• 제목/요약/키워드: damping updating

검색결과 42건 처리시간 0.029초

KAERI 채널형 전단벽체의 동적해석; 시스템판별, FE 모델향상 및 시간이력 응답 (Dynamic Analysis of a KAERI Channel Type Shear Wall: System Identification, FE Model Updating and Time-History Responses)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.145-152
    • /
    • 2021
  • KAERI has planned to carry out a series of dynamic tests using a shaking table and time-history analyses for a channel-type concrete shear wall to investigate its seismic performance because of the recently frequent occurrence of earthquakes in the south-eastern parts of Korea. The overall size of a test specimen is b×l×h =2500 mm×3500 mm×4500 mm, and it consists of three stories having slabs and walls with thicknesses of 140 mm and 150 mm, respectively. The system identification, FE model updating, and time-history analysis results for a test shear wall are presented herein. By applying the advanced system identification, so-called pLSCF, the improved modal parameters are extracted in the lower modes. Using three FE in-house packages, such as FEMtools, Ruaumoko, and VecTor4, the eigenanalyses are made for an initial FE model, resulting in consistency in eigenvalues. However, they exhibit relatively stiffer behavior, as much as 30 to 50% compared with those extracted from the test in the 1st and 2nd modes. The FE model updating is carried out to consider the 6-dofs spring stiffnesses at the wall base as major parameters by adopting a Bayesian type automatic updating algorithm to minimize the residuals in modal parameters. The updating results indicate that the highest sensitivity is apparent in the vertical translational springs at few locations ranging from 300 to 500% in variation. However, their changes seem to have no physical meaning because of the numerical values. Finally, using the updated FE model, the time-history responses are predicted by Ruaumoko at each floor where accelerometers are located. The accelerograms between test and analysis show an acceptable match in terms of maximum and minimum values. However, the magnitudes and patterns of floor response spectra seem somewhat different because of the slightly different input accelerograms and damping ratios involved.

Field Measurement and Modal Identification of Various Structures for Structural Health Monitoring

  • Yoshida, Akihiko;Tamura, Yukio
    • 국제초고층학회논문집
    • /
    • 제4권1호
    • /
    • pp.9-25
    • /
    • 2015
  • Field measurements of various structures have been conducted for many purposes. Measurement data obtained by field measurement is very useful to determine vibration characteristics including dynamic characteristics such as the damping ratio, natural frequency, and mode shape of a structure. In addition, results of field measurements and modal identification can be used for modal updating of FEM analysis, for checking the efficiency of damping devices and so on. This paper shows some examples of field measurements and modal identification for structural health monitoring. As the first example, changes of dynamic characteristics of a 15-story office building in four construction stages from the foundation stage to completion are described. The dynamic characteristics of each construction stage were modeled as accurately as possible by FEM, and the stiffness of the main structural frame was evaluated and the FEM results were compared with measurements performed on non-load-bearing elements. Simple FEM modal updating was also applied. As the next example, full-scale measurements were also carried out on a high-rise chimney, and the efficiency of the tuned mass damper was investigated by using two kinds of modal identification techniques. Good correspondence was shown with vibration characteristics obtained by the 2DOF-RD technique and the Frequency Domain Decomposition method. As the last example, the wind-induced response using RTK-GPS and the feasibility of hybrid use of FEM analysis and RTK-GPS for confirming the integrity of structures during strong typhoons were shown. The member stresses obtained by hybrid use of FEM analysis and RTK-GPS were close to the member stresses measured by strain gauges.

Model Updating of an Electric Cabinet using Shaking Table Test

  • Cui, Jintao;Cho, Sung-Gook;Kim, Doo-Kie;Koo, Ki-Young;Cho, Yang-Hee
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.59-62
    • /
    • 2008
  • This paper presents the procedure and the results of modal identification testing of a seismic monitoring system central processing unit cabinet for a nuclear power plant. This paper also provides a model updating for making effective analytical modeling of cabinet-type electrical equipment by comparing the test results with the analysis results. From the test results and their interpretation, modal properties (modal frequency, mode shape, and modal damping) of the specimen were satisfactorily identified. However, the analysis results may need to study further to find the effective and presentative model for the cabinet-type electrical equipment. This paper just presents the first stage of the research project "Development of dynamic behavior analysis technique of dynamic structure system" which is trying to build the lumped mass beam stick model even their results do not agree well with the test results.

  • PDF

초고층건물의 성능평가를 위한 응답의존 시스템판별 및 모델향상 (Output-Only System Identification and Model Updating for Performance Evaluation of Tall Buildings)

  • 조순호
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.19-33
    • /
    • 2008
  • 구조물에 고유한 진동수,모드형태 및 감쇠비 등과 같은 동적성능치를 추출하기 위하여 25층 및 42층 건물에 대하여 자연진동에 의한 동적계측실험을 수행하였다. 고려된 건물은 주요 횡하중 지지기구로서 코아벽체 혹은 전단벽체가 추가된 철근콘크리트건물이며, 입면 혹은 평면상으로 골조가 혼합된 구조형식을 나타낸다. 특히, 25층 건물은 측면에 위치한 코아벽체 이외에 상부로부터 내려오는 전단벽 구조가 4층 바닥이하에서 골조형식으로 전환되는 복잡한 구조이다. 이와 같은 이유 및 건물 주방향의 유사한 강성배치로 매우 근접하고 혼합된 모드형태가 예상되어 시스템판별 시 어려움이 예상된다. 현재까지 개발된 다양한 시스템판별법을 대상건물의 자연진동 실측기록에 적용하여 모달계수를 유도하였으며, 그 결과를 비교 분석하였다. 3개의 주파수영역 및 4개의 시간영역에 근거한 응답의존 시스템판별법이 고려되었다. 서로 다른 시스템판별법에 의하여 추출된 고유진동수 및 감쇠비는 대체로 상당한 일치를 보였으나, 모드형태는 사용된 방법에 따라 정도가 다르게 불일치를 나타냈다. 실험으로부터 추출한 성능치와 초기 유한요소해석 값을 비교해 본 결과 대상건물 모두 적어도 저차 3개의 고유진동수에서 2배 정도의 차이를 나타냈다. 실험과 해석결과의 일치를 위하여 몇몇 수동모델향상이 시도되었으며, 허용할 만한 결과를 획득하였다. 사용된 시스템판별법에 대하여 각자의 장, 단점에 대하여 기술하였으며, 본 연구와 같은 실제 대형구조물에 대하여 자동모델향상기법을 적용할 시 예상되는 문제점에 대하여 토의하였다.

비비례 감쇠 구조의 고유치 문제에 대한 반복적인 동적 축소법 (Dynamic Condensation using Iterative Manner for Structural Eigenproblem with Nonproportional Damping)

  • 조맹효;최동수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.342-349
    • /
    • 2008
  • A selection method of primary degrees of freedom in dynamic condensation for nonproportional damping structures is proposed. Recently, many dynamic condensation schemes for complex eigenanalysis have been applied to reduce the number of degrees of freedom. Among them, iterative scheme is widely used because accurate eigenproperties can be obtained by updating the transformation matrix in every iteration. However, a number of iteration to enhance the accuracy of the eigensolutions may have a possibility to make the computation cost expensive. This burden can be alleviated by applying properly selected primary degrees of freedom. In this study, which method for selection of primary degrees of freedom is best fit for the iterative dynamic condensation scheme is presented through the results of a numerical experiment. The results of eigenanalysis of the proposed method is also compared to those of other selection schemes to discuss a computational effectiveness.

  • PDF

모달 파라미터를 이용한 보 구조물의 모델링 (Modeling of Beam Structures from Modal Parameters)

  • 황우석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.519-522
    • /
    • 2006
  • Accurate modeling of a dynamic system from experimental data is the bases for the model updating or heath monitoring of the system. Modal analysis or modal test is a routine process to get the modal parameters of a dynamic system. The modal parameters include the natural frequencies, damping ratios and mode shapes. This paper presents a new method that can derive the equations of motion for a dynamic system from the modal parameters obtained by the modal analysis or modal test. The present method based on the relation between the eigenvalues and eigenvectors of the state space equation derives the mass, damping and stiffness matrices of the system. The modeling of a cantilevered beam from modal parameters is an example to prove the efficiency and accuracy of the present method. Using the lateral displacements only, not the rotations, gives limited information for the system. The numerical verification up to now gives reasonable results and the verification with the test data is scheduled.

  • PDF

Structural model updating of the Gageocho Ocean Research Station using mass reallocation method

  • Kim, Byungmo;Yi, Jin-Hak
    • Smart Structures and Systems
    • /
    • 제26권3호
    • /
    • pp.291-309
    • /
    • 2020
  • To study oceanic and meteorological problems related to climate change, Korea has been operating several ocean research stations (ORSs). In 2011, the Gageocho ORS was attacked by Typhoon Muifa, and its structural members and several observation devices were severely damaged. After this event, the Gageocho ORS was rehabilitated with 5 m height to account for 100-yr extreme wave height, and the vibration measurement system was equipped to monitor the structural vibrational characteristics including natural frequencies and modal damping ratios. In this study, a mass reallocation method is presented for structural model updating of the Gageocho ORS based on the experimentally identified natural frequencies. A preliminary finite element (FE) model was constructed based on design drawings, and several of the candidate baseline FE models were manually built, taking into account the different structural conditions such as corroded thickness. Among these candidate baseline FE models, the most reasonable baseline FE model was selected by comparing the differences between the identified and calculated natural frequencies; the most suitable baseline FE model was updated based on the identified modal properties, and by using the pattern search method, which is one of direct search optimization methods. The mass reallocation method is newly proposed as a means to determine the equivalent mass quantities along the height and in a floor. It was found that the natural frequencies calculated based on the updated FE model was very close to the identified natural frequencies. In conclusion, it is expected that these results, which were obtained by updating a baseline FE model, can be useful for establishing the reference database for jacket-type offshore structures, and assessing the structural integrity of the Gageocho ORS.

Finite element model updating of an arch type steel laboratory bridge model using semi-rigid connection

  • Altunisik, Ahmet Can;Bayraktar, Alemdar;Sevim, Baris;Kartal, Murat Emre;Adanur, Suleyman
    • Steel and Composite Structures
    • /
    • 제10권6호
    • /
    • pp.541-561
    • /
    • 2010
  • This paper presents finite element analyses, experimental measurements and finite element model updating of an arch type steel laboratory bridge model using semi-rigid connections. The laboratory bridge model is a single span and fixed base structure with a length of 6.1 m and width of 1.1m. The height of the bridge column is 0.85 m and the maximum arch height is 0.95 m. Firstly, a finite element model of the bridge is created in SAP2000 program and analytical dynamic characteristics such as natural frequencies and mode shapes are determined. Then, experimental measurements using ambient vibration tests are performed and dynamic characteristics (natural frequencies, mode shapes and damping ratios) are obtained. Ambient vibration tests are performed under natural excitations such as wind and small impact effects. The Enhanced Frequency Domain Decomposition method in the frequency domain and the Stochastic Subspace Identification method in the time domain are used to extract the dynamic characteristics. Then the finite element model of the bridge is updated using linear elastic rotational springs in the supports and structural element connections to minimize the differences between analytically and experimentally estimated dynamic characteristics. At the end of the study, maximum differences in the natural frequencies are reduced on average from 47% to 2.6%. It is seen that there is a good agreement between analytical and experimental results after finite element model updating. Also, connection percentages of the all structural elements to joints are determined depending on the rotational spring stiffness.

Damage detection in steel structures using expanded rotational component of mode shapes via linking MATLAB and OpenSees

  • Toorang, Zahra;Bahar, Omid;Elahi, Fariborz Nateghi
    • Earthquakes and Structures
    • /
    • 제22권1호
    • /
    • pp.1-13
    • /
    • 2022
  • When a building suffers damages under moderate to severe loading condition, its physical properties such as damping and stiffness parameters will change. There are different practical methods besides various numerical procedures that have successfully detected a range of these changes. Almost all the previous proposed methods used to work with translational components of mode shapes, probably because extracting these components is more common in vibrational tests. This study set out to investigate the influence of using both rotational and translational components of mode shapes, in detecting damages in 3-D steel structures elements. Three different sets of measured components of mode shapes are examined: translational, rotational, and also rotational/translational components in all joints. In order to validate our assumptions two different steel frames with three damage scenarios are considered. An iterative model updating program is developed in the MATLAB software that uses the OpenSees as its finite element analysis engine. Extensive analysis shows that employing rotational components results in more precise prediction of damage location and its intensity. Since measuring rotational components of mode shapes still is not very convenient, modal dynamic expansion technique is applied to generate rotational components from measured translational ones. The findings indicated that the developed model updating program is really efficient in damage detection even with generated data and considering noise effects. Moreover, methods which use rotational components of mode shapes can predict damage's location and its intensity more precisely than the ones which only work with translational data.

Vibration control of a time-varying modal-parameter footbridge: study of semi-active implementable strategies

  • Soria, Jose M.;Diaz, Ivan M.;Garcia-Palacios, Jaime H.
    • Smart Structures and Systems
    • /
    • 제20권5호
    • /
    • pp.525-537
    • /
    • 2017
  • This paper explores different vibration control strategies for the cancellation of human-induced vibration on a structure with time-varying modal parameters. The main motivation of this study is a lively urban stress-ribbon footbridge (Pedro $G\acute{o}mez$ Bosque, Valladolid, Spain) that, after a whole-year monitoring, several natural frequencies within the band of interest (normal paring frequency range) have been tracked. The most perceptible vibration mode of the structure at approximately 1.8 Hz changes up to 20%. In order to find a solution for this real case, this paper takes the annual modal parameter estimates (approx. 14000 estimations) of this mode and designs three control strategies: a) a tuned mass damper (TMD) tuned to the most-repeated modal properties of the aforementioned mode, b) two semi-active TMD strategies, one with an on-off control law for the TMD damping, and other with frequency and damping tuned by updating the damper force. All strategies have been carefully compared considering two structure models: a) only the aforementioned mode and b) all the other tracked modes. The results have been compared considering human-induced vibrations and have helped the authors on making a decision of the most advisable strategy to be practically implemented.