• Title/Summary/Keyword: data calibration

Search Result 1,813, Processing Time 0.032 seconds

Improvement of Radar Rainfall Estimation Using Radar Reflectivity Data from the Hybrid Lowest Elevation Angles (혼합 최저고도각 반사도 자료를 이용한 레이더 강우추정 정확도 향상)

  • Lyu, Geunsu;Jung, Sung-Hwa;Nam, Kyung-Yeub;Kwon, Soohyun;Lee, Cheong-Ryong;Lee, Gyuwon
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.109-124
    • /
    • 2015
  • A novel approach, hybrid surface rainfall (KNU-HSR) technique developed by Kyungpook Natinal University, was utilized for improving the radar rainfall estimation. The KNU-HSR technique estimates radar rainfall at a 2D hybrid surface consistings of the lowest radar bins that is immune to ground clutter contaminations and significant beam blockage. Two HSR techniques, static and dynamic HSRs, were compared and evaluated in this study. Static HSR technique utilizes beam blockage map and ground clutter map to yield the hybrid surface whereas dynamic HSR technique additionally applies quality index map that are derived from the fuzzy logic algorithm for a quality control in real time. The performances of two HSRs were evaluated by correlation coefficient (CORR), total ratio (RATIO), mean bias (BIAS), normalized standard deviation (NSD), and mean relative error (MRE) for ten rain cases. Dynamic HSR (CORR=0.88, BIAS= $-0.24mm\;hr^{-1}$, NSD=0.41, MRE=37.6%) shows better performances than static HSR without correction of reflectivity calibration bias (CORR=0.87, BIAS= $-2.94mm\;hr^{-1}$, NSD=0.76, MRE=58.4%) for all skill scores. Dynamic HSR technique overestimates surface rainfall at near range whereas it underestimates rainfall at far ranges due to the effects of beam broadening and increasing the radar beam height. In terms of NSD and MRE, dynamic HSR shows the best results regardless of the distance from radar. Static HSR significantly overestimates a surface rainfall at weaker rainfall intensity. However, RATIO of dynamic HSR remains almost 1.0 for all ranges of rainfall intensity. After correcting system bias of reflectivity, NSD and MRE of dynamic HSR are improved by about 20 and 15%, respectively.

Calibration of Hargreaves Equation Coefficient for Estimating Reference Evapotranspiration in Korea (우리나라 기준증발산량 추정을 위한 Hargreaves 공식의 계수 보정)

  • Hwang, Seon-ah;Han, Kyung-hwa;Zhang, Yong-seon;Cho, Hee-rae;Ok, Jung-hun;Kim, Dong-Jin;Kim, Gi-sun;Jung, Kang-ho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.4
    • /
    • pp.238-249
    • /
    • 2019
  • The evapotranspiration is estimated based on weather factors such as temperature, wind speed and humidity, and the Hargreaves equation is a simple equation for calculating evapotranspiration using temperature data. However, the Hargreaves equation tends to be underestimated in areas with wind speeds above 3 m s-1 and overestimated in areas with high relative humidity. The study was conducted to determine Hargreaves equation coefficient in 82 regions in Korea by comparing evapotranspiration determined by modified Hargreaves equation and the Penman-Monteith equation for the time period of 2008~2018. The modified Hargreaves coefficients for 50 inland areas were estimated to be 0.00173~0.00232(average 0.00196), which is similar to or lower than the default value 0.0023. On the other hand, there are 32 coastal areas, and the modified coefficients ranged from 0.00185 to 0.00303(average 0.00234). The east coastal area was estimated to be similar to or higher than the default value, while the west and south coastal areas showed large deviations by area. As results of estimating the evapotranspiration by the modified Hargreaves coefficient, root mean square error(RMSE) is reduced from 0.634~1.394(average 0.857) to 0.466~1.328(average 0.701), and Nash-Sutcliffe Coefficient(NSC) increased from -0.159~0.837(average 0.647) to -0.053~0.910(average 0.755) compared with original Hargreaves equation. Therefore, we confirmed that the Hargreaves equation can be overestimated or underestimated compared to the Penman-Monteith equation, and expected that it will be able to calculate the high accuracy evapotranspiration using the modified Hargreaves equation. This study will contribute to water resources planning, irrigation schedule, and environmental management.

A Comparative Study on Quantifying Uncertainty of Vitamin A Determination in Infant Formula by HPLC (HPLC에 의한 조제분유 중 비타민 A 함량 분석의 측정불확도 비교산정)

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.152-159
    • /
    • 2008
  • The purpose of this study was to determine the accurate quantification of vitamin A in infant formula by comparing two different standard stock solutions as well as various sample weights using high performance liquid chromatography. The sources of uncertainty in measurement, such as sample weight, final smaple vloume, and the instrumental results, were identified and used as parameters to determine the combined standard uncertainty based on GUM(guide to the expression of uncertainty in measurement) and the Draft EURACHEM/CITAC Guide. The uncertainty components in measuring were identified as standard weight, purity, molecular weight, dilution of the standard solution, calibration curve, recovery, reproducibility, sample weight, and final sample volume. Each uncertainty component was evaluated for type A and type B and included to calculate the combined uncertainty. The analytical results and combined standard uncertainties of vitamin A according to the two different methods of stock solution preparation were 627 ${\pm}$ 33 ${\mu}$g R.E./100 g for 1,000 mg/L of stock solution, and 627 ${\pm}$ 49 ${\mu}$g R.E./100 g for 100 mg/L of stock solution. The analytical results and combined standard uncertainties of vitamin A according to the various sample weighs were 622 ${\pm}$ 48 ${\mu}$g R.E./100 g, 627 ${\pm}$ 33 ${\mu}$g R.E./100 g, and 491 ${\pm}$ 23 ${\mu}$g R.E./100 g for 1 g, 2 g, and 5 g of sampling, respectively. These data indicate that the preparation method of standard stock solution and the smaple amount were main sources of uncertainty in the analysis results for vitamin A. Preparing 1,000 mg/L of stock solution for standard material sampling rather than 100 mg, and sampling not more than 2 g of infant formula, would be effective for reducing differences in the results as well as uncertainty.

Analytical Validation of Rosmarinic Acid in Water Extract of Perilla frutescens Britton var. acuta Kudo as Functional Health Ingredient (건강기능식품 기능성 원료로써 장흥 차조기 열수 추출물의 지표성분인 로즈마린산 분석법 검증)

  • Park, Sung-Yong;Kim, Jung-Eun;Choi, Chul-Yung;Lee, Dong-Wook;Kim, Ki-Man;Yoon, Goo;Yoon, In-Su;Moon, Hong-Seop;Cho, Seung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.1
    • /
    • pp.85-88
    • /
    • 2015
  • This study attempted to establish an HPLC analysis method for determination of marker compounds as a part of material standardization for the development of health functional food materials from Perilla frutescens Britton var. acuta Kudo. The quantitative determination method of rosmarinic acid as a marker compound of P. frutescens Britton var. acuta Kudo extract (PFE) was optimized by HPLC analysis using a C18 column ($4.6{\times}150mm$, $5{\mu}m$) with 0.1% acetic acid as the elution gradient and methanol as the mobile phase at a flow rate of 1 mL/min and detection wavelength of 280 nm. The HPLC/UV method was applied successfully to quantification of the marker compound in PFE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9995, and the limit of detection and limit of quantitation were $0.36{\mu}g/mL$ and $1.2{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 3.21% and 1.43%, respectively. Recovery rate test at rosmarinic acid concentrations of 12.5, 25 and $50{\mu}g/mL$ scored between 97.04~98.98% with RSD values from 0.25~1.97%. These results indicate that the established HPLC method is very useful for the determination of marker compound in PFE to develop a health functional material.

Evaluation of Land Use Change Impact on Hydrology and Water Quality Health in Geum River Basin (금강유역의 토지이용 변화가 수문·수질 건전성에 미치는 영향 평가)

  • LEE, Ji-Wan;PARK, Jong-Yoon;JUNG, Chung-Gil;KIM, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.2
    • /
    • pp.82-96
    • /
    • 2019
  • This study evaluated the status of watershed health in Geum River Basin by SWAT (Soil and Water Assessment Tool) hydrology and water quality. The watershed healthiness from watershed hydrology and stream water quality was calculated using multivariate normal distribution from 0(poor) to 1(good). Before evaluation of watershed healthiness, the SWAT calibration for 11 years(2005~2015) of streamflow(Q) at 5 locations with 0.50~0.77 average Nash-Sutcliffe model efficiency and suspended solid (SS), total nitrogen(T-N), and total phosphorus(T-P) at 3 locations with 0.67~0.94, 0.59~0.79, and 0.61~0.79 determination coefficient($R^2$) respectively. For 24 years (1985~2008) the spatiotemporal change of watershed healthiness was analyzed with calibarted SWAT and 5 land use data of 1985, 1990, 1995, 2000, and 2008. The 2008 SWAT results showed that the surface runoff increased by 40.6%, soil moisture and baseflow decreased by 6.8% and 3.0% respectively compared to 1985 reference year. The stream water quality of SS, T-N, and T-P increased by 29.2%, 9.3%, and 16.7% respectively by land development and agricultural activity. Based on the 1985 year land use condition. the 2008 watershed healthiness of hydrology and stream water quality decreased from 1 to 0.94 and 0.69 respectively. The results of this study be able to detect changes in watershed environment due to human activity compared to past natural conditions.

Development of Simultaneous Analytical Method for Streptomycin and Dihydrostreptomycin Detection in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Streptomycin 및 Dihydrostreptomycin 동시시험법 개발)

  • Lee, Han Sol;Do, Jung-Ah;Park, Ji-Su;Park, Shin-Min;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Choi, Young-Nae;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.13-21
    • /
    • 2019
  • A method was developed for the simultaneous detection of an antibiotic fungicide, streptomycin, and its metabolite (dihydrostreptomycin) in agricultural products using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The samples were extracted using methanol adjusted to pH 3 using formic acid, and purified with a HLB (Hydrophilic lipophilic balance) cartridge. The matrix-matched calibration curves were constructed using seven concentration levels, from 0.001 to 0.1 mg/kg, and linearity of five agricultural products (hulled rice, potato, soybean, mandarin, green pepper), with coefficients of determination $(R^2){\geq}0.9906$, for streptomycin and dihydrostreptomycin. The mean recoveries at three fortification levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n = 5) were from 72.0~116.5% and from 72.1~116.0%, and relative standard deviations were less than 12.3% and 12.5%, respectively. The limits of quantification (LOQ) were 0.01 mg/kg, which are satisfactory for quantification levels corresponding with the Positive List System. All optimized results satisfied the criteria ranges requested in the Codex guidelines and the Food Safety Evaluation Department guidelines. The present study could serve as a reference for the establishment of maximum residue limits and be used as basic data for detection of streptomycin and dihydrostreptomycin in food.

Nondestructive Methods for the Detection of Internal Decay and the Vitality Measurement of Old-Giant Trees (노거수 활력 측정 및 내부 부후 검출을 위한 비파괴검사법)

  • Gao, Yuliang;Cha, Byeong Jin
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.1
    • /
    • pp.144-157
    • /
    • 2009
  • Nondestructive methods to check the vitality of trees and to find out internal decay of old-giant trees include the use of electrical resistance, ultrasound transmission time, microdrilling, and infrared thermography etc. Among these, ultrasound transmission offers some advantages compared to others such as it is an entirely nondestructive detection method and it can be applied to very big trees. However, the ultrasound equipment is comparatively expensive and not broadly spread yet. On the other hand, Shigometer is versatile to be applied to check vitality of the tree and find out internal decay. Electrical conductivity of plant tissues is a very useful characteristics to determine the vitality and internal decay of trees. Electrical resistance of cambial area tells about the vitality of a tree and electrical resistance of heartwood reveals discoloration or decay of it. For determination of the vitality of the tree, the standard equation for calibration of measured electrical resistances should be developed by measuring and analyzing electrical resistance from at least 30-40 trees of the same species with that tree. All the factors, especially tree species, diameter of the stem, and temperature, which can altered the electrical resistance of trees, should be taken into consideration in the development of the equation. If the standard equation is developed for old-giant trees that we should conserve, it will be very useful. In addition, periodical and continued measuring of a certain tree will help to determine the condition of the tree by comparing the measurement with accumulated data of the tree. Measuring electrical resistance of wood might not require the standard equation. But it also needs to check electrical resistance of sound wood of the same tree species. If the stems that should be examined is thicker than 40cm, it is better to use the ultrasound measurement combined to Shigometer.

Development of Analytical Method for Kasugamycin in Agricultural Products using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Kasugamycin 시험법 개발)

  • Lee, Han Sol;Do, Jung-Ah;Park, Ji-Su;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.235-241
    • /
    • 2019
  • An analytical method was developed for the determination of an antibiotic fungicide, kasugamycin, in agricultural products (hulled rice, potato, soybean, mandarin and green pepper) using liquid chromatographytandem mass spectrometry (LC-MS/MS). Samples were extracted with methanol adjusted to pH 13 using 1 N sodium hydroxide, and purified with a HLB (hydrophilic lipophilic balance) cartridge. Linearity of a matrix-matched calibration curve using seven concentration levels, from 0.001 to 0.1 mg/kg, was excellent with a correlation coefficient ($R^2$) of more than 0.9998. The limits of detection (LOD) and quantification (LOQ) of instrument were 0.0005 and $0.001{\mu}g/mL$, respectively, and the LOQ of analytical method calculated as 0.01 mg/kg. The average recoveries at three spiking levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n=5) were in the range of 71.2~95.4% with relative standard deviation of less than 12.1%. The developed method was simple and all optimized results was satisfied with the criteria ranges requested in the Codex guidelines and Food Safety Evaluation Department guidelines. The present study could be served as a reference for the establishment of maximum residue limits (MRL) of kasugamycin and be used as basic data for safety management relative to kasugamycin residues in imported and domestic agricultural products.

Development of Analytical Method for Ergot Alkaloids in Foods Using Liquid Chromatoraphy-Tandem Mass Spectrometry (LC-MS/MS를 이용한 식품 중 맥각 알칼로이드 시험법 개발)

  • Chun, So Young;Chong, Euna;Lee, Bomnae;Kwon, Jin-Wook;Park, Hye Young;Kim, Sheenhee;Gang, Giljin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.158-169
    • /
    • 2019
  • Ergot alkaloids are mycotoxin produced by fungi of the Claviceps genus, mainly by Claviceps purpurea in EU. Recently obtained informations indicates necessity for control the ergot in imported grains. Recent occurrence data of ergot alkaloids from EU countries indicate the necessities of management and control these toxins from the imported grains like rye, wheat, oat etc. The aim of this study is to optimize the liquid chromatography-tandem mass spectrometry method for determination of ergot alkaloids (ergometrine, ergosine, ergotamine, ergocornine, ergocryptine, ergocristine and their epimers (-inines) from grain and grain-based food. The test method was optimized by extracting the sample with acetonitrile containing 2 mM ammonium carbonate, purification with Mycosep cartridge, and instrumental analysis by LC-MS/MS using Syncronis C18 column. The standard calibration curves showed linearity with correlation coefficents; $R^2$ >0.99. Mean recoveries ranged from 72.0 to 111.3% at three different fortified levels (20, 50, and $100{\mu}g/kg$). The correlation coefficient expressed as precision was within the range of 1.9-12.9%. The limit or quantifications (LOQ) ranged from 0.012 to $0.058{\mu}g/kg$. The developed analytical method met the criteria of AOAC Int. and CAC validation parameters like accuracy and sensitivity. As a result, it was confirmed that the test method developed in this study is suitable for the simultaneous analysis of six species of ergot alkaloid from grains and grain products.

Development of Continuous Monitoring Method of Root-zone Electrical Conductivity using FDR Sensor in Greenhouse Hydroponics Cultivation (시설 수경재배에서 FDR 센서를 활용한 근권 내 농도의 연속적 모니터링 방법)

  • Lee, Jae Seong;Shin, Jong Hwa
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.409-415
    • /
    • 2022
  • Plant growth and development are also affected by root-zone environment. Therefore, it is important to consider the variables of the root-zone environment when establishing an irrigation strategy. The purpose of this study is to analyze the relationship between the volumetric moisture content (VWC), Bulk EC (ECb), and Pore EC (ECp) used by plant roots using FDR sensors in two types of rockwool media with different water transmission characteristics, using the method above this was used to establish a method for collecting and correcting available root-zone environmental data. For the experiment, two types of rockwool medium (RW1, RW2) with different physical characteristics were used. The moisture content (MC) and ECb were measured using an FDR sensor, ECp was measured after extracting the residual nutrient solution from the medium using a disposable syringe in the center of the medium at a volumetric moisture content (VWC) of 10-100%. Then, ECb and ECp are measured by supplying nutrient solution having different concentration (distilled water, 0.5-5.0) to two types of media (RW1, RW2) in each volume water content range (0 to 100%). The relationship between ECb and ECp in RW1 and RW2 media is best suited for cubic polynomial. The relationship between ECb and ECp according to volume moisture content (VWC) range showed a large error rate in the low volume moisture content (VWC) range of 10-60%. The correlation between the sensor measured value (ECb) and the ECp used by plant roots according to the volumetric water content (VWC) range was the most suitable for the Paraboloid equation in both media (RW1, RW2). The coefficient of determination the calibration equation for RW1 and RW2 media were 0.936, 0.947, respectively.