• Title/Summary/Keyword: daylight

Search Result 460, Processing Time 0.023 seconds

A Fundamental Study of Optimization to Control on Height of Roller Shade in Office Building through Mock-up Experiment (Mock-up 실험을 통한 사무소 건축물의 Roller Shade 높이 제어 최적화에 관한 기초적 연구)

  • Lim, Ji-Sun;Kim, Yu-Sin;Choi, An-Seop;Lee, Jeong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.148-153
    • /
    • 2008
  • An inflow of daylight to the room offers comfortable view environment, psychological and physical security to people in the room and there are merits such as a work efficiency and energy saving. But, it has many problems as an excessive direct sunlight, cooling and heating. We can expect to have energy saving effect for illumination with comfortable view environment creation through control on height of roller shade. This study will be a used a fundamental approach to control on height of roller shade to changing daylight.

  • PDF

A Study of Green Building Certification Criteria for Advanced Design in Curtainwall of Residential Buildings (주거시설의 커튼월입면를 고려한 친환경 건축물 인증제도 개선방향 연구)

  • Kim, Chul;Mo, Ji-Sun;Kim, Kong-Sook;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.155-160
    • /
    • 2008
  • Recently, curtainwall is built according to expand residential-commercial complex and high-raised buildings in residential buildings. It is that curtainwall has advantage to provide for the building occupants a connection between indoor spaces and the outdoors through the introduction of daylight and views into the regularly occupied areas of the building. These buildings also make a result increasing the amount used energy in domestic residence. Therefore, Aims of this study is to suggest advanced design through analysis of daylight, energy and envelope elements in GBCC and glazing simulation depended on case studies.

  • PDF

Sky Ratio Diagram for the Evaluation of Daylight Environment at the Children's Playground (어린이놀이터의 빛환경 평가를 위한 천공률산정도 작성)

  • Kim, Won Woo;Kim, Eun Shim
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.39-44
    • /
    • 2012
  • The children's playgrounds have been installed almost from the beginning when the first apartment complex was built. The brightness of a playground has not been considered in the architectural plan. The site of the playground has been chosen based on availability without making a detailed review on its daylight environment. The purpose of this study is to provide the Sky Ratio Diagram for the evaluation of daylight environment at the children's playground in apartment complexes. the Sky Ratio Diagram has 100 points, each point has a value of equal to the sky ratio 1%. Through case studies, the Sky Ratio Diagram was verified whether it could be practically applied to the actual playgrounds. This research is meaningful in that it suggests a way to quantitatively evaluate the brightness of a playground. The Sky Ratio Diagram suggested in this study can be practically used when choosing a site for a playground within an apartment complex.

A Study on the Experiment of Luminous Environment in Classroom of An Elementary School (초등학교 교실의 빛 환경 실측에 관한 연구)

  • Park, Kyung-Eun;Kim, Jun-Tae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.9 no.5
    • /
    • pp.13-21
    • /
    • 2002
  • Daylighting in educational environment is very important as it has an effect on students' performance as well as in their visual health. It is regarded as a good energy conservation method in saving energy used for lighting. This study conducted initial daylight measurements to analyze luminous environment in classrooms of Korean elementary school. The results indicated that the typical classroom had a reasonable level of daylight. However, it also found that the classroom had some problems of the uniformity of illuminance and the contrast of brightness of surfaces in the classroom. It is argued that daylighting design for school classroom should consider these aspects to make daylit classrooms ideal so as to provide comfortable visual environment.

Study on the Oxidative Stability of Korean Evening Primrose Oil (한국산 달맞이꽃 종자유의 산화안정성에 관한 연구)

  • 표영희;김인숙;안명수
    • Korean journal of food and cookery science
    • /
    • v.5 no.2
    • /
    • pp.27-34
    • /
    • 1989
  • In the present study, the oxidative stability of Korean evening primrose oil (EPO) stored in various conditions, i.e., dark, cool, fluorescent light and daylight irradiation were investigated. Furthermore difference between the compositional content of gamma-linolenic acid (GLA) of EPO and that of alpha-linolenic acid of soybean oil (SOY) undergoing various modes of oxidation was observed. The results of the present study were as follows: More rapid autoxidative reations of EPO than that of SOY in vairous conditions increased in order of daylight, fluorescent light, cool and dark. Espectially, autoxidative rates of EPO increased rapidly on exposure to daylight and fluorescent light. This probably was due to chlorophyll functioned as a photosensitizer resulting in rapid oxidation of the EPO during irrdadiation of light. However, there was no difference between compositional content of GLA in EPO and alpha-linolenic acid in SOY undergoing various modes of oxidation. Therefore, theripid oxidative rate of EPO could be due to the catalytic effect of the chlorophyll on the photoxidation and the free radical reaction of PUFA.

  • PDF

A Daylight Calculation Method for a Louver System Under the Uniform Sky Condition

  • Kim, Kang-Soo;Hwang, Young-Seok
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 1999
  • The configuration factors in the flux transfer method are applied to calculate daylight factors reaching a station point. To analyze the window equipped with a louver system, geometrical correlation is used for the length shielded by the louver. The space in front of a window is assumed to be an imaginary outdoor space for calculating the luminance of the louver system. The data calculated from this study are compared with SUPERLlTE simulation data and the scale model data. Scale model data are collected on the roof of the Engineering building at Korea University in Seoul under the uniform sky condition.

  • PDF

A study of Daylight Performance at Changdeokgung Nakseonjae (창덕궁 낙선재의 주광성능 분석)

  • Sung, Yeon-Ju;Kim, Yu-Sin;Choi, An-Seop;Han, Wook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.13-16
    • /
    • 2008
  • The aim of this study is to analyze the daylight performance at Changdeokgung Nakseonjae that is the representative and most well preserved Korean royal palace. As a result of measuring illuminance and luminance, direct sunlight is cut off by the eaves and reflective light from the court comes in the inside of the upper floor. As the layer of window is increased, daylight is decreased and the illuminance distribution is more stable because of decreasing of illuminance change. This study would be used as preliminary data for applying characteristics of lighting environment of Korean royal palace to modern architecture.

  • PDF

Analysis of experimental data on daylight responsive dimming system performance for determining on effective dimming ratio (광센서 조광제어시스템의 효율적인 조광율 결정을 위한 실험 데이터 분석)

  • Kim, Ga-Young;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.167-172
    • /
    • 2005
  • This study based on the experimental data on the daylight responsive dimming systems performance. The purpose of this study increases the energy-saving effects by reducing excessive intensity of radiation of artificial lighting through analyzing incident daylight. The photosensor sends amounts of detected luminous flux to digital control unit(DCU) as a signal and then, it can decide dimming ratios, by received a proper dimming signal from DCU. Generally it is effective to control artificial lighting with the different control ratio of each row by setting a photosensor as same numbers and rows as artificial lighting. However, it is ineffective to do in initial costs of systems aspect in offices. By analyzing the data of this performance and finding regular ration between photosensors. we will execute different dimming ratios to each row of artificial lighting by a single photosensor.

  • PDF

Evaluation of Energy Consumptions in Daylight Responsive Dimming Systems (광센서 조광제어시스템의 소비전력 평가)

  • Lee, Soon-Ji;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.195-199
    • /
    • 2006
  • This study aims to measure amount of the reduction ratio of energy consumptions by the daylight responsive dimming systems, which uses daylighting and electric lighting. The results of this study show that the reduction ratio of electric power is better 'clear sky' by sky condition and 'window side of room' by zoning. When calculating reduction ratio of energy consumptions with used times in real office space, it tells that the result of real office was higher ratio than that of experimental space. For this study which presents efficient use of daylight in office environment, it will be basis of improving energy performance.

  • PDF

Computer Simulation on the Characteristics of Daylight Distributions by Grating Louver System in a Pair Glass (복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.117-120
    • /
    • 2009
  • New shading system, which is Grating Louver System into a pair glass, is proposed for integrated lighting system between Daylight Responsive Dimming Systems and shading system in this study. The optimized distance of louvers, which is to block direct sunlight into a space, is calculated. Grating Louver System was simulated using Desktop Radiance 2.0 of lighting simulation software for comparing daylight distribution and changes of control slope by distance from window to back wall with roller shading system controlled by sun profile angle.

  • PDF