• 제목/요약/키워드: cyclic simple shear test

검색결과 39건 처리시간 0.022초

Experimental and numerical assessment of EBF structures with shear links

  • Caprili, Silvia;Mussini, Nicola;Salvatore, Walter
    • Steel and Composite Structures
    • /
    • 제28권2호
    • /
    • pp.123-138
    • /
    • 2018
  • Eccentrically braced frames (EBF) represent an optimal structural solution for seismic prone areas, being able to provide high dissipative capacity and good elastic stiffness, to withstand strong seismic events without significant loss of bearing capacity and to avoid damage to non-structural elements in case of low and moderate earthquakes. The accurate knowledge of the cyclic behaviour of the dissipative links, characterizing the whole performance of EBFs, is required to optimize the structural properties and to refine the design techniques adopted for multi-storey buildings' analysis. Reliable numerical models for the links, at the same time requiring a limited computational effort, are then needed. The present work shows the results of a wide experimental test campaign executed on real-scale one storey/one bay frames with horizontal and vertical links, together with the elaboration of a simple semi-analytical model for the quick representation of the cyclic behaviour of shear links.

흙의 종류에 따른 강도와 강성저하 특성 (Degradation Characteristics of Strength and Stiffness due to Soils)

  • 송병웅;김홍택;안원일재;촌상철;박인준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.253-260
    • /
    • 2004
  • Many scholars and researchers has been studied for many kinds of soil characteristics, but a lot of part are still unsolved. Cyclic load-induced decreasing characteristics of strength and stiffness of soils are also well not known among them. To know that, the characteristics of five kinds of soils; clay, plastic and non-plastic silt, sand, and a weathered soil are compared with dividing two types as plastic or non-plastic soils through direct simple shear(DSS) test. From the results of DSS test, it is known that decreasing characteristics of strength and stiffness are different according to soil types. The strength of plastic and non-plastic soils increases with increment of plasticity index and decrement of volume decrease potential, respectively. And the decreasing stiffness of plastic and non-plastic soils increases with decrement of plasticity index and increment of volume decrease potential, respectively.

  • PDF

반복단순전단시험에 기반한 조립토의 설계 액상화 저항 곡선 개발 (Cyclic Simple Shear Test Based Design Liquefaction Resistance Curve of Granular Soil)

  • 만도카일 사이둘라;박두희;김한섭;박기천
    • 한국지반공학회논문집
    • /
    • 제32권6호
    • /
    • pp.49-59
    • /
    • 2016
  • 본 논문에서는 지진 시 작용하는 반복적 하중에 의하여 발생하는 잔류 과잉간극수압 예측에 필요한 반복저항응력비(CRR)와 재하횟수 N 간의 관계를 나타내는 액상화 저항 곡선을 반복단순전단시험과 문헌조사를 통하여 도출하였다. CRR과 N 자료는 두 가지 모델을 이용하여 최적 곡선을 계산하였으며 계측된 자료와 비교한 결과, 이중 한 가지 모델은 CRR이 다소 작게 산정되어 정확도가 떨어지는 것으로 나타났다. 다양한 액상화 저항 곡선을 살펴본 결과, 반복저항응력비(CRR)는 재하횟수 N = 15에서의 CRR($CRR_{N=15}$)로 정규화할 경우, 분산이 크게 감소하는 것을 확인하였다. 이와 같은 정규화가 특별히 유용한 이유는 $CRR_{N=15}$은 실내시험이 아니라 현장시험으로부터 쉽게 산정 가능하기 때문이다. 정규화를 통하여 평균과 상한 및 하한 곡선을 도출하였으며, 각각에 상응하는 설계식과 변수 또한 제시하였다. 제안된 곡선은 추후 부지 고유의 지반응답해석과 항만 구조물의 안정성 평가 등에 활용될 수 있을 것으로 판단된다.

액상화 저항곡선과 실내실험에 기반한 구성모델 입력변수의 산정 (Evaluation of Input Parameters in Constitutive Models Based on Liquefaction Resistance Curve and Laboratory Tests)

  • ;;유병수;김성렬
    • 한국지반공학회논문집
    • /
    • 제36권6호
    • /
    • pp.35-46
    • /
    • 2020
  • 액상화 구성모델의 입력변수는 실내외 실험 등을 통해 지반 및 하중 조건에 적합한 값을 결정하는 것이 중요하지만, 설계 실무에서는 시험수행의 어려움 등으로 입력변수의 결정 및 해석결과의 검증이 어려웠다. 본 연구에서는 반복 직접전단시험에 대한 수치모델링을 수행하여 액상화 구성모델 중 Finn 모델과 PM4Sand 모델의 적용성을 분석하였다. 그 결과, Finn 모델은 과잉간극수압의 최대값 도달시점은 모사할 수 있었지만 항복 이후의 과잉간극수압 응답 및 응력-변형률 거동을 모사하는데 한계가 있었다. 이에 반해, PM4Sand 모델은 액상화 도달시점 및 및 액상화 이후의 응력-변형률 거동을 잘 모사할 수 있었다. 최종적으로, 설계조건에 맞는 액상화 저항전단응력비 CRR을 모사할 수 있는 액상화 모델의 입력변수 산정절차를 제안하고 PM4Sand 모델의 입력변수를 산정하는 간편식을 제안하였다.

Optimal distribution of steel plate slit dampers for seismic retrofit of structures

  • Kim, Jinkoo;Kim, Minjung;Eldin, Mohamed Nour
    • Steel and Composite Structures
    • /
    • 제25권4호
    • /
    • pp.473-484
    • /
    • 2017
  • In this study a seismic retrofit scheme for a building structure was presented using steel plate slit dampers. The energy dissipation capacity of the slit damper used in the retrofit was verified by cyclic loading test. Genetic algorithm was applied to find out the optimum locations of the slit dampers satisfying the target displacement. The seismic retrofit of the model structure using the slit dampers was compared with the retrofit with enlarging shear walls. A simple damper distribution method was proposed using the capacity spectrum method along with the damper distribution pattern proportional to the inter-story drifts. The validity of the simple story-wise damper distribution procedure was verified by comparing the results of genetic algorithm. It was observed that the capacity-spectrum method combined with the simple damper distribution pattern leaded to satisfactory story-wise distribution of dampers compatible with the optimum solution obtained from genetic algorithm.

Estimation of the load-deformation responses of flanged reinforced concrete shear walls

  • Wang, Bin;Shi, Qing-Xuan;Cai, Wen-Zhe;Peng, YI-Gong
    • Structural Engineering and Mechanics
    • /
    • 제73권5호
    • /
    • pp.529-542
    • /
    • 2020
  • As limited well-documented experimental data are available for assessing the attributes of different deformation components of flanged walls, few appropriate models have been established for predicting the inelastic responses of flanged walls, especially those of asymmetrical flanged walls. This study presents the experimental results for three large-scale T-shaped reinforced concrete walls and examines the variations in the flexural, shear, and sliding components of deformation with the total deformation over the entire loading process. Based on the observed deformation behavior, a simple model based on moment-curvature analysis is established to estimate flexural deformations, in which the changes in plastic hinge length are considered and the deformations due to strain penetration are modeled individually. Based on the similar gross shapes of the curvature and shear strain distributions over the wall height, a proportional relationship is established between shear displacement and flexural rotation. By integrating the deformations due to flexure, shear, and strain penetration, a new load-deformation analytical model is proposed for flexure-dominant flanged walls. The proposed model provides engineers with a simple, accurate modeling tool appropriate for routine design work that can be applied to flexural walls with arbitrary sections and is capable of determining displacements at any position over the wall height. By further simplifying the analytical model, a simple procedure for estimating the ultimate displacement capacity of flanged walls is proposed, which will be valuable for performance-based seismic designs and seismic capacity evaluations.

Behavior of full-scale prestressed pile-deck connections for wharves under cyclic loading

  • Blandon, Carlos A.;Krier, Christopher J.;Restrepo, Jose I.
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.455-468
    • /
    • 2019
  • The behavior of pile-deck connections of pile-supported marginal wharfs subjected to earthquake loading is of key importance to ensure a good performance of this type of structures. Two precast-pretensioned pile-deck connections used in the construction of pile-supported marginal wharfs were tested under cyclic loading. The first is a connection with simple reinforcement details and light steel ratio developed for use where moderate pile-deck rotation demands are expected in the wharf. The second is specifically developed to sustain the large rotation, shear force and bending moment demands, as required for the shortest piles in a marginal wharf. Data obtained from the test program is used in the paper to calibrate an equivalent plastic hinge length that can be incorporated into nonlinear analysis models of these structures when prestressed pile-deck connections with duct embedded dowels are used.

반복하중 증가에 따라 감소하는 전단강도의 간이 평가법 (A Simple Evaluation Method for Shear Strength Decreasing with Increasing Number of Cyclic Loading)

  • 송병웅
    • 한국지반환경공학회 논문집
    • /
    • 제8권4호
    • /
    • pp.57-65
    • /
    • 2007
  • 토목구조물의 안정성에 영향을 미치는 인자 중 지진에 의한 피해를 들 수가 있다. 최근의 지진 피해 사례를 분석하여 보면 모래와 같은 조립토뿐만 아니라 점성토, 실트 등과 같은 세립토에서도 크고 작은 피해 사례가 보고되고 있다. 이에 본 연구에서는 지진에 의한 기초지반의 강도저하를 평가하는 방법을 조사하기 위하여, 반복단순전단시험기를 이용하여 비배수상태에서 조립토 및 세립토에 반복하중을 작용시켜 지반의 강도저하특성을 조사하고 조립토의 경우에는 여유간극비, 세립토의 경우에는 소성지수를 이용하여 간단한 평가방법을 제안하였다. 분석결과에 따르면 액상화강도를 비교 분석하여 보면 조립토에서는 여유간극비의 증가에 따라 감소하고, 세립토의 경우에는 소성지수가 증가함에 따라 커지는 것을 알았다. 특히, 화강풍화토는 Collapse현상이 발생하여 다른 흙보다 현저한 강도 감소 경향이 나타났다. 간이강도저하 평가방법을 통해서 조립토와 세립토 거의 대부분이 양대수곡선상에서 -0.15 ~ -0.2의 범위내의 비슷한 기울기 내에서 분포하였지만, 화강풍화토와 같은 흙은 강도저하 경향이 -0.3으로 다른 흙보다 크게 나타남을 알 수 있었다. 본 강도저하 평가방법은 추가 연구가 필요하지만, 실무에서 간단하게 적용 가능할 것으로 보인다.

  • PDF

진동으로 인한 모래 공시체내의 밀도변화에 관한 연구 (Density Variation within Specimen as Affected by Vibration)

  • 장병욱
    • 한국지반공학회지:지반
    • /
    • 제3권3호
    • /
    • pp.7-20
    • /
    • 1987
  • 교번 삼축 압축시험, 교번 전단응력 시험, 액상화 시험 및 진동 테이블 시험 등을 하기 위하여 제작되는 공시체로서 잘 다져진 모래를 사용하게 되며 진동에 의해 다져진 모래의 공시체가 균일한 밀도를 갖는다는 가정하에 상기한 실험을 하여 왔다. 지금까지 이러한 가정에 대한 연구가 충분히 되어 있지 않았으며 신뢰도 높은 실험을 하기 위하여는 공시체내에 모래의 밀도가 균일한 공시체를 제작하는 것이 중요하다. 이 연구에서는 진동에 의해서 모래 공시체를 제작할 경우 공시체내에 밀도의 변화가 발생하는지 여부와 각 진동인자가 밀도변화에 미치는 영향을 조사하였다. 이 연구 결과 진동 전에 균일한 밀도 를 갖는 공시체가 진동 후엔 공시체의 높이에 따라 상당한 밀도의 변화가 발생하였음을 보였으며 이러한 현상은 과재 하중, 입도 및 진동가속도의 크기에 따라 상당한 영향을 받는 것으로 밝혀졌다.

  • PDF

인방형 강재댐퍼의 구조성능에 대한 실험적 연구 (Experimental Evaluation of the Seismic Performance for Lintel Beam Type Steel Damper)

  • 노경민;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.77-84
    • /
    • 2017
  • As an alternative to coupling beam in shear wall system, application of the damper which can dissipate energy is increasing. In this study, lintel beam type steel damper which is simple to construct and change depending on design load was proposed. Cyclic loading test was conducted to compare reinforced concrete coupling beam and lintel beam type steel damper. The test results showed that lintel beam type steel damper has higher initial stiffness and energy dissipation capacity than reinforced concrete coupling beam.