• Title/Summary/Keyword: daily monitoring

Search Result 758, Processing Time 0.036 seconds

Spatio-Temporal Variations in Groundwater Recharge in the Jincheon Region (진천지역 지하수 함양량의 시공간적 변동특성)

  • Chung, Il-Moon;Na, Han-Na;Lee, Deok-Su;Kim, Nam-Won;Lee, Jeong-Woo;Lee, Jae-Myung
    • The Journal of Engineering Geology
    • /
    • v.21 no.4
    • /
    • pp.305-312
    • /
    • 2011
  • Because groundwater recharge shows spatial-temporal variability due to climatic conditions, it is necessary to investigate land use and hydrogeological heterogeneity, and estimate the spatial variability in the daily recharge rate based on an integrated surface-groundwater model. The integrated SWAT-MODFLOW model was applied to compute physically based daily groundwater recharge in the Jincheon region. The temporal variations in estimated recharge were calibrated using the observed groundwater head at several National Groundwater Monitoring Stations and at automatic groundwater-monitoring sites constructed during the Basic Groundwater Investigation Project (2009-2010). For the whole Mihocheon watershed, including the Jincheon region, the average groundwater recharge rate is estimated to be 20.8% of the total rainfall amount, which is in good agreement with the analytically estimated recharge rate. The proposed methodology will be a useful tool in the management of groundwater in Korea.

Monitoring and Risk Assessment of Pesticide Residues in Commercially Dried Vegetables

  • Seo, Young-Ho;Cho, Tae-Hee;Hong, Chae-Kyu;Kim, Mi-Sun;Cho, Sung-Ja;Park, Won-Hee;Hwang, In-Sook;Kim, Moo-Sang
    • Preventive Nutrition and Food Science
    • /
    • v.18 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • We tested for residual pesticide levels in dried vegetables in Seoul, Korea. A total of 100 samples of 13 different types of agricultural products were analyzed by a gas chromatography-nitrogen phosphate detector (GC-NPD), an electron capture detector (GC-${\mu}ECD$), a mass spectrometry detector (GC-MSD), and a high performance liquid chromatography- ultraviolet detector (HPLC-UV). We used multi-analysis methods to analyze for 253 different pesticide types. Among the selected agricultural products, residual pesticides were detected in 11 samples, of which 2 samples (2.0%) exceeded the Korea Maximum Residue limits (MRLs). We detected pesticide residue in 6 of 9 analyzed dried pepper leaves and 1 sample exceeded the Korea MRLs. Data obtained were then used for estimating the potential health risks associated with the exposures to these pesticides. The estimated daily intakes (EDIs) range from 0.1% of the acceptable daily intake (ADI) for bifenthrin to 8.4% of the ADI for cadusafos. The most critical commodity is cadusafos in chwinamul, contributing 8.4% to the hazard index (HI). This results show that the detected pesticides could not be considered a serious public health problem. Nevertheless, an investigation into continuous monitoring is recommended.

Damage detection of a cable-stayed bridge based on the variation of stay cable forces eliminating environmental temperature effects

  • Chen, Chien-Chou;Wu, Wen-Hwa;Liu, Chun-Yan;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.859-880
    • /
    • 2016
  • This study aims to establish an effective methodology for the detection of instant damages occurred in cable-stayed bridges with the measurements of cable vibration and structural temperatures. A transfer coefficient for the daily temperature variation and another for the long-term temperature variation are firstly determined to eliminate the environmental temperature effects from the cable force variation. Several thresholds corresponding to different levels of exceedance probability are then obtained to decide four upper criteria and four lower criteria for damage detection. With these criteria, the monitoring data for three stay cables of Ai-Lan Bridge are analyzed and compared to verify the proposed damage detection methodology. The simulated results to consider various damage scenarios unambiguously indicate that the damages with cable force changes larger than ${\pm}1%$ can be confidently detected. As for the required time to detect damage, it is found that the cases with ${\pm}2%$ of cable force change can be discovered in no more than 6 hours and those with ${\pm}1.5%$ of cable force change can be identified in at most 9 hours. This methodology is also investigated for more lightly monitored cases where only the air temperature measurement is available. Under such circumstances, the damages with cable force changes larger than ${\pm}1.5%$ can be detected within 12 hours. Even though not exhaustively reflecting the environmental temperature effects on the cable force variation, both the effective temperature and the air temperature can be considered as valid indices to eliminate these effects at high and low monitoring costs.

Patterns of Astronomical Seeing at KSA SEM Observatory (한국과학영재학교 천지인 천문대의 천문학적 시상 패턴)

  • Kang, Im-Seok;Lee, Kyung-Hoon
    • Journal of the Korean earth science society
    • /
    • v.30 no.4
    • /
    • pp.485-494
    • /
    • 2009
  • We report patterns of astronomical seeing at KSA SEMO (Korea Science Academy Space Earth and Man Observatory). Though the data of the seeing measured at the local observatory is essential in identifying the seeing of the observatory, systematic measurement of seeing has not been made in Pusan yet. For this reason, KSA SEMO adopted the Santa Barbara Instrument Group (SBIG) Seeing Monitor to constantly record the seeing. The seeing monitoring was done through an elaborate procedure involving direct CCD images in the focal plane which were subsequently analyzed for the full width at half maximum (FWHM) Gaussian widths. Based on the seeing monitoring for 8 months, we classified five patterns of the seeing at KSA SEMO: 'Sunset/Sunrise Effect', 'Extreme Fluctuation', 'Sudden Increment', 'Daily Variation' and 'Stable Condition'. Seeing was generally good from 1:00 am to 3:00 am than other times, and it was also better in Winter than in Summer.

Implementation of RFID System using Wireless Sensor Networks (무선 센서 네트워크를 이용한 RFID 시스템 구현)

  • Jung, Kyung-Kwon;Lee, Seung-Joon;Lee, Chang-Won;Nghia, Truong Van;Chung, Sung-Boo;Eom, Ki-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.858-861
    • /
    • 2011
  • In this paper, we present a RFID system by using a wireless sensor network. The proposed system is installed in glove for activity monitoring. The RFID reader, to send data by using sensor network platform and RFID tag are small size, the shape of quadrangle, and operate in the frequency of 13.56 MHz. The sensor node can read RFID tags on the various objects used in daily living such as furniture, medicines, and kitchenwares. The sensor node reads the data of RFID tags, it transmits wireless packets to the sink node. The sink node sends the received packet immediately to a server system. The data from each RFID system is collected into a database, and then the data are processed to visualize the measurement of daily living activities of users. We provide a web-based monitoring system, and can see the number of RFID tag readings per day as bar charts. The result of experiments demonstrates that the way we propose can help to check the situation of life for people who live alone.

  • PDF

Monitoring and Risk Assessment of Pesticide Residues in Pre-harvest Fresh Ginseng (Panax ginseng C. A. Meyer) in Chungbuk Province in 2019 (충북지역 생산단계 수삼 중 잔류농약 모니터링 및 위해성 평가(2019))

  • Song, Tae Hwa;Lee, Young Wook;Youn, Taek Han;Park, Eun A;Shim, Eun Sun;Lee, Ju Hee;Kyung, Kee Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.2
    • /
    • pp.118-126
    • /
    • 2021
  • BACKGROUND: It is very important to monitor the residual characteristics of pesticides in pre-harvest fresh ginseng to ensure consumer safety. METHODS AND RESULTS: Forty-eight fresh ginseng samples were collected from 8 ginseng-growing fields 10 days before harvest and pesticide residues in fresh ginseng with and without rhizome (head of ginseng) and rhizome were analyzed for 320 pesticides by using GC-MS/MS and LC-MS/MS. As a result of the pesticide residue analysis, the number of pesticides detected from the fresh ginseng with rhizome, that without rhizome and rhizome were 26, 25, and 40, respectively, indicating that high number of pesticides found in rhizome, compared with the other parts. Pyraclostrobin was detected with the highest frequency in all samples, reaching to 21.2% in fresh ginseng with rhizome, 16.8% in that without rhizome, and 14.8% in rhizome. CONCLUSION: The residue levels of pesticides detected did not exceed their maximum residue limits, in spite of residual data in fresh ginseng before harvest. The amounts of the estimated daily intakes of all the detected pesticides were found to be from 0.018 to 1.818% of their acceptable daily intakes, indicating that concentrations of pesticides detected from fresh ginseng with and without rhizome collected before harvest do not pose the immediate health risks.

Assessment of PM-10 Monitoring Stations in Daegu using GIS Interpolation (공간 보간법을 이용한 도시지역 미세먼지 측정소의 배치 적절성 평가)

  • Kim, Hyo-Jeong;Jo, Wan-Kuen
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.2
    • /
    • pp.3-13
    • /
    • 2012
  • This study evaluated the feasibility of the location for PM-10 Monitoring Stations utilizing through GIS analysis. In addition, optimal sites were investigated to properly manage PM-10 which are closely related with public health. There are 11 PM-10 monitoring stations in Daegu area and the PM-10 data monitored at these stations are utilized to understand the overall status of PM-10 pollution. However, there are contrastive issues on the locations of current monitoring stations. Thus, this study prepared the map of PM-10 concentrations in Daegu area using IDW and Kriging techniques. Furthermore, average PM-10 concentrations were calculated using zonal statistical methods according to legal divisions and then, the current monitoring stations were evaluated whether their location is appropriate or not for PM-10 pollution distribution. It was found that, on the basis of yearly, seasonal and daily concentration analysis, the location of current PM-10 monitoring stations were not appropriate, particularly as they could not represent regional PM-10 pollution characteristics. In order to supplement this deficiency, seven sites(Namsandong, Namildong, Dongildong, Buksungro 1, Jongro 1, Hyangchondong and Haejeondong) commonly selected from each analytical step are suggested as additional PM-10 monitoring sites. It is further suggested that this kind of scientific evaluation for the location of PM-10 monitoring stations are needed in order to properly manage public heath in other cities as well as Daegu area.

Analysis of a Weak Zone in Embankment Close to a Drainage using Resistivity Monitoring Data (전기비저항 모니터링을 이용한 저수지 제체 취수시설 취약성 해석)

  • Lim, Sung Keun
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.1
    • /
    • pp.8-14
    • /
    • 2018
  • For the purpose of maintenance and prevention of earth fill dams against damage from natural hazards, automatic monitoring through various measuring instruments and resistivity survey has been carried out. Reservoirs and embankments have the structural vulnerability on the agricultural usages since most of them were built more than thirty years ago. The main aim to use monitoring method is to verify the safety and integrity of the dam. Resistivity survey can detect potential weaknesses, such as defective zones, anomalous seepages or internal erosion processes. Permanent resistivity monitoring systems were installed at a reservoir, which daily measurements have been taken every 6 hour. Using monitoring data for one year, anomalous seepage and structural defects were clarified for dam safety. Annual water level fluctuations are around 10 m. During their operation, reservoir dams are subject to a never-ending hydraulic load from the reservoir, which over the years may cause changes in the properties of the inner parts of the dam construction. Detailed analysis of the monitoring results was performed and showed that resistivities at most locations have been very stable over the full monitoring period excluding the effects of water fluctuation and seasons. To investigate the detectability of weak zone using the DC resistivity monitoring, numerical modeling with a simplified model for the drainage at a reservoir dam was also performed. The results showed that the seepage zone near drainage in a reservoir dam could be detected by resistivity response change.

Monitoring Pig Body Temperature Using Infrared Sensors

  • Jang, Jin Cheol;Lee, Min Ho;Lee, Jun Yeop;Choi, Hee Chul;Choi, Dong Yun;Kim, Hyeok Ju;Kim, Hyeon Tae
    • Journal of Biosystems Engineering
    • /
    • v.40 no.4
    • /
    • pp.368-372
    • /
    • 2015
  • Purpose: The purpose of this study is to verify the feasibility of using an infrared sensor to measure the body temperature of a sow. We first conducted experiments on three pigs by using three infrared sensors and one indoor temperature sensor. Methods: The three infrared sensors were installed inside our model house and were used to take temperature measurements per second of the backs of the pigs. While feeding, the temperatures of the backs of the pigs were measured at distances of 10 cm, 20 cm, and 30 cm from the infrared sensors. Results: We concluded that the relation between the temperature of the pigs' backs and the indoor temperature was y =0.549x + 18.459 at a measuring distance of 30 cm. The relation was y = 0.645x + 15.461 for a distance of 20 cm and y = 0.760x + 11.913 for a distance of 10 cm. We found high correlation between the indoor temperature and the temperature of the pigs' backs. Conclusions: It is possible to use an infrared thermometer to monitor the temperature of pigs' backs. This system seems to be feasible and effective in monitoring pig temperature. The use of an infrared thermometer will also make daily monitoring easy. In later experiments, the possibility of developing a system that can determine if an error can be corrected by using infrared sensor is explored by considering humidity variables.

Evaluation of Drought Monitoring Using Satellite Precipitation for Un-gaged Basins (미계측지역의 위성강우 기반 가뭄감시 평가)

  • Jang, Sangmin;Yoon, Sunkwon;Lee, Seongkyu;Lee, Taehwa;Park, Kyungwon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.55-63
    • /
    • 2018
  • This study analyzed the applications of near real-time drought monitoring using satellite rainfall for the Korean Peninsula and un-gaged basins. We used AWS data of Yongdam-Dam, Hoengseong-Dam in Korea area, the meteorological station of Nakhon Rachasima, Pak chong for test-bed to evaluate the validation and the opportunity for un-gaged basins. In addition, we calculated EDI (Effective doought index) using the stations and co-located PERSIANN-CDR, TRMM (Tropical Rainfall Measurement Mission) TMPA (The TRMM Multisatellite Precipitation Analysis), GPM IMERG (the integrated Multi-satellitE Retrievals for GPM) rainfall data and compared the EDI-based station data with satellite data for applications of drought monitoring. The results showed that the correlation coefficient and the determination coefficient were 0.830 and 0.914 in Yongdam-dam, and 0.689 and 0.835 in Hoengseng-Dam respectively. Also, the correlation coefficient were 0.830, 0.914 from TRMM TMPA datasets and compasion with 0.660, 0.660 based on PERSIANN-CDR and TRMM data in nakhon and pakchong station. Our results were confirmed possibility of near real-time drought monitoring using EDI with daily satellite rainfall for un-gaged basins.