Study on Distortion Ratio Calculation of Park's Vector Pattern for Diagnosis of Stator Winding Fault of Induction Motor (유도전동기의 고정자 권선고장 진단을 위한 팍스벡터 패턴의 왜곡률 연산에 대한 연구)

  • Yang, Chul-Oh;Park, Kyu-Nam;Song, Myung-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.643-649
    • /
    • 2012
  • The diagnosis technique of stator winding faults based on Motor Current Signature Analysis(MCSA) was suggested. Park's vector pattern, the circle that is drawn by d-q transformed currents($i_d$, $i_q$), is widely used for stator winding faults detection. The current Distortion Ratio(DR), defined by the ratio of max axis and min axis of ellipse of Park's vector's pattern, was more simple and powerful method than the Park's vector pattern. In this study, a calculation method of distortion ratio of Park's vector pattern was suggested for auto diagnosis of stator winding short fault and usefulness of suggested calculation method of distortion ratio was verified through simulation using LabVIEW program.

Calculation of the Crack Length for a Pipe Specimen using the Modified Load Ratio Method (수정된 하중비법을 이용한 배관 시험편의 균열 길이 계산)

  • Choi, Jung-Hun;Huh, Yong;Koo, Jae-Mean;Seok, Chang-Sung;Park, Jae-Sil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.12
    • /
    • pp.1375-1382
    • /
    • 2009
  • The objective of this paper is to apply the load ratio method to the measurement of the crack length of the real scale pipe specimen. The load ratio method was modified and finite element analyses were performed to derive the relationship between the normalized compliance and the normalized crack length for the pipe specimen. In order to measure the crack length, the direct current potential drop method and the modified load ratio method were applied to the pipe test. The applicability of the modified load ratio method was confirmed by comparing the calculated crack length with the measured crack length from the pipe experiment.

Effect of thickness on properties of ZnO film prepared by direct current reactive magnetron sputtering method

  • Baek, C.S.;Kim, D.H.;Kim, H.H.;Lim, K.J.
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.403-406
    • /
    • 2012
  • Effect of thickness on ZnO properties including the compositional ratio and crystallinity has been systematically investigated using a variety of characterization tools of x-ray diffraction, field emission scanning electron microscopy, x-ray fluorescence and x-ray photoelectron spectroscopy. Interestingly, it was observed that ZnO films below 80 nm in thickness were in oxygen deficiency, while the oxygen ratio was increased in the films above the thickness, although the compositional ratio of ZnO film was not linearly varied with increasing film thickness. Also, ZnO crystallinity, which is characterized by (002) diffraction pattern, was clearly improved with increasing film thickness. The properties of ZnO film with different sputtering time and the nature of direct current reactive sputtering process were discussed in terms of compositional ratio, especially oxygen ratio in ZnO film.

Current Limiting Characteristics of Flux-lock Type SFCL according to Inductance Variation

  • Choi Hyo-Sang;Park Hyoung-Min;Cho Yong-Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.2
    • /
    • pp.87-89
    • /
    • 2006
  • We investigated the current limiting characteristics of flux-lock type superconducting fault current limiter(SFCL) according to inductance variation of coil 2. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting element in series. The operation of the flux-lock type SFCL can be divided into the subtractive and the additive polarity winding operations according to the winding directions between the coil 1 and coil 2. The current limiting characteristics in two winding directions were dependent of on the ratio of the number of turns of coil I and coil 2. The fault current increased when the number of turns of coil 2 increased in the subtractive polarity winding. On the contrary, the fault current decreased under the same conditions in case of the additive polarity winding.

Operating Current Characteristics of a kA Class Conductor for a SMES device (SMES용 kA급 초전도도체의 운전전류 특성)

  • 류경우;최병주;김해종;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.3-6
    • /
    • 2003
  • We have developed a small-sized superconducting magnetic energy storage (SMES) device, which provides electric power with high quality to sensitive electric loads. In large magnets such as the SMES magnets the stability, which is determined by several factors, e.g. conductors cooling condition and operating current, magnets winding structure, is a crucial problem. The effect of the cooling condition, the copper ratio, and the conductor's size upon the recovery currents was investigated experimentally. The results indicate that the recovery current characteristics of the strands vary considerably according to their insulation method. In the fully insulated strands with a low copper ratio, the recovery current densities range from 10 to 20 % of their engineering critical current densities. The recovery current density of the 30-conductor with a cooling channel is about a factor of 1.8 higher than that without a cooling channel.

  • PDF

The Eddy Current Method to Measure the Transformation Ratio in Metals (와전류 시험에 의한 금속의 변태율 측정에 관한 연구)

  • Wee, Sang-Bong;Han, Min-Koo;Paek, KI-Nam
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.5
    • /
    • pp.348-354
    • /
    • 1989
  • The metallurgical transformation ratios of metals have been evaluated by the eddy current method. Eddy current probes have been designed and applied to various standard samples. The equivalent impedance estimated from the eddy current measurement is closely related to the variation of transformation ratios in metals. It has been found that the variation of the impedance is relatively large in the samples where the transformation ratios of the samples are small. Both reactance and resistance increase when the transformation ratio is large. Sensitivities of eddy current test is increased with increasing frequencies and by inserting ferrite core the solenoid eddy probe. Our results have shown the implementation of eddy current measurement to the one-line nondestructive testing of metals.

  • PDF

A Study on the Current Gain Variation with the Emitter Size in AlGaAs/GaAs HBTs (AlGaAs/GaAs HBTs의 에미터 크기에 따른 전류 이득 변화에 관한 연구)

  • 정준오;이헌용;이태우;김일호;박문평;박성호;편광의
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.10-12
    • /
    • 1996
  • AlGaAs/GaAs Heterojunotion Bipolar Transistors (HBTs) with various emitter areas were fabricated and the device size dependence on the current gain was examined. With the different emitter areas, the passivated devices having the same peripheral length were fabricated and measured. The measured base current density in the Gummel plots shows an ideality factor of nearly 2. It is found that as the emitter area becomes small, the base current density with the ideality factor of 2 increases linearly, and as the emitter perimeter/area ratio becomes large, the surface recombination current density component increases. The current gain performance in AlGaAs/GaAs HBTs is mainly determined by either the larger emitter area or the smaller ratio of the emitter perimeter to the emitter area. These results will be compared with experimental works for GaInP/GaAs HBTs

  • PDF

Development of a Fault Diagnosis Algorithm on a High Current Cable of Arc Furnace (전기로 대전류 케이블 고장진단 알고리즘 개발)

  • Kim, Sang-Woo;Jang, Yu-Jin
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.3
    • /
    • pp.115-118
    • /
    • 2006
  • In the steel industry, a steel melting electric arc furnace is used to produce both carbon and alloy steels. Steel scrap which is charged into the furnace is heated by means of electric arc between graphite electrodes and the scrap. In this melting process, current is supplied to the furnace through HCC(high current cable) which connect the furnace and transformer. Four HCCs are assigned to each phase in our system to divide the current. Since a sudden cable breaking result in the shutdown of melting process, an aging detection of HCC is very important for both an improvement of productivity and cost reduction. In this paper, the aging of the HCC is estimated by using the current ratio between four HCCs.

A study on the CFT error reduction of switched-current system (전류 스위칭 시스템의 CFT 오차 감소에 관한 연구)

  • 최경진;이해길;신홍규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.5
    • /
    • pp.1325-1331
    • /
    • 1996
  • In this paper, a new current-memory circuit is proposed that reduces the clock feedthrough(CFT) error voltage causing total harmonic distortion(THD) increment in switched-current(SI) systems. Using PMOS transistor in CMOS complementary, the proposed one reduces output distortion current due to the CFT errorvoltage. A proposed current-memory is designed using a 1.2.mu.m CMOS process anda 1MHz sinusoidal signal having a 68.mu.A amplitude current is applied as input (sampling frequency:20MHz). It hasbeen shown from the simulation that the output distortion current effected by the CFT error voltage is reduced by approximately 10 times the error voltage of conventional one, THD is -57dB in case ofappling 1kHz frequency input signalwith 0.5 peak signal-to-bias current ratio.

  • PDF

Study on Characteristics of Leakage Current and Insulation Resistance for a Circuit According to Load Types (부하종류에 따른 회로의 누설전류 및 절연저항 특성 연구)

  • Han, Kyung-Chul;Choi, Yong-Sung
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.364-369
    • /
    • 2019
  • The ratios of compliant branch circuit of leakage current and insulation resistance were 68.4% and 90.8%, respectively at the lamp load, 64.6% and 96.5% at the heat load, 86.7% and 88.9% at the power load. Limit of residual current of the zero phase secondary current value at the zero phase primary current was 100 A when rated primary current 400 A more than. The reason why the ratio of branch circuit of the leakage current was less than the ratio of compliant branch circuit of the insulation resistance might be that the leakage current includes the capacitive leakage current and the zero phase current.