• 제목/요약/키워드: daily average air temperature

검색결과 123건 처리시간 0.028초

여수항의 평균 열플럭스 (Mean Heat Flux at the Port of Yeosu)

  • 최용규;양준혁
    • 한국환경과학회지
    • /
    • 제15권7호
    • /
    • pp.653-657
    • /
    • 2006
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) data from National Fisheries Research and Development Institute (NFRDI) (1995-2004), mean heat fluxes were estimated at the port of Yeosu. Net heat flux was transported from the air to the sea surface during February to September, and it amounts to $205 Wm^{-2}$ in daily average value in May. During October to January, the transfer of net heat flux was conversed from the sea surface to the air with $-70 Wm^{-2}$ in minimum of daily average value in December. Short wave radiation was ranged from $167 Wm^{-2}$ in December to $300 Wm^{-2}$ in April. Long wave radiation (Sensible heat) was ranged from $27 (-14) Wm^{-2}$ in July to $90 (79) Wm^{-2}$ in December. Latent heat showed $42 Wm^{-2}$ with its minimum in July and $104 Wm^{-2}$ with its maximum in October in daily average value.

평면식 태양열집열기를 이용한 곡물 건조개선에 관한 연구 (A Study on the Performance of Flat-plate Solar Air Collector and its Application to Grain Drying)

  • 민영봉;최규홍
    • Journal of Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.114-125
    • /
    • 1978
  • The use of petroleum fuels in grain drying causes problems of high cost and management. To solve these problems, it is required to study on soLar energy as an alternative to petroleum fuels for grain drying. The purposes of this study were to find out the optimum received area and air flow rate of a flat-plate solar air collector for grain drying and to assess its effects on grain drying with a small grain bin. The results of this study are summarized as follows ; 1. The calculated optimum tilt angles of the collector in the summer and autumn drying seasons were 20 and 50 degress, respectively, in suwon area. 2. The outlet temperature of the collector was $36^\circ C$ on the daily average with the maximum of $36^\circ C$ at 12:00 o clock. Solar radiation on the collector surface was 1.04 ly( 1 langley = 1 cal/$cm^2$) per minute on the daily average and 1.30 ly per minute on the maximum at 11:00am. The thermal efficiency of the collector was 62.4 percent on the daily average, and the air flow-rate per unit receiving are was 1.03 $m^3$/min/$m^2$.4. The calculated optimum receiving area and the air flow-rate per unit cubic volume for paddy in autumn drying season was 2 $m^2$ and 2$m^3$/min , respectively. 5. not significantly difference in the collector efficiency was appeared between the rotating and fixed type of solar collector. 6. For drying of wheat with 0.6 meter of the depth in the bin, approximately 9 hours were required to reduce the moisture content from 21.6% to 13% with air follow rate of 5 $m^3$/min an initial moisture per cubic meter of wheat and with air temperature of $52^\circ C$. 7. In the drying test of rough rice with a turning operation in a grain bin approximately 21 hours were required to reduced the moisture from 21% to 14.5% with airflow rate of 2 $m^3$/min per cubic meter of rice and the air temperature of $43.5^\circ C$. 8. Over-drying at the bottom and less -drying at the top of the grain mass was resulted from the high -temperature of drying air which was obtained from the flat-plate solar collector in this test. An appropriate operation should be prepared for the uniform moisture of the grain in the bin.

  • PDF

현장계측 데이터를 이용한 일평균 대기온도 산정방법과 동상방지층 설계를 위한 동결지수 보정 (Computing Procedure of Daily Average Air Temperature using Field Data and Frost Index Calibration for Anti-Frost Heave Layer Design)

  • 조명환;김낙석;심재필
    • 대한토목학회논문집
    • /
    • 제31권3D호
    • /
    • pp.433-439
    • /
    • 2011
  • 도로의 동상방지층을 설치하기 위하여 동결심도(동결관입깊이)를 산정하는데, 동결지수는 $0^{\circ}C$ 이하의 기온과 영하온도의 지속시간을 곱한 값을 연간을 통하여 누계한 수치로 표시된다. 따라서, 일평균 대기 온도를 구하는 방법이 동결지수에 영향을 미칠 수 있다. 기상청의 경우 1999년을 기점으로 이전에는 1일 4회 평균 대기온도 제공하였으며, 현재는 1일 8회 평균 대기온도를 제공하고 있다. 본 연구에서는 이러한 일평균 대기온도를 산정하는 방법이 동결지수의 산정결과에 미치는 영향을 확인하기 위하여 한반도 남부(동결지수 $350^{\circ}C{\cdot}$일 미만) 6개 지역을 현장조건(저성토부, 절성경계부 및 절토부)에 따라 구분하여 15개소에 대하여 현장계측시스템을 구축하였다. 그리고 현장계측시스템으로부터 얻어진 대기온도를 통하여 동결지수를 산정하고 상호 비교분석 하였다. 비교분석 결과 일반적으로 1일 4회 평균 대기온도를 사용한 경우가 1일 8회 평균 대기온도를 사용하는 경우보다 약 3% 전후 큰 것으로 나타났으며, 본 연구 지역에 대한 동결지수를 결정할 때 동결지수를 보정할 수 있는 보정식을 제안하였다.

Temperature Change in the Largest Industrial City, Korea

  • Lee, Byeong-Kyu;Lee, Sang-Tae
    • Asian Journal of Atmospheric Environment
    • /
    • 제9권3호
    • /
    • pp.194-204
    • /
    • 2015
  • This study analyzed a change trend of ambient temperature over the last sixty years in the largest industrial city in Korea, Ulsan. Linear warming rates in Ulsan over the last 25 (1985 to 2009), 40 (1970 to 2009), and 60 (1950 to 2009) years were 0.0507, 0.0416, and $0.0277^{\circ}C/yr$, respectively. The annual average temperature (AAT) and the annual average of the daily lowest temperature (AADLT) in Ulsan increased 1.3 and $2.9^{\circ}C$, respectively, over the last fifty years (1960 to 2009). The increasing slopes of the AAT and AADLT over the fifty years in Ulsan were higher or much higher than those in neighboring cities and on a global scale. In the comparison analysis of daily average temperature over the most recent ten years, the highest ($15.9^{\circ}C$) was observed in the industrial area followed by the downtown, coastal, suburban, and rural areas with 14.6, 14.5, 14.0, and $12.8^{\circ}C$, respectively. The number of cold days less than $5.0^{\circ}C$ decreased, while the number of hot days higher than $20.0^{\circ}C$ increased. The decreasing slopes in the cold days in lower latitude cities were steeper than those in higher latitude cities in Korea.

연간 건물난방 에너지사용량의 예측에 미치는 측정기간의 영향 (Effect of Measuring Period on Predicting the Annual Heating Energy Consumption for Building)

  • 조성환;태춘섭;김진호;방기영
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.287-293
    • /
    • 2003
  • This study examined the temperature-dependent regression model of energy consumption based on various measuring period. The methodology employed was to construct temperature-dependent linear regression model of daily energy consumption from one day to three months data-sets and to compare the annual heating energy consumption predicted by these models with actual annual heating energy consumption. Heating energy consumption from a building in Daejon was examined experimentally. From the results, predicted value based on one day experimental data can have error over 100%. But predicted value based on one week experimental data showed error over 30%. And predicted value based on over three months experimental data provides accurate prediction within 6% but it will be required very expensive.

Effect of regional climatic conditions, air pollutants, and season on the occurrence and severity of injury in trauma patients

  • ;;;;;김훈
    • 대한응급의학회지
    • /
    • 제29권6호
    • /
    • pp.603-615
    • /
    • 2018
  • Objective: We analyzed the association between regional weather and temporal changes on the daily occurrence of trauma emergencies and their severity. Methods: In this cross-sectional prospective study, we investigated daily atmospheric patterns in trauma episodes in 1,344 patients in Cheongju city, South Korea, from January 2016 to December 2016 and analyzed the association of trauma occurrence and Injury Severity Scores (ISS) with weather conditions on a daily scale. Results: The mean age of trauma patients was $53.0{\pm}23.8years$ and average ISS was $9.0{\pm}2.0$. Incidence of trauma was positively correlated with average temperature (r=0.512, P<0.001) and atmospheric pressure (r=0.332, P=0.010) and negatively correlated with air pollutants (particulate matter less than $2.5{\mu}m^3$ [PM2.5], r=-0.629, P<0.001; particulate matter less than $10{\mu}m^3$ [PM10], r=-0.679, P<0.001). ISS was not significantly correlated with climate parameters and air pollutants, and variability was observed in the frequency and severity of trauma by time of day (highest occurrence, 16-20 pm; highest ISS, 4-8 am), day of the week (highest occurrence and highest ISS, Saturday), month of the year (highest occurrence, July; highest ISS, November), and season (highest incidence, summer; highest ISS, autumn). Conclusion: The study shows a positive relationship between trauma occurrence and specific weather conditions, such as atmospheric temperature and pressure. There was a negative relationship between concentrations of PM2.5 or PM10, and trauma occurrence. However, no correlation was observed between weather conditions or the concentrations of air pollutants and ISS. In addition, seasonal, circaseptan, and circadian variations exist in trauma occurrence and severity. Thus, we suggest that evaluation of a larger, population-based data set is needed to further investigate and confirm these relationships.

1월 일최저기온 평균을 이용한 한국의 재현기간별 일 최저기온 극값 예측 (Estimation of the Periodic Extremes of Minimum Air Temperature Using January Mean of Daily Minimum Air Temperature in Korea)

  • 문경환;손인창;서형호;최경산
    • 한국농림기상학회지
    • /
    • 제14권4호
    • /
    • pp.155-160
    • /
    • 2012
  • 이 연구는 1월 일 최저기온의 평균을 이용하여 재현기간별 일 최저기온의 극값을 예측하는 방법을 개발하기 위해서 수행되었다. 전국 61개 기상관서의 1961~2010년의 50년 간의 일 최저기온자료를 이용하여 전체 연구를 수행하였다. 1월의 일 최저기온의 분포는 대부분 정규분포를 나타내고 있어, 이는 평균과 표준편차로부터 일 최저기온을 확률적인 기댓값으로 예측될 수 있었다. 이를 위하여 일 최저기온평균으로부터 일 최저기온의 표준편차의 변이를 추정하는 2차식을 개발하였다. 과거 10, 20, 30, 40, 50년의 재현 기간별로 관측된 일 최저기온의 평균, 표준편차, 극값을 분석하여 재현기간별 극값을 예측할 수 있는 계수를 도입하였고, 이 계수를 재현기간별로 추정할 수 있는 로그함수식도 개발하였다. 이 방법을 이용하여 과거 두 기간의 30년 자료를 이용하여 61개 지점에 대해 검증하였는데 평균 $1.1^{\circ}C$, 최대 $5.3^{\circ}C$의 오차를 가지고 과거 30년 재현기간의 일 최저기온의 극값을 예측할 수 있었다.

Variations of Soil Temperatures in Winter and Spring at a High Elevation Area (Boulder, Colorado)

  • Lee, Jin-Yong;Lim, Hyoun Soo;Yoon, Ho Il;Kim, Poongsung
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권5호
    • /
    • pp.16-25
    • /
    • 2015
  • The City of Boulder is located at an average elevation of 1,655 m (5,430 feet), the foothills of the Rocky Mountains in Colorado. Its daily air temperature is much varying and snow is very frequent and heavy even in spring. This paper examines characteristics of shallow (surface and depth = 10 cm) soil temperatures measured from January to May 2015 in the high elevation city Boulder, Colorado. The surface soil temperature quickly responded to the air temperature with the strongest periodicity of 1 day while the subsurface soil temperatures showed a less correlation and delayed response with that. The short-time Fourier of the soil temperatures uncovered their very low frequencies characteristics in heavy snow days while it revealed high frequencies of their variations in warm spring season. The daily minimum air temperature exhibited high cross-correlations with the soil temperatures without lags unlike the maximum air temperature, which is derived from its higher and longer auto-correlation and stronger spectrums of low frequencies than the maximum air temperature. The snow depth showed an inverse relationship with the soil temperature variations due to snow's low thermal conductivity and high albedo. Multiple regression for the soil temperatures using the air temperature and snow depth presented its predicting possibility of them even though the multiple r2 of the regression is not that much satisfactory (r2 = 0.35-0.64).

온실에서의 꽈리고추 소비수량 (Water Consumption of Twisted Sweet Pepper in Greenhouse)

  • 윤용철;이근후;서원명
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.217-223
    • /
    • 1998
  • This study was performed to figure out water consumption of the twisted sweet pepper in a greenhouse. Obtained results are as follows; 1. The ambient temperature was nearly same as the normal year, while the average air temperature and the relative humidity in the green house were little bit higher than those of the outside condition. The transparency of the greenhouse roof was approximately 50%. The total amount of rainfall during the irrigation period was 1,040㎜ which is 350㎜ higher than 1997 during the same period. 2. In case of pot cultivation, as the saturation ratio was increased, the aeaf area and plant height and yield were also increased. The yield from the field cultivation was higher than the average yield from the pot cultivations which are treated by three levels of saturation ratio. 3. The variation of daily consumptive use of the twisted sweet pepper was very large in it's range. In case of the pot cultivation, as the saturation was increased, the daily and the total consumptive use were increased. 4. The daily consumptive use was strongly correlated with the ambient temperature, while it was weakly correlated with the relative humidity and solar radiation. 5. There were close correlation between plant environment; leaf area, plant height and yield, and consumptive use. As the saturation ratio was increased, the correlation between those plant factors and consumptive use was getting stronger.

  • PDF

여름철 도시의 일상생활에서 경험하는 환경온도와 온냉감 평가 (24 hours' Exposed Temperature and Thermal Comfort in Summer)

  • 전정윤;이민정
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.51-56
    • /
    • 2003
  • All the outdoor and indoor spaces are connected with each other. The human being moves toward those spaces with temperature fluctuation between the natural and artificial temperature. We conducted an experiment which subjects were wearing the data logger in urban life, and measured 24 hours' exposed temperature and thermal comfort in summer. Results were as follows. 1. Subjects controls their micro climate like this. Most of them(84.6%) get weather information. Fashion(46.2%) and weather(30.8%) are the reasons to select clothes. They spend their time in indoor environment for 84.92% hours of a day and have an air-conditioner(61.5%) in their houses. 2. Temperature fluctuation which subjects were exposed for 24 hours were from 15.6$^{\circ}C$ to 33.8$^{\circ}C$ and average fluctuation was 9.02$^{\circ}C$. The median value of experienced temperature were 26-26.5$^{\circ}C$ and average temperature was 26.18$^{\circ}C$. They experienced cold shock of 3.96 times in a day.