• Title/Summary/Keyword: current body image

Search Result 120, Processing Time 0.029 seconds

Characterization of Dynamic Behavior of C. elegans in Different Physical Environments (PIV 및 TFM 측정 기법을 이용한 예쁜꼬마선충의 동적 패턴 가시화 연구)

  • Park, Jin-Sung;Yun, Byoung Hwan;Shin, Jennifer H.
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.2
    • /
    • pp.18-22
    • /
    • 2014
  • Caenorhabditis elegans (C. elegans) is an undulatory nematode which exhibits two distinct locomotion types of swimming and crawling. Although in its natural habitat C. elegans lives in a non-Newtonian fluidic environment, our current understanding has been limited to the behavior of C. elegans in a simple Newtonian fluid. Here, we present some experimental results on the penetrating behavior of C. elegans at the interface from liquid to solid environment. Once C. elegans, which otherwise swims freely in a liquid, makes a contact to the solid gel boundary, it begins to penetrate vertically to the surface by changing its stroke motion characterized by a stiffer body shape and a slow stroke frequency. The particle image velocimetry (PIV) analysis reveals the flow streamlines produced by the stroke of worm. For the worm that crawls on a solid surface, we utilize a technique of traction force microscopy (TFM) to find that the crawling nematode forms localized force islands along the body where makes direct contacts to the gel surface.

A Study on the Effect of the Portrayal of Body Image of Women in Advertisement in Korea and Latin America (한국과 라틴 아메리카에서의 여성의 신체 이미지 묘사가 광고 효과에 미치는 영향에 관한 연구)

  • Gongora Astete, Francisca Paz;Kim, Boyeun
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.369-379
    • /
    • 2018
  • The current study started from the constant internal fight women usually have due to the portrayal of women in advertisement in different socio-cultural backgrounds, a comparison between Latin America and South Korea was held to find the different approaches. And also test the effects of an overwhelming movement that is looking to change history and change the perception of images of constructed beauty and unattainable physical standards called The Body Positivity Movement, using the examples of prominent brands like Dove and Victoria's Secret's advertisements and the AIDA model as the instrument. Male and female in their 30's from South Korea and Latin America have been interviewed to show the differences of opinions.

Extraction of full body size parameters for personalized recommendation module (개인 맞춤형 추천모듈을 위한 전신 신체사이즈 추출)

  • Park, Yong-Hee;Chin, Seong-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.5113-5119
    • /
    • 2010
  • Anthropometry has been broadly explored in various fields including automobile industry, home electronic appliances, medical appliances and sports goods with aiming at reaching satisfaction to consumer's need and efficiency. However, current technologies to measure a human body still have barriers in which the methods mostly seem to be contingent on expensive devices such as scanner and digital measuring instruments and to be directly touchable to the body when obtaining body size.. Therefore, in this paper, we present a general method to automatically extract size of body from a real body image acquired from a camera and to utilize it into recommend systems including clothing and bicycle fitting. At first, Haar-like features and AdaBoost algorithm are employed to detect body position. Then features of body can be recognized using AAM. Finally clothing and bicycle recommending modules have been implemented and experimented to validate the proposed method.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Implementation of a Single Human Detection Algorithm for Video Digital Door Lock (영상디지털도어록용 단일 사람 검출 알고리즘 구현)

  • Shin, Seung-Hwan;Lee, Sang-Rak;Choi, Han-Go
    • The KIPS Transactions:PartB
    • /
    • v.19B no.2
    • /
    • pp.127-134
    • /
    • 2012
  • Video digital door lock(VDDL) system detects people who access to the door and acquires the human image. Design considerations is that current consumption must be minimized by applying fast human detection algorithm because of battery-based operation. Since the digital door lock takes an image through a fixed camera, detection of a person based on background image leads to high degree of reliability. This paper deals with a single human detection algorithm suitable for VDDL with fulfilling these requirements such that it detects a moving object in an image, then identifies whether the object is a person or not using image processing. The proposed image processing algorithm consists of two steps: Firstly, it detects the human image region using both background image and skin color information. Secondly, it identifies the person using polar histogram based on proportional information of human body. Proposed algorithm is implemented in VDDL and is verified the performance through experiments.

THE IMPORTANCE OF PATIENT-SPECIFIC DOSE CALCULATIONS IN NUCLEAR MEDICINE

  • Stabin, Michael G.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.527-532
    • /
    • 2008
  • As therapeutic uses of radionuclides in nuclear medicine increases, the use of patient-specific methods for calculation of radiation dose becomes more important. In this manuscript basic methods and resources for internal dose calculations are outlined, with a focus on how current changes and advances are making more accurate and detailed, patient-individualized dose calculations possible. Most current resources make use of standardized models of the human body representing median individuals, but the use of image-based and more realistic models will soon take their place, and will permit adjustments to represent individual patients and tailor therapy planning uniquely for each subject.

Standardization of Terminology to Boost the Use of 3D Virtual Fitting Program - Analysis of Terminology in Avatar Sizing - (가상착의프로그램의 활성화를 위한 용어 표준화 방안 - 아바타사이징 용어 분석 -)

  • Han, Hyunjung;Jeon, Eunkyung
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.18 no.1
    • /
    • pp.191-203
    • /
    • 2016
  • The 3D virtual fitting system is a new and very efficient system replacing real fitting in apparel industry and on-line shopping. It is a win-win system for both of consumer and manufacturer which not only reduces design and production time but also resolves consumer's complaints by checking the wearing image beforehand. It is a must-have item in the future. The purpose of this study is to analyze sizing menu, terms, and current status and to figure out problems of avatar sizing programs which substitute human bodies in virtual fitting. We chose three existing outstanding programs in domestic and global market, compared and analyzed the program, manual, and terms that are used in avatar sizing, and investigated the strengths, weaknesses, problems of options and terms and finally suggested an alternative terms. The revealed problems are as follows: each program supports various avatars ranging from male to female, from child to adult, and from oriental style to western style. The image of the avatar could be changed through the options for hair style, shoes and accessories. But we found out some problems. The avatar body types are far from actual human body types, avatar sizing menus and item terms are different from program to program, and terms not yet standardized. Cooperative efforts of industry and academy on standardization of sizing menus and terms should be emphasized for the virtual fitting system to be widely used like the other computer graphic programs or word editors.

  • PDF

Eating Attitudes, Weight Concerns, Dietary Intake, and Menstruation Among Korean Female Elite Athletes

  • Lee Dae Taek
    • Nutritional Sciences
    • /
    • v.8 no.2
    • /
    • pp.118-124
    • /
    • 2005
  • To examine the eating attitudes, weight concerns, dietary intake, and menstrual function of Korean female elite athletes, 109 subjects in seven sports disciplines (rhythmic gymnastics, synchronized swimming, badminton, volleyball, Taekwondo, field hockey, and soccer) responded to a questionnaire consisted of three parts; eating attitudes and behavior(Eating Attitude Test-26; EAT26), body weight perception (Body Dissatisfaction Index: BDI) and weight control behavior, and menstrual history and status. They also recorded three-day dietary intake. Body weight (43.6$\pm$4.3 kg) and body mass index (16.7$\pm$1.4 kg/$m^2$) in rhythmic gymnasts were lower than those in other athletes (P<0.05). EAT26 scores were not different among sport events (12.3$\pm$6.5 total), however, eating disturbances (EAT26 score$\geq$20) were highly prevalent in aesthetic athletes ($30\%$) than in others ($5\%$). More than half of the athletes perceived themselves overweight and four fifth of the athletes desired to reduce weight about 4.4 kg. The gymnasts consumed the lowest caloric intake (1028:t371) while the volleyball players did the highest (2995$\pm$342 kcal/d) (P<0.05). The BDI score was not different among sport events. Three fourth of the athletes experienced weight control, and the most frequently used weight reduction method was exercise followed by using robber suits, diet, and sauna. About $40\%$ of the subjects reported irregular menstrual cycles, but menstrual dysfunction ($\leq$6 menses/yr) was only $5\%$. Generally, the Korean female elite athletes desired to reduce weight from their current body weight. No differences in eating attitude and body dissatisfaction were noticed among athletic disciplines. However, eating disturbances were highly prevalent in aesthetic athletes who also reported much less energy intake than the recommend daily energy intake. It appeared that weight reduction methods were not properly practiced in these population. Menstrual dysfunction was minimally reported.

Exposure Expressed in Dress (복식에 표현된 노출)

  • 정연자
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.1 no.1
    • /
    • pp.91-107
    • /
    • 1999
  • The primary purpose of this study is to inquire into the characteristic of exposure presented in fashion, identify the correct concept of exposure from an aesthetic perspective, and grasp the contemporary meaning of exposure presented in fashion. As a result of study, the following findings were obtained: First, the surrealist style of fashion exhibited representations such as the relocation of the partial details, the harmonization of the natural and the artificial, the emphasis or expansion of each part of the body, and the like. It used highlighted the genital region with ornamentations or used the technique of paradoxically exposing the part of the body always covered. And it exbibited the paradoxical relationship of exposure and concealment by exposing the concealed part of the human body. Second, the post-modern style showed the complicated phenomenon that the values of several meanings such as the historic, the folk, and the like appeared in its fashion. It shares in spatiotemporal eclecticism, pluralistic characteristics and the like found in the post-modern culture. Third, the deconstructive style gets rid of the distinction between the external space and the private space by translating underwears into outer garments. It destroys clothing by tearing or perforating clothing whereby it represents the poor image. Coupled with women‘s psychology of exposure and the new generation’s way of thinking indifferent to others‘ eyes, this fashion of deconstruction occupies the great current of fashion. Deconstructive fashion gets away with the rule of ‘having to wear clothing to suit TPO(Time, Place and Occasion), the traditional norm of wearing clothing.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF