• 제목/요약/키워드: current measurement

검색결과 3,839건 처리시간 0.033초

레이저 표면경화 공정에서 경화층깊이의 실시간 측정을 위한 실험적 연구 (An experimental study on the in-process measurement of case depth for LASER surface hardening process)

  • Woo, H.G.;Park, Y.J.;Han, Y.H.
    • 한국정밀공학회지
    • /
    • 제10권2호
    • /
    • pp.66-75
    • /
    • 1993
  • This paper proposes a monitoring method for nondestructive and in-process measurement of the case depth in LASER surface heat treatment process. The method is essentially an eddy-current method, and measures sensing coil's electrical impedance which varies with the changes of the material microstructure due to hardening. To investigate te validity of the proposed method a series of experiments were performed for various hardning depths. The results show that the relationship between the eddy- current sensor output and the changes in case depth is almost linear. This indicates that the eddy-current measuring method can be used as one of the possible monitoring method for mesauring the hardened depth in LASER heat treatment processes.

  • PDF

가스절연기기 내부의 금속 이물질에 의한 초고속 부분방전량 및 전류 측정 (Ultra-fast meseurement of partial discharge current due to conducting particle in Gas-insulated System (GIS))

  • 박기준;구선근;윤진열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.160-164
    • /
    • 2002
  • A special discharge cell containing a free conducting particle was used to generate the discharges in $SF_6$. The analog bandwidth of the measurement system exceeded 5 GHz. The measured signals were processed to compensate for the response of the measurement system. The discharge current rise time was in the range of 70 ps, while its full-width half-maximum was 120 ps. Single and double current pulses of positive and negative polarities were measured. Likewise, these pulses were compared with the measurement obtained using a conventional partial discharge detector of the IEC60270 type

  • PDF

대전류 측정용 마이크로-옴 분류기의 교정에 관한 연구 (Calibration of micro-ohm shunt used for large current measurement)

  • 김민규;김익균;정주영;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1862-1864
    • /
    • 2002
  • In this study, micro-ohm shunts with rated ac current of 2, 20, 80kA intended for use as an approved system for ac current measurement were calibrated according to IEC 60060. The scale factor and linearity were determined by comparison with the reference measuring system. Measurements of temperature rise due to the rated current was also investigated to analyze a temperature effect. One of the main goals was the determination of the measurement uncertainty of the shunt. The expanded uncertainty of the scale factor for the complete measuring system was satisfied with the STL(Short-circuit Testing Liaison) guide recognized tentatively.

  • PDF

자동차 Power Seat 용 DC Motor의 소음 진동 자동 평가에 대한 연구 (Automatic Measurement of Noise and Vibration for Power seat DC motor in the vehicle)

  • 한형석;정의봉;김건혁;송도훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1142-1147
    • /
    • 2002
  • For the evaluation of the DC motor noise and vibration, usually it is rely on human feeling because some kinds of noise are not definitely represented by measurement Instrument such as sound meter. But when we consider time signal of the noise and vibration. It is possible to represent them. And in this paper. it is suggested to study output current shape of the motor because it Is the source to make speed and torque variation of the motor. If the current shape is not stable. it makes operating state of the motor unstable and produces noise and vibration. By analyzing signal at time and frequency of noise and vibration and current shape. it is possible to automation of the noise and vibration measurement in the Production line.

  • PDF

OLED의 노화에 따른 밝기 감쇠측정 시스템 (Implementation of OLED's Brightness Aging Measurement System)

  • 윤현돈;정홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.439-440
    • /
    • 2006
  • This paper presents precise measurement system for the lifetime of OLED. The proposed system collects the data for using voltage drop across the OLED Panels, and then the computer program makes an analysis of the data. In this process of measurement, the current across OLED material must be amplified because the current is very small. However, amplifying the current causes the amplification of noise. Therefore, the proposed system measures the current using an algorithm which minimizes the noise.

  • PDF

태양광 패널 재사용을 위한 가변 정전류 기반의 효율 측정장치에 관한 연구 (Research on Variable Constant Current Efficiency Measuring Device for Solar Panel to Reuse)

  • 우상진;김대헌;이재진;권오민
    • 대한임베디드공학회논문지
    • /
    • 제18권1호
    • /
    • pp.9-17
    • /
    • 2023
  • This paper relates to the development of a device for measuring the efficiency of a solar panel based on a variable constant current, and proposed a standard for reuse of the solar panel. By applying a variable constant current circuit to a solar panel efficiency measuring device, it was easy to apply a maximum power point tracking (MPPT) algorithm. In addition, a load dispersion method was applied to measure the efficiency of a high-capacity solar panel. and it is possible to solve a problematic thermal runaway during a MOSFET parallel operation by applying the load dispersion method. As a result of the experiment, the solar panel efficiency measuring device was able to accommodate a large solar panel of 350W, which is the maximum measurement goal. In this paper, the validity was confirmed through the 310W solar panel efficiency measurement experiment collected after removal.

소형 퓨즈에 흐르는 전류 측정용 광섬유 패브리-페로 간섭형 센서 (Fiber Fabry-Perot interferometric sensor for the measurement of current flowing into a small fuse)

  • 박성순;박재희;김경찬
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.91-95
    • /
    • 2005
  • A fiber Fabry-Perot interferometric sensor for the measurement of current flowing into a small fuse have been studied. The proposed current sensor was fabricated with a fiber Fabry-Perot interferometer attached close to a fuse line inside a small fuse. The fiber Fabry-Perot interferometer used in the experiment had the 10 mm cavity length and the 3.5 % reflectance mirrors. The phase shift of the output signal of the current sensor was proportional to the square of current applied to the fuse and the sensitivity of the current sensor was 0.87 degree/$mA^{2}$. The experiment results show that this sensor can be used for measuring current flowing into the fuse.

주축모터 전류를 통한 절삭력의 간접 측정 및 절삭력 추종제어 (Indirect Cutting Force Measurement and Cutting Force Regulation Using Spindle Motor Current)

  • 김기대;권원태;주종남
    • 한국정밀공학회지
    • /
    • 제14권10호
    • /
    • pp.15-27
    • /
    • 1997
  • Quasti-static cutting force variations in milling process are measured indirectly using spindle motor current. Quasi-static sensitivity of the spindle motor current is higher than that of the feed motor current. Magnitude of the spindle motor current is independent of cutting direction. The linear relationship between the cutting force and the spimdle motor RMS current at various spindle rotational speed is obtained. Frequency/ Voltage(F/V) converter voltage is measured to identify the spindle speed and to determine the cutting force at various spindle speeds. Overload on the tool during milling process can be detected using the proposed indirect cutting force measurement. Based on these measurements, cutting force is regulated at a constant level by feedrate control.

  • PDF

Ultrafine Particle의 독성, 측정방법 및 관리 (Ultrafine Particle Toxicities, Current Measurement Techniques and Controls)

  • 이수길;김성수
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.203-215
    • /
    • 2010
  • This study is an overview of toxicities and measurement techniques of ultrafine particles (UFPs), and their exposure controls. UFPs are ubiquitous in many working situations. Exposure to UFPs is possibly causing adverse health symptoms including cardio-respiratory disease to humans. In order to measure exposure levels of airborne UFPs, there are current available measurement guidelines, instruments and other techniques (i.e. contour mapping, control banding). However, these risk assessment techniques including measurement techniques, controls and guidelines are dependent on background levels, metrics (e.g. size, mass, number, surface area, composition), environmental conditions and controls. There are no standardized measurement methods available and no generic and specific occupational exposure standards for UFPs. It is thought that there needs to be more effort to develop Regulations and Exposure Standards for generic UFPs should be based on more exposure data, health surveys, toxicological data and epidemiological data. A carefully considered hierarchy of controls can also reduce the maximum amount of airborne UFPs being emitted from diverse sources in industries.