• Title/Summary/Keyword: daily monitoring

Search Result 760, Processing Time 0.031 seconds

Heart Rate Measurement Combining Motion and Color Information

  • Lomaliza, Jean-Pierre;Park, Hanhoon;Moon, Kwang-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.11
    • /
    • pp.1388-1395
    • /
    • 2020
  • Daily monitoring of the heart rate can facilitate detection of heart-related diseases in their early stages. Therefore, providing an easy-to-use and noninvasive heart rate monitoring system has been a very popular research topic in the field of healthcare. One of good candidate methods is to use commonly available cameras and extract information that can help to estimate heart rate from a human face. Generally, such information can be retrieved using two different approaches: photoplethysmography (PPG) and ballistocardiography (BCG). PPG exploits slight color changes caused by blood volume variations during heartbeats; thus, it tends to be vulnerable to unstable lighting conditions. BCG exploits subtle head motions caused by pumped blood travelling through the carotid artery during heartbeats; thus, it is vulnerable to the voluntary head movements that are not related to heartbeats. Nevertheless, most related works use either to estimate the heart rate. In this paper, we propose to combine two approaches to be robust to challenging conditions. Specifically, we explore possible ways to combine raw signals obtained from two approaches and verify that the proposed combination shows better accuracies under challenging conditions, such as voluntary head movements and ambient lighting changes.

A study on an Ambulatory Monitoring of Vital Signs for Anxiety (휴대용 불안 증후 측정기 개발에 관한 연구)

  • 윤형로;김광준
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.235-242
    • /
    • 1991
  • This research has reported that the selection and assessment of treatment in anxiety disorders depend to a large extend on patient reports of somatic symptomatology. However, the correspondence between such reports and actual physiological data Is unknown as the physiological measures used were taken in laboratory. The purpose of the ambulatory momboring device is, therefore, to present for analysis physiological data derived from the sub jects during their daily activities. The physiological parameters of interest are heart rate, respiratory rate, skin conductance level/response, skin temperature, and activity level. This device had an microcomputer based data acquisition unit, Interfaced to it for the purpose of data collection. The data is collected usually over a period of 12 hours. The data from the ambulatory monitoring device can be used to assess the psychophysiology of anxiety in the field. The data from the device will also reveal if patients who report different sets of symptoms differ physiologically too. Thls will help physicians for the right kind of treatment and also solve the many uncertainties that have existed thus far in quantizing anxiety.

  • PDF

The Effects of a Preventive Tailored Early Intervention Program for the Quality of Parenting of Low Income Families (영아 어머니의 양육행동지원을 위한 맞춤형 예방 중재 프로그램 개발 및 효과: 저소득층을 중심으로)

  • Park, Shin-Jin;Lee, Young
    • Journal of the Korean Home Economics Association
    • /
    • v.49 no.6
    • /
    • pp.67-83
    • /
    • 2011
  • The purposes of this study were to a develop a preventive tailored early intervention program and to investigate the effects of the program on the quality of parenting for low income families. The subjects were eighty five infants, aged 13 to 32 months, and their mothers. Of the 85 mother-infant dyads, 42 dyads were randomly assigned to the experimental group and 43 dyads to the control group. To prevent the risks of the adverse development of infants from low income families a tailored intervention program was created based upon the transactional model. This emphasized the quality of the home environment and of the daily mother-infant interaction. The risk factors were assessed and progress monitoring was undertaken for the preventive tailored intervention treatment. In order to assess the effects of the program, HOME, the NCAST Teaching Scale and the Parenting Stress Index/Short From were used. The collected data were analyzed with descriptive statistics, ANCOVA, and the McNemar test. The experimental group showed a significant increase in performance and higher scores than the control group on the scores from HOME, and the NCAST Teaching Scale and significant decrease and lower scores in the Parenting Stress Index(SF).

Indoor Passive Location Tracking and Activity Monitoring using WSN for Ubiquitous Healthcare

  • Singh, Vinay Kumar;Lee, Seung-Chul;Lim, Hyo-Taek;Myllyla, Risto;Chung, Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.4
    • /
    • pp.382-388
    • /
    • 2007
  • Indoor location system using wireless sensor network technology was applied for the status evaluation and activity monitoring of elderly person or chronic invalid at home. Location awareness application is transparent to the daily activities, while providing the embedded computing infrastructure with an awareness of what is happening in this space. To locate an object, the active ceiling-mounted reference beacons were placed throughout the building. Reference beacons periodically publish location information on RF and ultrasonic signals to allow application running on mobile or static nodes to study and determine their physical location. Once object-carried passive listener receives the information, it subsequently determines it's location from reference beacons. By using only the sensor nodes without any external network infrastructure the cost of the system was reduced while the accuracy in our experiments. was fairly good and fine grained between 7 and 15 cm for location awareness in indoor environments. Passive architecture used here provides the security of the user privacy while at the server the privacy was secured by providing the authentication using Geopriv approach. This information from sensor nodes is further forwarded to base station where further computation is performed to determine the current position of object and several applications are enabled for context awareness.

Detecting Complex 3D Human Motions with Body Model Low-Rank Representation for Real-Time Smart Activity Monitoring System

  • Jalal, Ahmad;Kamal, Shaharyar;Kim, Dong-Seong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.3
    • /
    • pp.1189-1204
    • /
    • 2018
  • Detecting and capturing 3D human structures from the intensity-based image sequences is an inherently arguable problem, which attracted attention of several researchers especially in real-time activity recognition (Real-AR). These Real-AR systems have been significantly enhanced by using depth intensity sensors that gives maximum information, in spite of the fact that conventional Real-AR systems are using RGB video sensors. This study proposed a depth-based routine-logging Real-AR system to identify the daily human activity routines and to make these surroundings an intelligent living space. Our real-time routine-logging Real-AR system is categorized into two categories. The data collection with the use of a depth camera, feature extraction based on joint information and training/recognition of each activity. In-addition, the recognition mechanism locates, and pinpoints the learned activities and induces routine-logs. The evaluation applied on the depth datasets (self-annotated and MSRAction3D datasets) demonstrated that proposed system can achieve better recognition rates and robust as compare to state-of-the-art methods. Our Real-AR should be feasibly accessible and permanently used in behavior monitoring applications, humanoid-robot systems and e-medical therapy systems.

Distances of Type II-P Supernovae SN 2014cx and SN 2017eaw

  • Kim, Sophia;Im, Myungshin;Choi, Changsu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.31.3-32
    • /
    • 2018
  • Supernovae (SNe) are well known as good cosmological distance probes owing to their brightness. Specifically, type Ia SNe contribute greatly to our understanding of acceleration of cosmic expansion. However, type IIP supernovae are the most common type of SNe and have been found out to a large redshift, so the application of these SNe as distance indicators is promising. IMSNG is a project for monitoring nearby galaxies (<50Mpc) to catch early light curves of transients and get inspections of their progenitors. The daily monitoring observation allows us to construct a dense light curve of SNe, too. In this talk, we present the light curves of two SNe IIP, SN 2014cx (NGC337) and SN 2017eaw (NGC6946), using our IMSNG data. A newly developed technique, the Photometric Color Method (PCM), employs only photometric data to estimate distances for SNe IIP. We present the distances to our targets measured through PCM and compare this to that of obtained via other methods.

  • PDF

Affecting Factors on the Variation of Atmospheric Concentration of Polycyclic Aromatic Hydrocarbons in Central London

  • Baek, Sung-Ok;Roger Perry
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.E
    • /
    • pp.343-356
    • /
    • 1994
  • In this study, a statistical investigation was carried out for the evaluation of any relationship between polycyclic aromatic hydrocarbons (PAHss) associated with ambient aerosols and other air quality parameters under varying meteorological conditions. Daily measurements for PAHs and air quality/meteorological parameters were selected from a data-base constructed by a comprehensive air monitoring in London during 1985-1987. Correlation coefficients were calculated to examine any significant relationship between the PAHs and other individual variables. Statistical analysis was further Performed for the air quality/meteorological data set using a principal component analysis to derive important factors inherent in the interactions among the variables. A total of six components were identified, representing vehicle emission, photochemical activity/volatilization, space heating, atmospheric humidity, atmospheric stability, and wet deposition. It was found from a stepwise multiple regression analysis that the vehicle emission component is overall the most important factor contributing to the variability of PAHs concentrations at the monitoring site. The photochemical activity/volatilzation component appeared to be also an important factor particularly for the lower molecular weight PAHs. In general, the space heating component was found to be next important factor, while the contributions of other three components to the variance of each PAHs did not appear to be as much important as the first three components in most cases. However, a consistency for these components in their negative correlations with PAHs data was found, indicating their roles in the depletion of PAHs concentrations in the urban atmosphere.

  • PDF

Exposure Monitoring of Nonylphenol in Preterm Breast milk in Seoulers (서울 거주 산모의 초유 중 노닐페놀 분석을 통한 인체노출평가)

  • Yi, Bit-Na;Kim, Chang-Sung;Park, Mi-Jung;Han, Yu-Sok;Lee, So-Jung;Yan, Mi-Hi
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.2
    • /
    • pp.113-117
    • /
    • 2008
  • Biomonitoring of nonylphenol (NP), an endocrine disrupting chemical, is required in Korea to perform its proper regulation. Thus, we analyzed exposure levels of nonlyphenol (NP) in breast milk from the mothers who delivered babies within 10 days (N=325). We analyzed free and total forms of NP in breast milk with LC/MS/MS (LOD, 0.5 ppb). In addition, we obtained questionnaires concerning lifestyle from the subject. As results, ranges of total NP were ${\mu}g/L$ (median, $3.51{\pm}4.98{\mu}g/L$ vs. normal, N=281, $2.07{\pm}3.76{\mu}g/L$; p<0.05). In conclusion, we suggest that exposure monitoring of NP should be continuously performed, even though the risks of NP are not clear, yet.

An Assessment Study for the Urban Air Monitoring Network in Seoul (서울지역 도시대기측정망 평가 연구)

  • Ghim, Young Sung;Choi, Yongjoo;Park, Ji Soo;Kim, Chan Hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.504-509
    • /
    • 2014
  • Twenty-five stations of the urban monitoring network in Seoul were assessed with a focus on surveillance function of the exceedances of 8-hour ozone and 24-hour $PM_{10}$ standards. The two standards were selected because their attainment rates were particularly low. Two hierarchical cluster analyses were performed to group stations with similar atmospheric environments-one using daily highest 8-hour [$O_3+NO_2$], 8-hour $O_3$ concentrations plus corresponding 8-hour $NO_2$ concentrations considering the interconversion of $O_3$ and $NO_2$, and the other using 24-hour $PM_{10}$ concentrations. An index to measure higher concentration and exceedances of the standards was introduced. Within a cluster, sufficiently high score was assigned to the trends station or the station with higher index. Scores for $O_3+NO_2$ and $PM_{10}$ of a given station were added and ranked in the descending order to determine the relative importance.

Monitoring of Outlet Discharge and Water Quality from a Small Agricultural Reservoir (소규모 농업용 저수지의 통관 방류량 및 수질 측정)

  • Choi, Jin-Kyu;Son, Jae-Gwon;Koo, Ja-Woong;Yoon, Kwang-Sik;Kim, Young-Ju
    • Journal of Korean Society of Rural Planning
    • /
    • v.6 no.2 s.12
    • /
    • pp.73-81
    • /
    • 2000
  • This study was carried out to measure the amount of outlet discharge and analyse the water quality from an agricultural reservoir. Joongpyong reservoir was selected as the monitoring site. Daily discharge was determined by measured water level data of delivery canal and the stage-discharge relation curve. The measured water discharge through culvert outlet of Joongpyong reservoir was 593,200m3 which was equivalent to irrigation depth 1,186mm during irrigation period in 1999. And water samples were taken from the surface water of reservoir and delivery canal, periodically. Temporal variation of water quality constituents such as water temperature, pH, EC, total nitrogen, total phosphorus were investigated. The result showed that pH was ranged 6.9 7.8, total nitrogen 1.39 4.11mg/L, total phosphorus 0.007 0.036 mg/L, respectively.

  • PDF