• Title/Summary/Keyword: current return path

Search Result 37, Processing Time 0.057 seconds

Impedance Calculation for Electric Railway System using modified Carson's Method (Modified Carson's Method를 이용한 전차선로의 Impedance 계산)

  • LEE Chunbae;KIM Wanggon;LEE Jongwoo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1403-1405
    • /
    • 2004
  • The method proposed by Carson contains indefinite complex integral which simulates earth return current. Although the Carson solution is proposed with power series, the solution is limited and valid at special range of frequency. We proposed a simplified Carson solution by modelling earth current path analytical method using ground transmission line return current. In this paper, we studied on trying to find the equivalent distance for earth current return path.

  • PDF

Analysis of Emission Characteristics of DC/DC Converter by Component Placement (부품배치에 따른 DC/DC 컨버터의 Emission 특성분석)

  • Park, Jin-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.639-643
    • /
    • 2018
  • As electronic systems become smaller and more portable, the need for power conversion continues to increase. In addition, system stability must be ensured from switching noise due to power conversion efficiency and power conversion system miniaturization. Therefore, countermeasures to reduce switching noise during power conversion are essential. In this paper, a DC/DC buck converter circuit is constructed, and the characteristics of switching noise generated when changing the parts layout in a four-layer printed circuit board (PCB) structure with a reference plane are compared and analyzed. In addition, switching noise characteristics were compared and analyzed through simulations when the parts layout was different in a two-layer PCB structure from which the reference planes were removed. As a result, it was confirmed that the radiated emissions characteristic is reduced by 12dB and the conducted emissions characteristic decreased by 7dB to 8dB, according to the current return path in the four-layer PCB structure. Thus, it was confirmed that the noise characteristics can be improved according to the configuration of the current return path when the power conversion circuit is designed.

The design of magnetic circuit of magnetostrictive actuator using finite element method (유한 요소 해석을 통한 자기변형 구동기 자기 회로 설계)

  • 이석호;박영우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.548-551
    • /
    • 2004
  • Magnetostrictive actuators have seen increasing use in fine positioning system because it has many advantages such as friction free, resolution of ${\mu}{\textrm}{m}$ or nm scale, and powerful output force. Usually, the magnetic circuit of magnetostrictive actuator has components which are flux return path, coil, and magnetostrictive material. It is classified in two types according to existence of the permanent magnet. The magnetic circuit having optimal performances transfer magnetic field which is obtained by providing input current at coil without energy loss. This paper described mathematical model of magnetic circuit for getting design variables. The modeling equation is obtained from the relations between flux and reluctance of the magnetic equivalent circuit. Also, finite element analysis has been used to study the performance of magnetic circuit according to change of design variables such as existence and shape of the permanent magnet, flux return path etc. The modification of dimensions enables us to optimize magnetic circuit.

  • PDF

A Study on Electrified Railway Traction System Impedance Calculation (전철선로 임피던스계산에 관한 연구)

  • Lee, Chon-Bae;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1407-1412
    • /
    • 2004
  • Impedance calculations of electric railway traction systems is essential to define characteristics and to design it. The self impedance is defined voltage drop rate per unit length, the mutual impedance is represented as a voltage induced to transmission line from transmission line. The self and the mutual impedance are influenced by ground return currents. The earth is considered as a semi-infinitely extended non-ideal conductor. The current of transmission line produces earth current induced magnetically and it flow through a path having minimum impedance. Carson proposed the impedance calculation formula using wave equations and magnetic field equations. Though the formula have an improper equation, that is still used as a standard impedance calculation method. This paper introduced an impedance calculation method that the complex depth of earth return method assumes that the current in conductor returns through an imagined earth depth path located directly under original conductor at a depth of. In this paper, we showed that this proposed method has a closed form and is easier than Carson's.

  • PDF

Analysis of Emission Characteristics of DC/DC Converter with different Parts Layout (부품배치가 다르게 제작된 DC/DC컨버터의 Emission 특성분석)

  • Park, Jin-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.179-183
    • /
    • 2019
  • The system stability must be ensured from the switching noise due to the power conversion efficiency and power conversion system miniaturization. Therefore, countermeasures to reduce switching noise during power conversion are essential. Thus, in the previous paper, we constructed the DC / DC Buck Converter circuit using MPQ4432 driver of MPS, and simulated the switching noise characteristics which occurs when the components are arranged differently in the 4 - layer PCB circuit structure with reference plane. In this paper, two different simulated circuits are fabricated and the characteristics of the conducted emission and the radiated emission are analyzed in the same way as the simulation. As a result, it was confirmed that the Conducted Emission characteristic was reduced by 2 ~ 9dB in the low frequency band and 6 ~ 7dB in the high frequency band depending on the configuration of the current return path. And the radiated emission characteristic is reduced by 9 dB. Conducted emission simulation results show that 6 ~ 7dB in the low frequency range and 2 ~ 9dB in the measurement result are somewhat different. In the high frequency band, it is confirmed that the experimental and simulation results are about 7dB. And Radiated Emission confirmed 12dB decrease in simulation, but confirmed decrease of 9dB in measurement result. It is confirmed that there is a slight difference in the amount of reduction, but the design of the power conversion circuit improves the noise characteristics according to the configuration of the current return path.

The Analysis of 4-Conductors Catenary System of AC Railway Feeding System and Calculation of Induced Voltage near Rail Track using the FDTD Method (교류 전기철도 급전계통 4도체군 전차선로 분석 및 FDTD 방법을 이용한 선로 주변 유도전압 계산에 관한 연구)

  • Ryu, Kyu-Sang;Yeom, Hyoung-Sun;Cho, Gyu-Jung;Lee, Hun-Do;Kim, Cheol-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1958-1964
    • /
    • 2016
  • AC railway feeding system use single phase to supply power to the railway vehicles. And the system use the rail track as a return current path, so that current flows in the rail. In this situation inductive interference on communication system and unsafe environment can appear on railway system. Therefore knowing the current distribution of catenary system and analysing the return current is required. In this study detail return current distribution was analyzed by modeling the catenary system as 4-conductors group. The distribution characteristics and trends of return current were studied by using the PSCAD/EMTDC and FDTD method that based on Maxwell equation was used to calculate the induced voltage. Simulation code was made by MATLAB. Using this study result data, we can suggest the proper installation location of digital device and these data can be used for additional studies related to return current or induced voltage as a base data.

Investigation for the Report of DC Traction Stray Current Protection (도시철도 전식방지 조사보고 현황)

  • Lee, Hyun-Goo;Ha, Tae-Hyun;Jung, Ho-Sung;Han, Moon-Sub;Bae, Jeong-Hyo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.281-285
    • /
    • 2008
  • Corrosion of metallic structures arises when an electric current flows from the metal into the electrolyte such as soil and water. The potential difference across the metal-electrolyte interface, the driving force for the corrosion current, can emerge due to a variety of temperature, pH, humidity and resistivity etc.. With respect to a given structure, a stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit. Stray currents are caused by other cathodic protection installations, grounding systems and welding posts, referred to as steady state stray currents. But most often traction systems like railroads and tramlines are responsible for large dynamic stray currents. This type of stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. This paper investigates the reports, which is made for protecting the electrical corrosion by the DC traction stray current before the construction period.

  • PDF

Comparison Analysis of Field Test Methods Based on Technical Criteria of Electrolytic Corrosion Protection in Urban Railway (도시철도 전식방지 기술기준에 따른 시험방법 비교분석)

  • Kim, Jae-Moon;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1885-1891
    • /
    • 2010
  • Recently metropolitan local governments is actively introducing urban railway's expand and light rail transit as a means of new transport system. DC electricity feeder system operating in the domestic urban railway is typically a feedback circuit consisted of the contact wire and electric railway vehicle via rail. But stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit with respect to a given structure. Stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper presents comparison analysis of field test methods based on criteria of electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems.

  • PDF

On-site Investigation of the Stray Current Condition in DC-Powered Subway System (지하철 직류 급전시스템의 표유전류 실태조사)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.373-375
    • /
    • 2003
  • The subway, a typical electrified transit, is operated by the 1500 V DC-powered system with the overhead positive feeder and the rails negative return. This return path would bring about considerable stray current circuits, that is, from the bottom of rails to sell and then to the station ground, unless the rail-to-soil resistance is sufficiently high. The stray current can cause electrolytic corrosion of subway metallic structures and adjacent underground utilities. In this paper, we reports on-site investigation of the stray current condition, especially influenced by drainage method. The drainage method including both forced drainage and polarized drainage, extensively adopted as a countermeasure for electrolytic corrosion of underground pipelines, was found out to exert a harmful influence upon rail components as well as the pipelines.

  • PDF

Multi-sensor Fusion based Autonomous Return of SUGV (다중센서 융합기반 소형로봇 자율복귀에 대한 연구)

  • Choi, Ji-Hoon;Kang, Sin-Cheon;Kim, Jun;Shim, Sung-Dae;Jee, Tae-Yong;Song, Jae-Bok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.250-256
    • /
    • 2012
  • Unmanned ground vehicles may be operated by remote control unit through the wireless communication or autonomously. However, the autonomous technology is still challenging and not perfectly developed. For some reason or other, the wireless communication is not always available. If wireless communication is abruptly disconnected, the UGV will be nothing but a lump of junk. What was worse, the UGV can be captured by enemy. This paper suggests a method, autonomous return technology with which the UGV can autonomously go back to a safer position along the reverse path. The suggested autonomous return technology for UGV is based on multi-correlated information based DB creation and matching. While SUGV moves by remote-control, the multi-correlated information based DB is created with the multi-sensor information; the absolute position of the trajectory is stored in DB if GPS is available and the hybrid MAP based on the fusion of VISION and LADAR is stored with the corresponding relative position if GPS is unavailable. In multi-correlated information based autonomous return, SUGV returns autonomously based on DB; SUGV returns along the trajectory based on GPS-based absolute position if GPS is available. Otherwise, the current position of SUGV is first estimated by the relative position using multi-sensor fusion followed by the matching between the query and DB. Then, the return path is created in MAP and SUGV returns automatically based on the MAP. Experimental results on the pre-built trajectory show the possibility of the successful autonomous return.