• 제목/요약/키워드: current interruption

검색결과 201건 처리시간 0.034초

170kV 50kA 콘덴서 불용형 SF6 가스절연개폐기의 극간 전계해석 (Electric Field Analysis of 170kV 50kA Class SF6 GCB Without Capacitor)

  • 송태헌;배동진;최영찬;김익모;윤치영;강종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.351-353
    • /
    • 1999
  • In this paper, electric field analysis of 170kV class GCB is carried out. Considering the movement of arcing contacts during circuit interruption, electric field analysis between moving and fixed contacts is performed with changing the stroke length. From analysis results, electric field stresses are high at stationary arcing contact, moving arcing contact and varies at changing nozzle shapes. Specially, the stationary arcing contact shape has an significant effect on the capacitive small current interruption and the reduction of the electric field stress at this area is important. Varying the shape of stationary arcing contact, electric field analysis is carried out and the optimal shpae of the fixed arcing contact where the electric field stress is low is designed.

  • PDF

$SF_6$ 가스절연개폐기의 냉가스유동해석과 전계해석을 기초로 한 차단성능평가 (Circuit Interruption Performance Evaluation of $SF_6$ GIS Based Results of Cold Flow and Electrical Field Analysis)

  • 배동진;송태헌;최영찬;이기주;김익모;강종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.89-91
    • /
    • 1999
  • The performance of circuit interruption of $SF_6$ puffer cylinder type gas circuit breaker(GCB) has been evaluated from the results of electrical insulation strength which is depend on material property, such as $SF_6$ gas density in circuit breaker tank. In order to determine circuit breaker dimension in the safety criteria. electrical field analysis has been done by finite element method. Gas density of concerned area in the circuit breaker has been calculated. In order to predict small current break performance, Electrical field analysis result must be calculated based the results of density from cold flow dynamics. The proposed method has been carried out and evaluated for 362kV class high voltage GIS.

  • PDF

사고전압 감지형 아크차단 제어회로 개발 (Development of Arc Fault Interruption Control Circuit of Fault Voltage Sensing Type)

  • 곽동걸;변재기;이봉섭
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.1-5
    • /
    • 2013
  • 본 논문은 사고전압 감지형의 아크차단 제어회로에 대한 연구로써, 전기사고 발생 시 선간전압의 순간적인 전압감쇠를 감지하여 기존 차단기를 동작시키는 전압감지형 전기화재 예방장치이다. 현재 저압배전 계통에 사용중인 누전차단기, 배선용차단기 그리고 RCD 등은 전기화재의 주요 요인인 아크사고에 대해 보호능력이 없는 것으로 분석된다. 본 논문에서는 이러한 문제점들을 개선하기위하여 이전의 전류감지에 의한 아크사고 차단방식이 아닌 사고발생 시 전압파형의 왜곡을 이용한 새로운 전압감지형 아크차단 제어회로를 개발하여 전기화재를 예방하고자 한다. 제안한 아크차단 제어회로는 소형 경량으로 제작되는 장점과 다양한 동작분석을 통하여 그 실용성을 검증하였다.

멀티캐스팅을 지원하는 프록시 모바일IPv6 네트워크에서 빠른 도메인간 핸드오버 기법의 분석적 접근법 (Analytical Approach of Fast Inter-Domain Handover Scheme in Proxy Mobile IPv6 Networks with Multicasting Support)

  • 유세원;정종필
    • 정보처리학회논문지C
    • /
    • 제19C권2호
    • /
    • pp.153-166
    • /
    • 2012
  • 모바일 네트워크에서 멀티캐스트서비스의 이용량 증가로 MN(이동단말)에게 끊김없이 멀티캐스트 서비스를 전송하는 통신이 중요한 통신 형태가 요구될 것이다. 본 논문에서 IETF에서 표준화가 진행중인 PMIPv6(Proxy Mobile IPv6)에서 MLS(Multicast Listener Support)에 대한 현재의 문제점을 지적하고, 네트워크 기반의 이동성관리 기법인 PMIPv6 네트워크에서 도메인간 고속 멀티캐스트 핸드오버 절차를 제안한다. 제안된 도메인간 고속 멀티캐스트 핸드오버 절차에서는 MN의 컨텍스트를 사용하여 멀티캐스트 관리를 최적화한다. 제안된 고속 멀티캐스트 핸드오버 절차를 기본적인 것과 해석 모델링을 통하여 비교분석하고, 도메인간 핸드오버의 경우에 제안된 도메인간 고속 멀티캐스트 핸드오버 절차가 기본적인 것과 비교하여 서비스 단절 시간과 전체 네트워크 오버해드가 상당히 감소한다는 것을 보여준다.

PTFE 노즐로부터 발생하는 용삭가스를 고려한 스위칭 아크 해석 (Numerical Analysis of Switching Arcs with the Ablation of PTFE Nozzles)

  • 이원호;김홍규;이종철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1536-1537
    • /
    • 2011
  • The high-voltage circuit breaker plays an important role in the electrical system because there has been a need for suitable switching devices capable of initiating and interrupting the flow of the electric fault current. It continues as the contacts recede from each other and as the newly created gap is bridged by a plasma. The arc plasma happens inside the insulation nozzle of SF6 self-blast interrupter which is newly developed as the next-generation switching principle. The ablation of PTFE nozzle is caused by this high temperature medium, the PTFE vapor from the nozzle surfaces flows toward the outlets and the pressure chamber. The vapor makes the pressure of the chamber increased by heat and mass transfer from the arcing zone. Because the rate of ablation depends on the magnitude of applied current, it decreases when the current goes to zero. The compressed gas inside the chamber flows reversely toward the arc plasma during this moment. According to this principle, the arc can be cooled down and the fault current can be interrupted successfully. In this study, we calculate arc plasmas and thermal-flow characteristics caused by fault current interruption inside a SF6 self-blast interrupter, and to investigate the effect of PTFE ablation on the whole arcing history.

  • PDF

가스차단기 최적설계를 위한 $SF_6$ 아크 플라즈마 CAE 해석 (CAE Analysis of $SF_6$ Arc Plasma for a Gas Circuit Breaker Design)

  • 이종철;안희섭;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.365-368
    • /
    • 2002
  • The design of industrial arc plasma systems is still largely based on trial and error although the situation is rapidly improving because of the available computational power at a cost which is still fast coming down. The desire to predict the behavior of arc plasma system, thus reducing the development cost, has been the motivation of arc research. To interrupt fault current, the most enormous duty of a circuit breaker, is achieved by separating two contacts in a interruption medium, $SF_{6}$ gas or air etc., and arc plasma is inevitably established between the contacts. The arc must be controlled and interrupted at an appropriate current zero. In order to analyze arc behavior in $SF_{6}$ gas circuit breakers, a numerical calculation method combined with flow field and electromagnetic field has been developed. The method has been applied to model arc generated in the Aachen nozzle and compared the results with the experimental results. Next, we have simulated the unsteady flow characteristics to be induced by arcing of AC cycle, and conformed that the method can predict arc behavior in account of thermal transport to $SF_{6}$ gas around the arc, such as increase of arc voltage near current zero and dependency of arc radius on arc current to maintain constant arc current density.

  • PDF

Development of 460V/225A/50㎄ Contact System in Current Limiting Molded Case Circuit Breakers

  • Park, Young-Kil;Park, Chan-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권4호
    • /
    • pp.165-172
    • /
    • 2003
  • Low voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. This paper is focused on understanding the interrupting capability, more specifically of the contacts and the arc runner, based on the shape of the contact system in the current molded case circuit breaker (hereafter MCCB). Moreover, in order to improve the interrupting capability of the circuit breaker, the estimation and analysis of the interrupting capability, based on the 3-D magnetic flux analysis, were developed. Furthermore, this paper also presents results of the estimation and analysis of the interrupting capability when applied to different model breakers. In addition, this paper analyzes the efficiency of the interrupting tests by forming false current paths consisting of a three-division cascade arc runner in the contact system. With regards to the interrupting test, there is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by the current and flux density be present. Based on the results of this study, this paper presents both computational analysis and test results for the newly developed MCCB 460V/225A/50㎄ contact system.

800kV, 50kA 차단기의 전절연 검증을 위한 시험방법 검토 (Review about test method for the full-insulation verification of circuit breaker rated on 800kV, 50kA)

  • 박승재;서윤택;윤학동;김용식;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.569-571
    • /
    • 2005
  • In case of dead-tank circuit breaker with the earthed enclosure, the dielectric performance for phase to ground should be verified under the hot-gas condition produced by the current interruption. This test condition is required in breaking test duties with the rated short-circuit current and rated voltage. And, KERI has completed the reinforcement of the synthetic testing facilities and these facilities have the testing capacity which enables the full-pole testing for 800kV circuit breaker by adopting the series voltage injection method. So, this paper introduced the test circuit and procedures about the full-pole and the multi-part testing method which was devised to estimate the full -insulation of phase-to-ground for the multi-pole and dead-tank circuit breaker.

  • PDF

향상된 HS-DSCH serving cell change procedure 제안 (proposals for enhancing the current HS-DSCH serving cell change procedure for UE mobility)

  • 정영훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.273-274
    • /
    • 2008
  • According to current RRC procedures, network does not know either how long it will take the RRC reconfiguration message (such as Physical Channel Reconfiguration (PCR)/Transport Channel Reconfiguration (TCR)/Radio Bearer Reconfiguration (RBR)) to be transmitted over the source cell or how long the UE will take to reconfigure on receiving the message, it has to assume the worst-case. Thus, it typically indicates a conservative activation time, leading to potentially large interruption for voice traffic, particularly if the source cell signal strength has degraded. This proposals allow the UE to receive the serving cell related information (carried today in PCR/RBR/TCR message) in an Active Set Update message.

  • PDF

전산수치해석을 통한 가스차단기의 차단성능 평가 (Evalution of Current interrupting capability in GCB by computational approach)

  • 최영길;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1677-1681
    • /
    • 2002
  • A computational approach of the arc quenching process in GCB was developed. it is capable to calculates the thermodynamic quantities of the gas as a function of time taking into account of all spaces concerned with the arc quenching. Basically using so-called FLIC method, this program adoptes 'Simplified Enthalpy Arc Model', which is somewhat modified. And, to examine whether our works were done properly, it was simulated the whole process of the arc quenching that is based on self-flow generation phenomena/current interruption in a thermal expansion type circuit breaker. This program was verified by experiments, both showed fairly good agreement.

  • PDF