• 제목/요약/키워드: data gating technique

검색결과 18건 처리시간 0.024초

Characterization of Supercontinuum and Ultraviolet Pulses by Using XFROG

  • Tsermaa, Baatarchuluun;Yang, Byung-Kwan;Kim, Myung-Whun;Kim, Jin-Seung
    • Journal of the Optical Society of Korea
    • /
    • 제13권1호
    • /
    • pp.158-165
    • /
    • 2009
  • We present cross-correlation frequency-resolved optical gating (XFROG) measurements of supercontinuum pulses generated by using a photonic crystal fiber (PCF), and ultraviolet (UV) pulses generated by frequency doubling of infrared ultra-short pulses. Since supercontinuum pulses have broad spectra, XFROG measurement typically requires using an extremely thin nonlinear crystal which has a thickness of sub-ten microns. Instead of using such a thin crystal, we employed a relatively thick crystal which was mounted on a galvanometer in order to achieve a phase-matching over the whole spectral bandwidth of the supercontinuum pulses by a crystal-dithering technique. Experimental results of the retrieved phase and intensity were in fair agreement with the independently measured data.

Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future Directions

  • Wang, Xiaoqing;Uecker, Martin;Feng, Li
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.252-265
    • /
    • 2021
  • Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard non-invasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for real-time cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.

스마트카드 적용을 위한 저전력 통합 암호화 엔진의 설계 (Low Power Implementation of Integrated Cryptographic Engine for Smart Cards)

  • 김용희;정용진
    • 대한전자공학회논문지SD
    • /
    • 제45권6호
    • /
    • pp.80-88
    • /
    • 2008
  • 본 논문에서는 스마트카드 적용을 위하여 국내외 블록 암호화 표준 알고리즘인 3-DES(Triple Data Encryption Standard), AES(Advanced Encryption Standard), SEED, HASH(SHA-1)를 통합한 저전력 암호화 엔진을 하드웨어로 구현하였다. 휴대용 기기에 필수적인 작은 면적과 저전력을 위하여 하나의 라운드에 대한 각각의 암호화 블록을 구현한 후 반복동작을 하도록 설계하였고 두 단계의 클록 게이팅 기술을 적용하였다. 설계한 통합 암호화 엔진은 ALTERA Excalibur EPXA10F1020C2를 사용하여 검증하였고 합성결과 7,729 LEs와 512 바이트 ROM을 사용하여 최대 24.83 MHz 속도로 동작이 가능하였다. 삼성 0.18 um STD130 CMOS 스탠다드 셀 라이브러리로 합성한 결과 44,452 게이트를 사용하며 최대 50 MHz의 속도로 동작이 가능하였다. 또한 전력소모를 측정한 결과 25 MHz의 속도로 동작할 경우 3-DES, AES, SEED, SHA-1 모드일 때 각각 2.96 mW, 3.03 mW, 2.63 mW, 7.06 mW의 전력소모를 할 것으로 예측되었다. 이러한 저전력 통합 암호화 엔진은 스마트카드 적용에 가장 적합한 구조를 갖고 있으며 그 외에도 다양한 암호화 시스템에 적용될 수 있을 것으로 판단된다.

협동 표적 추적을 위한 확률적 데이터 연관 기반 레이더 및 ESM 센서 측정치 융합 기법의 실험적 연구 (Experimental Research on Radar and ESM Measurement Fusion Technique Using Probabilistic Data Association for Cooperative Target Tracking)

  • 이새움;김은찬;정효영;김기성;김기선
    • 한국통신학회논문지
    • /
    • 제37권5C호
    • /
    • pp.355-364
    • /
    • 2012
  • 협동교전능력을 위한 표적정보 수집, 실시간 정보융합, 공동 상황인식 기능 구현을 위하여 표적 처리기법 연구는 중요하다. 이러한 표적 처리 연구 중, 표적의 추적의 문제는 센서로부터 얻어진 측정값을 사용하여 표적의 상태를 예측하는 것으로부터 시작한다. 그러나 상태 예측에 사용되는 센서의 측정값들은 불확실성을 갖고 있기 때문에 측정된 정보에 어느 정도의 신뢰성을 부여할 수 있느냐가 중요한 문제가 된다. 따라서 이를 위해 다중 센서를 이용한 기법이 요구되고, 보편적으로 사용되는 확률적 데이터연관 기법으로부터 다중 센서를 이용한 표적 추적을 위해서는 이종 센서로부터 제공된 측정값들을 처리하기 위한 정보융합 기법이 필요하다. 본 논문에서는 레이더 및 ESM 센서에서 측정된 측정값 정보융합을 통하여 확률데이터연관 필터를 이용한 표적의 트랙 추정 성능을 향상시키기 위한 방법을 구체적으로 분석하여 정보를 결합하기 위한 새로운 실시간측정값 융합 기법을 제안하고 확률데이터연관을 통해 추적할 표적의 트랙을 추정하는 방법을 분석하였다. 모의실험을 통해 제안된 기법들이 선형 혹은 회전 운동하는 모델들에 대해 향상된 추정 결과를 보여준다.

Lifetime Maximization of Wireless Video Sensor Network Node by Dynamically Resizing Communication Buffer

  • Choi, Kang-Woo;Yi, Kang;Kyung, Chong Min
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권10호
    • /
    • pp.5149-5167
    • /
    • 2017
  • Reducing energy consumption in a wireless video sensor network (WVSN) is a crucial problem because of the high video data volume and severe energy constraints of battery-powered WVSN nodes. In this paper, we present an adaptive dynamic resizing approach for a SRAM communication buffer in a WVSN node in order to reduce the energy consumption and thereby, to maximize the lifetime of the WVSN nodes. To reduce the power consumption of the communication part, which is typically the most energy-consuming component in the WVSN nodes, the radio needs to remain turned off during the data buffer-filling period as well as idle period. As the radio ON/OFF transition incurs extra energy consumption, we need to reduce the ON/OFF transition frequency, which requires a large-sized buffer. However, a large-sized SRAM buffer results in more energy consumption because SRAM power consumption is proportional to the memory size. We can dynamically adjust any active buffer memory size by utilizing a power-gating technique to reflect the optimal control on the buffer size. This paper aims at finding the optimal buffer size, based on the trade-off between the respective energy consumption ratios of the communication buffer and the radio part, respectively. We derive a formula showing the relationship between control variables, including active buffer size and total energy consumption, to mathematically determine the optimal buffer size for any given conditions to minimize total energy consumption. Simulation results show that the overall energy reduction, using our approach, is up to 40.48% (26.96% on average) compared to the conventional wireless communication scheme. In addition, the lifetime of the WVSN node has been extended by 22.17% on average, compared to the existing approaches.

좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가 (Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients)

  • 조재영;배선명;윤인하;이호연;강태영;백금문;배재범
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.297-303
    • /
    • 2014
  • 목 적 : Deep inspiration breath-hold(DIBH) 기법을 이용한 좌측 유방암의 방사선치료 중 환자의 호흡과 심장 위치의 변화에 대한 분석을 통해 DIBH 기법의 치료 재현성을 평가하고자 한다. 대상 및 방법 : 유방보존수술 후 DIBH 기법을 적용한 좌측 유방암 환자 3명을 대상으로 하였다. 전산화치료계획시스템(Eclipse version 10.0, Varian, USA)을 이용하여 자유호흡상태 Computed Tomography(CT)와 DIBH CT에서 동일한 전산화치료계획을 수립하여 심장의 체적과 선량을 비교하였고, RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA)의 데이터를 이용하여 환자의 호흡을 분석하였다. 치료 중 Electronic portal imaging device(EPID)를 이용한 Cine Acquisition 방법으로 영상을 획득하여 Varian 사의 Offline Review (ARIA 10, Varian, USA)에서 심장의 장축 거리를 측정하였다. 조사야 내 심장의 포함 정도를 비교 평가하기 위하여 동일한 3개(A, B, C)의 지점에서 길이 측정을 진행하였다. 결 과 : 자유호흡상태와 DIBH를 적용한 두 가지 전산화치료계획에서 심장평균선량 (6.82 vs 1.91 Gy), 심장의 V30 (68.57 vs $8.26cm^3$), V20(76.43 vs $11.34cm^3$)의 차이를 확인 할 수 있었다. 각 환자의 치료 중 DIBH 구간에서 호흡 진폭에 대한 표준편차의 평균값은 각각 ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$로 분석되었다. 치료 중 획득한 영상에서 조사야 내에 포함되는 심장의 길이를 측정한 후 전산화치료계획에서의 심장의 길이와 비교한 결과 최대값은 0.32 cm, 최소값은 0.00 cm로 확인 되었다. 결 론 : 좌측 유방암 환자 치료 시 DIBH를 적용할 경우 심장에 들어가는 선량을 줄이기 위한 전산화치료계획을 수립하는데 용이할 뿐만 아니라, 실제 치료 중에도 심장의 위치에 대한 정확한 재현성과 심장 선량을 감소시킬 수 있다는 것을 확인할 수 있었다. 또한 EPID의 Cine acquisition 방법은 치료 선량 외에 추가적인 선량 없이 DIBH의 재현성 평가를 위한 매우 효과적인 방법이라고 생각된다.

지상관측 레이다 산란계를 이용한 벼 군락의 후방산란계수 측정 (Measurement of Backscattering Coefficients of Rice Canopy Using a Ground Polarimetric Scatterometer System)

  • 홍진영;김이현;오이석;홍석영
    • 대한원격탐사학회지
    • /
    • 제23권2호
    • /
    • pp.145-152
    • /
    • 2007
  • 본 논문은 지표면 현상의 관측에 날씨의 영향을 거의 받지 않는 마이크로파 L-밴드(1.95 GHz)와 C-밴드(5.3 GHz) scatterometer 시스템을 이용하여 농업과학기술원 내의 논에서 자라는 추청벼를 대상으로 2006년 5월 29일부터 10월 9일까지 생육에 따른 군락의 후방산란계수를 관측한 데이터와 작물의 생육과의 관계를 살펴보고 또한, 측정 시스템의 개요, 측정 시스템의 보정 방법들을 기술하고자 한다. Scatterometer 시스템의 송수신기로 HP 8753D 벡터 네트워크 분석기를 사용하며, 타워 위에 안테나를 설치하여 3.4 m의 높이에서 측정하도록 하였다. L-밴드와 C-밴드 scatterometer는 VV-, VH-, HV-, HH-편파를 측정하여 fully polarimetric한 데이터를 얻도록 설계된 레이더시스템으로 입사각을 $30^{\circ}{\sim}60^{\circ}$에서 $10^{\circ}$간격으로 각각 30개의 독립적인 샘플을 측정하여 통계적으로 후방산란계수를 얻었다. 타워에서 발생하는 전파 잡음과 안테나 패턴의 부엽에 의한 지면에서의 수직반사(coherent 성분) 전파를 제거하기 위해 네트워크 분석기의 time gating 기능을 사용하며, 55 cm 크기의 trihedral 전파반사기를 보정용 반사기로 사용하고, STCT(single target calibration technique) 방법을 이용하여 시스템을 보정하였다. 측정 결과를 분석하여 주파수, 입사각도, 편파의 변화에 대한 벼의 후방산란 특성과 벼의 생육상태와의 관계를 살펴보았다. L-밴드와 C-밴드 모두 벼의 생육과 밀접한 결과를 나타내었으나, 입사각이 작을 때는 C-밴드와의 상관이 높게 나타났고 입사각이 커질수록 L-밴드와의 상관이 높게 나타났다. 편파는 L-밴드와 C-밴드 모두 hh 편파가, 입사각은 50도에서 가장 생육의 변이를 잘 설명하는 것으로 나타났다. 생육 데이터 모두를 이용한 경우보다는 유수형성기 또는 출수기 등 벼 생육의 질적인 변화를 보이는 시기에 따라 나누어 분석하는 것이 변화추이를 더 잘 설명하는 것으로 나타났다.

Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구 (Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan)

  • 김정열;박훈희;남궁혁;조석원;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF