• Title/Summary/Keyword: current signal

Search Result 2,705, Processing Time 0.034 seconds

Dual Core Differential Pulsed Eddy Current Probe to Detect the Wall Thickness Variation in an Insulated Stainless Steel Pipe

  • Angani, C.S.;Park, D.G.;Kim, C.G.;Kollu, P.;Cheong, Y.M.
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.204-208
    • /
    • 2010
  • Local wall thinning in pipelines affects the structural integrity of industries like nuclear power plants (NPPs). In the present study, a pulsed eddy current (PEC) differential probe with two excitation coils and two Hall-sensors was fabricated to measure the wall thinning in insulated pipelines. A stainless steel test sample was prepared with a thickness that varied from 1 mm to 5 mm and was laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe were driven by a rectangular current pulse, the difference of signals from two Hall-sensors was measured as the resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The peak value increased as the thickness of the test sample increased. The results were measured at different insulation thicknesses on the sample. Results show that the differential PEC probe has the potential to detect wall thinning in an insulated NPP pipelines.

Analysis and Design of the In-Rush Current Protection Circuit for SSPA Power Supply (SSPA용 전원공급기의 돌입전류 보호회로 분석 및 설계)

  • Park, Sang-Hyun;Park, Dong-Chul;Kim, Dae-Kwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.5-11
    • /
    • 2008
  • Recently developed radars use the solid-state power amplifier to amplify the RF signal. The stability of RF signal directly depends on that of the electric power. So the stable and reliable electric power should be needed. When the electric power switch is tuned on for the first time in order to operate the radar system, the in-rush current is generated because of the capacitive characteristic. The excess in-rush current breaks the element. Therefore, the analysis about the in-rush current to design the electric power system is necessary. In this paper, modeling and simulation on the whole power system is carried out and the necessity of limiting the in-rush current is verified. After the analysis, the circuit to limit the in-rush current is designed and examined to verify the analysis. The circuit is good enough to limit the in-rush current.

Diminution of Current Measurement Error for Vector Controlled AC Motor Drives (교류전동기 벡터제어를 위한 전류 측정오차의 저감에 관한 연구)

  • Jung Han-Su;Kim Jang-Mok;Kim Cheul-U;Choi Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.32-36
    • /
    • 2004
  • In order to achieve high performance vector control, it is essential to measure accurate ac current. The errors generated from current path are inevitable, and they could be divided into two categories: offset error and scaling error. The current data including these errors cause periodic speed ripples which are one and two times of stator electrical frequency respectively. Since these undesirable ripples bring about bad influences to motor driving system, a compensation algorithm must be needed in the control algorithm of the motor drive. In this paper, a new compensation algorithm is proposed. The signal of the integrator output of the d-axis current regulator is chosen and processed to compensate the current measurement errors. The compensation of the current measurement errors is easily implemented to smooth the signal of the integrator output of the d-axis current regulator by subtracting the DC offset value or rescaling the gain of the hall sensor. Therefore, the proposed algorithm has several features: the robustness of the variation of the mechanical parameters, the application of the steady and transient state, the easy implementation, and less computation time.

  • PDF

Digital Current Control Scheme for Boost Single-Phase PFC Converter Based on Virtual d-q Transformation (가상 d-q 변환을 이용한 승압형 단상 PFC 컨버터의 디지털 전류 제어 방법)

  • Lee, Kwang-Woon;Kim, Hack-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.1
    • /
    • pp.54-60
    • /
    • 2020
  • A digital current control scheme using virtual d-q transformation for a boost single-phase power factor correction (PFC) converter is proposed. The use of virtual d-q transformation in single-phase power converters is known to improve current control performance. However, the conventional virtual d-q transformation-based digital current control scheme cannot be directly applied to the boost single-phase PFC converter because the current and average voltage waveforms of the inductor used in the converter are not sinusoidal. To cope with this problem, this study proposes a virtual sinusoidal signal generation method that converts the current and average voltage waveform of the inductor into a sinusoidal waveform synchronized with the grid. Simulation and experimental results are provided to show that the virtual d-q transformation-based digital current control is successfully applied to the boost single-phase PFC converter with the aid of the proposed virtual sinusoidal signal generation method.

The Enhancement of Learning Time in Fuzzy c-means algorithm (학습시간을 개선한 Fuzzy c-means 알고리즘)

  • 김형철;조제황
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2001.06a
    • /
    • pp.113-116
    • /
    • 2001
  • The conventional K-means algorithm is widely used in vector quantizer design and clustering analysis. Recently modified K-means algorithm has been proposed where the codevector updating step is as fallows: new codevector = current codevector + scale factor (new centroid - current codevector). This algorithm uses a fixed value for the scale factor. In this paper, we propose a new algorithm for the enhancement of learning time in fuzzy c-means a1gorithm. Experimental results show that the proposed method produces codebooks about 5 to 6 times faster than the conventional K-means algorithm with almost the same Performance.

  • PDF

Mold Oscillation Signal Detector of Eddy Current Mold Level Sensor (과류식(過流式) 연주(連鑄) Mold 탕면(湯面) 위치계(位置計)의 탕면진동신호(湯面振動信號) 검출방법(檢出方法))

  • Lee, Jin-Rak
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.37-38
    • /
    • 1988
  • In the continuous casting process, mold level sensor control system is very important for the quality of slab & bloom, in this paper, the principle of eddy current molr level sensor was studied and a method of mold oscillation signal detecting was purposed.

  • PDF

Spin Signals in Lateral Spin Valves with Double Nonmagnetic Bottom Electrodes

  • Lee, B.C.
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.81-84
    • /
    • 2008
  • Spin injection and detection in lateral spin valves with double nonmagnetic bottom electrodes are investigated theoretically. Spin-polarized current injected from a magnetic electrode is split to two bottom electrodes, and nonlocal spin signals between the other magnetic electrode and the nonmagnetic electrodes are calculated from drift-diffusion equations. It is shown that the spin signal is approximately proportional to the associated current in the electrode.

Specification-based Analog and Mixed-signal Circuits Test with Minimal Built-In Hardware Overhead (내장 하드웨어 오버헤드를 최소화한 Specification 기반의 아날로그 및 혼합신호 회로 테스트)

  • Lee, Jae-Min
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.633-634
    • /
    • 2006
  • A new specification-based analog and mixed-signal test technique using high performance current sensors is proposed. The proposed technique using current sensors built in external ATE has little hardware overhead in circuit under test and high testability without time consuming operation of test point placement algorithm.

  • PDF

Implementation of an Over-Current Relaying Algorithm Using 80C196KC (80C196KC를 이용한 과전류 계전 알고리즘 구현)

  • Kim, Hyung-Kyu;Lee, Bong-Hyun;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.495-496
    • /
    • 2007
  • An Over Current Relayng algorithm using 80c196kc micro processor was realized in this paper. This OCR Algorithm was verified with simulated fault signal. The fault signal was made by EMTP and realized by DOBLE to compare H/W test with S/W test. This simulations showed similar result between H/W and S/W test.

  • PDF

An Effective Mitigation Method on the Signal-Integrity Effects by Splitting of a Return Current Plane (귀환 전류 평면의 분할에 기인하는 신호 무결성의 효과적인 대책 방법)

  • Jung, Ki-Bum;Jun, Chang-Han;Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.3
    • /
    • pp.366-375
    • /
    • 2008
  • Generally a return current plane(RCP) of high speed digital and analog part is partitioned. This is achieved in order to decrease the noise interference between subsystem in PCBs(Printed Circuit Boards). However, when the connected signal line exists between each sub system, this partition will cause unwanted effects. In a circuital point of view, RCP partition has a bad influence upon signal integrity. In a EMI(Electromagnetic Interference) point of view, the partition of the return current plane becomes a primary factor to increase the radiated emission. Component bridge(CB) is usecl for the way of maintaining signal integrity, still specific user's guide doesn't give sufficient principle. In a view point of signal integrity, design principle of multi-CB using method will be analyzed by measurement and simulation. And design principle of noise mitigation will be provided. Generally interval of CB is ${\lambda}/20$ ferrite bead. In this study. When multi-CB connection is applied, design principle of ferrite bead and chip resistor is proved by measurement and simulation. Multi-connected chip resistance$(0{\Omega})$ is proved to be more effective design method in the point of signal integrity.