• Title/Summary/Keyword: cycle and cut-set

Search Result 9, Processing Time 0.026 seconds

A Study on the development of transfer system of cutting punched pipes. (타공파이프 절단을 위한 이송시스템 개발에 관한 연구)

  • Park, J.S.;Yoon, D.H.;Jung, C.S.;Kim, Y.S.;Yang, S.Y.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.66-69
    • /
    • 2010
  • A punched pipe in a muffler for an automobile has many important variables, like location of holes in the pipe and length of the pipe related to noise reduction of a diffuser. This pipe is cut depending on length of product and this process, generally workers cut pipes by hands. In this process, there are many errors and it relies on the skill of workers, so it can happen that cycle time for complete product gets long and productivity gets low. Therefore, we need a vision system to distinguish holes in the punched pipe and a transfer system to set the cutting position automatically by moving the pipe depending on forward and backward part of the holes. This paper explains the development of an automatic transfer device which will cause the beating pipe to be cut correctly, exactly the same length as the product.

  • PDF

The Evaluation of Explosion For Toluene Storage Tank by Computer-Aided Fault Tree Analysis (Fault Tree Analysis(FTA)에 의한 Toluene저장 Tank의 폭발해석)

  • Chung, Jae-Hee;Yi, Young-Seop
    • Journal of the Korean Society of Safety
    • /
    • v.3 no.2
    • /
    • pp.5-16
    • /
    • 1988
  • This study is conducted to evaluate the explosion of tolune storage tank in the petrochemical plant by Fault Tree Analysis. The conclusions are as follows; 1) Fault Tree diagram and the required computer program for evaluation of explosion accident is developed. 2) The probability of the top event, explosion accident, is $1.5\;{\times}\;10^{-8}$ per year, so there is almost no possibility of explosion during the life cycle of tank. However, the probability of Gate 6 and Gate 7 is 8.8 per month, therefore, attention should be paid to them for accident prevention. 3) The number of minimal cut sets is 67 sets which are not calculated the probability of each set, because of the lack of computer capacity. All the minimal cut sets should be examined case by case. However, it is necessary to be paid attention to COM1, 126, 131, and COM4 in minimal cut sets, because the number of appearance is so high. 4) The number path sets is 70 sets which are not calculated the probability of each set, because of the lack of computer capacity. It is very useful to prepare safety checklist by using this minimal path sets. Also, the events which appear many times, 123, COM5, 139, 127 and 128, are very high in reliability.

  • PDF

A case study on the selection process of cutoff wall for ground-water using VE/LCC analysis (VE/LCC 기법을 활용한 차수공법 선정사례 연구)

  • Cho Yong-Wan;Chang Jun-Ho;Kim Jin-Man;Ha Jae-In
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.279-291
    • /
    • 2006
  • This study shows decision-making process for selection of cutoff wall on a wastewater treatment project. There are 10 different cut-off wall methods So, we examine the site to gather information for find appropriate methods. After using that information, 10 cutoff wall methods are reviewed for analysis. Through brainstorming, four alternatives are selected for design VE item. Following the standard VE process, we established performance criteria and evaluated function score(F) using questionnaire. The questionnaires, brainstorming and AHP method for weighting on performance criteria and evaluate function score increased the reliability of this selection process. Water Jet method, one of four methods, has the best function score(F=92.71) and the lease construction cost(as cost index 1,000). The value score also highest as 92.7, so we select the method. The result is value innovation type In addition, the authors try to calculate the environmental burden in selection process using LCA. We cannot conduct the full LCA as defined ISO, so perform Simple LCA In LCA result, the cut-off grouting has the least environmental burden as index 9.09E+01 and Water Jet method has following as the second. To selection best method to specific area and purpose, design VE/LCG process used as useful tool and it is needed to develop integrated method that evaluate VEILCC and LCA as one-set process.

  • PDF

A Template Based Process Modeling Methodology for Control Simulation (제어 시뮬레이션을 위한 템플릿기반 공정 모델링 방법론)

  • Shin, Hye-Seon;Ko, Min-Suk;Hong, Sang-Hyun;Park, Sang-Chul;Wang, Gi-Nam
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.5
    • /
    • pp.351-360
    • /
    • 2011
  • Product systems are quickly and frequently changed because Product Life Cycle is continuously reduced and adopting new product is steadily fast. Thus, various studies are progressed using simulation which is one of digital manufacturing. The research that is concerning simulation of control verification for shorten the commissioning which has a lot of trial and error is in progress. Also, simulation of control verification has strength that it can catch the errors in advance. However, a control program in simulation needs virtual factory for representation of control information. For this reason, excessive time and energy is put into controlling the virtual factory. So, in this paper, we construct library which is using exist data, in order to overcome limitation of these problems. Furthermore, we suggest methodology which can model and verify the process more speedy using library. Especially, we give body to the BB/BR Line process which has many altering equipment and need high technology effectively using physical and logical modeling. We can set up a control simulation environment very rapidly, as well as cut process time down using our suggestion.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.510-515
    • /
    • 2007
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows ; 1) On the whole, typical rates of water-use was founded out 15 L / stu. d in pirmary school, 10 L / stu. d in middle school and 30L / stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking pick load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

  • PDF

A Study on Electrodewatering Filter Press Technology for Improvement of Dewarterability of Waterworks Sludge (정수슬러지 탈수효율 향상을 위한 전기필터프레스탈수에 관한 연구)

  • Lee, Jung-Eun;Lee, Jae-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1009-1015
    • /
    • 2006
  • The elcetrodewatering filter press(EDFP) which had anode and cathod plates to be set between filter plates was built for reducing the waterworks sludge and improving performance of dewatering equipment. Several tests to compare the dewaterability with conventional mechanical filter press dewatering(MDEP) and EDFP was conducted through this equipment. As test results, filtration amount discharged from EDFP measured 43.2 kg which increased against MDFP, and cake weight measured 4 kg which was two times against MDFP. The water content of dewatered cake from EDFP was 55wt% and dewatering velocity was 2.3 $kg/m^2{\cdot}cycle$. This water content decrease 20% and dewatering velocity increased 30% with compare to the MDFP. That is to say, EDFP constructed from electrodewatering mechanism increase filtrate discharging amount, which make dewatering velocity increase and produce the low water content dewatered cake against MDFP. Energy consumption of EDFP is analysed to 400 kwh/DS ton. The results to analysis the economical aspect considering the power consumption and the handling cost decline as sludge volume reduction due to producing the low water content cake showed that expenses to handle sludge of 1 ton by dry solid base cut down on 20,000 won. If considering several test aspects, it was analysed that EDFP was excellent in the side of performance as well as economical suitability.

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF