• 제목/요약/키워드: current capacity

검색결과 2,588건 처리시간 0.026초

MCCB내부 금속 그리드 재질이 차단성능에 미치는 영향 (An Influence of Material of Metal Grid for Interrupting Property)

  • 김길수;윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.101-101
    • /
    • 2010
  • Power distribution system requires the transformer with higher capacity than ever, but this ever, but this may be the cause of the increasing of short circuit current in contrast to conventional one when short-circuit accident is occurred. Therefore molded case circuit breaker improved in aspects of interrupting capacity of short circuit current in this system is needed. The arrangement and quality of the material of grids in arc quenching room are also designed optimally by the analysis of arc driving forces.

  • PDF

Quantum modulation of the channel charge and distributed capacitance of double gated nanosize FETs

  • Gasparyan, Ferdinand V.;Aroutiounian, Vladimir M.
    • Advances in nano research
    • /
    • 제3권1호
    • /
    • pp.49-54
    • /
    • 2015
  • The structure represents symmetrical metal electrode (gate 1) - front $SiO_2$ layer - n-Si nanowire FET - buried $SiO_2$ layer - metal electrode (gate 2). At the symmetrical gate voltages high conductive regions near the gate 1 - front $SiO_2$ and gate 2 - buried $SiO_2$ interfaces correspondingly, and low conductive region in the central region of the NW are formed. Possibilities of applications of nanosize FETs at the deep inversion and depletion as a distributed capacitance are demonstrated. Capacity density is an order to ${\sim}{\mu}F/cm^2$. The charge density, it distribution and capacity value in the nanowire can be controlled by a small changes in the gate voltages. at the non-symmetrical gate voltages high conductive regions will move to corresponding interfaces and low conductive region will modulate non-symmetrically. In this case source-drain current of the FET will redistributed and change current way. This gives opportunity to investigate surface and bulk transport processes in the nanosize inversion channel.

교량케이슨기초의 최적신뢰성 설계 규준 (Optimum Reliablity Based Design Criteria for Bridge Cassion Foundation)

  • 손용우;신형우;이증빈;정철원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.79-89
    • /
    • 1992
  • This study is directed to propose a stability analysis and Design Criteria for Bridge Caisson foundations, with Could possibly replace the traditionals W.S.D. provisions of the Current Code, based on the FBOR(Load Factors based on optimum Reliability). The optimum reliability indices(Vertical bearing Capacity : $\beta$opt : 3.19, Lateral bearing Capacity : $\beta$opt= 3.15(ordinary), $\beta$opt : 2.93 (earthquake), Shearing resistance Capacity ; $\beta$opt : 2.87) are Selected as optimal Values Considering our practice base on the Calibration with the current Bridge Caisson foundation design Safety provisions, Load and resistance factors are measure by Using the proposed uncertainties and the Selected optimum reliability indices. furthermore, a set of nominal safety factors are proposed for the U.S.D. design provisions.

  • PDF

납축전지의 성능 향상을 위한 양극판의 숙성과 그리드에 관한 연구 (A Study on the Curing of Positive Plate and Grid to Improve the Capacity of the Lead-Acid Batteries)

  • 구본근;정순욱
    • 한국응용과학기술학회지
    • /
    • 제25권1호
    • /
    • pp.41-47
    • /
    • 2008
  • This study was conducted to made a grid alloy (Pb-Ca-Sn-Al) which has a temporary composition ratio in order to improve the efficiency of lead acid batteries. The positive activity material made a 3BS(tri-basic lead sulfate; $3PbO{\cdot}PbSO_4{\cdot}H_2O$) by a low temperature curing and it evaluates the plate efficiency through the life cycle testing. The initial current capacity of low temperature curing plate was excellent but the life cycle was not good (S1). As for the S2 plate, however, the initial current capacity and the life cycle were superior.

태양광 발전 시스템의 120Hz 리플 전압 영향 감소를 통한 DC-Link 소형화와 출력 전류 왜곡률 감소에 관한 연구 (A Study on the DC-Link Miniaturization and the Reduction of Output Current Distortion Rate by Reducing the Effect of 120 Hz Ripple Voltage on Photovoltaic Systems)

  • 송민근;이우철
    • 전력전자학회논문지
    • /
    • 제26권5호
    • /
    • pp.342-348
    • /
    • 2021
  • The PV module of solar power systems requires maximum power point tracking (MPPT) technique because the power-voltage and current-voltage characteristics vary depending on the surrounding environment. In addition, the 120 Hz ripple voltage on the DC-Link is caused by the imbalance of the system voltage and current. The effect of this 120 Hz ripple voltage reduces the efficiency of the power generation system by increasing the output current distortion rate. Increasing the capacity of DC-Link can reduce the 120 Hz ripple voltage, but this method is inefficient in price and size. We propose a technique that detects 120 Hz ripple voltage and reduces the effect of ripple voltage without increasing the DC-Link capacity through a controller. The proposed technique was verified through simulations and experiments using a 1 kW single-phase solar power system. In addition, the proposed technique's feasibility was demonstrated by reducing the distortion rate of the output current.

The Monthly Water Supply Reliability Indexes in the Parallel Reservoir System

  • Park, Ki-Bum;Kim, Sung-Won;Lee, Yeong-Hwa
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2009년도 학술발표회 초록집
    • /
    • pp.1612-1615
    • /
    • 2009
  • Water supply reliability indexes (WSRI) is estimated for assessment of water supply capacity in the downstream for parallel reservoir system in Nakdong River, South Korea, using allocation rule (AR) according to the water supply capacity of each reservoir and the characteristic of parallel reservoir system. The result of the analyzing parallel reservoir system for Andong and Imha reservoir in Nakdong River does not include evidences available enough to decide whether the results of water supply analysis are excellent in the current reliability evaluation or not. However, AR (C) shows a good result in the water supply capacity for each reservoir based on the connected operation system and the total water supply capacity at the control point of downstream by the average water supply capacity and possible range of water supply capacity suggested by this study. The average water supply capacity is analyzed by the reliability of monthly average water supply capacity. Furthermore, the possible range of water supply capacity is estimated by the standard deviation when water deficit occurs. Therefore, AR (C) is useful to establish and estimate the planning water supply capacity according to the monthly water supply condition and the possible range of water supply capacity when the water supply capacity deficit occurs, South Korea.

  • PDF

확장칼만필터를 활용한 배터리 시스템에서의 State of Charge와 용량 동시 추정 (Simultaneous Estimation of State of Charge and Capacity using Extended Kalman Filter in Battery Systems)

  • 문예진;김남훈;유지훈;이경민;이종혁;조원희;김연수
    • Korean Chemical Engineering Research
    • /
    • 제60권3호
    • /
    • pp.363-370
    • /
    • 2022
  • 본 논문에서는 전기자동차용 배터리 충/방전 상태 추정의 정확도를 개선하기 위해 칼만 필터(Kalman Filter, KF) 알고리즘과 등가회로모델(Equivalent Circuit Model)을 활용한 State Of Charge (SOC) 추정 방법을 적용하였다. 특히 노화된 배터리 용량을 함께 추정 가능한 관측기(observer)를 설계하였다. 우선 노화가 없는 경우, 칼만 필터를 이용하여 SOC를 단일 추정하면, 관측기 없이 모델로 계산된 경우와 비교하여 평균 절대 오차율이 1.43%(관측기 미사용)에서 0.27%(관측기 사용)로 감소하였다. 차량 주행상태에서는 전류가 고정되지 않아 SOC와 배터리 용량을 모두 추정하는 것에 일반적인 KF 혹은 Extended KF 알고리즘을 이용할 수 없다. 배터리 노화에 의한 용량 변화는 단시간에 일어나지는 않다는 점에 착안하여, 충전 시 배터리 용량 추정을 주기적으로 실시하는 전략을 제시하였다. 충전 모드에서는 일정 구간마다 전류가 고정되기에, 해당 상황에서 배터리 노화 용량을 SOC와 함께 추정 전략을 제시하였다. 전류가 고정된 상태에서 SOC 추정의 평균 절대 오차율은 0.54% 였으며, 용량 추정의 평균 절대 오차율은 2.24%로 나타났다. 충전상태에서 전류가 고정됨으로 일반적인 EKF를 활용하여 배터리 용량과 SOC 동시 추정이 가능하도록 하였다. 이를 통하여 배터리 충전 시 주기적인 배터리 용량 보정을 수행할 수 있다. 그리고, 방전 시에는 해당 용량으로 고정한 채 SOC를 추정하는, 배터리 관리 시스템에서 활용 가능한 추정 알고리즘을 제안하였다.

Predicting the axial load capacity of high-strength concrete filled steel tubular columns

  • Aslani, Farhad;Uy, Brian;Tao, Zhong;Mashiri, Fidelis
    • Steel and Composite Structures
    • /
    • 제19권4호
    • /
    • pp.967-993
    • /
    • 2015
  • The aim of this paper is to investigate the appropriateness of current codes of practice for predicting the axial load capacity of high-strength Concrete Filled Steel Tubular Columns (CFSTCs). Australian/New Zealand standards and other international codes of practice for composite bridges and buildings are currently being revised and will allow for the use of high-strength CFSTCs. It is therefore important to assess and modify the suitability of the section and ultimate buckling capacities models. For this purpose, available experimental results on high-strength composite columns have been assessed. The collected experimental results are compared with eight current codes of practice for rectangular CFSTCs and seven current codes of practice for circular CFSTCs. Furthermore, based on the statistical studies carried out, simplified relationships are developed to predict the section and ultimate buckling capacities of normal and high-strength short and slender rectangular and circular CFSTCs subjected to concentric loading.

BSCCO 고온초전도 선재의 접합특성 연구 (A Study of Joint Characteristic of BSCCO Superconductor Tape)

  • 김정호;김중석;김태우;지봉기;주진호;나완수
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.378-382
    • /
    • 1999
  • We evaluated the effect of joining process such as contact method, shape of joined area and pressure on the electrical property of Bi-2223 superconducting tape. It was observed that the current capacity was reduced at the transition area of the joined tape and was significantly dependent on the uniaxial pressure. The lap-joined tape, fabricated with a pressure of 1,000-1,600 MPa, show the highest value of current capacity(80-90%) of the tape itself. It is believed the highest value of current capacity results from improvement in core density, contacting area and grain alignment, etc. In addition, the irreversible strain( ${\varepsilon}$ irrev) for the joined tape· was measured to be 0.1%, smaller than that of enjoined tape( ${\varepsilon}$ irrev = 0.3%). The decrease in the strength and irreversible strain for joined tape is believed to be due to the irregular geometry/morphology of the transition area of the tape.

  • PDF

Key parameters of toroidal HTS coil for a superconducting magnetic energy storage system

  • Miyeon, Yoon;Jinwoo, Han;Ji-Kwang, Lee;Kyeongdal, Choi;Jung Tae, Lee;Seungyong, Hahn;Woo-Seok, Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권4호
    • /
    • pp.50-54
    • /
    • 2022
  • High temperature superconducting (HTS) magnets for large-capacity energy storage system need to be composed of toroid magnets with high energy density, low leakage magnetic fields, and easy installation. To realize such a large capacity of a toroid HTS magnet, an HTS cable with large current capacity would be preferred because of the limited DC link voltage and instantaneous high power required for compensation of the disturbance in the power grid. In this paper, the optimal operating strategies of the SMES for peak load reduction of the microgrid system were calculated according to the load variation characteristics, and the effect of compensation of the frequency change in microgrid with a SMES were also simulated. Based on the result of the simulation, key design parameters of SMES coil were presented for two cases to define the specification of the HTS cable with large current capacities for winding of HTS toroid coils, which will be need for development of the HTS cable as a future work.