• Title/Summary/Keyword: dairy wastewater

Search Result 40, Processing Time 0.021 seconds

Role of Crossflow Module Media in Gas-liquid-solid Separation and Biomass Retention in Hybrid Anaerobic Filter (교차흐름식 모듈 충전 hybrid 혐기성여상의 기·액·고 분리능 및 슬러지보유능)

  • Chang, Duk;Chae, Hee-Wang;Bae, Hyung-Suk;Chung, In;Han, Sang-Bae;Hur, Joon-Moo;Hong, Ki-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.769-778
    • /
    • 2009
  • Performances and internal behaviors of the upflow hybrid anaerobic filters treating a dairy wastewater were analyzed to identify the functions and roles of the modular crossflow media and sludge bed layer and to discover their interrelationship in the filter. The media could perform independent biological and physical separation role without buildup of sludge bed, while the role of sludge bed was dependent on the function of the media. The filter packed with the crossflow media did not necessarily require the formation of sludge bed when treating a dairy wastewater. Biological contribution of the media was controlled by that of biologically active sludge bed complementing mutually each other. The gas-liquid-solid separation capability of the media was indispensible to ensure the active biological role of sludge bed, since sludge bed buildup without the media had no independently effective biological function. It was believed that the filter in itself could also function as a selector for physical gas-liquid-solid separation resulting in selectively concentrating particles with superior settleability in sludge bed. The sludge bed in the filter played a key role in the physical solids capture from influent as well as biological organics removal.

Characteristics of GHGs Emissions from Wastewater Treatment Process of Dairy Industry (유제품 가공산업의 폐수처리시설로부터 발생되는 온실가스 배출 특성)

  • Kim, Ji-Hye;Oh, Minhee;Kim, Ji-Hyo;Kang, Seong-Min;Jeong, Jae-Heon;Sa, Jae-Hwan;Jeon, Eui-Chan
    • Journal of Climate Change Research
    • /
    • v.7 no.2
    • /
    • pp.103-110
    • /
    • 2016
  • In this study, we researched the characteristics of $CH_4$ and $N_2O$ emission of the wastewater treatment (WWT) process in the dairy industry. For flux measurements at the air-water interface, a floating dynamic flow-through chamber was used above the water surface. $CH_4$ and $N_2O$ concentration from the WWT process was measured by NDIR (Non-Dispersive Infrared) Analyser. In the study, $CH_4$ and $N_2O$ fluxes results showed a distinct difference for each WWT process. 60% of the GHG emissions which was the highest percentage were from the equalization tank. Reactor tank was second with 27% of the total emissions from the WWT. Aeration tank was third with 12% of the total emissions. The tendency was that the more the wastewater was treated, the less GHGs were emitted. $CH_4$ and $N_2O$ showed the same tendency. This indicates that the concentrations and properties of wastewater could affect the tendency.

The Overall Performance Improvement of Microbial Fuel Cells Connected in Series with Dairy Wastewater Treatment

  • Choudhury, Payel;Bhunia, Biswanath;Bandyopadhyay, Tarun Kanti;Ray, Rup Narayan
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.101-111
    • /
    • 2021
  • To improve the potential of single chamber microbial fuel cells (SCMFCs) as an applicable technology, the main challenge is a practical application for larger scales bioenergy production from potent exoelectrogenic microorganism with real dairy wastewater. To increase power generation, three individual MFCs were together operated in series best under the fed batch condition for 15 days. The volume of MFC 1 and MFC 2 is "300 mL" and MFC 3 is "500 mL" respectively. The individual MFCs 1, MFC 2 and MFC 3 gives an open circuit voltage of 0.60 V, 0.66 V and 0.55 V and result in total working voltage when connected in series of 1.745V, which lead an LED to glow. The maximum power densities obtained from MFC 1, MFC 2 and MFC 3 are 62 mW/㎡, 50 mW/㎡ and 45 mW/㎡ (normalized to the surface area of the anodic electrode, which was 50 ㎠ for all three MFCs), and corresponding to current densities of 141 mA/㎡, 155 mA/㎡ and 123 mA/㎡, respectively. Therefore this work suggests the cheapest way to connect microbial fuel cells in series to gain power with the lowest operating cost and chemical oxygen demand (COD) removal.

Application of magnetic activated sludge process for a milking parlor wastewater treatment with nitrogen and phosphorus recovery

  • Onodera, Toshihito;Sakai, Yasuzo;Kashiwazaki, Masaru;Ihara, Ikko;Lal, Saha Mihir
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.3
    • /
    • pp.20-25
    • /
    • 2021
  • Milking parlor wastewater contains high concentration suspended solid (SS), nitrogen, and/or phosphate as well as organic compounds. A new biological wastewater process by magnetic separation, magnetic activated sludge (MAS) process, was applied to milking parlor wastewater treatment process. A three step wastewater treatment process of coagulation sedimentation / ammonia stripping (C/S), magnetic activated sludge process and contact oxidation (CO) was proposed for removal of these pollutants. First step, C/S process recovered 96% TN and 96% PO43--P as resource for fertilizer from the wastewater. 81% biochemical oxygen demand (BOD) in wastewater was removed after MAS process. As a results, all pollutant concentrations satisfied Japanese effluent standards. Most of residual BOD and SS were removed by the CO process. It was estimated that the proposed process could reduce the process space to 1/7.

Operation of UASB Reactor for Treatment of Dairy Wastewaters (유가공폐수 처리를 위한 UASB 반응조 운전)

  • Bae, Byung-Uk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.3 no.2
    • /
    • pp.37-45
    • /
    • 1995
  • The performance and the operational problems of UASB(Upflow Anaerobic Sludge Blanket) reactor for treatment of dairy wastewaters were investigated. Synthetic milk wastewater was successfully treated up to the loading rate of 3.9kg $COD/m^3.day$, with a specific gas production rate of 1. 23 I/I. day and a COD removal efficiency of over 90%. However, the sludge rising was observed at the loading rate of 2.1kg $COD/m^3.day$, due probably to the formation of scum layer at the surface of settling compartment. The BMP(biochemical methane potential) of raw milk wastewater and ice cream wastewater, measured by using SBT(serum bottle test), were 0.135 and 0.66ml $CH_4/mg\;COD_{added}$, respectively. The sludge activity increased more than 8 times from 0.159g $COD-CH_4/g$ VSS. d during 90 days of operation.

  • PDF

Treatment of milking parlor wastewater containing tetracycline by magnetic activated sludge and contact oxidation process

  • Gaowa, Gaowa;Sakai, Yasuzo;Xie, Xiaonan;Saha, Mihir Lal;Ihara, Ikko
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.3
    • /
    • pp.32-36
    • /
    • 2021
  • Milking parlor wastewater contains not only high concentrations of organic compounds, but often animal antibiotics. To discharge the antibiotics to public water area cause problem of antibiotics resistant bacteria. Magnetic separation was applied into improvement of milking parlor wastewater treatment process. A new process, composed of a magnetic activated sludge (MAS) process and a contact oxidation (CO) process, was proposed in this study. This process was evaluated by the simulated milking parlor wastewater (4500 mg/L CODCr and 10 mg/L tetracycline) using a bench scale experimental setup. As a result, the process was able to removed 97% CODCr as well as 94% tetracycline. The MLVSS (mixed liquor volatile suspended solids) concentration of MAS was maintained at 12000 mg/L without excess sludge drawing. This process was considered to be useful as treatment process for milking parlor wastewater in which waste-milk including antibiotics is often discharged.

Research on the Amount of Wastewater Produced from the Different Milking System (착유시스템별 세척수 발생량에 관한 연구)

  • 최동윤;강희설;곽정훈;최희철;김재환;김태일;이덕수;권두중;한정대
    • Journal of Animal Environmental Science
    • /
    • v.7 no.2
    • /
    • pp.77-82
    • /
    • 2001
  • This research was carried out to investigate the daily amount and characteristics of wastewater produced from bucket milkers, pipeline, tandem ad herringbone milking system for washing operations after milking included 28 dairy farms. The average amount of wastewater produced from milking system was 9.8l/head/day. The amount of wastewater varied from a low of 8.2 litters/head/day(pipeline milking system) to 13.4 litter/head/day(herringbone milking system). The moisture content, Biochemical Oxygen Demand($BOD_5$), Chemical Oxygen Demand($COD_{Mn}$), Suspended Solids(SS), Total Nitrogen(T-N) and Total Phosphorus(T-P) concentration of wastewater were 99.9%, 394mg/l, 417.3mg/l, 1,201.3mg/l, 3.78mg/l, 0.51mg/l.

  • PDF

Using response surface methodology and Box-Behnken design in the study of affecting factors on the dairy wastewater treatment by MEUF

  • Khosroyar, Susan;Arastehnodeh, Ali
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.335-342
    • /
    • 2018
  • Micelle-Enhanced Ultrafiltration (MEUF) is a membrane separation processes that improving ultrafiltration process with the formation of micelles of the surface active agents. Surface active agents are widely used to improve membrane processes due to the ability to trap organic compounds and metals in the treatment of industrial waste water. In this study, surface active agents are used to improve micelle-enhanced ultrafiltration (MEUF) to reduce chemical oxygen demand (COD), total dissolved solid (TDS), turbidity and clogging the membrane in dairy wastewater treatment. Three important operational factors (anionic surface active agent concentration, pressure and pH) and these interactions were investigated by using response surface methodology (RSM) and Box-Behnken design. Results show that due to the concentration polarization layer and increase the number of Micelles; the anionic surface active agent concentration has a negative effect on the flux and has a positive effect on the elimination of contamination indices. pH, and the pressure have the greatest effect on flux. On the other hand, it could be stated that these percentages of separation are in the percentages range of Nano-filtration (NF). While MEUF process has higher flux than NF process. The results have been achieved at lower pressure while NF process needs high pressure, thus making MEUF is the replacement for the NF process.

Effect of Chlorination for Bulking Control on the Organic Removal Activity of Activated Sludge Treating Dairy Wastewater (유가공 폐수의 활성슬러지 처리에서 벌킹 제어용 염소가 미생물의 유기물 분해 활성에 미치는 영향)

  • Nam Se-Yong;Choi Jin-Taek
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.96-101
    • /
    • 2006
  • Chlorination inhibition on the organic removal activity of activated sludge microorganism was investigated in this study. It is well known that chlorination improves the settleability of filamentous bulking sludge through the selective impediment of filamentous microorganisms. However, it is based on the declination of effluent water quality after actual chlorination in dairy wastewater treatment plant. In case of the activated sludge which was exposed in the suggested concentration of chlorine $7.5\;mgCl_2/gVSS/day$ for the filamentous bulking control, decrease of organic uptake rate of $4.9\~24.0\%$, and dentrification rate of $24.8\~30.3\%$ ware shown in comparison to the control group which was not reacted with chlorine. As a result of comparing floc size of activated sludge microorganism, the average of floc diameter in the chlorine exposed group was $150\;{\mu}m$, which displays $25\%$ decrease compared with the control group.

Treatment of Dairy Wastewater by the Combination of RBC and tapered Aeration (RBC와 점감포기조의 복합구성에 따른 유가공폐수 처리에 관한 연구)

  • Lee, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1733-1738
    • /
    • 2008
  • The treatment efficiency of rotating biological contactors (RBCs) for the high strength of dairy wastewater was investigated. Two different systems were conducted composing of a single RBC with tapered aeration reactors for the system A and a sequential RBCs following tapered aeration reactors for the system B. Experiments using dairy wastewater were conducted for 50 days period of time, in which hydraulic rates were maintained at the constant ratios of 346L per day and variable BOD concentrations were at the range from 1,358mg/L to 829mg/L, the $COD_{cr}$, concentration of the range were from 2,384mg/L to 1,329mg/L, the range of T-N concentrations was from 66mg/L to 38mg/L, and 50% of internal recycle and 50% of sludge return were performed. Results indicated that the removal efficiencies of the system B were higher than those of the system A. The removal efficiencies of system A for the BOD, $COD_{cr}$, T-N and T-P were 97.8%, 96.7%, 87.2% and 82%, respectively. The removal efficiencies of system B for the BOD, $COD_{cr}$, T-N and T-P were as of 98.5%, 98.5%, 91.3% and 89%.