• 제목/요약/키워드: cyclic sorption

검색결과 7건 처리시간 0.021초

건습이 반복되는 환경하의 해양콘크리트 구조물에 대한 염소이온 침투 해석 (Analysis of Chloride Ion Penetraion for Marine Concrete Structure with Cyclic Humidity Environment)

  • 한상훈
    • Ocean and Polar Research
    • /
    • 제26권1호
    • /
    • pp.43-50
    • /
    • 2004
  • The diffusion model, which considers diffusion and sorption, is proposed. The FEM program developed on the basis of the diffusion model provides the estimation of chloride concentration according to cyclic humidity and sorption. After the humidity diffusion analysis is carried out, the chloride ion diffusion and sorption analysis are conducted on the basis of the preestimated humidity data in each element. Each element has different analysis variables at different ages and locations. At early ages, the difference between inner and outer relative humidity causes the chloride ion penetration by sorption. As the humidity diffusion reduces the difference with age, the effect of sorption on the chloride ion penetration decreases. By the way, the cyclic humidity increases the effect of sorption on the chloride ion penetration at early ages, and the quantity of chloride ion around steel at later ages. Therefore, the in situ analysis of chloride ion penetration for marine concrete structures must be performed considering the cyclic humidity condition and the long term sorption.

Comparison of Dynamic Sorption and Hygroexpansion of Wood by Different Cyclic Hygrothermal Changing Effects

  • Yang, Tiantian;Ma, Erni
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권2호
    • /
    • pp.191-203
    • /
    • 2016
  • To investigate the dynamic sorptive and hygroexpansive behaviors of wood by different cyclic hygrothermal changing effects, poplar (populus euramericana Cv.) specimens, were exposed to dynamic sorption processes where relative humidity (RH) and temperature changed simultaneously in sinusoidal waves at 75-45% and $5-35^{\circ}C$ (condition A) and where RH changed sinusoidally at 75-45% but temperature was controlled at $20^{\circ}C$ (condition B), both for three cyclic periods of 1, 6, and 24 h. Moisture and dimensional changes measured during the cycling gave the following results: Moisture and transverse dimensional changes were generally sinusoidal. Moisture and dimensional amplitude increased with increasing cyclic period but all were lower for thicker specimens. The amplitude ratio of condition A to condition B ranged from 1.0 to 1.6 with the maximum value of 1.57 occurring at the shortest cyclic period, not as much as expected. T/R increased as cyclic period increased or specimen thickness decreased. T/R from condition B was weaker than that from condition A. Sorption and swelling hysteresis existed in both conditions. Sorption hysteresis was negatively related to cyclic period but in positive correlation with specimen thickness. Sorption hysteresis was found more obvious in condition B, while moisture sorption coefficient and humidity expansion coefficient showed the opposite results.

항만 콘크리트 구조물의 현장환경변화에 따른 염소이온 침투해석 (Analysis of Chloride Ion Penetration for Harbor Concrete Structure with In-situation Environment)

  • 한상훈;장인성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.225-228
    • /
    • 2004
  • In order to estimate the chloride ion penetration, the model, which considers diffusion and sorption, is proposed on the basis of Finite Element Method (FEM). The FEM program provides the estimation of chloride concentration according to cyclic humidity and sorption. After the humidity diffusion analysis is carried out, the chloride ion diffusion and sorption analysis are conducted on the basis of the preestimated humidity data in each element. Each element has different analysis variables at different ages and locations. At early ages and constant outer humidity, the difference between inner and outer relative humidity causes the chloride ion penetration by sorption. As the humidity diffusion reduces the difference with age, the effect of sorption on the chloride ion penetration decreases. By the way, the cyclic humidity increases the effect of sorption on the chloride ion penetration at early ages, and the quantity of chloride ion around steel at later ages. Therefore, the in-situ analysis of chloride ion penetration for marine concrete structures must be performed considering the cyclic humidity condition and the long term sorption.

  • PDF

현장 항만 콘크리트 구조물에 대한 염소이온 침투 해석 (Analysis of Chloride ion Penetration for In-Situation Harbor Concrete Structures)

  • 한상훈
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.751-760
    • /
    • 2005
  • 본 논문에서는 확산과 수분이동에 의한 침투를 함께 고려할 수 있는 염소이온침투 모델을 제시하고 이를 바탕으로 유한요소 프로그램을 개발한다. 개발된 프로그램을 이용하여 습도와 온도가 연속적으로 변화하는 현장상태에 대한 염소이온 침투 해석을 수행한다. 해석과정으로 먼저 수분확산해석을 수행한다. 이 해석에 의한 각 유한요소의 상대습도를 바탕으로 염소이온 침투해석을 위한 재료상수를 구한다. 이러한 재료상수를 이용하여 염소이온 침투해석을 수행하게 된다. 각 유한요소들은 시간과 재령에 따라 연속적으로 변화하는 재료상수 값을 가지게 된다. 내외부의 상대습도 차이가 크면 수분이동에 의한 염소이온 침투의 영향이 커지지만 내외부의 상대습도의 차이는 수분확산에 의해서 재령에 따라 감소하므로 수분이동에 의한 염소이온 침투의 영향은 재령에 따라 감소한다. 반복 습윤은 수분이동에 의한 염소이온 침투의 영향을 증가시켜 철근 주위의 염소이온 농도를 커지게 한다. 현장상황과 같이 건습의 반복이 장기적으로 발생하게 되면 수착과 확산을 함께 고려한 염소이온 침투량이 수분이동을 고려하지 않은 염소이온 침투량보다 매우 크다. 따라서, 항만 콘크리트 구조물에 대한 염소이온 침투해석을 장기재령동안 수행할 경우에는 수분이동 메커니즘을 포함한 수치 모델링을 바탕으로 건습의 반복을 고려하여 해석을 수행하는 것이 해석의 오차를 줄일 수 있을 것이다.

Sorption-enhanced reforming of tar: Influence of the preparation method of CO2 absorbent

  • Xie, Huaqing;Zhang, Weidong;Zhao, Xiangnan;Chen, Hao;Yu, Qingbo;Qin, Qin
    • Korean Journal of Chemical Engineering
    • /
    • 제35권11호
    • /
    • pp.2191-2197
    • /
    • 2018
  • To remove tar and produce environment-friendly $H_2$, one of the promising routes is the sorption-enhanced steam reforming (SESR) process, in which the $CO_2$ sorbent is a key element. We prepared the $CO_2$ sorbents with $Ca_{12}Al_{14}O_{33}$ as carrier with various methods. Their characterizations were examined, and the sample prepared by solgel (SG) method showed the strongest CaO and $Ca_{12}Al_{14}O_{33}$ phases and the most excellent pore structure among all the samples. Then, a thermogravimetric experiment was conducted, and the results showed that the sample prepared by sol-gel (SG) method had the best $CO_2$ adsorption capacity and excellent long-term cyclic stability. Finally, the sorbent was used into the steam reforming experiments of tar. Under the action of the sorbent, the reforming reaction was enhanced in-situ, with the $H_2$ yield and concentration improved obviously, and especially, $H_2$ concentration can reach over 98.85%.

촉진열화목재의 흡습성과 초음파전달속도 (Moisture Sorption and Ultrasonic Velocity of Artificially Weathered Sitka Spruce)

  • 강호양;박상진;김영숙
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권1호
    • /
    • pp.18-24
    • /
    • 2002
  • 시트카스프루스 50×133×10 mm3 시편을 340 mm 제논광과 주기적 강우장치를 갖춘 장치 내에서 촉진열화 시켰다. 시편은 자외선만 조사하거나 자외선을 조사하면서 동시에 강우를 병행하였으며 처리시간도 10시간과 20시간으로 구분하였다. 촉진열화 처리재의 물리적 성질을 색도, 흡습성 그리고 초음파 전달속도를 측정하여 조사하였다. 자외선 조사시간이 길수록 표면 명도가 낮아졌다. 강우처리는 표면 명도의 감소를 촉진하였으며 흡습성을 증가시켰다. 자외선과 강우 병행 처리재 중에 10시간 처리재의 흡습성이 20시간 처리재보다 높았는데 이는 20시간 처리재의 표면이 과도하게 열화된 때문일 가능성이 있다. 촉진열화 처리재의 초음파 전달속도는 무처리재보다 높았는데 이는 촉진열화에 의해 목재의 탄성계수가 높아졌거나 밀도가 감소했다고 할 수 있다.

전기적 흡 . 탕착에 의한 제염폐액의 정화처리기술 (The Purification of Decontamination Liquid Waste by Electrosorption)

  • 정종헌;문제권;김규남;이성호;이상문
    • 자원리싸이클링
    • /
    • 제8권3호
    • /
    • pp.18-25
    • /
    • 1999
  • 화학제염이나 전지화학제염을 통해 발생된 방사성 폐액을 정화처리할 수 있는 새로운 방법으로, 다공성 활성탄소섬유(ACF)상에서 폐액중 코발트이온의 전기적 흡·탈착에 대한 연구를 수행하였다. 회전원판 전극을 사용하여 순환전압전류법으로 전기이중층 충전만이 발생하는 전위 영역을 조사하였다. ACF 전극을 사용한 회분식 전기흡착 실험결과, 음의 전위 가용은 저위 미가용 시의 흡착에 비해 코발트이온의 흡착을 증가시켰다. 또한 흡착된 코발트 이온은 역전된 가용전위에 의해 용액으로 용출되었으며 이와 동시에 탄소체 전극이 재생되어, 전기흡착 공정의 가역성을 확인 할 수 있었다.

  • PDF