• Title/Summary/Keyword: current unbalance

Search Result 263, Processing Time 0.027 seconds

Study on the Oversea Technology Development of Electric Power Storage System and It's Domestic Application (전력저장시스템 기술개발 국외동향 분석 및 국내 활용방안 연구)

  • Choi, Kyung-Shik;Yang, Seung-Kwon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.57-60
    • /
    • 2008
  • As the technology of a large scale battery have advanced, it's application to the electric power network have been active in foreign country. By providing the electric power energy stored in the electric power storage system when needed, there are many advantages that it is able to reduce the gap between the electric power demand and supply for day and night to increase capacity factor, to upgrade the electric power quality degraded from the unbalance between power demand and supply and to compensate the fluctuation of wind power plant and photovoltaic power generation. In this study, the current application of electric power storage system using battery is introduced in detail, and I have thought out it's application fields based on the foreign examples. These are demand side response, upgrade of the power quality, stabilization of fluctuation of renewable energy and distributed generation for filling elapse.

  • PDF

Operating Method of 3 Phase Voltage type PWM Converter for Unbalanced Voltage with Leakage Transformer (누설변압기가 부착된 전원 불평형 3상 전압형 PWM 컨버터 운전법)

  • Chun, Ji-Yong;Kim, Young-Chun;Cho, Yu-Hwan;Lee, Keun-Hong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.125-127
    • /
    • 2005
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining way of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. Because it is possible that the unbalanced System control is used to leakage transformer not equaled reactance by each phase in rectifier system, the proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

A Non-Isolated 3-Level High Step-Up Boost Converter With Output Voltage Balancing (출력 전압 밸런싱 기능을 가진 비절연형 3-레벨 고승압 부스트 컨버터)

  • Yun, Song-Hyun;Kang, Hyemin;Cha, Honnyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.464-470
    • /
    • 2015
  • In this paper, a non-isolated three-level high step-up boost converter with output voltage balancing is proposed. By adding one extra inductor to the conventional three-level boost converter, the proposed converter is derived. Compared with the traditional boost converter and the three-level boost converter, the proposed converter can obtain very high voltage conversion ratio, and the voltage and current stress of switching devices and diodes are reduced. A 2.7 kW prototype converter is built and tested to verify performances of the proposed converter.

Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage (불평형 전압 운전시 유도전동기의 동작 특성 해석)

  • 김종겸;박영진;정종호;이은웅
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.6
    • /
    • pp.372-379
    • /
    • 2004
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Rotating machines operating on an unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on steady states of a three-phase induction motor under unbalanced voltages. The three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting the magnitude and phase angle of each phase. The voltage unbalanced factor(VUF) of the three-phase source voltages can then be varied to examine the different values of VUF on machine's operation characteristics.

A study on the DC Capacitor Voltage control of 5 Level Inverter for Static Var Compensator (자려식 SVC용 5레벨 인버터의 직류측 콘덴서 전압제어에 관한 연구)

  • 김종윤;오진석;공관식
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.1
    • /
    • pp.223-228
    • /
    • 1999
  • A five-level VSI(Voltage Source Inverter) is introduced as a SVC(Static Vu Compensator) like a large scale power source. The problems in using SVC are that the power device can easily be destroyed by voltage unbalance and accurate reactive power control is difficult because of voltage variation. A asymmetrical PAM(Pulse Amplitude Modulation) switching pattern is proposed to solve this problem and analyze both fundamental component and harmonic current in the system. Through experimental results of 3.5 kVA experimental test system, It is confirmed that DC capacitor voltage can be controlled by asymmetrical PAM switching pattern control.

  • PDF

New Fault Location Algorithms by Direct Analysis of Three-Phase Circuit Using Matrix Inverse Lemma for Unbalanced Distribution Power Systems

  • Park, Myeon-Song;Lee, Seung-Jae
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.79-84
    • /
    • 2003
  • Unbalanced systems, such as distribution systems, have difficulties in fault locations due to single-phase laterals and loads. This paper proposes new fault locations developed by the direct three-phase circuit analysis algorithms using matrix inverse lemma for the line-to-ground fault case and the line-to-line fault case in unbalanced systems. The fault location for balanced systems has been studied using the current distribution factor, by a conventional symmetrical transformation, but that for unbalanced systems has not been investigated due to their high complexity. The proposed algorithms overcome the limit of the conventional algorithm using the conventional symmetrical transformation, which requires the balanced system and are applicable to any power system but are particularly useful for unbalanced distribution systems. Their effectiveness has been proven through many EMTP simulations.

Extended Wing Technique Approach for the Detection of Winding Interturn Faults in Three-phase Transformers

  • Balla, Makarand Sudhakar;Suryawanshi, Hiralal Murlidhar;Choudhari, Bhupesh Nemichand
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.288-297
    • /
    • 2015
  • This paper presents a novel approach to diagnose interturn insulation faults in three-phase transformers that operate at different loading conditions. This approach is based on the loci of instantaneous symmetrical components and requires the measurement of three input primary winding currents and voltages to diagnose faults in the transformer. The effect of unbalance supply conditions, load variations, constructional imbalance, and measurement errors when this methodology is used is also investigated. Wing size or length determines the loading on the transformer. Wing travel and area determine the degree of severity of fault. Experimental results are presented for a 400/200 V, 7.5 kVA transformer to validate this method.

LLC Resonant Converter with Two Transformers and Resonant Tanks (두개의 변압기와 공진 탱크로 구성된 LLC 공진 컨버터)

  • Kim, Joo-Hoon;Kang, Sung-In;Kim, Eun-Soo;Jun, Yong-Suk;Lee, Jae-Sam;Huh, Dong-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.406-414
    • /
    • 2009
  • To cope with the high power density and low cost in switching power supply, LLC resonant converters with the two resonant tank circuits composed of resonance capacitors and two transformers are proposed in this paper. Each transformers used for the proposed resonant circuits are parallel connected in the primary and series connected in the secondary to reduce the current unbalance. The proposed LLC resonant converters are described and verified on 300W experimental prototype.

Power Quality Compensate System Using Photovoltaic System (태양광발전 시스템을 이용한 전력품질 보상시스템)

  • Han S.W.;Choe G.H.;Jang D.H.;Shin W.S.;Kim H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.76-80
    • /
    • 2001
  • Voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problems in many systems. Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. In this paper, proposed power quality compensate system using photovoltaic system is not only for harmonic compensation but also for harmonic isolation between supply and load, and for voltage regulation and unbalance compensation. Through computer simulations, we have verified the effectiveness of the proposed system.

  • PDF

Analysing and comparing efficiency of harmonic reduction equipment for Induction Motor (유도전동기의 고조파 저감장치 성능 비교 분석)

  • Park, Yang-Birm;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.47-52
    • /
    • 2005
  • Recently, power conversion equipment increased rapidly makes a lot of harmonics. Thus, it is growing that wrong operation and break down of sensitive devices. There are two kinds of causes of harmonics. One of them is lots of power conversion equipment as modem controller, inverter, converter and SWS(Switching Mode Power Supply). Another is nonlinear operating machines as transformer and motor. The more nonlinear loads like them grow, the more serious problems as harmonic current to source and low power factor because of increasing reactive power grow. It is installed for reactor and L-C Filter to decrease harmonic in general. This paper analysis and compares two of characteristics and harmonic from reactor and L-C Filter with operation of induction motor and power conversion equipment. In the result, L-C Filter more improves unbalance rate and THD than reactor.