• Title/Summary/Keyword: cut-off diameter

Search Result 64, Processing Time 0.024 seconds

Theoretical Analysis and Experimental Evaluation of Small Cyclone Separator to Remove Fine Particulate Matter (미립 물질 제거를 위한 소형 사이클론 분리기의 이론적 연구 및 실험적 검증)

  • Ko, Han Gyul;Kim, Hong Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.77-82
    • /
    • 2013
  • A cyclone separator has been widely used in various industrial processes for removing fine particulate matter because it is easy to fabricate, cost effective, and adaptable to extremely harsh conditions. However, owing to the complex flow field in cyclones, a complete understanding of the detailed mechanisms of particulate removal has not yet been gained. In this study, a theoretical analysis was performed for calculating the collection efficiency and cut-off size in cyclones by taking into account the effects of geometrical and flow parameters. The collection efficiency and cut-off size values predicted by the theoretical model showed good agreement with experimental measurements for particles with a diameter of $0.5-30{\mu}m$. It was also revealed that the surface friction, along with the flow and geometrical parameters, has a significant effect on the cyclone performance.

Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles (다단 임팩터(MOUDI)의 조대 입자 채취 특성)

  • 배귀남;지준호;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

Numerical Investigation of Collection Efficiency of Virtual Impactor with Electro-Aerodynamic Lens (전기-공기역학적 렌즈를 이용한 가상임팩터 포집효율에 관한 수치적 연구)

  • Zahir, Muhammad Zeeshan;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.7
    • /
    • pp.63-70
    • /
    • 2019
  • An electro-aerodynamic lens for improving the performance of virtual impactor has been proposed in this study. ANSYS FLUENT Release 16.1 was used for numerical analysis of virtual impactor with and without the electro-aerodynamic lens, used to collimate the incoming aerosol particles into a particle beam before injecting the particles into the virtual impactor. Particles supplied to the electro-aerodynamic lens were assumed to be highly charged. By using an aerodynamic lens before the virtual impactor, without any electrostatic effect, it was found that the cut-off diameter of the virtual impactor was reduced from $4.2{\mu}m$ to $0.68{\mu}m$ and that the fine particle contamination problem became more serious. However, by employing the combined electrostatic and aerodynamic effects, that is, by applying electric voltage potential to the electro-aerodynamic lens, the cut-off diameter was found to be further reduced to $0.45{\mu}m$ and the fine particle contamination was eliminated.

Grain Size Determination of Copper Film by Electron Backscatter Diffraction (EBSD를 이용한 구리박막의 결정립 크기 결정)

  • Kim, Su-Hyeon;Kang, Joo-Hee;Han, Seung Zeon
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.9
    • /
    • pp.847-855
    • /
    • 2010
  • The grain size of a cross-section of $8{\mu}m$-thick copper film was determined by electron backscatter diffraction analysis. Grain size distribution histogram showed the presence of a large fraction of small-sized grains, and the mean grain size was significantly affected by handling of them. A cut-off grain size, below which all grains are ignored as noise and eliminated for the calculation of the mean value, should be three or four times as large as the step size. Due to the presence of small grains, the linear intercept method derived larger mean grain size, which depends less sensitively on the cut-off grain size than the equivalent circle diameter method.

Optimal Tricuspid Annular Size for Tricuspid Annuloplasty in Patients with Less-Than-Moderate Functional Tricuspid Regurgitation

  • Choi, Jae Woong;Kim, Kyung Hwan;Lim, Su Chan;Kim, Sue Hyun;Sohn, Suk Ho;Lee, Yeiwon;Hwang, Ho Young
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.325-331
    • /
    • 2020
  • Background: We evaluated the association between tricuspid annular dilatation and the development of moderate or severe tricuspid regurgitation (TR). Additionally, we determined the optimal tricuspid annular dilatation threshold to use as an indicator for tricuspid annuloplasty in patients with less-than-moderate functional TR (FTR). Methods: Between August 2007 and December 2014, 227 patients with less-than-moderate TR underwent mitral valve surgery without a tricuspid valve (TV) procedure. The TV annular diameter was measured via transthoracic echocardiography. The TV annular index (TVAI) was calculated as the TV annular diameter divided by the body surface area. The mean duration of echocardiographic follow-up was 42.0 months (interquartile range, 9.3-66.6 months). Results: Eight patients (3.5%) developed moderate or severe TR. The rate of freedom from development of moderate or severe TR at 5 years was 96.2%. TV annular diameter, left atrial diameter, preoperative atrial fibrillation, and TVAI were found to be associated with the development of moderate or severe TR in the univariate analysis. A cut-off TVAI value of 19.8 mm/㎡ was found to predict the development of moderate or severe TR, and a significant difference was observed in the development of TR of this severity based on this cut-off (p<0.001). Conclusion: The progression of TR was not infrequent in patients with untreated lessthan-moderate FTR. An aggressive treatment approach can be helpful to prevent the progression of FTR for patients with risk factors, especially TVAI greater than 19.8 mm/㎡.

Development of In-Line Trimming Shear (In-Line Trimming Shear 개발)

  • 이종일;강성구;서경수
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.119-125
    • /
    • 1999
  • At Wire Rod Mill Plant, wire is made of the billet produced at continuous casting machine, or rolled bloom produced at billeting mill, and the product can be classified of wire of 5.5${\Phi}$ and bar in coil of 14∼42${\Phi}$ in diameter(bar in coil will be referred to as coil as below). At present, wire is produced at POSCO No.1, 2, 3 WRM, coil at garret line of No. 2 WRM. Head and tail of coil are properly cut and treated to scrap to fulfill the customer's satisfaction. This above cutting is done off line, and small size coil can be cut manually with clipper, large size coil with hydraulic cutter. Nowadays, it is being investigated to cut automatically in line with trimming shear after passing mill stand. At the moment, Because the coil produced at the garret line of No.2 WRM is hot 400∼600$^{\circ}C$ and trimming is done manually with cutter, there are always interference from manual operation or safety problem of bad working condition. Not only because of the diversity of the coil size 14∼42${\Phi}$ in diameter, but because of the rolling speed 2.5∼22m/sec, it is required to be equipped with several trimming shear. But this can be accomplished with only one shear installed proper place at this paper.

  • PDF

Characteristics of Surface Roughness in the Wire-Cut Electric Discharge Cutting Conditions of Aluminium Alloy 2024 (알루미늄 합금 2024에서 와이어 컷 방전가공조건에 따른 표면 거칠기 특성)

  • Lee, Soon-Kwan;Ryu, Cheong-Won
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • Currently, the aircraft industry, aircraft parts as well as airframe have been developed in producing, the aircraft parts and fuselages have been produced the product by cutting rather than forging and casting because of the residual stress and stress concentration. In this study, the aircraft is being used in many parts of aluminium alloy 2024 in wire-cut E.D.M. The selected experimental parameters are peak current, no-load voltage, off time and feed rate. It is found that cutting mountain part on surface roughness of the curve 0.3mm than 0.25mm diameter wire electrode is stable in many uniform distribution.

Association of Serum HE4 with Primary Tumor Diameter and Depth of Myometrial Invasion in Endometrial Cancer Patients at Rajavithi Hospital

  • Prueksaritanond, Nisa;Cheanpracha, Patchara;Yanaranop, Marut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1489-1492
    • /
    • 2016
  • Background: Although there are no biomarkers that are routinely used in endometrial cancer (EC) management, many studies have found that serum human epididymis protein 4 (HE4) is superior to cancer antigen 125 (CA125) in the detection of EC. The correlation of HE4 with two prognostic factors for EC, primary tumor diameter (PTD) and depth of myometrial invasion (DMI) may be useful in identifying EC patients at high risk of lymphatic dissemination. Objective: To evaluate the correlation of serum HE4 with PTD and DMI in patients with EC. Materials and Methods: A cross-sectional study was conducted on 70 EC patients who were scheduled for elective surgery at Rajavithi Hospital between 1st September 2013 and 30th May 2014. Preoperative serum levels of HE4 and CA125 were investigated, and then gross measurement of PTD was taken and postoperative pathologic slides were reviewed for DMI including histologic types, grading and staging. Results: Preoperative serum HE4 levels were strongly correlated with PTD (r=0.65, p<0.001) and moderately correlated with DMI (r=0.46, p<0.001). Moreover, serum HE4 levels were significantly elevated in EC patients with PTD >2 cm (p<0.001) and DMI > 50% (p=0.004). The performance of serum HE4 in identifying EC patients at low risk and high risk of lymph node metastasis was significantly better than that of CA125 (AUC 0.88 vs. 0.65, p=0.003). At an optimal cut-off value of 70 pM/L, serum HE4 had a sensitivity of 83.3% and a specificity of 80.0%. Conclusions: In EC patients, preoperative serum HE4 is significantly correlated with PTD and DMI. Serum HE4 levels could be useful in identifying endometrial cancer patients at high risk of lymphatic spread who would benefit from systemic lymphadenectomy at the cut-off value of 70 pM/L.

A Study on the computer aided design for flow control valve of vane pump (베인 펌프용 유량 제어부의 전산설계에 관한 연구)

  • 이윤태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.555-560
    • /
    • 2000
  • The modeling and the numerical analysis are done so as to develop the Computer Aided Design program for the design of flow control valve attached to the vane pump. The factors affecting the flow rate characteristics, are analyzed by the experiments and the numerical methods. It is shown that the main factor affecting to the first control flow is the diameter of small rod of the spool, the main factor affecting to the second control flow is the diameter of big rod of the spool, the main factors affecting to the cut off are the main spring constant, the initial displacement of main spring and small diameter of the spool, and the dropping slope characteristics of flow rate are decided by the chamfer of spool and the dynamic characteristics of the spool.

  • PDF

Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using Bigh Performance Polymer Membranes ( I ) (기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성 (I))

  • Lee Jae-Dal;Hong Young-Ki;Ro Duck-Kil;Bae Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.17 no.3 s.82
    • /
    • pp.34-42
    • /
    • 2005
  • In this work, a practical separation performance was investigated on aqueous alcohol solutions, especially for iso-propyl alcohol (IPA), which is usually used during the semi- conductor rinsing process. The removal of various substances from waste aqueous IPA solutions was carried out by microfiltration with $0.1\~1{\mu}$m pore size of mean diameter as a pre-filter. Permeability and molecular weight cut-off of the functional polysulfone(PSf) ultrafiltration membrane to purify waste aqueous IPA solutions were measured through the ultrafiltration test. The solute rejection of PSf membrane had $92\%$ in 1,000ppm aqueous PEG solution with PEG molecular weight 10,000, the molecular weight cut-off had 10,000. The IPA concentration on the $CMPA-K^+$ membrane performance using pervaporation module system could be increased from $95.04 wt\%$ to more than $98.50wt\%$ in about 9hr at operation temperature of $70^{\circ}C$ using the pervaporation module system.