo, and unusual clouds, the significant findings in every other group are as follows: In Eclipse group, the solar eclipse that occurred on 1673 August 12 was unobservable in Korea, which is in contrast to the record of Joseonwangjo-Sillok (Annals of the Joseon Dynasty), which states that the sun was in eclipse around sunset time, as observed at Nam mountain. From the lunar eclipse records, we verify that the Joseon court did not change the date of the events observed after midnight. In Daylight Appearance group, we confirm that this phenomenon was observed during the daytime and not during twilight. We further suggest that if observation conditions are met, a celestial body brighter than -2.3 mag could be seen during the daytime with the naked-eye. In Apparition group, we find the possibilities that the Orionid meteor shower had influence on the meteor records and the seasonality on the aurora records. We also find that the Korean records in which the coma of comet C/1668 E1 was located below the horizon were overlooked in previous studies. Finally, we find that the records of Appulse group generally agree with the results of modern calculations. The records of Beom (trespass in literal) and Sik (eating in literal) events show average angular separations of 1.2° and 1.0°, respectively. In conclusion, we believe this work helps study the astronomical records of other logs of Sigangwon, such as Sukjong's Chunbang-Ilgi.

A Study for Degradation Mechanism of Plastic Materials (플라스틱 소재의 탈변색 열화 메커니즘 분석)

  • Youn, Hyung-Joon;Jung, Won-Wook;Byun, Doo-Jin;Choi, Gi-Dae
    • Journal of Applied Reliability
    • /
    • v.7 no.4
    • /
    • pp.173-181
    • /
    • 2007
  • Out door exposure to daylight and weather climate conditions can cause adverse effect on the properties of automotive plastic materials. The effects of sunlight exposure, especially ultra violet (UV) radiation, can break down the chemical bonds in a polymeric material. This degradation process is called photo-degradation and ultimately leads to color changes, cracking, chalking, the loss of physical properties and deterioration of other properties. To explore the effect of sunlight exposure on the automotive materials, this study investigated photo-oxidation degree and surface property change of molding parts by analytical methods. For the further study, accelerated weathering test methods are proposed, which can correlate with out door weathering, to predict long term performance of automotive plastic materials.

  • PDF

A Comparative Evaluation of Daylighting Performance Software : Lumen-Micro, Adeline and Lightscape (채광성능 평가용 시뮬레이션 프로그램의 비교분석)

  • Kim, J.T.;Chung, Y.G.;Moon, G.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.48-56
    • /
    • 2003
  • Three of the leading computer daylighting simulation programs are compared with physical modeling techniques as a means of predicting daylighting performance of interior spaces. Lumen-Micro, Adeline and Lightscape are compared with physical model experiments under clear sky conditions. The comparative evaluations are conducted on analysis of daylight illuminance ratio(%) depending on model types. The estimated average errors are analyzed on 9.4% in Lumen-Micro, 6.3% in Adeline and 3.4% in Lightscape. Therefore, it is proved that three programs are useful for evaluating daylighting performance in our clear sky condition.

Daylighting of Underground Parking Lots in Apartment Housings by Field Survey and Performance Evaluation (공동주택 지하주차장의 자연채광 실태 및 채광성능 평가)

  • Chung, Yu-Gun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.2 no.2
    • /
    • pp.39-44
    • /
    • 2002
  • Recently, underground spaces can be usually applied to the alternative of land use for parking. However, lack of window and natural light are among the most cited drawbacks associated with dark image of underground. If underground parking lots are designed to be positive and safe environment for people, openings for daylighting will play a significant role. The natural light and unobstructed view to outdoor are main elements to create optimal underground parking lots. This paper focuses on investigating the actual day lighting conditions and evaluating the day lighting performance of openings as potential lighting resources. For the study, the field measurements and Questionnaire surveys are conducted. And then, the day lighting performance of underground parking lots based on opening geometry and orientation are evaluated by scaled model experiments. As results, the feelings of safety and orientation of underground parking lots are improved by openings for day lighting regardless of the sizes. The required illuminances (daylight factor 0.5%) for underground parking lots can be satisfied in the skylight opening ratio of 4% or more.

A Study on Planning Conditions to Improve Openness assessment in Atrium (아트리움 건축의 개방감을 상승시키는 계획조건에 관한 연구)

  • Lee, Ji-Young;Lim, Jae-Han;Jung, Jin-Ju
    • KIEAE Journal
    • /
    • v.8 no.2
    • /
    • pp.41-46
    • /
    • 2008
  • Owing to a space covered by glass, atrium is an attractive space with a possibility as an inner public space but a typical building type with a high-energy load. From the aspect of global environmental issues, to reduce energy load is an important assignment to solve. Contriving a planning guideline of an opening is considered as the most effective environment adjustment method, to offer a highly assessed amenity space and secure openness to outside, keep the energy load to a minimum, and apply the natural energy such as daylight to a maximum at the same time. Users' assessment of environment was performed by questionnaire survey, then the structure of users' assessment was analyzed and design condition was regulated by multiple regression analysis. The opening design guideline to offer a highly assessed space was proposed with concrete environment adjustment method.

Studies on the Infection Mechanism and Inhibition of Multiplication in Plant Virus Diseases(I) (식물 바이러스병의 감염기구 및 증식억제에 관한 연구 1)

  • 이정호;오정행;박찬걸;권신한
    • Korean Journal of Microbiology
    • /
    • v.12 no.2
    • /
    • pp.53-58
    • /
    • 1974
  • A number of antibiotics and organic compounds were tested for their effect on the multoplication of tobacco mosaic virus(TMV) in floating leaf discs. 1)Among six antibiotics tested, kanamycin sulfate showed 24% or more inhibition to TMV multiplication under these experimental conditions. Aureomycin hydrochloride and chloramphenicol showed 19% and 14% inhibition respectively. 2)For screening of organic compounds two environments were used, a diffuse day- light environment (25 foot-candles and laboratory temperature) and an artificial light environment for 12 hours per day(300 foot-candles at 4 to $5^{\circ}C above laboratory temperature). A wide range of organic compounds increased virus multoplication in the diffuse daylight environment but had less effect, or ingibited virus multiplication, in the artificial light environment. 3)The following compounds were among the most effective in increasing TMV multiplication: glucose-1-phosphate, L-aspartic acid, glucose, and 5-bromouracil. The following compoumds were most effective in inhibiting TMT multiplication: thiouracil, uracil, DL-isoleucine, L-leucine, and zinc chloride.

  • PDF

The Summer Cooling and Lighting Energy Performance Evaluation of Small Office Buildings with Venetian Blinds (블라인드를 고려한 여름철 소규모 사무소 건물의 냉방 및 조명에너지 평가)

  • Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 2013
  • The daylighting control system has to be applied to prevent the excessive incident daylight and reduce energy use. As the one of the most useful daylighting control systems, the blind system is simple and easy to install on the window for small office buildings. This study aims to evaluate the summer energy performance of small office buildings by venetian blinds and energy saving strategy of ministry of knowledge economy in korea. For the study, the simulations have been executed on blind installation conditions and lighting control methods. As results, the energy loads cut down 22 to 25(%) by using blind energy. Also, the efficient shows high on EMS system and low on $45^{\circ}$ slat angles. Also, using energy saving strategy can reduce about 13(%) energy load.

Daylighting Performance Evaluation of Lightshelf Window System by Lightscape (Lightscape를 이용한 광선반 창호시스템의 채광성능평가)

  • Moon, Ki Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.45-52
    • /
    • 2004
  • Simulation of daylighting by computer program is a method to avoid unnecessary efforts in manufacture of its testing models, to reduce its measuring tolerances and be able to provide variations of various weather conditions as well. Many simulation programs on daylighting have been released freely or commercialized for selling, however, a demonstration of their availability and validity as a tool for evaluating daylighting performance is required since each one has its own characteristics. The objectives of this study lie in suggesting an application method of evaluation tools and demonstration of limits and characteristics so as to more easily determine the daylightingperformance in the very initial stages of planning for an arbitrary office space in which windows with daylight access are built. We produced scale model of the general light inducing type side lighting with lightshelfand ceiling, and the luminance (at 78 measuring points) and illuminance (at 84 measuring points) were measured in a clear sky. And a comparison of the measured values and the calculated values from a computer simulation using the Lightscape program was performed.

A Experimental Study on Artificial Illumination Control System Illuminated by Daylighting (자연채광을 이용한 인공조명의 제어방법에 관한 실험적 연구)

  • 차광석;김회서
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 1994
  • It is very important and necessary to predict luminous enviroment in an interior space. This paper has described about energy saving and evaluated interior visual environment in a office building having on/off turning control lighting system utilizing daylight. In order to predict the interior varior illumination distribution, the scale model was made and examined under various conditions, such ad difference of window glass, and color pattern of wall, floor, and also ceiling lighting system type. This paper suggests that basic fundamental data of lighting design performance in the concept and schematic stages of design.

  • PDF