• 제목/요약/키워드: current measurement

검색결과 3,839건 처리시간 0.035초

DSP를 이용한 변류기 보상 알고리즘 (CT compensating algorithm Based on a Digital Signal Processor)

  • 강용철;이병은;소순홍;황태근;이지훈;차선희;김연희;장성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.255-257
    • /
    • 2005
  • This paper proposes a compensating algorithm of a measurement torrent transformer (CT) using DSP. The core flux is calculated and then magnetizing current is estimated in accordance with the flux-magnetizing current curve. The core loss current is obtained with the core loss resistance and the secondary voltage. The correct secondary current is estimated by adding the exciting current to the measured secondary current. The performance of the proposed algorithm was tested using EMTP generated data. The experiment on the real CT was conducted using the prototype compensated system based on a digital signal processor. The results indicate that the algorithm can increase the accuracy of the measurement CT significantly.

  • PDF

PBLG의 자격반응에 관한 연구 (A Study on the Stimulus Reaction of PBLG)

  • 김병근;장헌;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.719-722
    • /
    • 2002
  • The Displacement current measurement system used in this experiment because detecting the dynamic behavior of monolayers at the air-water interface is possible. It basically consists of a film balance, a pair of electrodes connected to each other through a sensitive ammeter. Here, one electrode is suspended in air and the other electrode is placed in the water. PBLG phase transformation measured by Maxwell-displacement-current-measurement method in surface of the water. Measured (surface pressure, displacement current and dipole moment) of monolayers of PBLG on the water surface. We measured displacement current that occur when changed temperature. Could know that displacement current is proportional in increase of temperature and great as experiment result.

  • PDF

전류인가시간에 따른 Bi-2223 테이프의 과전류 통전특성 측정 (Measurement of Bi-2223 Tape's properties at Various Duration of the Over Current)

  • 이광연;이희준;차귀수;이지광
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.257-260
    • /
    • 2003
  • Bi-2223 tape is one of the most widely used HTS tapes for power application. This paper presents the basic properties such as temperature and resistivity rise of the Bi-2223 tape which is exposed to the over current. Temperature and resistivity were measured by E-type thermocouple and voltage taps. Results of the measurement showed that rise of voltage depended on the magnitude of the over current until several times of the rated current. When the current largely exceeded the rated current, rise of voltage depended on the magnitude of the resistivity of the Ag matrix because temperature of the matrix increased to a great extend.

  • PDF

와전류 시험에 의한 금속의 변태율 측정에 관한 연구 (The Eddy Current Method to Measure the Transformation Ratio in Metals)

  • Wee, Sang-Bong;Han, Min-Koo;Paek, KI-Nam
    • 대한전기학회논문지
    • /
    • 제38권5호
    • /
    • pp.348-354
    • /
    • 1989
  • The metallurgical transformation ratios of metals have been evaluated by the eddy current method. Eddy current probes have been designed and applied to various standard samples. The equivalent impedance estimated from the eddy current measurement is closely related to the variation of transformation ratios in metals. It has been found that the variation of the impedance is relatively large in the samples where the transformation ratios of the samples are small. Both reactance and resistance increase when the transformation ratio is large. Sensitivities of eddy current test is increased with increasing frequencies and by inserting ferrite core the solenoid eddy probe. Our results have shown the implementation of eddy current measurement to the one-line nondestructive testing of metals.

  • PDF

유기단분자막의 전극거리에 따른 전류 측정 (The Current Measurement by Electrode Distance of Organic Monolayers)

  • 이경섭;전동규;오재한;강용철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 1998
  • We have investigates a surface pressure, a displacement current and a charge measurement by distance of between electrode 1 and water surface of organic monolayers. And the displacement current was generated during compression of Arachidic acid mono1ayers at a air-water interface. The result from our work show that the displacement current of a Langmuir(L) film for Arachidic acid monolayers has the different maximum points according to the electrode distance. We are known that the displacement current and a charge was generated in inverse proportion to electrode distance d.

  • PDF

교류 전동기 구동용 불연속 PWM 인버터의 전류 샘플링 오차 해석 및 보상 (Analysis and Compensation of Current Sampling Error in Discontinuous PWM Inverter for AC Drive)

  • 송승호;손요찬;설승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권9호
    • /
    • pp.517-522
    • /
    • 1999
  • This paper addresses the issue of current sampling in a high performance AC drive system fed by a discontinuous PWM inverter. The effect of the sampling error due to the measurement delay produced by an input stage low pass filter and an A/D converter is described in the case of discontinuous PWM. To compensate for the sampling error, a method to estimate the delay time of the whole measurement system based on the measured current is proposed and its effectiveness is verified by experimental results. The proposed algorithm can automatically estimate the system delay introduced by the low pass filter and the A/D converter at the commissioning stage. By delaying the current sampling by the estimated value, experimental results indicate that more than 50% reduction of current ripple can be achieved.

  • PDF

접지임피던스 측정에 관한 전류보조전극 거리 및 주파수의 영향 분석 (Analysis for Ground Impedance Measurement Influenced by Distance of Current Probe and Frequency)

  • 길형준;김동우;김동욱;이기연;문현욱;김향곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 2009
  • This paper describes the analysis for ground impedance measurement influenced by distance of current probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 5[m] to 20[m] and the measuring frequency was ranged in 55[Hz], 128[Hz], 342[Hz], and 513[Hz]. The results could be help to determine the position of current probe when the ground impedance was measured at grounding system.

  • PDF

지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치 (DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE)

  • 배정효;하윤철;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF

2상 유도전동기용 벡터제어 인버터를 위한 전류측정 오차 보상 방법 (Compensation Method of Current Measurement Error for Vector-Controlled Inverter of 2-Phase Induction Motor)

  • 이호준;윤덕용
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1204-1210
    • /
    • 2016
  • The phase currents must be accurately measured to achieve the instantaneous torque control of AC motors. In general, those are measured using the current sensors. However, the measured current signals can include the offset errors and scaling errors by several components such as current sensors, analog amplifiers, noise filter circuits, and analog-to-digital converters. Therefore, the torque-controlled performance can be deteriorated by the current measurement errors. In this paper we have analyzed the influence caused by vector control of 2-phase induction motor when two errors are included in measured phase currents. Based on analyzed results, the compensation method is proposed without additional hardware. The proposed compensation method was applied vector-controlled inverter for 2-phase induction motor of 360[W] class and verified through computer simulations and experiments.

페러데이 효과를 이용한 특고압 직류전송용 광전류 센서 구현 (Implantation of DC Optical Current Sensor Based on Faraday Effect for HVDC)

  • 김광택;정대원;김영수
    • 센서학회지
    • /
    • 제28권3호
    • /
    • pp.187-190
    • /
    • 2019
  • We proposed and demonstrated DC(direct current) optical current sensor based on Faraday effect for HVDC(high voltage direct current). The RIG((Bi1.3Gd0.43Y1.27)Fe5O12) was adopted as Faraday device because of its high Verdet constant and good thermal stability. The differential amplification scheme for signal processing was present. The sensor showed high linear response for the input current. Measurement range of the sensor was 0~200A and measurement error was less than 1%.