• 제목/요약/키워드: cross-over

검색결과 2,595건 처리시간 0.049초

A Eco-friendly Construction Plan of bridge cross over and parallel to rivers (하천 병행 및 횡단교량의 친환경 건설계획)

  • Kim, Young-Sang;Ko, Seung-Young;Kim, Hyoung-Su;Min, Young-Taek
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.131-132
    • /
    • 2009
  • A road construction From Gyegok to Shinduk, korea was ordered for the alternative design by Jeollabuk-do, 2008. The propose of study is to introduce the planning process for a optimal eco-friendly design and construction of bridge cross over and parallel to rivers.

  • PDF

Performance Characteristics of Direct Methanol Fuel Cell with Methanol Concentration (메탄올 농도에 따른 직접 메탄올 연료전지의 성능 해석)

  • Cho, Chang-Hwan;Kim, Yong-Chan;Chang, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제20권3호
    • /
    • pp.197-204
    • /
    • 2008
  • DMFC(Direct Methanol Fuel Cell) is one of promising candidates for power sources of small mobile IT devices like notebook, cell phone, and so on. Efficient operation of fuel cell system is very important for long-sustained power supply because of limited fuel tank size. It is necessary to investigate operation characteristics of fuel cell stack for optimal control of DMFC system. The generated voltage was modeled according to various operating condition; methanol concentration, stack temperature, and load current. It is inevitable for methanol solution at anode to cross over to cathode through MEA(membrane electrode assembly), which reduces the system efficiency and increases fuel consumption. In this study, optimal operation conditions are proposed by analyzing stack performance model, cross-over phenomenon, and system efficiency.

CROSS COMMUTATORS ON BACKWARD SHIFT INVARIANT SUBSPACES OVER THE BIDISK II

  • Izuchi, Kei Ji;Izuchi, Kou Hei
    • Journal of the Korean Mathematical Society
    • /
    • 제49권1호
    • /
    • pp.139-151
    • /
    • 2012
  • In the previous paper, we gave a characterization of backward shift invariant subspaces of the Hardy space over the bidisk on which [${S_z}^n$, $S_w^*$] = 0 for a positive integer n ${\geq}$ 2. In this case, it holds that ${S_z}^n=cI$ for some $c{\in}\mathbb{C}$. In this paper, it is proved that if [$S_{\varphi}$, $S_w^*$] = 0 and ${\varphi}{\in}H^{\infty}({\Gamma}_z)$, then $S_{\varphi}=cI$ for some $c{\in}\mathbb{C}$.

Improved Fast SOM learning algorithm without cross-over (뒤틀림 현상이 없는 FSOM 학습 알고리즘)

  • Jung, Sun-Jung;Jung, Soon-Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 한국정보처리학회 2001년도 춘계학술발표논문집 (하)
    • /
    • pp.1029-1032
    • /
    • 2001
  • 자기구성 특징지도(Self-Organizing feature Map : SOM) 및 $L^*$ 등의 자가 학습 신경망의 알고리즘들은 학습 결과 중에 바람직하지 못한 뒤틀림 현상(cross-over)을 생성하게 되므로 재학습으로 인한 전반적인 학습 시간의 지연을 초래한다. 이 논문에서는 비교적 학습 속도가 빠른 $L^*$의 점증적 학습 구조를 기본으로 하여 뒤틀림 현상 방지를 목적으로 초기 학습 단계에서 학습 가중치들의 노드들을 재조정하는 개선된 알고리즘을 제안한다. 이러한 알고리즘의 실험 결과는 모두 정상적인 학습 결과를 보이고 학습의 시행 착오적인 재실행이 없으므로 전반적인 학습 속도는 기존의 알고리즘보다 빠르게 됨을 보인다.

  • PDF

A new criterion for determining the sampling rate of digital controller (디지털제어기의 제어주기 결정방법에 관한 연구)

  • 이준화;문홍주;정병근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.360-360
    • /
    • 2000
  • In this paper, a new criterion f9r determining the sampling rate of digital conroller is proposed. This paper will introduce a method fur determining the appropriate sampling rate of digital controller which can be substituted with the given analog controller, using phase margin and gain cross over frequency, not rising time or bandwidth of the closed-loop system. This method also guarantees performance of the system. Without exact modeling functions of the plant, abstracting those functions, this paper can achieve stability and aimed performance of the system, and this paper proved it with proper modeling functions.

  • PDF

Bioequivalence Test of Rifampicin Preparations(II) (리팜피신 제제의 생물학적 동등성시험(제2보))

  • Chang, Il-Hyo;Burm, Jin-Pil;Choi, Jun-Shik
    • Journal of Pharmaceutical Investigation
    • /
    • 제24권2호
    • /
    • pp.49-55
    • /
    • 1994
  • Bioequivalence test of commercially available rifampicin capsules was performed. Sixteen volunteers were divided into 2 groups and the reference and test drug were given orally (450 mg) by cross-over design. Statistical evaluation of AUC, $C_{max}\;and\;T_{max}$ involved an analysis of variance (ANOVA). The differences of mean value in AUC, $C_{max}\;and\;T_{max}$ between the reference and test drug were within 20% with reference drug. ANOVA showed no significant differences for ‘between group’, ‘drug’ and ‘period’, but not for ‘between subjects’. The power of test $(1-{\beta})\;of\;AUC\;and\;$C_{max}$ was larger than 0.8 and the confidence of bioavailability was $within\;{\pm}20%$. From these results, it was concluded that the two preparations were bioequivalent for AUC and $C_{max}$, but was not for $T_{max}$.

  • PDF

A Design Guide to Type-3 PLLs for FMCW Radars (FMCW 레이더용 타입-3 PLL의 설계 가이드)

  • Hwang, In-Duk;Kim, Chang-Hwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • 제11권4호
    • /
    • pp.70-79
    • /
    • 2012
  • A design guide to type-3 PLLs for FMCW radars is provided. To do that, the cross-over frequencies of the open-loop transfer functions were normalized to 1 Hz and closed-loop properties were compared through simulations using Pspice. As a result, several guides to design type-3 PLLs were provided: 1) secure 45 degrees of phase margin, 2) locate two zeroes at an identical frequency, and 3) poles may be added to raise order of the PLL at higher frequencies than the cross-over frequency of the open-loop transfer function about ten times.

Evaluation of Capture Efficiencies of Push-Pull Hood Systems by Cross Draft Directions and Velocities Using Smoke Visualization Technique (기류 가시화기법을 이용한 방해기류 방향과 속도에 따른 푸쉬풀 후드 효율 평가)

  • Song, Se-Wook;Kim, Tae-Hyeung;Ha, Hyun-Chul;Kang, Ho-Gyung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제15권1호
    • /
    • pp.36-44
    • /
    • 2005
  • A push pull hood system is frequently applied to control contaminants evaporated from an open surface tank in recent years. Efficiency of push pull hood system is affected by various parameters, such as cross draft, vessel shapes, size of tanks surface, liquid temperature, and so on. Among these, velocity of cross draft might be one of the most influencing factor for determining the ventilation efficiency. To take account of the effect of cross draft velocities over 0.38m/s, a flow adjustment of ${\pm}$20% should be considered into the push and +20% into the pull flow system Although there are many studies about the efficiency evaluation of push pull hood system based on CFDs(Computational Fluid Dynamics) and experiments, there have been no reports regarding the influence of velocities and direction of cross-draft on push-pull hood efficiency. This study was conducted to investigate the influence of cross draft direction and velocities on the capture efficiency of the push-pull ventilation system. Smoke visualization method was used along with mock-up of push-pull hood systems to verify the ventilation efficiency by experiments. When the cross-draft blew from the same origins of the push flows, the efficiency of the system was in it's high value, but it was decreased significantly when the cross-draft came from the opposite side of push flows Moreover, the efficiency of the system dramatically decreased when the cross-draft of open surface tank was faster than 0.4m/s.

Linearization of DFB LD by using Cross Gain Modulation of Reflective SOA in Radio-over-Fiber Link

  • Hong, Moon-Ki;Han, Sang-Kook;Lee, Sang-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제11권4호
    • /
    • pp.158-161
    • /
    • 2007
  • We proposed a novel linearization technique for a DFB LD in the RoF link. The proposed scheme is based on the cross gain modulation(XGM) effect of a reflective semiconductor optical amplifier(RSOA) with light injection. We experimentally demonstrated and evaluated the enhanced CIR performance using the proposed linearization scheme.