• Title/Summary/Keyword: current sink

Search Result 134, Processing Time 0.026 seconds

Development of LED Module Control-based PWM Current for Control of Heat-dissipation (방열특성 제어를 위한 PWM 전류제어 기반 LED 모듈 개발)

  • Lee, Seung-Hyun;Moon, Han Joo;Hue, Seong-bum;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.129-135
    • /
    • 2015
  • This paper shows significant methods that improve the lifespan of LED modules as well as efficiently using an aluminum heat-sink for LED module in high power. It proposes a method that raises stability and lifespan to protect LED modules and the power unit when the LED module has been used for a long hours at high temperatures. During the research, we applied a method of pulse-width modulation (PWM) in order to prevent the phenomenon that the entire power of a system is turned off and the lifespan is reduced when the LED nodule reacts to the high temperatures. To protect the LED module and SMPS based on high efficiency, a temperature sensor is attached underneath the circuit board and the sensor measures the temperature of circuit board when the LED module is powered on. The electrical power connected to SMPS is controlled by PWM when the temperature of the LED module reaches a particular temperature.

Actual Conditions of Lighting Environment of Kitchen and Washroom Spaces in Houses between China and Korea

  • An, Ok-Hee;Jia, Hao;Lee, In-Hyo;Kim, Hyun-Ji
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • To compare the lighting environment of kitchen and bathrooms in the apartments in China and Korea, this research conducted a study of the current status, targeting 68 households in China and 79 households in Korea. The results are as follows. First, the Korean kitchen space is a little bigger than China's, but the height of the sink and table show no difference. China does not use local lighting in the kitchen. And Korea 40.2[%], China 65.6[%] is sink's KS based was below. In the case of the dining table, KS criteria satisfy both Korean and Chinese standards. 20[%] appear to be very feeble; urgent improvements are required. Secondly, regarding the size of the bathroom, Korea and China show similar sizes; the average height of the vanities and toilet is higher in Korea than in China by 2[cm]. China does not use local lighting in the bathroom. The levels of illumination were measured; lighting is higher in China's bathrooms compared to Korea's.

A Study on the Efficiency Prediction of Low-Voltage and High-Current dc-dc Converters Using GaN FET-based Synchronous Rectifier (GaN FET 기반 동기정류기를 적용한 저전압-대전류 DC-DC Converter 효율예측)

  • Jeong, Jea-Woong;Kim, Hyun-Bin;Kim, Jong-Soo;Kim, Nam-Joon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.297-304
    • /
    • 2017
  • The purpose of this paper is to analyze losses because of switching devices and the secondary side circuit diodes of 500 W full bridge dc-dc converter by applying gallium nitride (GaN) field-effect transistor (FET), which is one of the wide band gap devices. For the detailed device analysis, we translate the specific resistance relation caused by the GaN FET material property into algebraic expression, and investigate the influence of the GaN FET structure and characteristic on efficiency and system specifications. In addition, we mathematically compare the diode rectifier circuit loss, which is a full bridge dc-dc converter secondary side circuit, with the synchronous rectifier circuit loss using silicon metal-oxide semiconductor (Si MOSFET) or GaN FET, which produce the full bridge dc-dc converter analytical value validity to derive the final efficiency and loss. We also design the heat sink based on the mathematically derived loss value, and suggest the heat sink size by purpose and the heat divergence degree through simulation.

Optimized Design of a Cold Plate Heat Sink using FEM and Optimization (유한요소법과 최적설계기법을 활용한 히트싱크 콜드 플레이트 최적 설계)

  • Hong, S.;Seo, H.;Kim, J.;Sim, J.;Hwang, J.
    • Transactions of Materials Processing
    • /
    • v.23 no.7
    • /
    • pp.419-424
    • /
    • 2014
  • In order to improve efficiency, an outdoor unit using a refrigerant cooling method is designed into many air conditioner systems. The heat exchanger is composed of a Cu tube and an plate. The optimal design for the cold plate is very important because the efficiency of the heat transfer depends on the contact area between the Cu tube and the cold plate. The current study focused on the design of the cold plate to obtain a uniform contact between the Cu tube and the cold plate. Both FE(finite element) analysis and optimization were used in the design. The contact area between the tube and plate was predicted and improved by 16% through the press forming simulations. The springback after press forming was also reduced when the optimized design parameters were used. To verify the validity of the optimal cold plate design, a verification test was conducted. As a result, the performance of the heat exchanger improved by 34% when compared to benchmarked products.

An Experimental Study on the Heat Transfer Characteristics of the Conversion Efficiency in the Concentrated Photovoltaic Cells (방열 특성에 따른 집광형 태양전지의 광전변환효율 변화에 관한 실험적 연구)

  • Kim, Kangho;Jung, Sang Hyun;Kim, Youngjo;Kim, Chang Zoo;Jun, Dong Hwan;Shin, Hyun-Beom;Lee, Jaejin;Kang, Ho Kwan
    • Current Photovoltaic Research
    • /
    • v.2 no.4
    • /
    • pp.168-172
    • /
    • 2014
  • Under concentrated illuminations, the solar cells show higher efficiencies mainly due to an increase of the open circuit voltage. In this study, InGaP/InGaAs/Ge triple-junction solar cells have been grown by a low pressure metalorganic chemical vapor deposition. Photovoltaic characteristics of the fabricated solar cells are investigated with a class A solar simulator under concentrated illuminations from 1 to 100 suns. Ideally, the open circuit voltage should increase with the current level when maintained at the same temperature. However, the fabricated solar cells show degraded open circuit voltages under high concentrations around 100 suns. This means that the heat sink design is not optimized to keep the cell temperature at $25^{\circ}C$. To demonstrate the thermal degradation, changes of the device performance are investigated with different bonding conditions and heat sink materials.

Prediction of temperature rise of Electric Switching Device Using CFD-CAD Integrated Analysis (CFD-CAD 통합해석을 이용한 전력기기 온도상승 예측)

  • Ahn, Heui-Sub;Lee, Jong-C.;Choi, Jong-Ung;Oh, Il-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.808-810
    • /
    • 2002
  • Higher current-rating and improved thermal performance are being sought for existing medium-voltage vacuum circuit breakers(VCB) in order to meet market needs which require to be compact and downsized. In this paper, thermal performance of medium voltage vacuum circuit breaker was investigated through experiments and numerical analysis. We changed several major parameters of current-rating and heat sink affecting on thermal behaviors in the breaker and observed the results. To predict the temperature distribution in complex three-dimensional (3-D) VCB components and gas, the commercial package was used to simulate conjugate heat transfer. Although some assumptions and simplifications were introduced to simulate the model, results from the computational model were in good agreement with actual temperature rise measurements obtained from experiments.

  • PDF

A Study on Optimization Development of Peltier Air-conditioning System (펠티어 냉난방시스템 최적화 기술에 관한 연구)

  • Park, Sanghoon;Jeong, Soojin;Park, Youngwoo;Park, Ukyung;Song, Beomjung
    • Journal of Institute of Convergence Technology
    • /
    • v.3 no.1
    • /
    • pp.19-23
    • /
    • 2013
  • This study is concerned with air-conditioning system in use of thermoelectric device. It is introduced that the well designed structures for better cooling & heating performance with high efficiency. And also it is performed that the system performance test of four types trial products for the use of hybrid commercial vehicle. System performance is affected by many component parts, especially heat sink design & power control method. It is applied that dual extrusive fin tube with buffer zone for the effective radiating of circulating liquid in tube. And also it is applied that power supply method with constant-current system. It is attained that system cooling capacity is 1.2kW, COP is 0.95.

  • PDF

Open frame type Power Module for Telecommunication of High Power Density (정전류 기능이 부가된 고전력 밀도의 통신기용 개방형 전원장치)

  • Yon, Je-Sun;Ahn, Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.143-146
    • /
    • 2004
  • This is a thesis that 100W class open frame type power module of a quarter-brick size appropriate for telecommunication is reported. The input voltage is established between 36 and 75 in range in order for power module to be utilized for the telecommunication, and output were set at 3.3V and 30A. A number of parts used for transformer, inductor, and hit sink are composed of PCB in order for DC-DC converter to be lowered below 8 mm. A constant current control circuit was annexed to the system as well as basic protection prototypes such as over-voltage, over-current, and over-temperature were well considered to enhance more credibility, and were tested. As a result, high circuit performance and credibility turned out to be significant.

  • PDF

Global Carbon Budget and Ocean Buffering against Rising Atmospheric CO2 Concentration

  • Kwon, O-Yul
    • Journal of Environmental Science International
    • /
    • v.11 no.8
    • /
    • pp.773-781
    • /
    • 2002
  • The natural carbon cycle has been perturbed since the mid-19th century by anthropogenic CO$_2$emissions from fossil fuel combustion and deforestation due to population growth and industrialization. The current study simulated the global carbon cycle for the past 42 years using an eight-box carbon cycle model. The results showed that since the terrestrial biospheric carbon sink was roughly offset by the deforestation source, the fossil fuel emission source was partitioned between the atmospheric and oceanic sinks. However, the partitioning ratio between the atmosphere and the ocean exhibited a change, that is, the carbon accumulation rate was faster in the atmosphere than in the ocean, due to a decrease in the so-called ocean buffering capacity. It was found that the ocean buffering capacity to take up excess CO$_2$decreased by 50% in terms of the buffer factor over the past 42 years. Accordingly, these results indicate that if the current CO$_2$emission trend continues, the future rate of increase in the atmospheric CO$_2$concentration will accelerate.

TLP Properties Evaluation of ESD Protection Device of GGNMOS Type for Conventional CMOS Process (Conventional CMOS 공정을 위한 GGNMOS Type의 ESD 보호소자의 TLP 특성 평가)

  • Lee, Tae-Il;Kim, Hong-Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.875-880
    • /
    • 2008
  • In this paper, we deal with the TLP evaluation results for GGNMOS in ESD protection device of conventional CMOS process. An evaluation parameter for GGNMOS is that repeatability evaluation for reference device($W/L=50\;{\mu}m1.0\;{\mu}m$) and following factors for design as gate width, number of finger, present or not for N+ gurad -ring, space of N-field region to contact and present or not for NLDD layer. The result of repeatability was showed uniformity of lower than 1 %. The result for design factor evaluation was ; 1) gate width leading to increase It2, 2) An increase o( finger number was raised current capability(It2), and 3) present of N+ gurad-ring was more effective than not them for current sink. Finally we suggest the optimized design conditions for GGNMOS in evaluated factor as ESD protection device of conventional CMOS process.