• Title/Summary/Keyword: current standard

Search Result 3,834, Processing Time 0.03 seconds

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

Analysis on Forward/Backward Current Distribution and Off-current for Doping Concentration of Double Gate MOSFET (DGMOSFET의 도핑분포에 따른 상 · 하단 전류분포 및 차단전류 분석)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2403-2408
    • /
    • 2013
  • This paper has analyzed the change of forward and backward current for channel doping concentration to analyze off-current of double gate(DG) MOSFET. The Gaussian function as channel doping distribution has been used to compare with experimental ones, and the two dimensional analytical potential distribution model derived from Poisson's equation has been used to analyze the off-current. The off-current has been analyzed for the change of projected range and standard projected range of Gaussian function with device parameters such as channel length, channel thickness, gate oxide thickness and channel doping concentration. As a result, this research shows the off-current has greatly influenced on forward and backward current for device parameters, especially for the shape of Gaussian function for channel doping concentration.

A Study on Characteristics of Water Content Changes of Wastewater Sludge Using Direct Current Electricity (직류전기를 이용한 하수슬러지 함수율 변화특성에 관한 연구)

  • Ahn, Jeong-Mo;Song, Ji-Yun;Joo, Jae-Young;Bae, Yun-Sun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.609-615
    • /
    • 2010
  • This study examined the change of water content in sludge using direct current electric equipment for decreasing the amount of sludge. The experiment showed that the average density of solids in the sludge treated by direct current before the centrifugal dewatering process was increased by 47.8%, when compared to those not treated by direct current. From the result of measuring the granularity of the sludge by the direct current treatment, that the average particle size of the sludge that was not exposed to the electric current was 52.36 ${\mu}m$, and more than 90% of the sludge was <94.29 ${\mu}m$ in size. On the other hand, the average particle size of the sludge passed through the direct current was 28.67 ${\mu}m$, and more than 90% of the sludge was 52.46 ${\mu}m$. This means that the average particle size of the sludge treated by the direct current was 45.2% smaller, and the standard deviation of granularity was improved. Because of water that separated from sludge moves to the (+) pole, larger particles become smaller and fine particles combine together, resulting in the equalization of the particle size. On the sludge after the centrifugal dehydrator, the change of the water content by the direct current was measured. The results showed that the average density of the solids was increased by 44.2% compared.

Current Status and Problems of the ICT In-service Training for Teacher Based on the Operating Guide and Skill Standard of ICT (정보통신기술교육 운영지침과 활용능력기준에 기초한 교원정보화 연수 현황 및 문제점 분석)

  • Kim, Jong-Hye;Kim, Yong;Lee, Won-Gyu
    • Journal of KIISE:Software and Applications
    • /
    • v.34 no.9
    • /
    • pp.848-856
    • /
    • 2007
  • The curriculum for teacher ICT in-service training has several problems in terms of running and managing training content. The majority part of the program consist of teaming software application manual. Additionally, the program is not organized and some contents overlap. Furthermore teachers are not obliged to participate in training. Especially, it needs to be revised because it is many difference between revised ICT curriculum and 'ICT skill standard for teacher(ISST)'. This study investigates the current curriculum for teacher ICT in-service training, analyzes problems in running and managing training content, and suggests need for revising the curriculum for teacher ICT in-service training.

A Study on the Recognition of Green Standard for Energy and Environmental Design(G-SEED) from the Survey of Multi-complex Residents in Newtown (신도시 공동주택 거주자 대상의 녹색건축 인증제도 인식도 조사 및 분석)

  • Mok, Seon-Soo;Park, Ah-Reum;Cho, Dong-Woo
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.23-28
    • /
    • 2013
  • Green Standard for Energy and Environmental Design(G-SEED) has been used for environmental friendly building certification since 2002. The certification criteria initialed with multi-residential building and now it expands to 10 criteria for new and existing building types. The purpose of this study is to understand current recognition of G-SEED from the survey of multi-complex residences in newtown. From the general question, 75.2% of responders answered the period of living term between 1~3 years, 58.6% lived in $102.48{\sim}132.23m^2$ residential area and 65.2% owned their residences. The 43.2% of respondents recognized that their residences gained G-SEED certification by G-SEED emblem(31.6%). This is the significant meaning to understand public recognition of G-SEED and how to approach the strategy for raising the G-SEED recognition. The responders expected positive influence for economical value from G-SEED and also 75.3% of responders agreed with that G-SEED would be a decision make to buy and rent their residences. Second, residents responded that the consideration issue for green building is energy & prevention of environmental pollution(27.7%) which carries equal concern in G-SEED criteria category. The result of this survey verifies that the current level recognition of G-SEED of the responder's perspectives still is not well-known but it confirmed they have a positive expectation. Therefore, from this result, G-SEED needs to draw road map with detail plans for developing G-SEED with public participation.

Study on the Consistency of Pedestrian Road Width in Neighborhood Area (국내 근린지역 보행로 폭의 일관성 비교)

  • Jeong, woojin;Oh, Heung-un
    • International Journal of Highway Engineering
    • /
    • v.20 no.2
    • /
    • pp.87-96
    • /
    • 2018
  • PURPOSES : The purpose of this study is to compare the consistency of widths by analyzing the current situation of the sidewalk in Korea and Japan Neighborhoods Area. METHODS : Literature on the sidewalk width of the Neighborhood Area is reviewed to compare the consistency of width. Through on-site surveys, We identify the current status of sidewalk in Korea and Japan. This compares the sidewalk width consistency in the Neighborhood Area. RESULTS : The width of whole sidewalks in Japan is ranged 330~445cm, which is lAvger than The width of whole sidewalks in Korea, ranged 237~420cm. Frontage Zone width is ranged 60~65cm in Japan, similar to 60cm in Korea. However, in Korea, there is a lAvge difference between Frontage Zone width and walking width average, and the standard deviation of width is lAvger than Japan. The Pedestrian Zone width is ranged 172~325cm in Japan, which is lAvger than ranged 0~295cm in Korea. The width of the Furniture Zone is ranged 135 ~ 331cm in Japan and lAvger than ranged 90~225cm in Korea. In Korea, the difference between the Furniture Zone width and the walking average width is small, and the standard deviation of width is smaller than that of Japan. CONCLUSIONS : In conclusion, the standard deviation of the frontage zone and the pedestrian zone width, which are included in the valid sidewalk width, The Korea is lAvger than in Japan. valid sidewalk width of Korea sidewalk is inconsistent. valid sidewalk width for wheelchair users does not meet the width of more than 2 meters.

A Study on Local Standard Complement Between the LED Signal Head and Traffic Controller for Improving Signal Safety (신호의 안전성 향상을 위한 교통신호기와 LED신호등의 연계 특성 개선 방안 연구)

  • Le, Choul-Ki;Lee, Jeong-Jun;Oh, Bong-Sik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.2
    • /
    • pp.45-52
    • /
    • 2009
  • The off-state impedance of LED signal head is greater than that of a traditional bulb signal head, and the traffic controller has inherent off-state output leakage current. These two characteristics make the field trouble and reduce signal safety when the LED signal head is installed with traffic controller. In this Paper, a complement method of the LED signal head and traffic controller local standard (220vac line voltage) for improving signal safety is suggested. The point of designed complement method is to reduce the output leakage current of the traffic controller under 3mA, to increase the voltage feedback threshold to $70{\pm}5V$, and to make LED signal head maintain off-state in 0-95vac with 10Kohm maximum impedance.

  • PDF

Air Pollution History, Regulatory Changes, and Remedial Measures of the Current Regulatory Regimes in Korea (우리나라 대기오염 역사, 규제의 변천, 현행 규제제도의 개선방안)

  • Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.353-368
    • /
    • 2013
  • All Koreans had suffered heavily from municipal and industrial air pollution problems since 1960's to 1980's. However the levels of $SO_2$, CO, and Pb have been dramatically decreased since 1990's due to various air pollutants' reduction policies under the provisions of the 1978 Environmental Preservation Act and the 1990 Air Quality Preservation Act such as increasing the supply of low-sulfur fuel, the use of cleaner fuel, no use of solid fuel, and so on. Even though the national ambient air quality standard has been strengthened to protect public health and welfare, the levels of $NO_2$, $O_3$, and $PM_{10}$ frequently exceed the corresponding standards; for example, only 4 stations (1.7%) out of 239 nationwide monitoring stations satisfied the 24-hr based PM10 standard in 2011. Moreover, upto the present time, since there are serious underlying policies of economism and growth-first which can not be solely solved by the environmental laws, it is difficult to root out undesirable social evils such as public indifference, passive academic activities, complacent government bureaucracy, insufficient social responsibility of enterprise, and radical activities of environmental groups. The paper initially reviewed air pollution history of Korea with surveying various environmental factors affecting in/out-door air pollution in the past Korea. Further this study extensively investigated legal and political changes on air pollution control and management for the last 50 years, and then intensively discussed the present environment-related laws and policies unreasonably enforced in Korea. It is necessary to practically revise many outdated legal policies based on health-oriented thinking and on our current economic levels as well.

Analysis of Total Petroleum Hydrocarbon in Domestic Distribution Petroleum (국내 유통 중인 석유제품 내 석유계 총 탄화수소화합물(TPH) 분석)

  • Lim, Young-Kwan;Kim, Jeong-Min;Kim, Jong-Ryeol;Kwon, Min-Jeong;Lee, Kyoung-Heum;Ryu, Seong-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.27 no.5
    • /
    • pp.546-550
    • /
    • 2016
  • Over 60~70% of the domestic soil contamination have occurred by petroleum products. B T E X including benzene, toluene, ethylbenzene, xylene and total petroleum hydrocarbon (TPH) have to be inspected for the contaminated soil by petroleum products. An accurate contamination analysis is necessary to estimate the are of contaminated soil and also establish an appropriate purification scheme. In this study, we analyzed a sectional TPH pattern for current domestic distributed petroleum products. Also, the TPH content was analyzed by compensating the defect of current Korea standard analytic methods for soil where the analytic range is just for $C_8{\sim}C_{40}$. The light distillate petroleum products such as gasoline and solvent 1 showed the maximum of 85% difference in the TPH content between the standard analytic and improved methods.

Construction of Low Magnetic Standard System using a Multi-layer Solenoid with Single-current (단전류-다층 솔레노이드 방법을 사용한 저자장 표준시스템 제작)

  • 박포규;김영균
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.1
    • /
    • pp.38-44
    • /
    • 2001
  • The magnetic field standard below 1 mT with the resolution of 0.26 nT has been established. Earth magnetic field (EMF) is compensated automatically down to 0.1 nT/10 min. by a closed feedback system with Cs optical pumping magnetometer and 3-axis Helmholtz coils in nonmagnetic facilities. A multi-layer precision solenoid with the optimized single-current method generates the uniform magnetic field better than 1.0$\times$10$\^$-7/ within $\pm$ 1 cm region at its center. The coil constant of solenoid determined from Helium optical pumping magnetometer is 1.231 058 9 mT/A, and temperature coefficient is 0.38 nT/$\^{C}$. This standard system is used for calibration of low field magnetometers and testing relates to low field.

  • PDF