• 제목/요약/키워드: current overshoot

검색결과 112건 처리시간 0.032초

인덕턴스 변화에 강인한 계통연계형 인버터의 복소 벡터 전류제어기 (Complex Vector Current Control of Grid Connected Inverter Robust for Inductance Variation)

  • 이태진;조종민;신창훈;차한주
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1648-1654
    • /
    • 2016
  • This paper analyzes complex vector current control for the enhanced cross-coupling compensation in accordance with parameter variation in grid-connected inverter system, and verifies through simulation and experiment. Complex vector current control is performed in the synchronous reference frame through d-q transformation. It generates cross-coupling components with rotating nominal angular frequency. In general, cross-coupling elements are compensated by decoupling terms added to output of conventional decoupling PI controller. But, it is impossible to compensate them perfectly which transient response is especially deteriorated such as large overshoot and slow tracking, when variation of grid impedance or measurement error occurs. However, complex vector current control can improve stability and response characteristic of current control regardless of the situation as before. Decoupling controller and complex vector controller are represented through complex forms, and these controllers are analyzed by using frequency response in s-domain, respectively. It is verified that complex vector controller has more superior response characteristic than decoupling controller through MATALB, PSIM and experimental in 5kW grid-connected inverter when L filter parameter is varied from 1.1mH to increase double, 2.2mH.

과분극 자극에 대한 mouse 미수정란의 세포막저항과 세포막전압의 변화 (Changes of membrane resistance and membrane potentials by hyperpolarizing current stimulation in mouse unfertilized eggs)

  • 홍성근;김익현;조영덕
    • 대한수의학회지
    • /
    • 제31권1호
    • /
    • pp.33-40
    • /
    • 1991
  • For the observations of both the membrane properties and the excitability on the unfertilized eggs of female mice, changes of the membrane resistance and the membrane potential by hyerpolarizing current stimulation were recorded. As current-voltage relation was linear over the entire range (-180mV~+60mV), membrane resistance($R_m$) was calculated from the amplitude of electrotonic potential to a given stimulus current. Also the presence of anode-break excitation was confirmed. The results were as follows; 1. There was a linear relation between the membrane resistance and resting membrane potential, the expected input resistance was 61. 4M$\Omega$(resting membrane potential was $-18.9{\pm}8.7mV$, mean${\pm}$SD, n=30). 2. Transient depolarization with overshoot was generated just after hyperpolarizing current stimulus and showed the dependency of stimulus duration. 3. Transient depolarization lasted over 30ms, amplitude of these depolarization was increased by high $Ca^{{+}{+}}$(20mM) and inhibited by $Ca^{{+}{+}}$-antagonist, $Mn^{{+}{+}}$. 4. From the above results, it was suggested that the unfertilized mouse egg showed the characteristics of the excitable cell.

  • PDF

연산지연시간과 파라미터 변동에 강인한 UPS 인버터의 내부모델제어 (Internal Model Control of UPS Inverter with Robustness of Calculation Time Delay and Parameter Variation)

  • 박지호;계중읍;김동완;안영주;박한석;우정인
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.175-185
    • /
    • 2002
  • In this paper, a new fully digital current control method of UPS inverter, which is based on an internal model control, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The internal model controller is adopted to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. That is, the average current of filter capacitor is been exactly equal to the reference current with a time lag of two sampling intervals. Therefore, this method has an essentially overshoot free reference-to-output response with a minimum possible rise time. The effectiveness of the proposed control system has been verified by the simulation and experimental respectively. From the simulation and experimental results, the proposed system is achieved the robust characteristics to the calculation time delay and parameter variation as well as very fast dynamic performance, thus it can be effectively applied to the power supply for the critical load.

전동차용 PWM 정류기를 위한 집전기(pantograph) 접점상태 검출방법 및 비접촉상태를 고려한 PWM 정류기 제어기법 (Pantograph Detachment Detector and Control Scheme for a PWM rectifier Considering Pantograph Detachement Condition)

  • 송홍석;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.275-278
    • /
    • 2003
  • The pantograph contact can be disrupted due to irregularities in the motion. The pantograph detachment prohibits the current flow and makes the system uncontrollable. During the pantograph detachment period, the control error are accumulated by the integral property of the controller. The output of the controller, therefore, can be induced to be an extremely large value. When the pantograph is reattached, the extremely large output of the controllers causes a very high overshoot (or under-shoot) of the line current and the DC-link voltage. This work proposes a new method for detecting the pantograph bouncing conditions and designs a controller considering such conditions based on the pantograph bouncing detector.

  • PDF

High-Power-Factor Boost Rectifier with a Passive Energy Recovery Snubber

  • Kim, Marn-Go;Baek, Seung-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.668-676
    • /
    • 1998
  • A passive energy recovery snubber for high-power-factor boost rectifier, in which the main switch is described in terms of the equivalent circuits that are operational during turn-on and turn-off sequences. These equivalent circuits are analyzed so that the overshoot voltage across the main switch, the snubber current, and the turn-off transition time can be predicted analytically. The main switch combined with proposed snubber can be turned on with zero current and turned off at limited voltage stress. The high-power-factor boost rectifier with proposed snubber is implemented, and the experimental results are presented to confirm the validity of proposed snubber.

  • PDF

단위 역률을 갖는 직렬공진형 단상 정류기의 모드 변환 제어기법 (Switched Mode Control Technique for the Series Resonant Sigle-Phase Rectifier with Unity Power Factor)

  • 정영석;문건우;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.850-852
    • /
    • 1993
  • A buck-boost zero current switched(ZCS) series resonant AC to DC converter for the DC output voltage regulation together with high power factor is proposed. A dynamic model for this AC to DC converter is developed and an analysis for the internal operational characteristics is explored. With the proposed control technique, the unity power factor and the DC output voltage regulation without a current overshoot can be obtained.

  • PDF

CRA 기법을 이용한 PWM 컨버터의 강인제어기 설계 (CRA Based Robust Controller Design for PWM Converter)

  • 김수철;김형철;정교범;최재호
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.183-190
    • /
    • 2007
  • 본 논문에서는 PWM 컨버터의 강인제어기를 제안한다. 제안된 컨버터제어기는 DC 출력전압 제어를 위한 PI 제어기와 입력전류를 전원과 동상인 정현파로 제어하기 위해 오차공간에서 제어 문제를 해결한 전류제어기로 구성되어있다. 종래에는 전류제어기의 설계과정에서 소자의 스위칭주파수 및 디지탈제어기의 샘플링 주파수 등을 고려하여 제어기 게인값에 대한 해를 구하는 과정에서 시행착오 방법을 사용하여야 했다. 그러나 제안된 제어기는 CRA 기법을 적용하여 원하는 응답속도 및 오버슈트를 가지도록 최적의 게인값을 설정하도록 하였다. 먼저 CRA 기법을 적용한 전류제어기 알고리즘을 설명하고 PSiM 시뮬레이션 및 실험을 통하여 제안된 제어기의 타당성을 검증한다.

Feedback Buffer 구조 및 향상된 Regulation 특성을 갖는 LDO regulator (LDO Regulator with Improved Regulation Characteristics and Feedback Voltage Buffer Structure)

  • 정준모;박태룡
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.462-467
    • /
    • 2022
  • 피드백 버퍼 구조는 오버슈트 및 언더슈트 현상 및 출력전압의 레귤레이션을 완화하기 위해 제안된다. 기존의 LDO 레귤레이터는 일정한 부하전류의 변화로 인해 발생하는 레귤레이션 전압 변화를 겪는다. 따라서 패스 트랜지스터의 게이트 단자의 전류를 충방전함으로써 패스 트랜지스터의 동작 속도가 향상된다. 피드백 버퍼 구조를 갖는 LDO 레귤레이터는 3.3~4.5V에서 동작하며 출력 전압은 3V이며, 최대 150mA의 부하 전류를 가집니다. 시뮬레이션 결과에 따라 부하전류가 150mA까지 일정하게 변화하였을 때 6.2mV의 레귤레이션 값을 확보하였다.

Switched-Capacitor 지연 기법의 새로운 고해상도 DPWM 발생기를 이용한 Dynamic-Response-Free SMPS (Dynamic-Response-Free SMPS Using a New High-Resolution DPWM Generator Based on Switched-Capacitor Delay Technique)

  • 임지훈;박영균;위재경;송인채
    • 대한전자공학회논문지SD
    • /
    • 제49권1호
    • /
    • pp.15-24
    • /
    • 2012
  • 본 논문에서는 Switched-Capacitor 지연 기법의 새로운 고해상도 DPWM 발생기를 사용한 Dynamic-Response-Free SMPS를 제안한다. 제안된 회로는 Switched-Capacitor 지연 기법을 이용한 DPWM 발생기의 내부 커패시터 전압 기울기를 제어하는 방식으로 DPWM의 duty ratio를 결정한다. 제안된 회로는 컨버터의 피드백 전압과 기준전압을 비교하여 DPWM 발생기의 내부 캐패시터에 충방전되는 전류량을 제어하는 방식으로 출력전압 tracking이 가능하다. 따라서 제안된 회로는 기존 closed loop 제어 방식의 SMPS들에서 문제점이 되고 있는 동적 응답특성을 고려할 필요가 없으며, 출력 전압에 overshoot/undershoot로 인한 ringing 현상이 발생하지 않는다는 큰 장점을 가진다. 제안된 회로는 1MHz~10MHz까지 스위칭주파수를 사용자가 선택할 수 있으며, 100MHz의 내부 제어 동작 주파수로 10MHz 최대 스위칭 주파수(DPWM) 발생이 가능하다. 100MHz의 내부 제어 동작 주파수를 사용하여 10MHz 스위칭 주파수 발생시 소모되는 내부 회로의 최대 전류는 2.7mA이며, 출력 버퍼를 포함한 전체 시스템의 전류 소모는 15mA이다. 제안된 회로는 0.125%의 DPWM duty ratio 해상도를 가지고 부하에 최대 1A까지 전류공급이 가능하며, 최대 리플 전압은 8mV이다. 동부하이텍 BCD $0.35{\mu}m$ 공정 파라미터를 이용해 시뮬레이션을 수행하여 제안된 회로의 동작을 검증하였다.

Transient Improvement Algorithm in Digital Images

  • 권지용;장준영;이민석;강문기
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2010년도 하계학술대회
    • /
    • pp.74-76
    • /
    • 2010
  • Digital images or videos are used in modern digital devices. The resolution of HDTV in digital broadcasting system is higher than that of previous analog systems. Also, mobile phone with 3G can provide images as well as video streaming services in realtime. In these circumstances, the visual quality of images has become an important factor. We can make image clear by transient improvement process that reduces transient in edges. In this paper, we present an transient improvement algorithm. The proposed algorithm improves edges by making smooth edge to steep edge. Before performing transient improvement algorithm, edge detection algorithm should be operated. Laplacian operator is used in edge detection, and the absolute value of it is used to calculate gain value. Then, local maximum and minimum values are computed to discriminate current pixel value to raise up or pull down. Compensating value that gain value multiplies with the difference between maximum (or minimum) value and current pixel value adds (or subtracts) to current pixel value. That is, improved signal is generated by making the narrow transient of edge. The advantage of proposed algorithm is that it doesn't produce shooting problem like overshoot or undershoot.

  • PDF