• 제목/요약/키워드: current detection

검색결과 2,477건 처리시간 0.033초

데이터 처리 및 무선통신기능을 갖는 회로차단기 개발 연구 (Development of the Circuit Breaker with Data Processing Function and Wireless-communication Function)

  • 김기현;이상익;신성수;배석명;주남규
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1617-1621
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the circuit breaker which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment is able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the circuit breaker and obtained certification. And we tested the over current, leakage current and arc under the normal condition. This paper will be used to the data for development an cabinet panel which is able to monitor the actual loads.

계통연계 분산전원의 새로운 단독운전 판별기법 (Novel Islanding Detection Method for Distributed Generation Interconnected with Utility Grid)

  • 배병열;이두영;고종선;최남섭;한병문
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.65-72
    • /
    • 2008
  • This paper describes the development of a novel islanding detection method, which uses the signal cross-corelation scheme between the injected reactive current and the power frequency deviation. The existing method, which injects the reactive current of 2.5-5% to the rated current and detects the frequency deviation directly, brings about lowing the power quality due to the harmonic pollution. The proposed method eliminates the weak point of the existing method, because it injects the reactive current less than 1% to the rated current. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 10kVA hardware prototype. The proposed method can detect the islanding status effectively without lowing the power quality of interconnected distributed generation system.

전류센서를 이용한 BLDC 전동기 권선 결함 검출 방법 비교 (Comparison of Fault Detection Methods for the BLDC Motor Using the Current Sensor)

  • 이재현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권8호
    • /
    • pp.1115-1127
    • /
    • 2010
  • 권선 결함을 검출하기 위하여 다양한 방법들이 적용되어 왔는데, 최근에는 전류 신호를 이용한 결함 검출 방법에 대한 연구들이 많이 이뤄지고 있다. 전류 신호는 전동기의 권선 결함에 대한 주요한 정보를 담고 있으며 본 연구에서도 BLDC 전동기의 권선 단락을 검출하기 위하여 전류 신호로부터 결함 특징을 추출하는 방법을 적용하였다. 본 연구를 통해 전류 신호로부터 결함 특징을 추출하는데 가장 적절한 방법을 시뮬레이션 및 실제 측정 데이터를 통해 비교 평가하고자 하였다.

계통연계형 태양광발전시스템을 위한 단독운전 검출에 관한 연구 (A Study on the Islanding Detection for Grid Connected Photovoltaic System)

  • 이기제;김민;이진섭;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.555-558
    • /
    • 2002
  • The general ways of the anti-islanding can be classified into the active method and passive method. The passive method which use only the voltage information when power failure occurs has much possibility of the wrong detection. And the active method detects the change of the voltage frequency as instantaneously changing the frequency of the inverter output current. Therefore, in this paper, the method to inject arbitrary order harmonics into controlled current is proposed. In this method islanding can be detected by measuring the amount of load voltage of injected harmonics order. And as a current control method predictive control method is used, which make actual current accurately to track reference current by Instantaneously computing converter output voltage and has fast response in transient state. This parer proposed method was verified by simulation.

  • PDF

A Modified Sapce-Vector PWM Inverter without Phase Current Sensors

  • Joo, Hyeong-Gil;Shin, Hwi-Beom;Oh, In-Hwan;Youn, Myung-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권4호
    • /
    • pp.86-91
    • /
    • 1997
  • A method of detecting the three phase currents for a voltage-fed pusle width modulated(PWM) inverter is proposed, where only one current sensor is utilized on the dc-link. The proposed method has the constant sampling time by employing he modified space-vector PWM technique which generates the rearranged switching pattern to detect a phase current from ad dc-link current. Experimental results show that eh proposed scheme provides a very good detection method of three phase currents without phase current sensors. This method is very simple and has small detection errors.

  • PDF

22.9kV 배전선로 적용을 위한 DVR의 새로운 외란검출 기법 및 제어시스템 설계 (The New Voltage Event Detection Method and Control System Design for DVR Applied to 22.9kV Distribution System)

  • 김희중;정용호;권기현;박태범;문전일;전영수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권1호
    • /
    • pp.7-12
    • /
    • 2006
  • This paper proposes the new voltage event detection method using the weight factor of neural network and describes control system design for the DVR(Dynamic Voltage Restorer) consisted of a rectifier and series inverter applied to 22.9kV distribution system. As this method can express the fault level of each phase, we expect the proposed method can make up for disadvantage of synchronous detection method. Also, in this paper, the control system was designed using double deadbeat controller, As it has an inner current control loop and an outer voltage control loop, we can easily limit the current level during the transient intervals by using the current control loop. Simulation and experiment are performed to prove the analysis of the voltage event detection method and double deadbeat controller.

A Seamless Transfer Algorithm Based on Frequency Detection with Feedforward Control Method in Distributed Generation System

  • Kim, Kiryong;Shin, Dongsul;Lee, Jaecheol;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1066-1073
    • /
    • 2015
  • This paper proposes a control strategy based on the frequency detection method, comprising a current control and a feed-forward voltage control loop, is proposed for grid-interactive power conditioning systems (PCS). For continuous provision of power to critical loads, PCS should be able to check grid outages instantaneously. Hence, proposed in the present paper are a frequency detection method for detecting abnormal grid conditions and a controller, which consists of a current controller and a feedforward voltage controller, for different operation modes. The frequency detection method can detect abnormal grid conditions accurately and quickly. The controller which has current and voltage control loops rapidly helps in load voltage regulation when grid fault occurs by changing reference and control modes. The proposed seamless transfer control strategy is confirmed by experimental results.

무안경식 3차원 모니터용 실시간 눈 추적 알고리즘 (A Real-time Eye Tracking Algorithm for Autostereoscopic 3-Dimensional Monitor)

  • 임영신;김준식;주효남
    • 제어로봇시스템학회논문지
    • /
    • 제15권8호
    • /
    • pp.839-844
    • /
    • 2009
  • In this paper, a real-time eye tracking method using fast face detection is proposed. Most of the current eye tracking systems have operational limitations due to sensors, complicated backgrounds, and uneven lighting condition. It also suffers from slow response time which is not proper for a real-time application. The tracking performance is low under complicated background and uneven lighting condition. The proposed algorithm detects face region from acquired image using elliptic Hough transform followed by eye detection within the detected face region using Haar-like features. In order to reduce the computation time in tracking eyes, the algorithm predicts next frame search region from the information obtained in the current frame. Experiments through simulation show good performance of the proposed method under various environments.

원칩마이크로콘트롤러를 이용한 전력감시장치 개발 (The Development of Power Detection System Using One-Chip Microcontroller)

  • 신사현;최낙일;이성길;임양수;조금배;백형래
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권4호
    • /
    • pp.180-186
    • /
    • 2002
  • This paper describes on the development of power detection system with one-chip microcontroller. The designed system is composed of power detection circuits and analyzing software. The system detects, 3-phases voltage, 3-phases current, external temperature, leakage current and stores in flash memory. AT89C52 was used as CPU and AM29F040B was used as memory to store the data. The analysis saftware was developed to detect the cause of the electrical fire incidents. With a data-compression technology, the data can be stored for the 43.5 days in a normal state, four hours and fifteen minutes in emergency state.

벡터제어 유도전동기 구동시스템을 위한 센서고장 검출 및 보상 (Sensor Fault Detection and Compensation Schemes for Vector Controlled Induction Motor Drives)

  • 류지수;이기상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.42-45
    • /
    • 2001
  • In the speed-sensorless induction motor control systems, only a few percents of error in current measurement badly deteriorates the control performance. And early detection and accomodation of the faults of current sensor is very important to enhance the reliability of the induction motor control system. In this paper, we propose two sensor fault detection schemes having desired functions; fault detection, isolation of failed sensor and compensation of fault effect. The two schemes operate in real-time and employ EKFs (Extended Kalman Filter) for residual generation. Simulation results show that the proposed schemes are very useful in maintaining the control performance of the induction motor driven servo systems even in the face of sensor faults.

  • PDF