• Title/Summary/Keyword: curtain-wall

Search Result 239, Processing Time 0.02 seconds

The Characteristics on CIGS Thin Film PV Module for Curtain Wall Spandrel Applications (커튼월 스팬드럴 적용을 위한 CIGS 박막 모듈의 특성 분석 연구)

  • Kang, Jun-Gu;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.107-113
    • /
    • 2013
  • In this study, three different types of experimental models of BIPV curtain wall units with GIGS modules were built, and their thermal and electrical performances were analyzed. The experimental results showed that the temperature of the rear side of the GIGS module with the application of an insulation in the curtain wall spandrels was higher than a GIGS module standalone by $22^{\circ}C$, which results in a reduction in the power generation of the former by 8 %. On the other hand, when ventilation was applied to the model to improve the power generation performance, the module temperature was observed to be $142^{\circ}C$ lower compared to the enclosed type, and the power generation performance improved by 5 %. It confirmed that the temperature increase in the rear side of the GIGS module with insulation layer reduced the electrical performance of the module. Based on this, it is claimed that providing sufficient ventilation at the GIGS applied spandrels contribute to improve the power generation of the GIGS module.

Relationship of the U-Factor and Chemical Structure with Applied Metal and Polymer Material Assembly in Curtain Wall Frame

  • Park, Tongso
    • Korean Journal of Materials Research
    • /
    • v.31 no.8
    • /
    • pp.450-457
    • /
    • 2021
  • From measured thermal conductivity and modeling by simulation, this study suggests that U-factors are highly related to materials used between steel and polymer. The objective and prospective point of this study are to relate the relationship between the U-factor and the thermal conductivity of the materials used. For the characterization, EDX, SEM, a thermal conductive meter, and computer simulation utility are used to analyze the elemental, surface structural properties, and U-factor with a simulation of the used material between steel and polymer. This study set out to divide the curtain wall system that makes up the envelope into an aluminum frame section and entrance frame section and interpret their thermal performance with U-factors. Based on the U-factor thermal analysis results, the target curtain wall system is divided into fix and vent types. The glass is 24 mm double glazing (6 mm common glass +12 mm Argon +6 mm Low E). The same U-factor of 1.45 W/m2·K is applied. The interpretation results show that the U-factor and total U-value of the aluminum frame section are 1.449 and 2.343 W/m2·K, respectively. Meanwhile, those of the entrance frame section are 1.449 and 2.

Construction of Aluminum Curtain Wall with 3D Elevation for TRUTEC Building (트루텍 빌딩의 3차원 입체 커튼월 시공)

  • Park, Choel;Hong, Doo-Pyo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.119-122
    • /
    • 2007
  • TRUTEC building, which is located at DMC B block is zone, is just one the office building in Soeul. TRUTEC building is designed by Barkow Leibinger Architeken in Germany, has 5 stories under and 12 stories above and has been finished with the unique three dimensional curtain wall unit. Big trial to make unique elevation succeeded as getting rid of the typical plain curtain wall unit. In addition, aluminum bars are treated by the latest CNC machine in order to achieve 3D section. Construction of curtain wall is highly focused from the moment of contract to keep the schedule because the contract period is 18 months. Regular design meeting and technical meeting between stakeholders including construction manager, designer, engineer, consultant and so on have been held during the construction to minimize the risks from the unique elevation and trial. Step by step mock-up test (design mock-up and visual mock-up on site) has been performed before functional mock-up test.

  • PDF

A Study on BIM Implementation Process Model through Importing Vertex Coordinate Data for Customized Curtain Wall Panel - Focusing on importing Vertex Coordinate data to Revit from Rhino - (맞춤형 커튼월 패널의 꼭짓점 좌표데이터 전이를 통한 BIM 형태 구축 프로세스 모델 연구 - 라이노에서 레빗으로의 좌표데이터 전이를 중심으로 -)

  • Ko, Sung Hak
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.11
    • /
    • pp.69-78
    • /
    • 2019
  • The purpose of this study is to propose a modeling methodology through the exchange of coordinate data of a three-dimensional custom curtain wall panel between Rhino and Revit, and to examine the validity of the model implemented in the drawing. Although the modeling means and method are different, a fundamental principle is that all three-dimensional modeling begins by defining the position of the points, the most primitive element of geometry, in the XYZ coordinate space. For the BIM modeling methodology proposal based on this geometry basic concept, the functions and characteristics associated with the points of Rhino and Revit programs are identified, and then BIM implementation process model is organized and systemized through the setting of the interoperability process algorithm. The BIM implementation process model proposed in this study is (1) Modeling and panelizing surface into individual panels using Rhino and Grasshopper; (2) Extraction of vertex coordinate data from individual panels and create CSV file; (3) Curtain wall modeling through Adaptive Component Family in Revit and (4) Automatic creation of Revit curtain wall panels through API. The proposed process model is expected to help reduce design errors and improve component and construction quality by automatically converting general elements into architectural meaningful information, automating a set of processes that build them into BIM data, and enabling consistent and integrated design management.

Performance Evaluation of Curtain-Wall Applying Light-weight Inorganic Foam Panel (경량 무기 발포패널을 적용한 커튼월의 성능평가)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.211-212
    • /
    • 2012
  • To prevent energy waste in buildings used heat insulator. Heat insulator materials can be classified inorganic and organic. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. However, there is little study to explain fire resistance performance of the curtain walls. This study focused on evaluation of the physical properties of light-weight inorganic foam panel for using industrial by-products materials and performance evaluation by mock up test.

  • PDF

A Study on the Change of Surface Temperature of Back Panel by Variation of the Air-Space Distances on the Inside of Curtain Wall (커튼월 내부 공기층의 BACK PANEL 표면온도에 관한 연구)

  • Lee, Duck-Hyung;Son, Won-Tug;Choi, Hyun-Sang;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.3
    • /
    • pp.87-93
    • /
    • 2011
  • When applying back panel(this material is aluminum complex panel coated with fire resistance substances) for curtain wall, solar radiation and heat storage of indoor air occurs to result in thermal warpage for back panel. The purpose of this analysis is to find out the cause of thermal warpage and come up with a solution to prevent changes of back panel and reduce elements that bring negative visual elements. Also to solve this problem analyse that case to reduce heat transfer by inserting additional material and cases to increase air space distance.

Evaluation of one component structural sealant for curtain wall. (커튼월용 1액형 구조용 실란트 물성 평가 연구)

  • Han, Chang-Hwa;Jung, Jin-Young;Bae, Ki-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.228-229
    • /
    • 2014
  • Recently, to ensure the high openness and prospect right of the building, curtain wall system is mainly applied to the high-rise buildings at domestic and overseas. As a result, the use of Structural Sealant is increasing. Structural Glazing Sealant is applied with the glass and AL-FRAME (Mullion) that the strong structural strength is required to hold. However, the structural sealant at the construction site in a variety of external influences, such as wind load, thermal load, uv, chemical pollutants etc, in case of storing condition, if structural sealant stored in high temperature for a long period time, it will not perform well compared with initial performance. In this study, the influence of the performance of one-component structural sealant evaluated for proper storage conditions at the construction site and how to use the non-intended.

  • PDF

The Structural Analysis of the Curtain Wall System for the Attached Cleaning Robot (청소로봇이 부착된 커튼월 부재의 구조해석)

  • Han, Yu-Gil;Lee, Yong-Won;Yeun, Gyu-Won;Kim, Jong;Seo, Sang-Kyo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.197-198
    • /
    • 2011
  • Most of buildings' exterior walls are curtain wall systems and in the respect, the cleaning robot system is the main research item for cleaning and maintenance of them. We have structurely analysed the cases to review on the structural stability of the mullion members where the cleaning robot is attached. The result is showing that the largest stress is formed by the basic wind speed, which is specified in Korean Building Code-Structural.

  • PDF

Application of the Robot for Curtain Wall Installation in a High Building (고층 빌딩 커튼월 시공 작업에서의 로봇 활용에 관한 연구)

  • Lee, Soung-Yel;Ko, Bong-Soo;Lee, Kye-Young;Lee, Sang-Heon;Ohk, Young-Mu;Han, Chang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1488-1493
    • /
    • 2003
  • Recently, higher and bigger building is trend of the construction. Accordingly the building material is getting bigger and construction equipments are developed. But operation is still depends on human resource. Therefore there have several problems that are safety, laborious operation, and shortage of worker. In the various construction sites, the automation in construction is introduced to solve these problems. This paper proposed the automation system in construction that installs curtain wall in a high building. The system is expected effects that are reduction of a construction period, retrenchment of the cost and assurance of safety.

  • PDF

An Analytical Study on Primary Anchor Unit for ALC Panel Curtain-wall (ALC 패널 커튼월용 부품 Primary Anchor의 해석적 연구)

  • Yoon, Myung-Ho;Ryu, Chang-Hyun
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.1
    • /
    • pp.8-14
    • /
    • 2011
  • This study aims at grasping the structural performances of primary anchor assemblage through a nonlinear finite element analysis. Primary anchor unit may be used as one of the connection devices between ALC panel curtain-wall and RC slab or main frame of a building. From the analytical results structural characteristics such as yield strength, initial stiffness and maximum strength are obtained and fully discussed.